Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 27 CHITRAKOOT ENCLAVE NEAR ANURAG NURSARY DEHRADUN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹14.7 L+₹1.1 L (7.97%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
23 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVN OF CERTAIN MINOR WORK DEAL AND IRDE UDER GE(I) RND DEHRADUN
2022_MES_541271_1
GE(I)RND/9157/E8/22-23
Open Tender
Civil Works
Item Rate
180 days
DEAL DEHRADUN
Class E Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹30,000
Yes
8 Sept 2022
27 Jul 2022
25 Aug 2022
27 Jul 2022
23 Aug 2022
9 Aug 2022
27 Jul 2022 - 9 Aug 2022
Amount
Demolition of brick or stone masonary built in cement mortar including pre cast articles complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed
Demolition of cement concrete in ground floors and pavings n. Exc 15cm thickness (below or above) ground level complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M & L For Separating, scraping and cleaning of reinforcement complete all as specified and directed.
M&L for 18 to 16 mm thick Granite Slab of any colour machine cut in skirting/dado laid over cement screed in cement morter 1:3 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and directed . Note :- Coloure of granite stone stone slab as approved by GE
M&L for Brick work with sub class B bricks, straight or curved on exc 6m mean radious built in cement mortar (1:6) complete all as specified and directed.
M&L for Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed
M&L for Preparation of new plastered surfaces of wall / ceiling and applying two coats of Cement base paint) complete all as specified and directed..
M&L for RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in foundations, including rafts, footing, foundation beams, plinth beams, bases for columns etc, basement slab, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using using 20mm graded crushed stone aggregate as in column ,pillars, piers,posts and struts complete all as specified and directed.
M&L for Use & waste for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter including fair finished surfaces complete all as specified and directed.
M&L for Use and waste of formwork to sides of concrete pillar, columns, posts strutts complete all as specified and directed.
M&L for Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n' exc. 1.5 m in depth and getting out in any type soil complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc 50 metre & depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and directed.
M&L for Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete complete all as specified and directed.
M&L for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed..
M&L for Stainless steel grade 304 letter of size 300mm x 50mm x10mm fixed on granite stone slab complete all as specified and directed.
S&F of 8 mm thick venext premium planks designer fiber cement board of fire resistance complete and fixed to gate/wall cladding as per manufacture instruction complete all as specified and directed. Make :- Vnext or equivalant Note :- Coloure of fiber cement board as approved by GE
Taking down Chowkats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n. exc. 4.00 sqm each including removing to store complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each including removing to store complete all as specified and directed.
M&L for Powder coated aluminium Anodized frame for doors , windows, ventilators, partition wall with one or more rebates including joining cleat for fixing etc complete all as specified. (Minimum thickness of powder coating not less than 50 micron) complete all as directed
S&F powder coated of any colour aluminium door shutters, aluminium section like lock rail, bottom rail 115x38/40 mm and top rail and vertical rail 100x38/40 mm including necessary jointing cleats/glazing clipx, rubber neorene paking, handles 02 Nos in each door, locking arrangment, aluminium snap beading screw etc, complete all as specified and directed. (panels likes prelaminated particle board / sheet glass shall be measured and paid seprately)
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150 mm size complete all as specified and directed.
S&F floor door stopper double leg of aluminium alloy body of 70 mm length with aluminium base plate of size 50 mm x 40mm complete all as specified & directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
M&L for 4.8mm thick glass fixed in aluminium door/window/partition fixed with rubber gasket and aluminium beading complete all as directed.
RCC M -25 (Design Mix) using using 20mm graded crushed stone aggregate as in slab supported on walls beams and columns in floor, roof, landing and in shelves and the like complete all as specified and directed.
M&L for Use & waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick for fair finish surface complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key, scdrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick plastering in CM (1:6) on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed.
M & L for 5 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:3 finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for Preparation of new surfaces of wall / ceiling and applying two coats of cement based paint including scaffolding complete all as specified and directed.
M&L for Preparation of new plastered/un-plastered surfaces of wall and applying three coat of white wash on walls complete all as specified and directed.
M&L for Vitrified ceramic tiles 10 mm thick polished,area of each tiles exc 0.36 Sqmn butt not exc 0.42 Sqm laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including 15 mm thick screed bed or bedding layer in CM 1:4 complete all as directed.
M&L for Vitrified ceramic tiles 10 mm thick polished,area of each tiles fixed in vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including 10 mm thick rendering in CM 1:3 complete all as directed.
M&L for Granite 25 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for suspended false ceiling system using chicago metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as directed. Make :- EVEREST or other equivalent as approved.
M&L PVC SHEET WALL PANELLING of thickness 5mm consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm thick prelam PVC sheet. The panel & strips shall be of 600 kg / cbm density manufactured by an ISO-9000 certified company. The strips should two PVC strips. The PVC strip shall be fixed to the wall using 65mm long M.S screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a U Channel at top, bottom and side edges and strips of 5mm thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement complete all as specified and directed (Note- Including all nesscesary fittings and scafolding for heighted site)
Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
S&FMS Plates (plain or chequered) Fe-290 (Gde- E- 165) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S&FMS WORK as in Roof trusses (framed) Fe 410-W (Gde -E-250) quality-A, trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle channel or flat sections) including distance pieces cleats etc. complete all as specified and directed.
M&L forHard core of broken stone gauge not exceeding 63mm, deposited, spread and levelled in layer not exceeding 15 cm thick watered & rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-1 (using 40 mm graded stone aggregate) as in sub base / plinth protection & finishing the surface even and smooth with out using extra cement complete all as spd and directed.
M&L forMachine cut Kota stone slab flooring 20-22 mm thick laid over and including 20mm screed bed in CM 1:4 laid and jointed with grey cement slurry, mixed with pigment to match the shade of slab including grinding,rubbing and polishing mirror finish complete all as specified and directed
Supply only liquid water proofing compound complete all as specified & directed.
M&L for Pre- painted colour galvalume aluminium Zinc coating GI based corrugated tile profile steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed
M&L for Pre- painted colour galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed
S&F 11 to 15mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other end, or screwed both ends, each screwed and to fitted with washers and one hexagonal or square nut exc 10 cm and n exc 15 cm complete all as specified and directed
M & Lfor 75 mm thick Plain Cement concrete type D- 2, 1:4:8 (40mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for Rubberised polished glossy finish precast coloured cement concrete Interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade complete with & including 50mm thick sand cushioning layer etc complete, all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, coping, benching, kneelers, apex stone, bed plates, kerbs, etc. including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as directed.
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 25 mm dia, concealed conduit wiring in walls and surface with GI saddles,GI screws, rawl plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly for one light/Fan point controlled by one Switch complete all as specified and directed. Make of cable: Havells/Polycab/L&T, Make of conduit: Finolex/Polycab/Supreme
All as per item No 59 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed. Make of cable: Havells/Polycab/L&T, Make of conduit: Finolex/Polycab/Supreme
M&L sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed Make of cable: Havells/Polycab/L&T, Make of conduit: Finolex/Polycab/Supreme
M&L sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 16 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 16 Sqmm as earth continuity conductor complete all as specified and directed Make of cable: Havells/Polycab/L&T, Make of conduit: Finolex/Polycab/Supreme
S&F Modular switch single pole one way 6 amp complete all as specified and directed Make -Legrand/Anchor Penta/Havells
S&F Modular switch single pole one way 16 amp complete all as specified and directed complete all as specified and directed. - Legrand/Anchor Penta/Havells
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete all as specified and directed Make -Legrand/Anchor Penta/Havells
S&F ceiling rose 3 plates polycarbonate, isolated body complete all as specified and directed . Make - Legrand/Anchor Penta/Havells
S&F 20W complete batten fitting, efficacy 100 lumen/watt with all accessories complete all as specified and directed . (Make-LCTLN-20-CDL of Crompton or equivalent in Havells/Philips)
Supply and Fixing Sheet metal earth plug, socket, single pole and neutral with single pole MCB 20/32 Amps 240 volts complete all as specified and diected Make: Indoasian/Legrand/Havells
S&F MCB distribution board SPN, 240 volts, 12 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. complete all as specified and directed. Make: Legrand or other equivalent in Havells/L&T/Schneider/ IndoAsian as approved by GE.
S & F MCB SP 240 volts 6 to 32 Amps 'C' curve having breaking capacity 10 KA, IP-20 protected terminals,biconnect lower termials, sliding bottom clamp, integrated label holder, colour coded on/off indication on dolly complete all as specified and directed. Make - Legrand cat ref no 408587/90/92/93/94/95 or other equivalent make in L&T/C&S.
S&F MCB SPN 240 volt 6 to 32 Amp 'C' series 10 KA breakng capacity , including connection with suiatble size aluminium/copper lugs complete all as specified and directed. Make: Cat Pt No. 811144/46/48/49/50/51 of indoasian or other equivalent make in Legrand or ABB
Supplying, Laying, testing and commissioning of XLPE cable insulated,IS 7098 (Part-I)-1988 marked screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100V grade cross section area 6 Sqmm 2 core cables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection, with busbar/MCCB/DB's & testing complete, all as specified and directed by Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, GI pipe and brick protection shall be measured and paid separately )
M&L for Un-reinforced precast concrete cable cover class LV type1 flat size250 mmx 150 mm x40 mm as protection to under ground cable laid dry flat adjjoining each other complete all as specified and directed
Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of larntent/ street light fitting including PCC work complete all as specified and directed . Make of pipe TATA / Jindal / Swastik / Prakash / BST or any other ISI marked make approved by GE. (Note : PCC work shall be measured and paid seperatly under Sch "A' relevent item)
Supply and filling sand with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE: - Punned thickness shall be measurement & paid.
Supply, fixing & testing in replacement of UNSV post top light fitting with 25 W LED post top lantern complete accessories to be fixed on gate post including connecting the fitting to control switch at the bottom of the pole with using 2.5 sqmm two single core PVC insulated and unsheathed copper conductor cable with suitable size of LED post top lantern GI tubing and grouting the tubing to the gate post including PCC complete and making good the disturbed surfaces all as specified and directed by Make: Havells Cat Pt No. CORALPT25WLED757PSYMTOPC or equivalent in CG/Bajaj
Taking down old unserviceable MS junction boxes from the gate post with disconnecting all connections and supplying and fixing in position new pole box made of thermoplastic Polycarbonate having IP65/IP66 degree of protection (shock proof, jet water proof and acid resistive). The gasket should be internally embedded, and made of Polyeutherene. The boxes shall be tested as per IEC 60670-2/60670-22. The boxes shall have self threaded holes & provision for mounting din rail. The lid should be hinged type with sealing screw. The screw should be of stainless steel so that there is no corrosion. The boxes should withstand temperature of -40c to +120c. The glow wire test should be conducted at 960 c or 750 c and material should be flame retardant & self extinguishing. UL subject 94, V-0. The boxes should be free from toxic substances like hal ogen and silicon. The boxes should have suitable pre-moulded lnock out/or plan wall depending on requirement. Box dimension shall not be less that 155x210x92 MM (LXBXH). Box shall be suitable for 6 Sqmm cables including one no. MCB SP 230 volts 6 amps of Make Havells/Legrand/ABB and connectng the bus bar to cables with using suitable GI nut, bolts and washers and aluminium lugs etc fixed on pole using 30x5 mm FI clamps, nuts, bolts & washers complete all as specified and directed. Make : Hensel Cat Pt No. DK1610G or equivalent in legrand/Schneider
UNOQ Private Limied
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .