Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC BANARHAT PO BANARHAT DIST JALPAIGURI PIN 735202 W B | JALPAIGURI | WEST BENGAL | 735202 | ₹23.5 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹26.5 L+₹3.0 L (12.7%)Rejected-Finance | ₹26.5 L+₹3.0 L (12.7%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹28.9 L+₹5.4 L (23.0%)Rejected-Finance | ₹28.9 L+₹5.4 L (23.0%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
9 Dec 2020, 6:00 pmClosed
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
MAINT OF SERVICE OVERHEAD WATER TANK FOR REPLACEMENT OF GI PIPES INCLUDING ALL FITTINGS AND WATER PROOFING IN OTM AND MD ACCN AT EAST AND WEST SIDE OF LEHL MARG UNDER GE (SOUTH) BINNAGURI
2020_MES_394689_1
8402/E8
Open Tender
Civil Works
Item Rate
150 days
GE (SOUTH) BINNAGURI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹52,000
Yes
27 Jan 2021
11 Nov 2020
10 Dec 2020
11 Nov 2020
9 Dec 2020
26 Nov 2020
Amount
S&F in reparis 15mm bore Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed with and including wall flange (Minimum weight 15mm-90gms) complete all as specified and directed.
Taking up or down steel tubing and connections 15mm bore complete all as specified and directed.
S& F 15 mm bore steel water tubes, medium grade, galvanised with all fitings and fixed to wall, complete all as specified and directed.
Refixing of 15 mm bore old steel water tubes, after cleaning and repairing in old or new position, complete all as specified and directed.
Taking up or down steel tubing and connections 20mm bore complete all as specified and directed.
S& F 20 mm bore steel water tubes, medium grade, galvanised with all fitings and fixed to wall, complete all as specified and directed.
Refixing of 20 mm bore old steel water tubes, after cleaning and repairing in old or new position, complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to trenches, floor complete all as specified and directed.
S&F of PVC (SWR) bend/branches any radius suitable for 75mm bore PVC pipe jointed with solvent complete all as specified and directed.
S&F 75 mm PVC (SWR), Junction single, (Single/Double T) equal or unequal), with oval access door, complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to trenches, floor complete all as specified and directed.
S&F of PVC (SWR) bend any radius suitable for 110mm bore PVC pipe jointed with solvent complete all as specified and directed.
S&F 110 mm PVC (SWR), Junction single, (Single Y/T) equal or unequal), with oval access door, complete all as specified and directed.
Disconnecting existing PVC water tank of capacity exc. 250 ltr but n.exc. 500 ltr setting aside or lowering if required for repair and cleaning etc. and hosting if required reconnecte and refix in position after cleaning and writting date of clean with black/white paint etc. complete all as specified and as directed.
Disconnecting existing PVC water tank of capacity exc. 500 ltr but n.exc. 1000 ltr setting aside or lowering if required for repair and cleaning etc. and hosting if required reconnecte and refix in position after cleaning and writting date of clean with black/white paint etc. complete all as specified and as directed.
S&F in repair rotational moulded,Threelayer HDPE water storage tank of 500 ltrs capacity(Cylindrical vertical with closed top) ISI (IS 12701-1996) marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms ) including fixing of inlet, outlet & overflow pipe etc, and lowering & taking out dismantled tank out of site complete all as specified and as directed.
S&F in repair rotational moulded,Threelayer HDPE water storage tank of 1000 ltrs capacity(Cylindrical vertical with closed top) ISI (IS 12701-1996) marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms ) including fixing of inlet, outlet & overflow pipe etc, and lowering & taking out dismantled tank out of site complete all as specified and as directed.
S&F in repair 20 mm dia. gun metal, globe or gate valve with iron wheel head, screwed both ends complete all as specified and directed.
S&F in repair PVC tank lid/cover for 500/1000ltr capacity complete all as specified and directed.
S&F in repair ball valve 20 mm dia. High pressure of PTMT with epoxy coated aluminium rod and high density plastic ball valve screwed with iron pipe complete all as specified and as directed.
S&F in repair stop valves fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed both ends including necessary fittings all complete as specified and as directed.
S&F in repair angle stop valves fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed both ends including necessary fittings all complete as specified and as directed.
Taking up or down steel tubing and connections 25mm bore complete all as specified and directed.
S& F 25 mm bore steel water tubes, medium grade, galvanised with all fitings and fixed to wall, complete all as specified and directed.
Refixing of 25 mm bore old steel water tubes, after cleaning and repairing in old or new position, complete all as specified and directed.
Taking down cement or cement lime plaster any description from walls/ceiling etc including racking out joints, hacking for key & scrubbing down with water complete all as specified and directed.
Demolition of brick masonary work, built in cement mortar including all quions, arches, pillars, etc. but excluding precast concrete articles etc. and deposited where directed complete all as specified and directed.
M&L for brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L rendering 15 mm thick in cm 1:4 on other than fair faces of brick work or concrete surfaces finishing surfaces even and smooth without using extra cement , complete all as specified and as directed.
M&L rendering 15 mm thick in cm 1:6 on fair faces of brick work or concrete surfaces finishing surfaces even and smooth without using extra cement , complete all as specified and as directed.
Material and labour fo preparation of new plastered or unplastered surafces of wall and applying three coats of white wash complete all as specified and directed.
Material and labour fo preparation of old plastered or painted surafces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying one coat of cement base paint complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for including cutting reinforced as required complete all as specified and directed.
M&L for TMT bars 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for fair finished flat surface of concrete complete all as specified and directed.
M&L for RCC 1:2:4 using 20 mm graded stone aggregate as in slab supported on wall,beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
S&F in repair 40 mm dia. high density polyethylene pipes (HDPE) with all pipe fittings such as ends, elbow, unions, tees, reducing tees,adoptor, sockets, plug, hose, clip etc.and fixing to wall or laying in trenches complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement base primer including cleaning glass, joinery,electrical fittings, wiring etc., of drops and splashes complete all as specified and directed.
M&L for preparation of old steel and iron surface of any description, not otherwise described width or girth exc 10 cm and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of newly steel and iron surface of any description width or girth exc 10 cm and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old wood or wooden base materials of any description, not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantaling of old unserviceable steel or iron work of any description complete all as specified and as directed.
M&L mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for stairs(framed) including stringers, treades, landing, balausters, hand rail etc. Including cleat brackets conforming to Fe-410W Gde E-250 quality 'A' complete all as specified and directed.
M&L for high tensile 550 MPA yield strength Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering The sheet shall have a hot dip metallic zinc aluminium alloy coating of zinc 43.5%, aluminium (55%)and silicon (1.5%) with total mass coating of 150 gms/sqm on both sides. Covered width will be 1020mm and sheet length as per site requirement. The profile is having return leg for proper side lap. The sheet shall be fixed using self drilling/self capping screws with EDPM seal complete all as specified and directed. ( Make: TATA blue scope or equivalent of CRIL/METCO.)
All as per item No- 46 here- in- above but Plain sheets as in ridges/ hips / valley/Eaves and Eaves board - ditto --
Taking down existing tarfelt including plaster of any type and course from roof surface including adjoining parapets and removing the materials to a distance exc 50 mtr but n.exc 100 mtr away and deposited where directed including roughening old concrete surface by tucking and rubbing with wire brushes and cleaning the surfaces with water to remove all loose dirts etc complete all as specified and directed.
M&L for 15mm thick plastering in CM(1:4) using WPC @ 3% by wt. of cement,in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane roof treatment complete all as specified and directed. Note:- WPC shall be measured and paid separately.
Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed.
M&L for roof treatment with polymeric water proofing membrane to non accesible roof with the following courses as under complete all as specified :- (a) Cleaning surface by wire brushing,brooming, removing dust complete and make the surface even and smooth. (b) Applying a coat of bitumen primer conforming to IS-3384 - 1965 @ 0.40 lit/Sqm and allow to dry. (c) Applying one coat of hot blown bitumen grade 85/25 as per IS-702-1988 @ 1.20 Kg/Sqm of each coat applied over primer incl cleaning of surfaces . (d) Supply and laying 3mm thick polymeric water proofing membrane weight not less than 3.6 Kg/Sqm with nonwoven polyester fabric weight not less than 160 gms/sqm over area including overlapping of 100mm(min) as per manufacturers instruction.Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP bassed polymenic membrane shall be done torch on methed or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (e) Applying evenly one coat of bituminous aluminium paint @ 150 gm/Sqm complete all as specified and directed. NOTE: The complete work shall be done under strict supervision of manufacturers technical representative and as directed.
S&F in repair rotational moulded,Threelayer HDPE water storage tank of 250 ltrs capacity(Cylindrical vertical with closed top) ISI (IS 12701-1996) marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms ) including fixing of inlet, outlet & overflow pipe etc, and lowering & taking out dismantled tank out of site complete all as specified and as directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for plain cement concrete 1:3:6 Type C1 (using 40mm graded stone aggregate ) as in drains, surface channels, etc including necessary form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete,using extra cement, including form, moulds,mitred/stopped ends etc complete all as specified and directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm ---------------- Ditto -----------. (Only rate to be quoted)
M&L for 75mm thick plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection and footpath finished even and smooth without using extra cement, including making joints to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:2 by weight complete all as specified and as directed.
M&L for 50 mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in flooring finished even and smooth without using extra cement, complete all as specified and as directed.
S&F in repair plain mild steel black sheet 1.00 mm thick as coverings for gate and similar works, cut to size, holes punched, including rounded headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc. as required complete all as specified and as directed.
S & F in repair 15 mm dia bib tap cast copper alloy (fency type), chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and as directed.
SCHEDULE OF CREDIT Rate quoted by the Tenderer for this schedule should not be less than rate assessed by the department shown on estimated rate column for the respective items and total amount under col No 53 will be adjusted accordingly.
Old brick bats of any description
Old unserviceable GI pipe 15 mm dia.
Old unserviceable GI pipe 20 mm dia.
Old unserviceable GI pipe 25 mm dia.
Old unserviceable PVC water tank
Old unserviceable gun metal or gate valve
Old unserviceable PVC SWR pipe
Old unserviceable pvc lid cover
Old unserviceable ball valve
Old unserviceable stop cock, bib taps, pillar taps, shower rose, angle valve any type
Old unserviceable iron scrap
Old unserviceable steel sheet
flexpro construction company
M/s. RAMPHAL GARG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .