Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.7 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹53.7 L Quoted ₹57.9 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹62.0 L+₹4.1 L (7.12%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | ₹62.0 L+₹4.1 L (7.12%) | L2 | Rejected-AOC Rejected |
| 3 | Rejected-Technical 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | - | - | Rejected-Technical Two Class below |
| Sl No | Description | Qty | Unit | Ansh Enterprises L1 | M/s Kamal Traders L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed. | 550 | Cum | 110 ₹60,500 Lowest | 120 ₹66,000 |
| 2.00 | Excavation in trenches in any type of soil not exc. 1.5 mtr wide and exc. 1.5 mtr and not exc. 3.0 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed. | 0.2 | Cum | 375 ₹75 Lowest | 375 ₹75 Lowest |
| 3.00 | M&L for sand cushioning & covering of under ground cable using crushed metal sand in trenches for cable protection complete all as specified and directed. | 125 | Cum | 665 ₹83,125 Lowest | 680 ₹85,000 |
| 4.00 | M&L for sub class 'B' bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as specified and directed. | 15 | Per 1000 Nos | 6,250 ₹93,750 Lowest | 6,540 ₹98,100 |
| 5.00 | M&L for laying un-reinforced precast concrete cable cover, class HV type-1, flat size 300x180x40 mm for protection of under ground cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exc. 10mm over under ground cable in trenches complete all as specified and directed. | 2,900 | Each | 28 ₹81,200 Lowest | 28 ₹81,200 Lowest |
| 6.00 | Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as directed. | 325 | Cum | 48 ₹15,600 Lowest | 50 ₹16,250 |
| 7.00 | Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as directed. | 225 | Cum | 52 ₹11,700 Lowest | 55 ₹12,375 |
| 8.00 | Cutting existing road/ hardstanding of any type by using crow bar chisel upto a depth of 60 cm for laying HDPE/ GI pipe upto 100 mm including making good the surface by returning, filling, watering, ramming in layers of 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as directed. | 20 | Sqm | 325 ₹6,500 Lowest | 345 ₹6,900 |
| 9.00 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations and mass concrete for foundations of poles etc complete all as specified and directed. | 3.5 | Cum | 4,250 ₹14,875 Lowest | 4,550 ₹15,925 |
| 10.00 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary from work for finishing exposed faces of concrete smooth and even using extra cement complete all as specified and directed. | 0.2 | Cum | 6,750 ₹1,350 Lowest | 6,760 ₹1,352 |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
17 Jun 2026, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
REPAIR / MAINTENANCE AND IMPROVEMENT OF HT NETWORK INCL VCBs , UG CABLES , OH LINES, PANELS, TRANSFORMERS, AND OTHER CONNECTED ITEMS AT GARHI CANTT UNDER AGE E/M -II GE DEHRADUN
2026_MES_766676_1
1024/DDN/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE Dehradun
₹1.1 L
Yes
28 Aug 2026
20 May 2026
19 Jun 2026
20 May 2026
17 Jun 2026
11 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed. | 550 | Cum | - | - |
| 2 | Excavation in trenches in any type of soil not exc. 1.5 mtr wide and exc. 1.5 mtr and not exc. 3.0 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed. | 0.2 | Cum | - | - |
| 3 | M&L for sand cushioning & covering of under ground cable using crushed metal sand in trenches for cable protection complete all as specified and directed. | 125 | Cum | - | - |
| 4 | M&L for sub class 'B' bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as specified and directed. | 15 | Per 1000 Nos | - | - |
| 5 | M&L for laying un-reinforced precast concrete cable cover, class HV type-1, flat size 300x180x40 mm for protection of under ground cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exc. 10mm over under ground cable in trenches complete all as specified and directed. | 2,900 | Each | - | - |
| 6 | Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as directed. | 325 | Cum | - | - |
| 7 | Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as directed. | 225 | Cum | - | - |
| 8 | Cutting existing road/ hardstanding of any type by using crow bar chisel upto a depth of 60 cm for laying HDPE/ GI pipe upto 100 mm including making good the surface by returning, filling, watering, ramming in layers of 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as directed. | 20 | Sqm | - | - |
| 9 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations and mass concrete for foundations of poles etc complete all as specified and directed. | 3.5 | Cum | - | - |
| 10 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary from work for finishing exposed faces of concrete smooth and even using extra cement complete all as specified and directed. | 0.2 | Cum | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
1024Tender.pdf
Tender Documents • 1.39 MB
BOQ_858630.xls
BOQ • 3.16 MB
1024BOQCorrigendum.pdf
PDF • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .