Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC ARAYAKKAD PULLULLI PALAKKAD 678623 | PALAKKAD | PALAKKAD | KERALA | 678623 | L1 | Accepted-AOC l1 contract date 01/0/25 |
Tender Value
₹12.7 L
EMD Value
₹31,765
Closing Date
10 Jan 2025, 6:00 pmClosed
AJITH ANTO P
O/o Office of the Assistant Executive Engineer, Electrical Irrigation Sub Division Chalakudy
GENERAL-MI Palakkad -Thudikkal LIS - Transformer repair -Urgent repair of burnt 500 KVA oil cooled outdoor transformer and substation at Thudikkal LIS -HT-ElectricalWork-retender
2024_Irrig_718727_4
C-ETN-DEC/EL/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Palakkad
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹31,765
22 Apr 2025
31 Dec 2024
13 Jan 2025
31 Dec 2024
10 Jan 2025
31 Dec 2024
Amount
500 KVA transformer repair
OD128460/2024-2025:Dismantle all the electric connection from the damaged 500 KVA out door type oil cooled transformer after taking mandatory safety precaution in HT line. Removing the fencing around the transformer yard , lower the transformer safely, by crane , necessary equipment and labour, take out the transformer very carefully and loading into the vehicle .
OD128461/2024-2025:Dismantle all the electric connection from the damaged AB switches , lightning arresters , DO fuses and other porcelain insulators and then bring down the all items safely and keep it in a very safe place.
OD128462/2024-2025:Scrapping , cleaning the existing 4 pole structure ie,I channel , C channel and other supporting channels and painting with two coats of synthetic enamel paint over a coat of red oxide primer after renewing the GI nuts and bolts etc as required.
OD128463/2024-2025:Scrapping , cleaning the existing fencing of the transformer yard and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc as required.
OD128576/2024-2025:Carry out preliminary inspection and tests , diagnosing the fault of 31 years old 500 KVA transformer .Remove the transformer top cover , draining out the oil ,dismantle bush stem , remove core coil assembly and cleaning the tank. Remove the whole primary and secondary winding , cleaning and resetting the core . Rewind the whole transformer coil firmly by using required size enamel insulated copper winding wire after providing required insulating materials like as craft paper , letheroid paper etc and oven drying the transformer core coil assembly . Scraping , cleaning and painting the transformer tank with two coats of synthetic enamel paint over a coat of red oxide primer after doing the necessary welding work. Reset the transformer and covering the top cover etc with good quality gasket and sealing washers etc. Fill required quantity transformer oil and providing silica gel breather bottle and require all other accessories. After completion of all repair work ,mandatory test should be done and ensure the measuring values are as per existing norms and standards with the presence of departmental officials / engineers. ( Deducting burnt copper scrap winding from this work ). Includes to and fro conveyance charge.
OD128467/2024-2025:Unloading the repaired 500 KVA transformer on the side of road near the transformer yard, then lead to yard, using the crane and labours without any damage and raise to plinth and place.
13.10:Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
13.11:Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
13.13:Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire. 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KSA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
OD209131/2024-2025:Supply and providing 11 KV AB switch with handle set fixed on the existing MS channel frame work.
OD209133/2024-2025:Supplying and erection of three piece polymer 11 KV DO fuse and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
OD209333/2024-2025:Earthing with G.I. earth plate 1200*1200*12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
OD128776/2024-2025:Supplying and laying 40 mm X 10 mm GI strip at 0.60 meter below ground as strip earth electrode, including connection/ terminating with suitable nut, bolt, spring, washer etc. as required._
OD128777/2024-2025:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps , spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run / vertical run ) 40 x 10 mm GI strip
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.39.1:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm
90.12.41.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
OD128784/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 4 sq. mm
OD209373/2024-2025:Supply and fixing 100/5A class 5P 10 Neutral CT for up to 500 KVA transformer
OD209374/2024-2025:Supply and providing one number earth fault Relay ( MC 12 ) or equivalent
OD209375/2024-2025:Supply and providing test terminal block.
OD209378/2024-2025:Supply and drawing the 12 core 2.5 sq mm PVC insulated ISI marked copper cable and giving necessary connections .
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
OD209387/2024-2025:Providing and laying in position graded stone aggregate 40 mm nominal size in transformer yard etc as required.
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
OD128787/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps for interconnecting the control devices/ equipments including providingsuitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring,keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.-2.50 sq mm single run with required sockets.-
90.14.10.18:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
OD207675/2024-2025:MCCB Accessories Supply and fixing one number earth leakage Relay up to 800A with CBCT.
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.14.11.11:MCCB AccessoriesSupply and fixing one number under voltage release for all voltage range up to 630A MCCB.
OD207690/2024-2025:Supply and fixing CURRENT TRANSFORMER - 800/5 A, 5 VA, accuracy class 1, Tape wound Metering CT-
OD128788/2024-2025:Supply and providing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
OD128789/2024-2025:Supply and providing LED indicators for all voltage ranges - Blue Colour
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD209417/2024-2025:Supply ,testing and installation of HT TOD Meter -/5 3P 4 wire class 0.2s Uni direction.
OD209418/2024-2025:SITC of 11 KV CTPT(out door- Oil cooled 5/5 to 25/5 ) of accuracy class 0.2 s with required supporting accessories.
OD207692/2024-2025:Supply , Conveyance and fitting 630/800 A, HRC Fuse Base with suitable HRC Fuse
OD207734/2024-2025:Supply , Conveyance and fitting 315/400 A, 2 Way neutral links in the existing Meter box.-
OD128471/2024-2025:Provision for liaison works for obtaining statutory approval from the electrical inspectorate / departments.
OD128472/2024-2025:Fees to be paid to KSEB / KSELB / TMR towards scrutiny, meter testing & inspection ( actual amount will be reimbursed on production of original documents )
Bidder Name
AMAZON ELECTRICAL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1143841.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .