Supply Installation Testing Commissioning Of Various Size Of Battery Operated Electromagnetic Flow Meter With All Kind Of Accessories And Allied Equipments With Three-Year Free Comprehensive Maintenance Guarantee For Water Supply Scheme At Notified Area GIDC-Sachin Industrial Estate 2026-27.
326278
04 of 2026-27(Serial No. 1)
Open
Water Equipments/ Meter/ Drilling/ Boring
Works
Surat
16 documents required · 16 mandatory
₹4,248
Chief Officer, Sachin Notified Area
₹2.4 L
25 Aug 2026
3 Aug 2026
31 Aug 2026
3 Aug 2026
25 Aug 2026
3 Aug 2026
Name Of Work :-Supply, Installation, Testing, Commissioning Of Various Size Of Battery Operated
Electromagnetic Flow Meter With All Kind Of Accessories And Allied Equipment’s
With Three-Year Free Comprehensive Maintenance Guarantee For Water Supply
Scheme At Notified Aren GIDC Industrial Estate 2026-27.
ITEM DESCRIPTION OF ITEM QTY. UNIT NET RATE Total
NO. in Rs. Amount Rs.
PART - I (For Special Various Size of Battery Operated
Electromagnetic flow meter)
1 Supply, Installation, Testing, Commissioning of Full Bore
Electromagnetic flow meter with factory calibration, Inbuilt Battery
Power Operated, flanged connection, Flow sensor, Indicator, transmitter
and totaliser with all accessories viz. surge arrestor, associated cables,
cabinets, hardware’s, etc complete as per following specifications: 1)
Flow Meter/ Sensor: DC pulsed type, Full bore, remote, IP 68 Protection,
Flanged process connection as per IS 1538/ASME B16.5 Class 150 RF
or equivalent standard, SS316/SS304/ Metallic Alloy-C Flow Tube,
SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/
Inbuilt Grounding Electrode, Liner- EPDM/ PP/ elastomer/
Neoprene/Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast
Aluminium/ Carbon steel with Anticorrosive Paint Coil Housing with
Junction Box, CS/SS flanges (ISO 12944-2 certified), Suitable Pipeline
Material DI/CI/MS/HDPE, Straight pipe requirement 3D upstream / 2D
downstream. 2) Flow Transmitter/ Converter ( Remote Field Mounted):
Microprocessor based, Modular design, Display-2 line LCD for
indication of actual flow rate, forward, reverse, sum totaliser display
battery, alarms, empty pipe, ±0.4/% accuracy at 0.3 to 4 m/sec velocity,
one scalable pulse/ one status, one Modbus output, one GSM/ GPRS
output, Antenna- Required (3 m cable), Compatible with SCADA,
RS485 with Modbus, IP68 (sensor & cable glands factory sealed)/ IP
protection, Die cast aluminium/polycarbonate/ SS316 with
Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt
EEPROM and Data Logger (selectable: daily/weekly/monthly),
meters cable length for sensor to transmitter communication, Minimum
5 years battery lifetime, Battery Capacity 2D Cell 3.6 V / 33 Ah , Non
Rechargeable Lithium-thionyl chloride/ Ni-Cd/Alkaline high power
batteries or better, Hourly Basis Worldwide transmission of measured
data and events via e‐mail and SMS by integrated GPS/GPRS modem,
Reliable data storage facility through integrated SD card etc, Battery
Replacement Without data loss, along with wall mounted/ stand mounted
cabinet. Full Bore Electromagnetic Flow Meter include Calibration
Certificate-ISO 17025 mandatory per meter, Liner Certification WRAS,
Coating- ISO 12944-2 (Inbuilt Battery Power Operated)- PN
A SITC 40 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt
Battery Power Operated)- PN
B SITC 50 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt Battery
Power Operated)- PN
C SITC 65 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt Battery
Power Operated)- PN
D SITC 80 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt Battery
Power Operated)- PN
E SITC 100 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt
Battery Power Operated)- PN
F SITC 150 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt
Battery Power Operated)- PN
G SITC 200 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt
Battery Power Operated)- PN
H SITC 250 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt
Battery Power Operated)- PN
I SITC 300 mm dia. Full Bore Electromagnetic Flow Meter (Inbuilt
Battery Power Operated)- PN
2 Engineering, procurement, Installation, Testing and commissioning of
suitable size piping works includes rising main, pipe manifold system
including fabrication welding of specials, eccentric reducers, concentric
reducers, bends, flanges, thrust blocks , chambers, required civil works,
spectacles blinds, gaskets, nut bolts, washers, etc. complete with erection
hardware, necessary mounting support etc. complete. Scope also
includes connections to rising main with MS/GI pipes complete in all
respect with required accessories, erection hardware, etc. with outer side
3LPE coating & inside solvent free liquid epoxy lining on pedestal or
chairs upon prepare formation or prepaid bedding in trenches the rates
include conveyance loading, unloading, jointing and hydro testing etc.
complete. make as per annexure. MS/GI pipe of suitable size and thick
with specials including excavation etc. complete. Job also include
removal of existing pipe and re installation new one as per the site
condition. Consider for installation of flow meter or As Instructed by
Engineer In Charge.
A SITC 40 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 72.00 RMT 321.00
B SITC 50 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 51.00 RMT 435.00
C SITC 65 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 24.00 RMT 562.00
D SITC 80 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 219.00 RMT 689.00
E SITC 100 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 12.00 RMT 992.00
F SITC 150 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 12.00 RMT 1470.00
G SITC 200 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 12.00 RMT 1960.00
H SITC 250 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 12.00 RMT 3266.67
I SITC 300 mm dia. Electromagnetic flow meter at user end- MS/GI pipe 12.00 RMT 6533.34
Sluice Valve:- Providing and supplying ISI mark CI D/F Sluice Valves
as per IS:14896 (Latest Edition) of following class and diameter
including all taxes, insurance, transportation, freight charges, octroi,
inspection charges, loading. unloading conveyance to departmental
stores, stacking etc. complete (PN-1 With Gear operated (Alt-1 type long
A SITC 40 mm dia. 24.00 No. 1692.8
B SITC 50 mm dia. 17.00 No. 2116
C SITC 65 mm dia. 8.00 No. 2554
D SITC 80 mm dia. 73.00 No. 2857
E SITC 100 mm dia. 4.00 No. 3875
F SITC 150 mm dia. 4.00 No. 6452
G SITC 200 mm dia. 4.00 No. 10902
H SITC 250 mm dia. 4.00 No. 17518
I SITC 300 mm dia. 4.00 No. 22795
4 SITC M.S./C.I Specials Flanged Ends Up to 300 mm dia. 830.00 KG 98
5 Providing and laying controlled cement concrete M200 for Cast-in-situ. 120.00 Cu. M 7867.71
water meter chamber of dimension of 1000x1000 item including PCC of
Gread M-15, curing, cost of form work, cost of reinforcement for
reinforced concrete work.
6 Demolition including stacking of serviceable materials and disposal of 80.00 Cu. M 1110.75
unserviceable materials with all lead and lift. (i) R.C.C. work
7 Excavation for foundation upto 1.5 m depth including sorting out and 100.00 Cu. M 122.941
stacking of useful materials and disposing off the excavated stuff up to
50 Meter lead.(A) Loose or soft soil
TOTAL PART - I Rs.
PART - II (FOR SITC of Software System)
8 Supply installation testing commissioning Shielded Shielded Control / 1420.00 Rmt. 203.01
Instrumentation Cables with necessary ISI mark Medium class rigid
PVC pipes with necessary accessories with termination in machine and
control equipments/ Flow transmitter, Level transmitters to Modem.
Sq mm Shielded Armoured
9 SITC of IoT based Gateway device for interfacing of flow meter installed 142.00 No. 38500.00
at various industries, as well as GPRS based wireless communication
with cloud based SCADA for overall monitoring having following
features at the minimum:
1.Battery operated.
2.Built in SD Card based data storage for 5 years.
3.Built in RTC with GSM sync facility.
4.Remote GPRS Connectivity.
5.Local Wi-Fi Connectivity.
6.IoT based Communication with server.
10 Smart control (RTU) panel: – Supply, Installation, Testing & 1.00 No. 285000.00
Commissioning of Intelligent unit based control Panel with remote data
transmission facility GPRS 3G/4G based - communication card RS-485.
Min. 2 KVA UPS (with 60-minute backup) along with suitable rating
SMF batteries, cabling between UPS and battery and all other
accessories as per standard), etc. complete in all respects The unit shall
have provision for: 1 - 08 Analog inputs for accepting 4-20 ma dc
signals from flow meters / level / pressure transmitters. 2) - 12 Digital
inputs for Pump / Valve status monitoring. 3) 08 Digital outputs for
pump/ valve operation. 4) Provision for schedule / Level based ON/OFF
command generation for pumps/ Valves
11 Meter Reading Software for Standard / AMR Compatible/ Mechanical 1.00 No. 500000.00
MultiJet AMR Meter / Ultrasonic AMR Meter/ Full Bore
Electromagnetic flow meter: Design, Supply, Installation, Testing,
Commissioning of Web Based/ Cloud Based AMR Software for Mobile
Based and Web Based Application, software shall have various analysis
tools which provides Alarm, Trends, Events, Data Logging and Report
Facility. Software shall collect meter data, store in to cloud and export to
billing system with a pre-defined file format. 3 Years hosting & Software
charges including GPRS SIM card charges. GPS/GIS with Google Maps
Mapping. Map based dashboard with color indications. Plot wise water
consumption report generation based on tariff. Mobile app for
notifications and monitoring. SCADA Software shall be capable of
monitoring at least minimum 400 flowmeters or field devices.
Considering the experience, knowledge of the meter data and expertise
in meter data analysis the cloud based solution shall be provided by
reputed water meter manufacturer 1)Meter Reading Software
12 Providing and Supplying of Submersible dewatering pump electrically 2.00 No. 132400.00
operated with portable compact power supply unit (Rechargeable battery
TOTAL PART - II Rs.
TOTAL PART - A - (I+II) Rs.
I / We agree to carry out the above work at ____________ % above the estimated rate ((In Words)
_________________________________________________) percentage above the Estimated Tender Rate.
I / We agree to carry out the above work at ____________ % below the estimated rate ((In Words)
_________________________________________________) percentage below the Estimated Tender Rate.
Estimated Amount Estimated Amount
Put to Tender Rs. 2,38,85,429.02 Put to Tender Rs.
Add % Above Rs. _____________ Deduct % Below Rs. ______________
Net Amount Rs.____________ Net Amount Rs. ______________
Net in Figure Rs. _____________ Net in Figure Rs. ______________
I / We have read the Condition mentioned in this tender and agree to abide by the same.
Note:- Estimated Cost put to tender is excluding GST and Including all other Taxes. GST will be paid additional
as per applicable rate prevailing from time to time and all other statutory liabilities are part of estimated
cost and will be bound by bidder. Prospective bidder may please by read carefully, app prevailing policy
/Government Resolution (GT) of Govt. of Gujarat (GoG)/competent authority, regarding GST and
submit the price bid offer accordingly.
Signature of Contractor with Seal Sachin Notified Area,
G.I.D.C.-SACHIN
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
DTP flow meter .pdf
SCHEDULE B.pdf
B1 Agreement.pdf
Cori-326278.pdf
Corrigendom-02.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].