| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | ₹36.0 L Quoted ₹36.9 L | L1 | Accepted-AOC Awarded contract being lowest |
| 2 | L2₹42.9 L+₹6.0 L (16.3%)Rejected-AOC | ₹42.9 L+₹6.0 L (16.3%) | L2 | Rejected-AOC Not being lowest |
| 3 | L3₹44.0 L+₹7.1 L (19.3%)Rejected-AOC | ₹44.0 L+₹7.1 L (19.3%) | L3 | Rejected-AOC Not being lowest |
| Sl No | Description | Qty | Unit | JM Engineering L3 | TAMS ASSOCIATES L2 | Green Ray Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and fix in repairs LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-55 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, all MCCBs must be have thermal magnetic relrase, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including the following Switchgears, fixtures and fitments mentioned below. | 1 | Each Job | 3,00,000 ₹3,00,000 | 1,80,000 ₹1,80,000 Lowest | 2,18,000 ₹2,18,000 |
| 1.10Busbars:- TPN- Not less than 400 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set. Incoming:- (i) MCCB 250 A, 4 Pole, 36KA with thermomagnetic release- 01 No., (ii) CT's 200/5 -03 No., (iii)Multifuction meter -01 No. (iv) Phase Indicating lamps -03 (v) Control fuses / MCB -03 Nos | ||||||
| 1.20Outgoing:- Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles.(Contd....) | ||||||
| 1.30(Contd....) (i) MCCB, 4 pole 100 A, 36 KA - 04 No (iii) MCCB, 4 pole 125 A, 25 KA - 02 No (v) MCB, TPN 40 A - 02 Nos (v Timer - 01 No (iv) MCB TPN 16 KA , 32 Amp 1 set duly connected with contactor 40 Amp (vi) Manual.auto control switch, duly wind up to terminal block for connecting street light circuits Note:- (i) A clear space of 200 mm shall be kept from floor level for switchgear compartment. (ii) Air ventilation breathers with exhaust fan plastic body 100mm sweep to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. (iii) Each compartment shall be numbered / lettered as approved by GE. (iv) LT panel shall be fixed in existing location and the disturbed surrounding surfaces shall be made good as per exising specifications. The cost of making good shall be deemed included in unit quoted rate. (v) Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the bulk order | ||||||
| 2.00 | All as per serial item No. 1 here in before but LT Panel Outdoor type with the following switchgears, fittings & fixures :- | 1 | Each | 2,20,000 ₹2,20,000 | 1,70,000 ₹1,70,000 | 1,60,000 ₹1,60,000 Lowest |
| 2.10Busbars TPN-400 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set. Incoming (i) MCCB 250 A, 4 Pole, 36KA with thermomagnetic release (with release range 160A-250A) -01 (ii) CT's 250/5 -03 No. with 01 selector switch -01 No. (iii) Multifuction meter -01 No -01 No. (iv) Phase Indicating lamps -03 No. (v) Control fuses/MCB 32 Amp SP -03 No. Outgoing:- (i) MCCB, 4 pole 100 A, 16 KA - 04 Nos (ii) MCCB, 4 pole 63 A, 16 KA - 03 Nos (iii) MCB SPN 20 A - 02 Nos | ||||||
| 3.00 | All as per serial item No. 1 here in before but LT Panel Outdoor type with the following Switchgers, fittings & fixures :- | 1 | Each Job | 3,40,000 ₹3,40,000 | 2,60,000 ₹2,60,000 Lowest | 2,60,325 ₹2,60,325 |
| 3.10Busbars:- TPN-Not less than 792 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set Incoming:- (i) MCCB 400 A, 4 Pole, 36 KA with thermomagnetic release - 02 No (ii) CT's 400/5 -03 No., (iii) Multifuction meter -01 No-01 No. (iv) Phase Indicating lamps -03 (v) Control fuses / MCB -03 No. (Contd....) | ||||||
| 3.20(Contd....) Outgoing:- (i) MCCB, 4 pole 250 A, 36 KA -03 No (ii) MCCB, 4 pole 100 A, 16 KA -01 No (iii) MCB TPN 16 KA , 63 Amp 1 set duly connected with contactor 32 Amp . (iv Timer and protection MCB etc , (v) MCB TPN 16 KA , 32 Amp 1 set duly connected with contactor 40 Amp (vi) Manual.auto control switch, duly wind up to terminal block for connecting street light circuits | ||||||
| 4.00 | Attending LT 1100 volt electrical cable/LT panel complaints which including interruption/failure of power supply/voltage variation/replacing fuses as required/tripping of circuit breaker including MCBs/MCCBs/ACBs, etc. Removing burned cable end and refixing after replacing aluminium lugs including using necessary colour coded PVC self adhensive protective tape. NOTE :-- (i) Earth work/LT Cable and connected work/MCCB/ MCBs and other major items if used shall be measured and paid separately, all other materials like cable lugs, insulation tape etc used shall deemed to be included in the quoted rate. (ii) If contractor shall failed to attend the complaint within 2 hrs, a penality of Rs.1000.00 per hr will imposed on him upto 12 hrs then after a penality of Rs.1500.00 per hr will be imposed. In this matter GE's decision is final.(Contd....) | 150 | Each Job | 300 ₹45,000 Lowest | 1,500 ₹2,25,000 | 2,600 ₹3,90,000 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 May 2026, 6:55 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
REPAIR REPLACEMENT OF SWITCH GEAR INDOOR AND OUTDOOR LT PANEL SUB PANEL AND CONNECTED EM WORKS IN SUB STATION AND ELECTRIC INSTALLATION AT NASA CERA AND ORA AREA AT INA EZHIMALA
2026_MES_764372_1
GE MAINT EZHIMALA 8851
Open Tender
Civil Works
Item Rate
330 days
Ezhimala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹70,000
Yes
2 Jul 2026
9 May 2026
5 Jun 2026
9 May 2026
30 May 2026
23 May 2026
9 May 2026 - 15 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fix in repairs LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-55 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, all MCCBs must be have thermal magnetic relrase, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including the following Switchgears, fixtures and fitments mentioned below. | 1 | Each Job | - | - |
| 0.0 | Busbars:-
TPN- Not less than 400 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set. Incoming:- (i) MCCB 250 A, 4 Pole, 36KA with thermomagnetic release- 01 No., (ii) CT's 200/5 -03 No., (iii)Multifuction meter -01 No. (iv) Phase Indicating lamps -03 (v) Control fuses / MCB -03 Nos | - | - | - | - |
| 0.9 | Outgoing:-
Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles.(Contd....) | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.95 MB
Tender.pdf
Tender Documents • 0.80 MB
BOQ_856134.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .