| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.0 L+₹13.1 L (38.8%)Rejected-Finance 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹49.1 L+₹15.3 L (45.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹49.3 L
EMD Value
₹98,600
Closing Date
30 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-T-46/2022-23 IMPROVEMENT TO BASE OPS COMPLEX AND CERTAIN E/M SERVICES AT RT CABIN/CADF WITH CERTAIN MINOR WORKS AT AF STN AMBALA UNDER GE AF AMBALA
2022_MES_572367_1
GE AF/AMB-T-46/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹98,600
Yes
7 Mar 2023
31 Dec 2022
1 Feb 2023
31 Dec 2022
30 Jan 2023
17 Jan 2023
2 Jan 2023 - 7 Jan 2023
Amount
B/R Works
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying pipes, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
All as per item No. 2.00 above, but depth exceeding 1.5m and n.exc 3.0 m depth.
Excavation over areas n.exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials (any type of soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading in low lying area and leveling complete all as specified and directed .
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) directed complete all as specified and directed .
M & L for 100mm thick plain cement concrete,1:2:4, type B-2 (using 40mm graded crushed stone aggregates) as in sub base, finished even and fair complete all as specified and directed .
M & L for 25mm thick plain cement concrete,1:2:4, type B-1(using 20mm graded crushed stone aggregates) in sub base finished even and fair complete all as specified and directed .
M & L for cement concrete plain cement concrete,1:2:4, type B-2 (using 40 mm graded crushed stone aggregates) as in surface channels and drains complete all as specified and directed.
M&L for PCC 1:2:4 type B-1(using 20mm graded mechanically crushed stone aggregates) as in coping / bonding of interlocking tiles/ edging complete all as spd and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc.complete all as spd and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm for forming fair finished drain or channel complete all as specified and directed.
M&L 100 mm thick plain Cement concrete (1:4:8), type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed.
M & L for Precast cement concrete in 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in Kerb Stone window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and directed by Engineer-in-charge.
M & L for Cement concrete of type B1, 1:2:4 of (using 20 mm graded crushed stone aggregates) in drain Channel concrete, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-charge.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and removing serviceable tiles to store yard and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
M&L for coloured glazed designer ceramic tiles 300 x 450 x 7 to 8mm thick on vertical surface as in dado/skirting and jointed in neat cement slurry and pointed with white/colour cement to match with the surface overand including 10mm thick backing in CM 1:3 complete all as specified and directed.
M & L for Non skid/ joint free ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exc 0.38 Sqm, in floors etc.set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over and including Screed bed or bedding layer of mortar 15mm of thick CM 1:4 for laying floor finishes complete all as specified and directed.
M&L for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface. complete all as specified and directed by Engineer-in-charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 80mm thickness, M-40 Grade complete all as specified and directed.
Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-charge.
Demolition and breaking up drain pipe (SGSW /reinforced/CI /PVC etc)) of 150/100/75 mm nominal bore laid in trenches, set & jointed in cement mortar complete all as specified and directed by the Engr-in-Charge.
Cutting into existing man holes for connecting new drains of 150mm dia, making good to pipe and rendering cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1(using 20 mm graded crushed stone aggregates) smooth finished and reforming benching complete all as specified and directed by the Engr-in-Charge.
M&L for Reinforced Concrete Pipes , Class NP -2 , laid in trenches and jointed as specified of 150 mm internal dia of pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in packing under and haunching against the sides of pipe or as required at site after the pipes are laid over the existing bed and tested for 150 mm bore of pipe all as specified and as directed by the Engr-in-Charge.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'B' complete all as specified and directed.
Taking down Cement plaster brick work ,concret surface of wall etc complete all as specified and as directed
Material and labour for rendering 15mm thick on any faces of brick wall or concrete surface in CM 1:4 mixed with WPC @ 2% by weight of cement finished fair and even without using extra cement complete all as directed. Note : WPC shall be measured and paid separetely.
Supply only integral water proofing compound.
M & L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surface even and smooth without extra cement complete all as specified and as directed
M&L for preparaion of old/new plastered surface of RCC/stone/concrete/bricks walls etc and applying two coats of exterior acrylic paint over a coat of primer in camoflaging pattern of any shade and pattern complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion over one coat of primer including chalk whiting complete all as specified and as directed
Dismantling of boarding including fillets of any description fixed in any position with nails/screws etc complete all as specified and directed.
S&F solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixed at site on PVC frame as per specification and dwg complete all as specified and directed.
S&F 5mm thick PVC sheet fillets of width 35mm for wall penelling inclusive of fixing on to wall to make PVC frame etc complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar complete all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
All as per item No 38.00 here in before above but except bricks.
Supply & fixing single leaf door with hydraulic mechenism with 80-100mm jam of 0.80mm thickness shutter sheet and frame thickness shall be 1.20mm lead line door to fit flush into the brickwall on both sides. Shutter with GI sheet on both sides with powder coating in approved colour with honeycomb papercore as infill fixed with polyurethane glue including all hardware i.e Hinges, Dead locks handle with push plate, door closer and door seal etc as specified and directed.
E/M Works
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4 sqmm drawn through and including non - metallic rigid PVC conduits/PVC casing caping (as per site requirement) of suitable size with all necessary fittings and provision of one run of 4 sqmm PVC insulated unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed. Note: Two runs of 4sqmm cable, one run of 4 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
M & L for modular switch 1 Way 16A, 230 volts, 2 module complete all as specified and directed.
M & L for modular socket 6/16 amps, 230 volts, 2/3 pin combined. 2 module complete all as specified and directed.
S&F modular white cover plate with frame 4 module complete all as specified and directed.
S & F surface mounting plastic boxes for modular switches for 4 modules complete all as specified and directed.
S&F 15/ 16 A, 3 Pin type Top plug complete all as specified and directed.
S&F 5/6 A, 3 Pin type Top plug complete all as specified and directed.
M&L for cable route Indicator made out of cast iron and embedded LT cable on the plate of size 80mm dia and 5mm thick including grouting the legs of suitable size in PCC 1:3:6, type C-1 (using 20mm graded mechanically crushed stone aggregates) block of size 150x150x150mm in foundation including necessary form work complete all as specified and directed.
Supply, installation, testing & commissioning of powder coated compartmentalized LT panel, of suitable size, front and back openable, outdoor type, with louvers and air vents, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 4 Nos rated aluminium bus bar 400A 3 phase and neutral, internally connected with aluminium strip of appropriate size, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), panel of IP-54 protection class, conforming to IS-13947, fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 415V, 50Hz supply with cable ally on both sides, gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in ground with PCC foundation 1:2:4, type B-1 using 20mm graded stone aggregates (as per manufacturer's instructions) painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the following switchgears complete all as specified and as directed:- Incoming:- (i) MCCB three phase adjustable type with thermal magnetic release 250A 35kA four pole - 1No. Outgoing:- (i) MCCB three phase adjustable type with thermal magnetic release 100A 25kA four pole - 2Nos. (ii) MCCB three phase 63 amps 16 KA FP.-01 no (iii) Digital ampere meter and voltmeter (iv) Indcating lamps (RYB) - 1 set
Supply, installation, testing & commissioning of powder coated compartmentalized LT panel, of suitable size, front and back openable, outdoor type, with louvers and air vents, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 4 Nos rated aluminium bus bar 600A 3 phase and neutral, internally connected with aluminium strip of appropriate size, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), panel of IP-54 protection class, conforming to IS-13947, fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 415V, 50Hz supply with cable ally on both sides, gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in ground PCC foundation 1:2:4, type B-1 using 20mm graded stone aggregates (as per manufacturer's instructions) painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with accommodating and including the following switchgears complete all as specified and as directed:- Incoming:- (i) MCCB three phase adjustable type with thermal magnetic release 400A 35kA four pole - 1No. Outgoing:-(i) MCCB three phase adjustable type with thermal magnetic release 250A 25kA four pole - 1Nos. (ii) MCCB three phase adjustable type with thermal magnetic release 160A 25kA four pole - 3Nos. (iii) MCCB three phase 63 amps 16 KA FP.-01 no (iv) Digital ampere meter and voltmeter (v) Indcating lamps (RYB) - 1 set
S&F Bus bar Chamber of size 60x60x45cm suitable of 3 phase 433 Volts outdoor type made out of 3.15 mm thick M S Sheet with 400 Amps rated aluminium busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black) with locking arrangments and angle iron stand of size 40 x 40 x 6mm frame grouted in ground with PCC foundatiuon 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connections,lugs and cable gland including 2 coat of paint over a coat of red oxide primer all as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly vertically in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead strip 32x6 mm size upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,40mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified.
M&L for surface point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including in non metallic rigid PVC conduit not less than 19mm dia medium grade ISI marked and conduit accessories fixed on surface of iron truss / I section/ wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following:-
(a) One exhaust fan point controlled by one switch 6 amp one way.
S&F switch piano flush type single pole, one way 6 amp complete all as specified and directed
S&F ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed
S&F Exhaust fan metal body of size 450mm sweep single phase with louvers including necessary B/R works for making the hole in wall or increasing the size of existing hole as per the size of exhaust fan complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sq mm 3 core complete.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked IS 7098 with stranded aluminium conductor of size 95sqmm 3.5 core complete all as specified and directed.
S&F end jointing kit for 11 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 3 core XLPE armoured aluminium conductor cable of size 50 to 95Sqmm complete all as specified and directed.
S&F end jointing kit for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 95Sqmm complete all as specified and directed.
Supply and spread sand in cable trenches (08cm below cable as cable bed & 15cm above cable) for providing cushioning for the cable complete all as specified & directed. Note:- Only punned thickness of 18cm will be measured for the purpose of payment.
Supply and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified & directed.
Supply and lay burnt brick of size 230x115x75mm for protection of cable, laying perpendicular to the axis of cable in trenches complete all as specified and directed.
M&L for making bore below the road for crossing the GI Pipe light grade 80mm dia for cable protection and fill the putty on both side of GI pipe after crosing the armoured cable to avoid the water inside complete all as specified & directed.
S&F GI pipe 80 mm bore light grade ISI marked with fittings for cable protection laid in trenches, floors or fixed to poles with suitable size of MS clamps made from F I 40 x 3 mm size and including Nuts, Bolts and washers complete all as specified and directed.
M&L for galvanized steel water tubing medium grade with all required fittings such as elbow, unions, nipples, tees, bends, short pieces, connectors, back-nuts, caps, plugs, diminishing pieces and sockets, etc. as per site requirement complete all as specified and as directed of the following bores:
S&F Gate valve Heavy duty gun metal full way with iron wheel head screwed both ends ISI marked of size 50 mm Dia complete all as specified & directed.
S&F Gate valve Heavy duty gun metal full way with iron wheel head screwed both ends ISI marked of size 40 mm Dia complete all as specified & directed.
S&F Gate valve Heavy duty gun metal full way with iron wheel head screwed both ends ISI marked of size 25 mm Dia complete all as specified & directed.
S&F Gate valve Heavy duty gun metal full way with iron wheel head screwed both ends ISI marked of size 20 mm Dia complete all as specified & directed.
S&F Gate valve Heavy duty gun metal full way with iron wheel head screwed both ends ISI marked of size 15 mm Dia complete all as specified & directed.
M&L for rotational moulded polyethylene water storage tank of capacity 1000 ltrs (cylindrical, vertical with closed top) hoisted and fixed in position all as specified.
S&F ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipes & fixed of size 25 mm complete all as specified & directed.
M&L for installing, testing and commissioning non clog (sludge) pump, stainless steel & cast iron body, electric driven, 220 volts, 1 phase suitable for dischrage of 400-100 lpm at 1.8 - 10.8 mtr head, including necessary accessories required for fixing and commissioning like fixing clamps, carbon steel chain/saungal 10mm thick suitable for holding to Non clog submersible pump for carrying the pump in sludge well, complete all as specified and as directed. Make: Crompton model STMP12(1PH)-10, or equivalent in Kirloskar/ Havells.
supply and Install Pumping sets, monoblock type, electric driven, 220 volts, 1 phase suitable dischrage of 2700-420 lph at 6-36 mtr head complete and inclusive all connected accessories like inlet, outlet nipples etc, all as specified and directed.
Supply and fix PVC cable submersible flat copper 3 core 4 Sqmm 1100 volt grade ISI marked and including taking out old unsv PVC cable any size and type complete all as specified and directed.
Bairagi Builders
R. P. Suppliers and Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .