Loading…
Loading…
Tender Value
₹3.0 L
EMD Value
₹6,045
Closing Date
1 Sept 2026, 3:00 pm5d left
GMCOM
WEBEL BHABAN
Civil maintenance works at Kharagpur IT Park
2026_WEBEL_1037188_1
WEBEL/EOT/W/26-27/000105
Open Tender
CIVIL WORKS
Item Wise
60 days
WEST BENGAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
₹6,045
Yes
1 Sept 2026
10 Aug 2026
3 Sept 2026
10 Aug 2026
1 Sept 2026
13 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Description | |||||
| 1.01 | SUPPLYING BUBBLE FREE FLOAT GLASS OF APPROVED MAKE
AND BRAND CONFORMING TO IS: 2835-1987. PART(II) Float glass
of approved make | 6.2 | SQM | - | - |
| 1.02 | SUPPLYING BUBBLE FREE FLOAT GLASS OF APPROVED MAKE
AND BRAND CONFORMING TO IS: 2835-1987; CLEAR,
TOUGHENED GLASS CONFORMING TO IS: 2553-1992 (PART-II) 6
MM THICK Float glass of approved make 6mm Thick | 2.3 | SQM | - | - |
| 1.03 | SUPPLYING GLAZING SILICON OF APPROVED MAKE AND BRAND
FOR FIXING OF GLASS ON SUB-FRAME AS PER DIRECTION OF
ENGINEER-IN-CHARGE FOR STRUCTURAL GLAZING/CURTAIN
WALL ETC. GLAZING SILICON FOR FIXING GLASS ON SUB FRAME
Glazing Silicon of approved make | 16 | MTR | - | - |
| 1.04 | SUPPLY AND AFFIXING OPTICALLY CLEAR POLYESTER SUN
CONTROL WINDOW FILM HAVING ACRYLIC PRESSURE
SENSITIVE ADHESIVE ON ONE SIDE & AN ACRYLIC ABRASION
RESISTANT COATING ON THE OTHER, WITH COMPOSITION OF
INFRARED ABSORBING CARBON & FREE FROM ANY OPTICAL
DEFECT. THE FILM CHARACTERISTICS SHOULD CONFORM TO
ASTM E308, ASTM E903, ASTM E84 AND ASHIRAE. THE FILM
SHOULD BE PASTED AFTER PREPARATORY WORKS WITHOUT
ANY CRACKING, DELAMINATION, BUBBLING, DISCOLOURING AND
VARIATION IN TOTAL TRANSMISSION OF LIGHT ACROSS THE
WIDTH AT ANY PORTION ALONG THE LENGTH DOESN'T EXCEED
2% OVER THE AVERAGE INCLUDING SCAFFOLDING & RELEVANT
OTHERS TO COMPLETE IN ALL RESPECT AS PER
MANUFACTURER'S SPECIFICATION & DIRECTION OF ENGINEER -
IN-CHARGE. (NOTE: THIS WORK SHOULD NOT BE EXECUTED
WITHOUT SPECIFIC PERMISSION OF SUPERINTENDING
ENGINEER) NORMAL QUALITY : FILM THICKNESS - 1.0 MIL, GLARE
REDUCTION > 45%, U FACTOR < 1.15 Optically clear polyester sun
control window film | 8.5 | SQM | - | - |
| 1.05 | SUPPLYING AND LAYING TRUE TO LINE AND LEVEL VITRIFIED
TILES OF APPROVED BRAND (SIZE NOT LESS THAN 600 MM X 600
MM X 10 MM THICK) IN FLOOR, SKIRTING ETC. SET IN 20 MM
SAND CEMENT MORTAR (1:4) AND 2 MM THICK CEMENT SLURRY
BACK SIDE OF TILES USING CEMENT @ 2.91KG./SQM OR USING
POLYMERISED ADHESIVE (6 MM THICK LAYER APPLIED
DIRECTLY OVER FINISHED ARTIFICIAL STONE FLOOR/MOSAIC
ETC WITHOUT ANY BACKING COURSE) LAID AFTER APPLICATION
SLURRY USING 1.75 KG OF CEMENT PER SQM BELOW MORTAR
ONLY, JOINTS GROUTED WITH ADMIXTURE OF WHITE CEMENT
AND COLOURING PIGMENT TO MATCH WITH COLOUR OF TILES /
EPOXY GROUT MATERIALS OF APPROVED MAKE AS DIRECTED
AND REMOVAL OF WAX COATING OF TOP SURFACE OF TILES
WITH WARM WATER AND POLISHING THE TILES USING SOFT
AND DRY CLOTH UPTO MIRROR FINISH COMPLETE INCLUDING
THE COST OF MATERIALS, LABOUR AND ALL OTHER INCIDENTAL
CHARGES COMPLETE TRUE TO THE MANUFACTURER'S
SPECIFICATION AND DIRECTION OF ENGINEER-IN-CHARGE.
(WHITE CEMENT, SYNTHETIC ADHESIVE AND GROUT MATERIAL
TO BE SUPPLIED BY THE CONTRUCTOR WITH APPLICATION
SLURRY @1.75 KG/ SQ.M, 20 MM SAND CEMENT MORTAR (1:4) &
2 MM THICK CEMENT SLURRY AT BACK SIDE OF TILES, 0.2 KG/
SQ.M WHITE CEMENT FOR JOINT FILLING WITH PIGMENT. LIGHT
COLOUR Level vitrified tiles of approved brand | 100 | SQM | - | - |
| 1.06 | LABOUR CHARGE FOR FABRICATION AND INSTALLATION OF
COMPOSITE DOOR, WINDOW, PARTITIONS MADE FROM
ANNODIZED EXTRUDED ALLOY ALUMINIUM SECTIONS FOR THE
FOLLOWING UNITS:- GLAZED ALUMINIUM SLIDING WINDOWS
MADE OF EXTRUDED AND ANNODIZED ALLOY ALUMINIUM
SECTIOS, FABRICATIONS, INCLUDING CUTTING TO PROPER
SHAPE AND SIZE, DRILLING AND ALIGNING OF WINDOW
SHUTTER FRAME FITTED WITH IN BUILT LOCKING
ARRANGEMENTS, SLIDING ROLLERS AND OTHER NECESSARY
FITTINGS, FIXTURE, ADHESIVES AND JOINERIES ALONG WITH
EXTRUDED NEOPRINE OR EPDM GASKETING IN BETWEEN
WINDOW FRAME AND MASONRY WORK (WALLS, COLUMN,
BEAM.LINTELS ETC.) AS WELL AS BETWEEN GLASS AND
SHUTTER FRAME FOR FIXING GLASS AND POLYSULPHIDE
SEALANT AND IN BETWEEN SHUTTER AND WINDOW FRAME
WHERE NECESSARY INCLUDING CUTTING TO REQUISITE SIZE
AND FIXING GLASS AS PER DRAWING, SPECIFICATION AND
DIRECTION OF EIC. THE RATE INCLUDES THE HIRE CHARGE OF
ALL TOOLS AND PLANTS, INCLUDING ALL INCIDENTAL CHARGES,
ADHESIVE, JOINERIES SUCH AS SCREW, CLEAT ANGLE ETC. BUT
EXCLUDING THE COST OF EXTRUDED ALUMINIUM SECTIONS,
GLASS, NEOPRENE / EPDM GASKET, LOCKING ARRANGEMENT
AND ROLLERS. OPENABLE / CASEMENT WINDOW. Labour charge | 2.3 | SQM | - | - |
| 1.07 | LABOUR CHARGE FOR FABRICATION AND INSTALLATION OF
COMPOSITE DOOR, WINDOW, PARTITIONS MADE FROM
ANNODIZED EXTRUDED ALLOY ALUMINIUM SECTIONS FOR THE
FOLLOWING UNITS:- FULLY GLAZED SINGLE LEAF REAMLESS
SWING DOOR MADE OF ANODIZED ALUMINIUM ALLOY
EXTRUSIONS FABRICATION AFTER CUTTING TO PROPER SHAPE
AND SIZE, DRILLING AND ALIGNING FITTED WITH HEAVY DUTY
HYDRAULIC ACTION FLOOR SPRING WITH TOP PIN ASSEMBLY
AND FITTED WITH INBUILT LOCKING ARRANGEMENT AND ALL
OTHER NECESSARY FITTINGS, FIXTURE, ADHESIVES AND
JOINERIES, CUTTING THE GLASS TO REQUISITE SHAPE AND
SIZE MOUNTING THE EDGES FOR FITTING THE SAME WITH DRY
SET NEOPRINE/EPDM GASKET. THE RATE INCLUDES THE HIRE
CHARGE OF ALL TOOLS AND PLANTS, ADHESIVE, JOINERIES BUT
EXCLUDES THE COST OF EXTRUDED ALUMINIUM SECTIONS,
GLASS, PANEL BOARDS EPDM GASKET, LOCKING
ARRANGEMENT, WEATHER GASKET / WOOL PILE, FLOOR
SPRING, TOP PIN, HANDLE, TOWER BOLT Labour Charge | 6.2 | SQM | - | - |
| 1.08 | SUPPLYING SOLID FLUSH TYPE DOORS OF COMMERCIAL
QUALITY, THE TIMBER FRAME CONSISTING OF TOP AND
BOTTOM RAILS AND SIDE STYLES OF WELL SEASONED TIMBER
65MM WIDE EACH AND THE ENTIRE FRAME FITTED WITH 37.5MM
WIDE BATTENS PLACES BOTH WAYS IN ORDER TO MAKE THE
DOOR OF SOLID CORE AND INTERNAL LIPPING WITH GARJAN OR
SIMILAR WOOD VENEERS USING PHENOL FORMALDEHYDE AS
GLUE ETC. COMPLETE, INCLUDING FITTING, FIXING SHUTTERS
IN POSITION BUT EXCLUDING THE COST OF HINGES AND OTHER
FITTINGS IN GROUND FLOOR, 35 MM THICK SHUTTERS (SINGLE
LEAF) 35 mm thick shutters (single leaf) | 14 | SQM | - | - |
| 1.09 | TAKING OUT SHUTTER OF DOOR AND WINDOW, DISMANTLING
BY PARTS (FOR REPAIR OR REPLACEMENT OF DAMAGED
PARTS) , REASSEMBLING AND REFITTING AND REHANGING
SAME WITH OLD FITTINGS BUT WITH NEW SCREWS AS
NECESSARY. (WHERE DIFFERENT PARTS OF SAME SHUTTER
ARE RENEWED UNDER DIFFERENT ITEM, PAYMENT UNDER ITEM
73 WILL BE MADE ONCE ONLY). Repair or replacement of damaged
parts | 12 | SQM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.02 MB
BOQ_2547695.xls
BOQ • 0.27 MB
DateCorrigendum1EOT105.pdf
PDF • 0.44 MB
TechnicalCorrigendumEOT105.pdf
PDF • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].