Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Aug 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Ex Engineer ESSD Tangmarg
Electric Special Sub Division Tangmarg
Annual stage contract for Restoration Repairs rection of HT LT network and allied Sub Station works under the jurisdiction of Electric Special Sub Division Tangmarg under M and R for the FY 2024 25
2024_PDD_254686_1
E-NIT No.SSDT 07 of 2024-25,Dated 30/07/2024
Open Tender
Electrical Works
Item Rate
365 days
Annual Stage Contract for HT LT Network
Please refer Tender documents.
4 documents required · 4 mandatory
₹815
Major Head (0801-PDD) (AEE Tangmarg)
₹40,000
Yes
21 Aug 2024
30 Jul 2024
21 Aug 2024
30 Jul 2024
20 Aug 2024
1 Aug 2024
30 Jul 2024 - 1 Aug 2024
Amount
Loading, transportation and Erection of Steel Tubular Poles Of Sizes
ST Pole 11 mtr. Long (ST-410 SP56)
ST Pole 9 mtr. Long (ST-410 SP33)
ST Pole 8 mtr. Long (ST-410 SP15)
Loading, transportation and Erection of PCC Poles Of Sizes
PCC Pole 9 mtr. Long (WL =300 Kg)
PCC Pole 8 mtr. Long (WL =250 Kg)
Painting of ST Poles with 1 coat of Red Oxide and 2 coats of Aluminum Paint (including cost of paint)
ST Pole 11 mtr. Long (ST-410 SP56)
ST Pole 9 mtr. Long ( ST-410 SP33)
ST Pole 8 mtr. Long (ST-410 SP15)
Loading, transportation and Laying, Testing and Commissioning of ACSR Conductor of Sizes
0.03 ACSR Conductor (Weasel)
0.05 ACSR Conductor (Rabbit)
0.1 ACSR Conductor (Dog)
Loading, transportation and Laying, Fixing, Testing and Commissioning of Sub-Station Items
Installation, Testing and Commissioning of 11 KV Link Set (Post Type) of rated capacity 200 Amp (polymer type)
Installation, Testing and Commissioning of 11 KV Link Set (Post Type) of rated capacity 200 Amp (porcelain type)
Installation, Testing and Commissioning of 11 KV Link Set (Line Type) heavy duty having rated capacity 600 Amp (polymer type)
Installation, Testing and Commissioning of 11 KV Link Set (Line Type) heavy duty having rated capacity 600 Amp (porcelain type)
Installation, Testing and Commissioning of 11 KV Gang Operating, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type comprising of 9 No. insulators, pipes and lock pad etc complete job (Polymer Type)
Installation, Testing and Commissioning of 11 KV Gang Operating, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type comprising of 9 No. insulators, pipes and lock pad etc complete job (porcelain type)
Installation, Testing and Commissioning of Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arrestor with polymer housing, Stn. Type (Rashtriya, Spark or Yamuna Make)
Installation, Testing and Commissioning of Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arrestor with porcelain type housing, Stn. Type (Rashtriya, Spark or Yamuna Make)
Installation, Testing and Commissioning of 11 KV Horn Gap Fuse Set 3-Phase 200 Amp (Polymer Type)
Installation, Testing and Commissioning of 11 KV Horn Gap Fuse Set 3-Phase 200 Amp (porcelain type)
Fixing of G.I.Wire No. 8 SWG
Fixing of Guy wire 7/2.15mm Including Guy Insulators, Guy rods, turn buckles with Guy Assembly complete
Fixing of Bobbin Insulators 40 mm
Transportation and Fixing of Pole Collars of 50x8mm galvanized Flat Iron with Galvanized Nuts and Bolts of Sizes
Fixing of GI Barbed Wire for Ant climbing
Fixing of Ant climbing Devices
Fixing of 11 KV Danger Plate with Clamp
Fixing of Galvanized Nuts and Bolts of sorts
Transportation and Fixing of Galvanized Channel Iron Cross Arm (100x50x6mm), (75x40x6mm) duly fabricated including clamps and galvanized nuts and bolts of sizes with washers of sizes
Transportation and Fixing of Galvanized Angle Iron Brace (50x50x6mm) of Sizes duly fabricated including clamps of different sizes and galvanized nuts and bolts of sizes with washers of sizes
Transportation and Fixing of Galvanized V Cross-Arms duly fabricated of size 75x40x6mm Channel Iron Cross Arms including clamps of different sizes and galvanized nuts and bolts of sizes with washers of sizes
Laying of Earthing of Sub-Station -- (Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm) for connection of Transformer Body, G.O Set & Lightening Arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick massonary with RCC slab cover.
Laying of Chemical Earthing with Accessories Complete with 5' depth
Laying of Chemical Earthing with Accessories Complete with 8' depth
Installation, Testing and Commissioning of Protection Items (DP MCB C-Curve Series of breaking capacity 15 kA) (Schnieder/Siemens/Legrand Make)
Installation, Testing and Commissioning of Protection Items (TP MCB C-Curve Series of breaking capacity 15 kA) (Schnieder/Siemens/Legrand Make)
Installation, Testing and Commissioning of Protection Items (TP MCCB with Enclosure complete duly fitted over galvanized angle iron stand/frame duly grouted) (Schnieder/Siemens/Legrand/L&T - D Sine Series Make)
32 Amp (breaking capacity 25 kA)
40 Amp (breaking capacity 25 kA)
63 Amp (breaking capacity 25 kA)
100 Amp (breaking capacity 25 kA)
160 Amp (breaking capacity 36 kA)
300 Amp (having breaking capacity of 36 kA) with distribution box having fixed with voltmeter, ammeter, bus-bars and wiring complete to be fixed on ground over angle/channel iron cross arms of suitable length
400 Amp (having breaking capacity of 36 kA) with distribution box having fixed with voltmeter, ammeter, bus-bars and wiring complete to be fixed on ground over angle/channel iron cross arms of suitable length
630 Amp (having breaking capacity of 36 kA)
Installation, Testing and Commissioning of Protection Items (TPN MCCB with Enclosure complete duly fitted over galvanized angle iron stand/frame duly grouted) (Schnieder/Siemens/Legrand/L&T - D Sine Series Make)
40 Amp (having breaking capacity of 25 kA)
63 Amp (having breaking capacity of 25 kA)
100 Amp (having breaking capacity 25 kA)
160 Amp (having breaking capacity 36 kA)
300 Amp (having breaking capacity of 36 kA) with distribution box having fixed with voltmeter, ammeter, bus-bars and wiring complete to be fixed on ground over angle/channel iron cross arms of suitable length
400 Amp (having breaking capacity of 36 kA) with distribution box having fixed with voltmeter, ammeter, bus-bars and wiring complete to be fixed on ground over angle/channel iron cross arms of suitable length
630 Amp (having breaking capacity of 36 kA) along with Enclosure and angle iron stand duly grouted
Fixing of Aluminum Thimbles Suitable for Cables of Sizes (3D/Dowells Make)
Fixing of Copper Thimbles Of Sizes (3D/Dowells Make)
Fixing of Aluminum Solder less Clamps Suitable for DT's of Ratings
Fixing of Self Adhesive PVC Electrical Insulation Tape 1.80 cmx7mx0.125mm (ISI Mark Anchor/Steel Grip/GM or Equivalent make)
Loading, transportation and Installation, Testing and Commissioning of 11KV Line Material including HT Cabling
Fixing of 11 KV Polymeric composite Pin Insulator 12 kV, 5 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm (Spark/Rashtriya)
Fixing of 11 KV Pin Insulator (Porcelain type)
Fixing of 11 KV GI Pins (900 gm)
Fixing of 11 kV Polymeric composite Disc Insulator 12 kV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm, conforming to ISO 9001, 2008 standards, working temperature -10 to 40 deg Cel having 16 mm dia fiber rod (Yamuna/Spark/Rashtriya make)
Fixing of 11 KV Tension Disc Fittings for 0.05 ACSR Conductor
Fixing of 11 KV Tension Disc Fittings for 0.1 ACSR Conductor
Fixing of Guy Rods with Turn Buckle
Fixing of F-Top fabricated of Galvanized Channel Iron Cross Arm (75x40x6mm) 1.5' long and of 6'' horizontal length
Fixing of Suspension Cable Hooks (Ento/Rechim Make)
Fixing of Tension Cable Clamp (Ento/Rechim Make)
Installation, Testing and Commissioning of 11 KV Isolator, double break, 3-pole, 600 Amp, horizontal mounting Type, with Earth Switch.
Fixing of PG (Parallel Groove) Clamps for ACSR Conductor
Fixing of LT Part including LT Cabling
Fixing of LT Shackle Insulators 16 KN 100 mm W.S/J.S.I Make.
Fixing of GI U/D-Clamps for LT Shackle Insulators with 01 No. MS Bolt
Fixing of GI Mukhi Clamp (Scaff holding clamp) of 50x8 mm galvanized flat iron (0.75 Kg per No.) with end inner dia 18 mm for Shackle Insulators suitable for ST Pole
Installation, Testing and Commissioning of LT fuse set comprising of requisite al. bus bar mounted on LT polymer insulator assembled on galvanized angle iron frame including necessary clamps
Fixing of LT Line Spacer - 2 Phase 3 Wire
Fixing of LT Line Spacer - 3 Phase 4 Wire
Loading, transportation and Laying, Testing and Commissioning of 1-Core, 1.1 KV Grade, XLPE Insulated Stranded (Un-Armored Cable) Aluminum Conductor FRLS (Flame Retardant Low Smoke) Type (Havells/Polycab/Grindlays/Gloster Make)
Loading, transportation and Laying, Testing and Commissioning of 1-Core, 1.1 KV Grade PVC Insulated Armored Aluminum Cable (Havells/Polycab/Grindlays/Gloster Make)
Loading, transportation and Laying, Testing and Commissioning of 2-Core, 1.1 KV Grade XLPE Insulated Aluminum Conductor Armoured FRLS Type (Havells/Polycab/Grindlays/Gloster Make)
Loading, transportation and Laying, Testing and Commissioning of 3½-Core, 1.1 KV Grade XLPE Insulated Stranded (Un-Armored Cable) Aluminum Conductor, FRLS (Flame Retardant Low Smoke) Type … (Havells/Polycab/Grindlays/Gloster Make)
Loading, transportation and Laying, Testing and Commissioning of 3½-Core, 1.1 KV Grade XLPE Insulated Armored Cable (Havells/Polycab/Grindlays/Gloster Make)
Loading, transportation and Laying, Testing and Commissioning of 2 Core (Aluminum) XLPE Un-Armored Aluminum Cable … (Havells/Polycab/Grindlays/Gloster Make)
10 mm sq 2-Core Cable
16 mm sq 2-Core Cable
25 mm sq 2-Core Cable
35 mm sq 2-Core Cable
50 mm sq 2-Core Cable
Loading, transportation and Laying, Testing and Commissioning of 10 mm sq 2-Core Copper Wire XLPE Insulated (Unarmored)
Loading, transportation and Laying, Testing and Commissioning of 4-Core (Aluminum) XLPE Cable (Havells/Polycab/Grindlays/Gloster Make)
16 mm sq 4-Core Cable
25 mm sq 4-Core Cable
Loading, transportation and Laying, Testing and Commissioning of Multi Strand Copper Wire (Havells/Polycab/Imperial or Equivalent Make)
3-Ø, 4-Wire Prodigy Meter (Secure or Equivalent Make)
Laying of Earthing Rods as per IS specification
Laying of Earthing of ST Poles 8 mtr long using GI Wire 8 No. having 115 turns (as per REC standards)
Laying of Earthing of ST Poles 9 mtr long using GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip.
Cement bottoming of S.T poles in 1:2:4 mix 1/6th of the height of pole below the ground and 1ft above the ground cylindrical shape with circular radius 9” from the pole centre) using 40mm crushed stone aggregate mix. As per Drawing Pit =( 600x600x1600)& Tapered at the Top. (as per REC standard)
ST Pole 11 mtr. Long (ST-410 SP56)
ST Pole 9 mtr. Long ( ST-410 SP33)
ST Pole 8 mtr. Long (ST-410 SP15)
Loading, transportation and Laying, Testing and Commissioning of 1-Core, 11 KV Grade (XLPE Insulated Armored Aluminum Cable) (Havells/Polycab/Grindlays/Gloster Make)
Loading, transportation and Laying, Testing and Commissioning of 3-Core, 11 KV Grade (XLPE Insulated Armored Aluminum Cable) (Havells/Polycab/Grindlays/Gloster Make)
Loading, transportation and Laying, Testing and Commissioning of 3-Core, 11 KV Grade (ABC Type Cable) (Havells/Polycab/Grindlays/Gloster Make)
Loading, transportation and Installation, Testing and Commissioning of 11 KV Heat Shrinkable (3-Core) Cable Termination Kit - (XLPE TYPE) - (OUTDOOR TYPE) (3M/Rechim make)
50 mm sq 3-Core
70 mm sq 3-Core
95 mm sq 3-Core
120 mm sq 3-Core
185 mm sq 3-Core
240 mm sq 3-Core
300 mm sq 3-Core
400 mm sq 3-Core
Loading, transportation and Installation, Testing and Commissioning of 11 KV Heat Shrinkable (1-Core) Cable Termination Kit - (XLPE TYPE) - (OUTDOOR TYPE) (3M/Rechim make)
50 mm sq 1-Core
70 mm sq 1-Core
95 mm sq 1-Core
120 mm sq 1-Core
185 mm sq 1-Core
240 mm sq 1-Core
300 mm sq 1-Core
400 mm sq 1-Core
Loading, transportation and Installation, Testing and Commissioning of 11 KV Heat Shrinkable (3-Core) Cable Termination Kit - (ABC TYPE) - (OUTDOOR TYPE) (3M/Rechim make)
35 mm sq 3-Core
50 mm sq 3-Core
70 mm sq 3-Core
95 mm sq 3-Core
120 mm sq 3-Core
185 mm sq 3-Core
240 mm sq 3-Core
300 mm sq 3-Core
400 mm sq 3-Core
Loading, transportation and Installation, Testing and Commissioning of 11 KV 1-Core AB Cable Jointing Kit
Loading, transportation and Installation, Testing and Commissioning of 11 KV 3-Core XLPE Cable Jointing Kit
Loading, transportation and Installation, Testing and Commissioning of 11 KV 1-Core XLPE Cable Jointing Kit
Loading, transportation and Installation, Testing and Commissioning of HT Tri-Vector Metering unit Complete with CT/PT units and with all accessories. PT 11 KV/ 110 V, Class of Accuracy 0.5 S, VA 15 and CTR up to 50/5, Class of Accuracy 0.5 S, VA 15, STC 70.3 kVA for 3 Sec (CT/PT Unit .. AE/Everest/Amp-Volt make, Meter .. Secure/L&T make)
Dismantling of Items etc
Dismantling of 11 KV Link Set (Post Type)
Dismantling of 11 KV Gang Operating, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type comprising of 9 No. insulators, pipes and lock pad etc complete job
Dismantling of Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arrestor with polymer housing, Stn. Type (Rashtriya, Spark or Yamuna Make)
Dismantling of 11 KV Horn Gap Fuse Set 3-Phase 200 Amp
Dismantling of 11 KV Porcelain Pin Insulator with Pins
Dismantling of 11 KV Tension Disc Fittings for 0.05/0.1 ACSR Conductor
Dismantling of Channel Iron Cross Arm of Sizes, Galvanized Angle Iron Brace of Sizes with clamps, nuts and bolts
Dismantling of LT fuse set comprising of requisite al. bus bar mounted on LT polymer insulator assembled on angle iron frame including necessary clamps
Dismantling of HT/LT Poles
ST Pole 11 mtr. Long (ST-410 SP56)
ST Pole 9 mtr. Long ( ST-410 SP33)
ST Pole 8 mtr. Long (ST-410 SP15)
8 /9 mtr. long PCC Poles
Wooden Poles
Dismantling/Re-Erection of HT/LT Poles
ST Pole 11 mtr. Long (ST-410 SP56)
ST Pole 9 mtr. Long ( ST-410 SP33)
ST Pole 8 mtr. Long (ST-410 SP15)
Straightening of Tilted HT/LT Poles
ST Pole 11 mtr. Long (ST-410 SP56)
ST Pole 9 mtr. Long ( ST-410 SP33)
ST Pole 8 mtr. Long (ST-410 SP15)
8 /9 Mtr long PCC poles
Dismantling of ACSR Conductor
Dismantling/Relaying of Conductor
Stringing of Loose/Sagged ACSR Conductor
Branch Cutting of Extensive Trees
Loading, transportation and Installation,Testing and Commissioning of 11/0.433 KV, 3 Phase Distribution Transformer
Dismantling/Unloading of 11/0.433 KV, 3 Phase Distribution Transformer
Shifting of 11/0.433 KV, 3 Phase Distribution Transformer from Existing Stn to other suitable location or newly created Sub-Stn "Including Charges of Pvt. Hired Crane"
Installation, Testing and Commissioning of LED Streetlights (Havells/Bajaj/Philips/Syska or Equivalent) The streetlight should be single piece die cast aluminum, corrosion resistant with ingress protection of IP66 and covered with toughened glass/polycarbonate covering. The light shall have a power factor of > 0.95
Installation, Testing and Commissioning of SVL 250 Watt (Bajaj/Phillips or Equivalent Make)
Installation, Testing and Commissioning of Choke for 250 W SVL (Bajaj/Phillips or Equivalent Make)
Installation, Testing and Commissioning of Igniter for 250 W SVL (Bajaj/Phillips or Equivalent Make)
Installation, Testing and Commissioning of Condenser for 250 W SVL (Bajaj/Phillips or Equivalent Make)
Installation, Testing and Commissioning of 6 Amp ON/OFF Switch (Box type)
Laying of HDPE Pipe 50 mm dia including trench excavation in hard soil (1'x2'), refilling back the same and removal of surplus excavated material to appropriate place
Fixing of Galvanized Iron Bend duly fabricated having size 2' by 1.5' and 35 mm dia (duly painted)
Fixing of PVC Conduit Pipe 2 mm sq x 1'' and 10' long along with ties for tightening purpose (Polycab/Anchor or Equivalent)
Installation, Testing and Commissioning of Photoelectric Switch Outdoor Type for Street lighting (Standard Quality)
Installation, Testing and Commissioning of Digital Servo Control Card (Single/Double)
Installation, Testing and Commissioning of 80 Amp 3 Phase Pole Contactor (L&T/Legrand/Havells or Equivalent Make)
Installation, Testing and Commissioning of Contactor Coil
Installation, Testing and Commissioning of Control Wiring
Fixing of Bakelite Sheet 30''x6''
Installation, Testing and Commissioning of Astronomical Time Control Switch (Astro Mini) 110-240 VAC 1 Phase-2W, 1 C/O Base/DIN
Internal wiring
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of LED Lamp 9 Watt.
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. LED lights 12watts (standard make)
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. LED lights 18watts (standard make)
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. LED lights 22watts (standard make )
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. Pendant Holder Standard make ISI mark
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of SS Combine 6-10 Amp with box.
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of Switch 6-10 Amp with Gang Box (1 to 8 Module)
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of 6 Amp 5 Pin Socket with box
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of 6 Amp switch
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of insulating tape rolls
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of 1 sqmm multistranded coper wire (1 coil =90 mtr)
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of 1.5 sqmm multistranded coper wire (1 coil =90 mtr)
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of 2 sqmm multistranded coper wire (1 coil =90 mtr)
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of 2.5 sqmm multistranded coper wire (1 coil =90 mtr)
Carriage from divisional stores upto site, loading, unloading, fixing, testing etc. of 4 sqmm multistranded coper wire (1 coil =90 mtr)
GULMARG ELECTRICALS AND SUPPLIERS
ABDULLAH AND CO
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .