Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC KRISHNAKRIPA KOTTARAKARA | ₹1.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹32.5 L (26.3%)Rejected-AOC | ₹1.6 Cr+₹32.5 L (26.3%) | L2 | Rejected-AOC L2 |
Tender Value
₹1.3 Cr
EMD Value
₹50,000
Closing Date
26 Oct 2023, 6:55 pmClosed
Chief Electrical Engineer
O/o The Chief Electrical Engineer, PWD Electrical Wing, Public Office, Thiruvananthapuram
NABARD MCK 2022 2023 Establishing Institute of Infectious Diseases NABARD RIDF XXVII Establishing Institute of Infectious Diseases Phase I at Govt Medical Collage Kottayam -providing DG and USS
2023_PWD_612594_1
PWD/BLDG/TR/8362/2023_26_1_1/1
Open Tender
Electrical Works
Item Rate
180 days
MC kottayam
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,515
₹50,000
Yes
9 Jan 2024
12 Oct 2023
30 Oct 2023
12 Oct 2023
26 Oct 2023
12 Oct 2023
12 Oct 2023 - 26 Oct 2023
Amount
SITC of 750KVA Transformer
OD141337/2023-2024:Supply, conveyance, installation, testing and commissioning of 750 K.V.A Indoor type unitized sub station of IP class 54, with cast resin Transformer (with Out load break switch on H.T.side, and Metering CT and PT) ,with Top/bottom entry cable box, The LT Portion Shall include Neutral CT with MC12 Relay on L.T. side. Transformer Portion consists of 750 K.V.A , 11 K.V, 50 Hz, Delta/Star connected cast resin insulated copper wound transformer. The core shall be made of high grade grain oriented silicon M4 steel lamination insulated and oxide layer and outside of the core shall be protected against corrosion by epoxy resin finish. Class 'F' insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achieve tap positions of +5% to -10% in step of 2.5%. four channel Temperature Scanner with 4 nos Sensors, annunciator and trip mechanism shall be provided. The Transformer shall conform to IEC 726 & IS 11171/1985 re-affirmed in 1991. The maximum allowable loss limited to values designated by ECBC Norms 2007 . All inter connection from HT Side to transformer and to LT Side shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the point of contacts. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The enclosure shall be fabricated from 2.00mm CRCA sheet, complying with of IP 54 standards and shall be powder coated over a coat of Zinc chromate primer after seven tank processing and phosphatizing. The USS shall be installed as per the directions at site.
OD34616/2023-2024:Supply, Conveyance, Installation, Testing and Commissioning of 1 no 11KV Multi panel system , Indoor type for 2 Nos. transformer Comprising the following accessories (Excluding Metering CT , PT and TOD Meter):- 1) 11 KV, 630A,25KA for 3 Sec, horizondal Draw Out VCB fitted with Manual/Motor operated Spring Charging Mechanism with 230V AC Motor and control switch, Shunt Trip Coilof 24V DC, Closing coil of 24V DC, Auxiliary contacts with 2 NO + 2NC, Mechanical ON/OFF Indicator, Automatic safety Shutters and Push Buttons 1 no for incoming and 2 Nos for out goings. 2). 11KV Resin Cast CT (-/5 A,5P10,15VA) Dual core - I/C VCB-3 nos and 6 nos for 2 O/g VCB 4). 11KV Resin Cast PT (11KV/110V,100VA,Class 0.5) I/C VCB - 1 no 5). Protection Devices. a. Instantaneous IDMT relay with Microprocessor based 3O/C+IEFRrelay I/C VCB 1 no. 2 nos for O/g VCB b. Master Trip Relay I/C VCB 1 no. 2 nos for O/g VCB c. Auxiliary relay 1 no I/C VCB 1 no. 2 nos for O/g VCB 6). Metering & Indication Devices. a. Multi Function Meter . 2 nos for O/g VCB. b. Digital Volt Meter 1 no I/C VCB. c. Indicating Lamps for VCB ON.OFF,Spring Control, Trip, Circuit healthy, DC ON. I/C VCB 1 no + O/g 1 & 2 VCB (ON /OFF). 7. Bus bar Connections Aluminium Bus bar 1set 1 no I/CVCB + 1 set O/g 1 & 2(LBS). 9). Panel Accessories. a. 8 window annunciation Panel with Alarm 1 no I/C VCB & 2 nos for O/g VCBs. b. power pack 230V AC-24 V DC 1 no I/C VCB. & 2 nos for O/g VCBs. c. Breaker Control Switch 1 no I/C VCB + 2 nos for O/g VCBs. d. Switch with Plug point. 1 no I/C VCB + 2 nos for O/g VCBs. e. Space Heater. 1 no I/C VCB + 2 nos for O/g VCBs. f. Thermostat 1 no I/C VCB + 2 nos for O/g VCBs. g. Cubicle lamp with switch 1 no I/C VCB + . 2 nos for O/g VCBs. h. control wiring 1 lot 1 no I/C VCBM 2 Lot for O/g VCBs.
3.5.3:Supplying, installation, including suspension, testing and commissioning of following capacity bus trunking with aluminium bus bars in 1.6mm thick sheet steel enclosure in convenient sections for use on, 3 phase, 4 wire, 415 volts, 50 Hz, A.C. supply including jointing of sections, flexible joints, expansion joints, bends and earthing with 2 runs of galvanised iron strips, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.1250 amps
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
OD35462/2023-2024:Supply and providing Aluminium bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providing heat shrink sleeves etc. as required.
OD23484/2023-2024:Supply and providing Panel mounting fresh air fan150 mm as required.
90.14.8.18:1250 A, 4 pole, electrical draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA
OD23594/2023-2024:Supply, conveyance and fixing the following types & current rated control gears & switch gears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 400 A, 36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.
OD23611/2023-2024:Supply, conveyance and fixing the following types & current rated control gears & switch gears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 630 A, 36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.
OD23593/2023-2024:Supply, installation, testing and commissioning of 400A 4 pole spreader terminal(set of 8) and giving connections required.
OD23623/2023-2024:Supply, installation, testing and commissioning of 630A 4 pole spreader terminal(set of 8) and giving connections required.
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
90.14.24.31:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.34:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.36:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.37:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.38:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.25 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
OD23488/2023-2024:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 5 KVAR & with 1 NO auxiliary contact in the existing panel assembly as required.
OD23489/2023-2024:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 10 KVAR & with 1 NO auxiliary contact in the existing panel assembly as required.
OD23490/2023-2024:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 15 KVAR & with 1 NO auxiliary contact in the existing panel assembly as required.
OD23491/2023-2024:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 20 KVAR & with 1 NO auxiliary contact in the existing panel assembly as required.
OD28805/2023-2024:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 25 KVAR & with 1 NO auxiliary contact in the existing panel assembly as required.
OD23492/2023-2024:Supply & fixing 12 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.accessories in position and giving connection.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
OD23487/2023-2024:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
OD23493/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 16.0 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment's including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
OD23494/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 10.0 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required
OD23495/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 6.0 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment's including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.-
OD23496/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 4.0 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
OD23497/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.5 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
OD23498/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 1.5 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
OD23499/2023-2024:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 2 core 2.5 sq mm with factory made clamp
OD27796/2023-2024:Supply and fixing 400/5 A, 15 VA, accuracy class 1, Resin Cast Metering CT
OD27700/2023-2024:Supply and providing 1000/5A , 15VA resin cast metering CT with accuracy class 1 in the existing panel board and giving necessary connection as required-
OD23502/2023-2024:Supply and installation of Three phase multi function meters to read V, A and F, accuracy class 1
OD57266/2023-2024:Supply and providing Blue colour LED indicator lamp, AC/DC, 22.5 cm cut out dia-
OD57267/2023-2024:Supply and providing Red, Green, Black, Yellow, Orange colours LED indicators, AC/DC 22.5mm cut out dia-
OD23506/2023-2024:Supply, installation, testing and commissioning of Flush head Push Button with 1 NO Block.
OD23507/2023-2024:Supply, installation, testing and commissioning of Flush head Push Button with 1 NC Block.
OD23508/2023-2024:Supply and fixing water proof emergency stop Rotary Self-locking Push-button Switch with IP65 protection and giving connections required.
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
OD23510/2023-2024:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. --
OD23511/2023-2024:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminum power cable, 11 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 3 core 300 sqm stranded compact circular aluminum conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. --
OD27867/2023-2024:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in ground including excavation of trench of size 35 x 100 cm, refilling the trench etc. as required 3 core 300 sqm stranded compact circular aluminum conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. --
90.12.9.6:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench110/94 mm or nearest size
10.3.4:Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
OD27792/2023-2024:Supply and providing cable trays or frame work of all sizes with angle iron/flat iron suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gears/Cable/machines for support , fixed to wall/floor using suitable size anchor bolts etc grouted to wall, making good the damages, colour washing etc as required
OD147284/2023-2024:Supply and providing plate earthing with 1200x1200x12mm GI earth plate,50 mm GI(medium class) watering pipe,GI funnel with weld mesh,25x5 mm GI clamps,CI/MS cover plate with locking arrangements,charcoal/coke and salt etc including providing brick work masonry enclosure at the top (450x450x450mm inside)etc as required.
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
4.1.5:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD54277/2023-2024:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel as required.
OD23514/2023-2024:Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the outdoor cat walk plat form.
OD23515/2023-2024:Supply and providing Danger 415 V, 125 x 75 mm aluminium anodised legend plates in the existing panel board as required-
OD23516/2023-2024:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required. 2.5 cm, 4 cm, 5 cm height
OD23517/2023-2024:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
OD23518/2023-2024:Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.
OD23519/2023-2024:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
OD23521/2023-2024:Supply and installation of ABC type fire extinguisher of 5 kg. Capacity complete with initial charges and installation brackets conforming to IS15683 with ISI mark -
OD23526/2023-2024:Charges for dismantling the existing cables of following sizes and reclamping in new position and give connection to new panels. 185 sqmm to 400 sqmm
OD23527/2023-2024:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy
OD23528/2023-2024:Copying charges of Electrical/fire Drawing per A3 sheet additional copies
SITC of 750KVA DG
OD37235/2023-2024:Supply, Conveyance, Installation, testing and Commissioning of 750KVA DG set as per technical details given below on :- i. Engine a. Make of Engine : As specified in the material list b. Type of Engine : Diesel Engine c. No. of Cylinders : Suitable to develop the required BHP as per manufacturers’ standard d.Method of Cooling: Water Cooling (with radiator) e. Aspiration : Tubro charged after cooled f. Design : Suitable for generator set application g. Output : BHP ratings specified by the respective manufacturers’ capable of delivering the required power for alternator. ii. Standard accessories with Diesel Engine a. Flywheel housing and flywheel to suit single bearing alternator (Close coupled arrangement) b. Air Cleaner c. Coolant Kit d. Fuel Pump e. Electronic governor with solid state potentiometer accepting digital pulse input from PLC(backed with mechanical governor –if supplied as standard with the set by the manufacturer) f. Fuel filter g. Lubricating Oil filter h. exhaust silencer iii. Engine Instrument Panel a. Starting switch with key or button b. Lubricating oil temperature gauge c. Lubricating oil pressure gauge d. Water temperature gauge e. RPM Indicator with hour meter . iv. Safety Controls for Engine a. Trip for low lubricating oil pressure b. Trip for high water temperature c. Providing necessary warning system and other safeties as contemplated in relevant ISS d. Fuel shutt off facility at over speed. iv. Fuel Pipe: Oil resistant flexible hoses & 25mm dia or nearest size MS pipe as per manufacturers’ requirement for fuel line extension with regulator valve. v. Alternator a. Make :As specified in material list . b. Type : Self exited and self regulated c. Capacity : 750KVA at 0.8PF d. System of Voltage : 3phase, 415V e. Speed : 1500rpm f. Voltage regulation band : + or -1.00% of rated voltage g. Insulation : Class F/H h. AVR : AVR shall be provided with a motorized or solid state potentiometer. i. IP rating of enclosure : IP 23 j. Waveform distortion : No load < 1.5%, non- distorting, balanced Linear load <5% k. Total harmonic factor : Better than 2% l: Standard control panel with suitably rated ACB . The alternator should confirm to IS 4722. Routine tests as per relevant ISS shall be conducted and test reports of the same shall be furnished at the time of delivery. vii. Fuel tank. Integral type fuel tank of adequate capacity . viii. Battery: Required number of suitably rated fully charged battery with leads and terminals as required as per manufacturers’ requirement. ix Operation manual, service manual, list of spares etc x. Acoustic Enclosure a. The DG set shall be supplied along with specially designed, company fabricated (to be fabricated in the same company from where the DG set is delivered) acoustic enclosure to meet the requirements as per CPCB norms of 75dBA @1m at 75%load under free field conditions. b. Sufficient space and clearance shall be maintained inside the enclosure to have optimum serviceability. c. Air inlet louvers shall be designed in such a way as to operate the set at rated load even at 50 degree Celsius enclosure temperature. d. The enclosure shall be powder coated to capable to withstand extreme environment. e. Hardware used shall be of only stainless steel make. f. Insulation material shall conform to IS 8183 specifications for better attenuation. xi. Documents to be supplied. a. Engine manual. b. Spares parts book c. Warranty certificate d. Alternator manual & test certificate 1 set control wiring drawing xii. Installation It shall be installed in the reconstructed concrete bed complying to relevant IS standards, IE rules and as per the direction of the departmental officials. xiii. During the guarantee period, periodical check-up and services as per manufacture's recommendation and repairs shall be arranged . Any spare / component (except consumables like filters and oil) which requires replacement / repair shall be done immediately at free of cost. The Generator should have capacity to withstand blocked load of at least 55%
90.12.7.37:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm
9.1.31:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
OD48685/2023-2024: Supply and Installation of AMF Logic Relay, EC2 Relay in the existing panel board and to made all control wiring with all accessories and make it proper working condition of automatic operation of DG and EB supply. (C&S Make/equivalent)
OD48686/2023-2024:Supply and providing Plug in Relay , 10Amps, 2Pole, 240V AC, suitable for AMF operation with base plate for proper mounting and giving connections etc: as required. (Salzer Make)
OD48687/2023-2024:Supply and providing Auxilary contactor for Control Relay , Type MXO 22E, 2 No: + 2NC:, 415V, L&T make for AMF Operation,
OD48674/2023-2024:Supply, Fixing of Mechanical Inter Lock with 4 NO and 4 NC , in the existing AMF Panel. (L&T make MCX 22-23/equivalent)
OD48682/2023-2024:Supply and providing electronic on delay timer for AMF operation. (Salzer Make/ equivalent)
OD48675/2023-2024:Supply, laying and clamping of 1 no. 2.5 sqmm 8 core PVC/ XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE with the cables, spacing of clamps with factory made clamp not exceeding 60cms, making good the damages , colour washing etc. as required.
OD48672/2023-2024:Charges for conducting load test of 750 KVA DG set at standardized Factory bed as per standard norms and condition. ie in various steps load up to full load for 3 hours & 10% over load for 20 minutes and the rate includes hire and rent of test bed equipment's, labour charges ,loading and unloading and fuel etc. The test certificate should be given the client in standard format.
OD48673/2023-2024:Supply and filling high speed Diesel for generator
OD48689/2023-2024:Supply and providing 12V,15A, Automatic Battery charger suitable for 180Ah Battery, having . Full protection against battery overcharging & reverse polarity. Over voltage, overload & short circuit protection, reverse battery protection. Digital meters for voltage & current display , attery connecting terminals with lead wire, Float and Boost Charging Mode , LED Indication for charger status indication, etc: and giving necessary connections as required .
OD53047/2023-2024:Supply, fabrication and erection of hot air duct to avoid hot air mix with inlet or suction side of DG with CR sheet and weld mesh including cutting, welding and painting etc as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
90.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip
90.17.7.1:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia
90.17.7.9:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm)
SOUBHAGYA ENGINEERING COMPANY
Bidder Name
K K Associates
SOUBHAGYA ENGINEERING COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_916006.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .