DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 21, GANDHINAGAR
M&R to EI in Various Types Of Residential Quarter at Sector-19 & 20, Gandhinagar (As Per Requirement For Twelve Month)
307303
02/05 OF 2026/2027
Open
Electrical and Maintenance Works
Works
Gandhinagar
8 documents required · 8 mandatory
₹900
DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 21, GANDHINAGAR
₹10,000
21 May 2026
21 May 2026
21 May 2026
3 Jun 2026
21 May 2026
120 days
Name of Work M&R to EI in Various Types Of Residential Quarter at Sector-19 & 20, Gandhinagar (As Per
Requirement For Twelve Month)
Fund Head : 2216 Housing M&R SR
Sr. No. Item No. Particulars. Qty. Rate Amount
Signature of Contractor Deputy executive Engineer
C.P Electrical R & B Sub Dn
Name Of Work :- M&R to EI in Various Types Of Residential Quarter at Sector-19 & 20, Gandhinagar (As Per
Requirement For Twelve Month)
Item Estimated Rate in Rs.
Item Description Unit Amount in Rs.
No. Quantity in Figure In Word
Replacing old and u/s by Point wiring for Light / Bell with
2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are
of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of
pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected
1 125 pts on PVC / Metallic/Wooden box, single mounting base 410.06 pt
frame covered with textured/metallic/white front plate
modules erected on / in wall / ceiling as per pipe erected,
with necessary Lamp holder/ceiling rose / H.D.Connector
as directed.(j) in existing pipe erected concealed in
wall/ceiling complete Cat. III
Replacing old and u/s by Point wiring for Tissino / Modular
secondary light point with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires, in below
type of pipe to be erected complete with earth continuity Rupees One
and necessary connection with primary light with Hundred Twenty
accessories erected on Metal / PVC / wooden box And Paise
covered with 3 mm thick PC(Polycarbonate) / Acrylic Nineteen Only
sheet for open / concealed wiring. with necessary Lamp
holder / ceiling rose / H.D.Connector as directed. (j) in
existing pipe erected concealed in wall/ceiling complete
Replacing old and u/s by Point wiring for Light / Bell with
2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are
of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of
pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected
on PVC / Metallic/Wooden box, single mounting base Rupees Two
frame covered with textured/metallic/white front plate Hundred Five
modules erected on / in wall / ceiling as per pipe erected, And Paise Three
with necessary Lamp holder/ceiling rose / H.D.Connector Only
as directed.NOTE:-2 For point wiring in bathroom and
W/C and washbasin area in residential quarters reduce
overall rate by 50% of point wiring for light.(j) in existing
pipe erected concealed in wall/ceiling complete Cat. III
Replacing old and u/s by Point wiring for FAN with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and Rupees Five
accessories with earth continuity of following type erected Hundred Fifty Six
on PVC / Metallic/Wooden box, single mounting base And Paise Fifty
frame covered with textured/metallic/white front plate One Only
modules erected on / in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as directed.(j)
in existing pipe erected concealed in wall/ceiling complete
Replacing old and u/s by Point wiring for on board Looped
Plug with 6A Modular type switch & 5 pin socket erected
on PVC / Metallic/Wooden box, single mounting base
5 30 pts 257.55 Seven And pt
frame covered with textured / metallic/white front plate
Paise Fifty Five
modules erected on / in wall / ceiling with following type
accessories Cat. III
Replacing old and u/s by Point wiring for Two Way
Controlled Light Point with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires erected in
below type of pipe with 6A Modular type switches and Rupees Five
following type of accessories erected on PVC / Hundred
Metallic/Wooden box, single mounting base frame Fourteen And
covered with textured / metallic/white front plate modules Paise Nine Only
erected on / in wall / ceiling as per pipe erected. with
necessary batten/angle holder or ceiling rose or
H.D.Connector as directed. (j) in existing pipe erected
concealed in wall/ceiling complete Cat.III
Replacing old and u/s by Providing following type of
Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation
directed by Engineer In charge.
(1)One No. SP 6 Amp. Cat.III Rupees One
150 nos 151.50 Each
(2) One No 5 pin plug Cat.III Rupees One
150 nos 151.50 Each
(5) Electronic hum Free steps EME Fan regulator
50 nos 398.95 Each
Eight And Paise
Ninety Five Only
(7) Blank Plate Single Cat.III Rupees Twenty
25 nos 25.25 Each
(9) 16 Amp. SP one way switch Cat.III Rupees One
70 nos 180.79 And Paise Each
(10) 6/16Amp. Universal socket Cat.III Rupees One
70 nos 199.98 Nine And Paise Each
(11) 6 Amps. Bell Push Cat.III Rupees One
15 nos 151.50 Each
(12) 6Amp. / 16 Amp. Two Way switch Cat.III Rupees One
30 nos 170.69 Seventy And Each
Paise Sixty Nine
(13) 6A/10A/16A/20A/25A/32A Single pole Modular MCB Rupees Three
Switch Cat.III Hundred Ten
5 nos 310.07 Each
(21) Foot Light as per colour requirement with concealed
box, modular accessories, acrylic glass cover with suitable
Hundred Sixteen
20 nos LED watt with all accessories as per following module (a) 316.13 Each
Two modules Cat-III Old-5 New-15
(24) Batten Holder/Angle Holder with modular frame with Rupees Sixty
50 nos metal ring. Cat-III 64.64 Four And Paise Each
Sixty Four Only
Replacing old and u/s by Providing & erecting following
type of Modular Type Accessories with necessary
connection. As desired by Engineer In charge
(1) 6 Amp. SP one way switch Rupees Twenty
75 nos 27.27 Each
(2) 16 Amp. SP one way switch Rupees Fifty
50 nos 51.51 One And Paise Each
(3) 6/16Amp. Universal socket
50 nos 82.82 Two And Paise Each
Eighty Two Only
(4) 6 A socket Rupees Forty
40 nos 42.42 Two And Paise Each
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed
(a)20 mm Rupees Twenty
1000 mtrs 24.24 mtr
(b)25 mm Rupees Thirty
Three And Paise
200 mtrs 33.33 mtr
Providing & erecting PVC Corrugated Flexible Conduit
10 with required nos. of coupling, PVC bushes, Check-nuts
etc. complete of following sizes.
(1) 20 mm Rupees
40 mtrs 17.17 mtr
Paise Seventeen
Supplying & erecting UPVC Mini trunking (PVC Casing-n-
Capping) having double-locking arrangement with
grooves, trunking of size not below 12.5 mm in height as Rupees Twenty
11 40 mtrs per IS with accessories of PVC/Resin polypropylene not 22.22 Two And Paise mtr
below 1.8 mm thick duly sealed in joint & erected on wall / Twenty Two Only
ceiling of following size . (1) 20 mm
Replacing old and u/s by Supplying and laying UPVC
cable trunking system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and flame proof
12 10 mtrs confirming BS with necessary end caps Internal and 277.75 mtr
external bend, flat bends, coupler, tee etc..All necessary
accessories and measuring of following sizes (1) 75 mm x
Replacing old and u/s by Providing and erecting Mains
with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
13 to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
(E) in existing pipe (a) 2 wire 1.5 sq. mm Rupees Forty Six
400 mtrs 46.46 And Paise Forty mtr
(E) in existing pipe (b) 2 wire 2.5 sq. Mm Rupees Sixty
500 mtrs 62.62 Two And Paise mtr
Replacing old and u/s by providing and erecting Mains
with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size
(E) in existing pipe (a) 2 wire 4 sq. Mm Rupees Eighty
150 mtrs 86.86 Six And Paise mtr
Eighty Six Only
(E) in existing pipe (b) 2 wire 6 sq. Mm
80 mtrs 121.20 mtr
(E) in existing pipe (c) 2 wire 10 sq. mm Rupees Two
(use earth wire of 4 sq.mm ) Hundred Eleven
40 mtrs 211.09 mtr
(E) in existing pipe (h) 4 wire 6 sq. Mm
150 mtrs 240.38 mtr
And Paise Thirty
(E) in existing pipe (i) 4 wire 10 sq. mm
(use earth wire of 4 sq.mm )
150 mtrs 398.95 mtr
Eight And Paise
Ninety Five Only
Replacing old and u/s by Supplying and erecting Flexible
PVC insulated multi strand multi core 1.1 kv grade ISI
marked copper wires of following size to be erected as
(e) 1.50 Sq.mm 3 core round PVC sheathed Rupees Forty Six
250 mtrs 46.46 And Paise Forty mtr
(h) 2.50 Sq.mm 3 core round PVC sheathed
200 mtrs 77.77 mtr
Replacing old and u/s by providing and erecting Mains
with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in existing
pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
(e) One wire 6.00 sq. Mm Rupees Fifty Six
40 mtrs 56.56 And Paise Fifty mtr
(f) One wire 10.00 sq. Mm
25 mtrs 91.91 One And Paise mtr
Ninety One Only
(h) One wire 25.00 sq. mm Rupees Two
10 mtrs 236.34 mtr
Thirty Four Only
Providing & Erecting 3mm thick Polycarbonate (PC) Rupees Three
17 8000 sq.inch sheet with grooving as directed 3.03 And Paise Three sq.inch
Providing & Erecting 3mm thick acrylic Sheet with Rupees Three
18 7000 sq.inch grooving as directed 3.03 And Paise Three sq.inch
Replacing old and u/s by Providing & erecting Switch
board for Computer or electric apparatus consisting of
following modular type accessories mounted with PVC /
Metallic concealed/open box with single mounting base Rupees One
frame covered with textured/metallic /white front Thousand One
19 2 nos plate,modules erected with necessary connections as 1,133.22 Hundred Thirty Each
directed Three And Paise
1 no. 6A/16A universal plug-switch combined. Twenty Two Only
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories Cat. III
20 Providing & erecting ISI marked 3 pin plug top.
50 nos 21.21 One And Paise Each
Twenty One Only
(b) for 15/16A, 240 V Rupees Thirty
80 nos 32.32 Two And Paise Each
Thirty Two Only
Replacing old and u/s by providing and erecting
Decorative call bell Ting-tong box type 250 volts complete
21 20 nos erected 71.71 Each
Replacing old and u/s by Supplying and erecting LED
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a
heat sink shall be made of thick sheet Steel conforming to
IS: 513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more
than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Tube Light with integral driver (i) 5-10 Watts, Surge-2 Rupees One
KV, IP-20, conventional 1 to 2 feetCat-lll Hundred Sixty
60 nos 165.64 Each
Sixty Four Only
(A) Tube Light with integral driver (iv) 22-24 Watts, Surge - Rupees Three
2KV,IP-20, conventional 4 feet Cat-lll Hundred
200 nos 373.70 Seventy Three Each
(A) Tube Light with integral driver(v) 36-40 Watts, Surge-2 Rupees Five
KV, IP-20, conventional 4 feet Cat-lll Hundred Thirty
25 nos 535.30 Each
Supplying and erecting led lamps with following wattage
capacity of 220 to 240 voltage, minimum 15000 burning Rupees One
hours life, 500 V in built-surge protection,Polycarbonate Hundred Eighty
23 400 nos diffuser, mounting suitable for E14 / E27 / B22 lamp 188.87 Eight And Paise Each
holders, pf >= 0.5 Eighty Seven
(A) LED Lamps integral type, with PC diffuser suitable Only
LAMP holder (iii) 10 to 15 watts cat-III
Replacing old and u/s by Supplying and erecting LED
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a
heat sink shall be made of thick sheet Steel conforming to
IS: 513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting clips
50 nos complete.IP20 (iii) 16-20 watts, Surge-2 KV Cat-lll 589.84 Each
Eighty Four Only
(D) LED Strip Light (ii) Minimum 7.2W -240 LED per
meter,(2 wire, IP-65) with non integral suitable Driver
25 mtrs complete Cat-lll 220.18 mtr
(F) Spot Light 425 Lumens, Surge-2KV (ii) 8 to 11 Watts Rupees One
Cat-lll Thousand Three
15 nos 1,367.54 Each
Paise Fifty Four
(H) Mirror Light 9 Watts, wall mounted minimum 1 feet Rupees Three
long Hundred Twelve
10 nos 312.09 Each
(I) Adjustable spot light with COB led having aluminium
reflector of following wattage
(ii) 12 Watts Cat-lll
30 nos 966.57 Each
Fifty Seven Only
(iv) 30 Watts Cat-lll Rupees Two
2 nos 2,161.40 Hundred Sixty Each
Replacing old and u/s by providing and erecting Miniature
circuit breaker single pole 6A to 25A suitable to operate
25 40 nos on 240 V A.C. system and having breaking capacity 10 112.11 Each
KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
Replacing old and u/s by Providing & erecting 240 V MCB
double pole switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity
(B) 40 Amp. Cat.III Rupees Three
15 nos 330.27 And Paise Each
Replacing old and u/s by Providing & erecting 415 V MCB
Four Pole for Motor & Inductive Load (C Curve) having
27 15 Nos 10KA breaking capacity & confirms to IS :8828 in existing 737.30 Each
box having following capacity (c)63 Amp. Cat.III
Paise Thirty Only
Replacing old and u/s by Providing and Erecting Plastic Rupees One
enclosure fitted with DIN rail suitable for incorporating Hundred Eight
28 15 nos 108.07 Each
Three /Four nos. MCB And Paise
Replacing old and u/s by Providing and Erecting Sheets
steel powder coated enclosure suitable for incorporating
One/Two nos. MCB.
29 25 nos 176.75 Seventy Six And Each
Replacing old and u/s by Providing and erecting Sheet
Steel powder coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral link, earth bar
30 and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
(A) single phase incoming and horizontal single phase Rupees One
outgoing (b) sheet steel double door (IP-43)(iii)8 way Thousand One
3 nos 1,152.41 Hundred Fifty Each
(B) three phase incoming and single phase horizontal type Rupees Three
outgoing Per phase isolation type (PPI) (b) sheet steel Thousand Four
double door (iii)8 way Hundred Twelve
1 nos 3,412.79 Each
Replacing old and u/s by providing and erecting Approved
make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity Rupees Two
of 10 KA and suitable for operation on single phase 240 Thousand Two
31 15 nos V,50Hz. having characteristic of quick action & tripping 2,235.13 Hundred Thirty Each
with all advance feature & do not incorporate any Five And Paise
electronic component. for following Max. rating erected as Thirteen Only
directed (ii) 40Amps. DP Cat. III
Replacing old and u/s by Providing and erecting Approved
make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity
of 10 KA and suitable for operation on 3 phase and neutral
32 5 nos 415V,50Hz. having characteristic of quick action & tripping 3,040.10 Each
with all advance feature & do not incorporate any
electronic component for following Max. rating erected as
directed. (iii) 63 Amps. FP Cat. III
Providing and erecting HOT deep Galvanised iron strip
wire 8 to 16 SWG.
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for
following type of applications with chamber and heavy
duty cover. (A)(approved make OEM has to submit test Rupees Four
certificate including value of earth resistance of installation Thousand Five
34 3 nos duly stamped and signed by agency and officer Incharge 4,591.46 Hundred Ninety Each
has to ensure the value of earthing resistane mentioned in One And Paise
test Certificate) & having back filling compound of (B) Forty Six Only
Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must
be submitted by Agency. (a) For Electrical Installation up
to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Replacing old and u/s by Providing & erecting Approved
make Ceiling Fan with double ball bearing with Condenser
230 volt A.C.50 Hz. 900 mm sweep complete having
35 5 nos 1,982.63 Hundred Eighty Each
Aluminium blades, canopy erected complete. [ Make shall
be approved by Engineer in Charge]
Sixty Three Only
Replacing old and u/s by Providing & erecting Approved
make Power Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C. 50 Hz
36 25 nos 1200 mm sweep complete having 3blades with aluminium 1,948.29 Each
Eight And Paise
blades with , canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by Engineer in charge))
Replacing Old & u/s by new Providing 2.5mm.thick
Rupees Eighteen
laminated acrylic sheet to cover the fan hook or Fan box.
37 15 nos 18.18 And Paise Each
Providing & erecting fresh air fan 250 mm dia with square Rupees One
frame make of ABS body with louvers Cat.II Thousand Five
38 3 nos 1,559.44 Hundred Fifty Each
Forty Four Only
Replacing old and u/s by Supplying & erecting approved
make low noise decorative exhaust fan having square
frame ABS body with inbuilt lowers & square
39 19 nos 1,703.87 Hundred Three Each
frame.200mm with 1350RPM Cat.II
And Paise Eighty
Replacing old and u/s by Supplying & erecting single
phase approved make industrial exhaust fan suitable for Rupees Two
medium duty ring mounted low noise operation suitable for Thousand Fifty
40 5 nos 2,054.34 Each
medium duty having following dia size and maximum Four And Paise
speed in RPM[A] 305 mm dia 900 RPMCat.II Thirty Four Only
Replacing old and u/s by Supplying and erecting approved
make oscillating type bracket fan A.C. 23OV. 50cy/s
400/450 mm sweep wall mounted with height adjustment
41 5 nos 2,534.09 Hundred Thirty Each
and rotary tilting device complete with guard, flexible Core
plug top complete erected with lead wires as directed.
Replacing old and u/s by Supplying and erecting approved Rupees Two
make pedestal fan A.C. 230V. 50 Cy/s. 400 mm sweep Thousand One
42 5 nos oscillating, type and adjustable, height complete with 2,141.20 Hundred Forty Each
guard regulator, & standard lead flexible wires and plug One And Paise
top. Cat.II Twenty Only
RUPEES IN WORDS Rupees Nine Lakh(s) Ninety Eight Thousand Seven Hundred Ninety Three And Paise Four Only
I/We am/are willing to carry out the work at(No above rates allowed) ____________% below ___________________________________
__________________percent (Should be written in figures and words) below the tendered rates mentioned above.
Amount of my/our tender works out as under :
Put to Tender Rs. 998,793.04 Put to Tender Rs.
Deduct ______ % below Rs. _______________ ADD ______ % ABOVE Rs.
In word Rs. __________ In word Rs. __________
(Please strike out whichever is not applicable)
1 I/We hereby declare that I/We have visited the site, fully exquisite myself/ourselves with the local situation regarding materials and
other factors pertaining to the work before submitting this tender.
2 I/we hereby declare that I/We carefully studied the conditions of specifications and other tender documents of this work and agree to
execute the same accordingly.
3 A tender with any overwriting in percentage (should both in word and figures) rejected out right.
4 Insertions and/or corrections in the percentage quoted ( both in word and figures) resulting into increase in the value of the work
shall be rejected outright unless it is authenticated by the office opening the tender at the time of opening of tender.
5 Dismentaling the existing material taken by contractor as mention rates.
Signature of Contractor Deputy executive Engineer
C.P Electrical R & B Sub Dn
Less for the D.M
M&R to EI in Various Types Of Residential Quarter at Sector-19 & 20, Gandhinagar (As Per Requirement
For Twelve Month)
Sr.no Item Qty. Per DM rate Total
1 Cost Of Old & u/s Light Pts. 50 Pts. 12.48
2 Cost Of Old & u/s Secondary Pts. 15 Pts. 2.12
3 Cost Of Old & u/s Bathroom Pts. 30 Pts. 6.24
4 Cost Of Old & u/s Fan Pts. 15 Pts. 18.28
5 Cost Of Old & u/s Looped Plug 15 Pts. 8.76
6 Cost Of Old & u/s Two Way Pts. 5 Pts. 16.60
7 Cost Of Old & u/s 6A Switch 60 Nos. 5.60
8 Cost Of Old & u/s 6A Plug 60 Nos. 5.60
9 Cost Of Old & u/s Regulator 30 Nos. 15.40
10 Cost Of Old & u/s Blank Plate 25 Nos. 1.00
11 Cost Of Old & u/s 16A Switch 30 Nos. 6.76
12 Cost Of Old & u/s 16A Plug 30 Nos. 7.52
13 Cost Of Old & u/s 6A Bell push 15 Nos. 5.60
14 Cost Of Old & u/s Two Way Switch 15 Nos. 6.36
15 Cost Of Old & u/s Modular SP MCb 5 Nos. 11.88
16 Cost Of Old & u/s Foot Light 5 Nos. 10.72
17 Cost Of Old & u/s Batten holder 20 Nos. 2.16
18 Cost Of Old & u/s 6A Switch 75 Nos. 0.84
19 Cost Of Old & u/s 16A Switch 50 Nos. 1.80
20 Cost Of Old & u/s 16A Socket 50 Nos. 3.04
21 Cost Of Old & u/s 6A Socket 40 Nos. 1.44
22 Cost Of Old & u/s 75x50 Trunking 10 mtrs 10.28
23 Cost Of Old & u/s 1.5 Mains 150 Mtr. 3.78
24 Cost Of Old & u/s 2.5 Mains 200 Mtr. 5.22
25 Cost Of Old & u/s 4 Mains 70 Mtr. 7.20
26 Cost Of Old & u/s 6 Mains 30 Mtr. 10.26
27 Cost Of Old & u/s 10 Mains 20 Mtr. 18.18
28 Cost Of Old & u/s 4x6 Mains 70 Mtr. 20.52
29 Cost Of Old & u/s 4x10 Mains 60 Mtr. 34.65
30 Cost Of Old & u/s 1.5x3Core Wire 100 Mtr. 3.96
31 Cost Of Old & u/s One Wire 6 Mains 15 Mtr. 4.77
32 Cost Of Old & u/s One Wire 10 Mains 15 Mtr. 7.92
33 Cost Of Old & u/s One Wire 25 Mains 10 Mtr. 20.70
34 Cost Of Old & u/s Computer Board 2 Nos. 42.72
35 Cost Of Old & u/s Ting Tong bell 10 Nos. 2.60
36 Cost Of Old & u/s T-5 Tube light 225 Nos. 18.00
37 Cost Of Old & u/s Downlight 16-20W 20 Nos. 22.00
38 Cost Of Old & u/s LED Strip Light 10 Nos. 7.36
39 Cost Of Old & u/s Spot Light 5 Nos. 52.80
40 Cost Of Old & u/s Mirror Light 5 Nos. 11.32
41 Cost Of Old & u/s 12W COB Light 5 Nos. 36.92
42 Cost Of Old & u/s MCB SP 15 Nos. 4.90
43 Cost Of Old & u/s 40A DP MCB 5 Nos. 18.50
44 Cost Of Old & u/s 63A FP MCB 5 Nos. 35.20
45 Cost Of Old & u/s Enclosure FP 5 Nos. 4.70
46 Cost Of Old & u/s Enclosure DP 10 Nos. 8.10
47 Cost Of Old & u/s 8 way DB Single phase 1 Nos. 64.00
48 Cost Of Old & u/s 40A DP ELCB 5 Nos. 128.00
Sr.no Item Qty. Per DM rate Total
49 Cost Of Old & u/s 63A FP ELCB 2 Nos. 147.50
50 Cost Of Old & u/s 900mm Ceiling fan 2 Nos. 172.08
51 Cost Of Old & u/s 1200mm Ceiling fan 15 Nos. 169.02
52 Cost Of Old & u/s 200mm Ex. Fan 8 Nos. 173.70
53 Cost Of Old & u/s industrial Ex. Fan 2 Nos. 180.00
54 Cost Of Old & u/s Bracket Fan 2 Nos. 221.22
55 Cost Of Old & u/s Pedestral Fan 2 Nos. 189.99
Dy.Executive Engineer Exe.Engineer
Sign of Contractor Cap.Proj. Elect.sub.Div-21 C.P.Electrical Division
Gandhinagar Gandhinagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
G S T LTR.pdf
GR.pdf
Revice Notice 2 of 2026-27.pdf
schedule a b and dm.pdf
STANDARD BIDDING DOCUMENT.pdf
PQ creteria with form 3a.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .