Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC H 45 MAHESH NAGAR AMBALA CANTT 133001 HARYANA | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹40.7 L+₹1.7 L (4.24%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹44.5 L+₹5.4 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹44.9 L+₹5.9 L (15.0%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹45.4 L+₹6.3 L (16.2%)Rejected-Finance 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
13 Jan 2021, 6:00 pmClosed
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-62(P)/2020-21 PROVN OF CERTAIN LBW, SPECIAL REPAIR AND MINOR WORKS (SANCTIONED WORKS) IN SECTOR A UNDER AGE B/R-II OF GE (NORTH) AMBALA CANTT
2020_MES_398917_1
GE(N)Amb-62(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹96,000
Yes
29 Jan 2021
16 Dec 2020
15 Jan 2021
16 Dec 2020
13 Jan 2021
30 Dec 2020
16 Dec 2020 - 30 Dec 2020
Amount
Schedule 'A' part-I ie B/R items
Excavating in post holes (or similar holes) in hard /dense soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material exc 250m but n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:5:10 Type E2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks in half brick thick wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
M&L rendering 15 mm thick on fair faces of brick work or concrete wall surfaces in cement mortar 1:4 using water proofing compound and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. ( water proofing compound shall be measured and paid for separately) .
M&L preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
Surface dressing not exceeding 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge exc 63mm and n exc 100mm , deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge n exc 63mm , deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L 200 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 150 mm thick PCC 1:2:4 Type B2 using 40mm graded crushed stone aggregate as in floor/ hard standing etc,laid in alternate bays including forming contraction/dummy joints and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 Type B2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC 1:2:4 type B1 using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:3:6 Type C2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 Type B2 using 40mm graded crushed stone aggregate as in surface channel and drain complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 40 mm thick PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in floor, laid in alternate bays and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
S&F glass dividing strips, 38mm wide and 3mm thick, inserted in position to confirm to design complete all as specified and as directed by the Engineer-in-Charge
Extra for forming fair finish drain or channel 45 cm inner girth in cement concrete using extra cement including forms mould mitered/ stopped end etc complete all as specified and as directed by the Engineer-in-Charge.
M&L form work to soffits of suspended slabs such as roof slabs, , floor slabs, landings and similar work n exc 200mm thick, finished rough surfaces of concrete flat complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M&L 15 mm thick cement plaster on brick or concrete walls surface in CM 1:6, finished even and smooth with out using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete wall and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 5 mm thick on fair faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster 15 mm thick in cement motar 1 :3 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on roof slab surface in cement mortar 1:4, mixed with water proofing compound and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge. ( water proofing compound shall be measured and paid for separately)
M&L rendering 10 mm thick on fair faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in skirting/ dado, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including rendring 10 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/skirtings/dados of size 350x250x7mm/450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and as directed by the Engineer-in-Charge.
M & L brushing neat cement slurry with 3.0 kg cement per sqm, complete all as specified and as directed by the Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
Taking down wooden shutter from the frame exc 1.00 sqm but not exc 2.00 sqm each and refixing in the same opening including adjusting as per opening complete all as specified and as directed by the Engineer-in-charge.
Taking down steel shutter from the frame exc 1.00 sqm but not exc 2.00 sqm each and refixing in the same opening including welding and adjusting as per opening complete all as specified and as directed by the Engineer-in-charge.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge
S & F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as specified and as directed by the Engineer-in-Charge.
Dismantaling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed by the Engineer-in-Charge.
Dismantling structural steel work including doors , gates but excluding framed truss etc. complete all as specified and as directed by the Engineer-in-Charge.
S & F 0.71mm thick, plain, aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and as directed by the Engineer-in-Charge
S & F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type hook bolts with washer in roofs, walls etc in any radius with grade of zink coating 275 complete all as specified and as directed by the Engineer-in-Charge
M & L mild steel work in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed by the Engineer-in-Charge
M&L preparation of new steel surface and applying two coats of synthetic enamel ordinary tint paint over a coat of red oxide primer on steel or iron surfaces of any description over 10cm in width or grith, not otherwise described complete all as specified and as directed by the Engineer-in-Charge.
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M&L preparation of newly plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller over a coat of primer over and inlcuding 1mm to 2mm thick wall care putty in two or more coats to achive smooth surface complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old decorated plastered/ unplastered surfaces of concrete ceiling and applying two coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc and applying two coats of oil emulsion distemper with painting roller over and including 2 mm thick wall care putty in two or more coats to achive smooth surfaces complete all as specified and as directed by the Engineer-in-Charge
M & L preparation of old decorated brick/concrete, plastered / unplastered surfaces of walls by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of cement base paint over prepared surfaces of wall, pillar, cornices etc complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old decorated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old decorated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M & L closing bolt holes etc. in old corrugated steel sheets or Aluminium sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm G.I. bolts and nuts, all set in stiff white lead, bolt n exc 25mm in length complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering , fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering , fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel rag or lewis bolts, screwed one end with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30cm long and 20mm dia. of neck complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
Taking down shutters of any description area exc 1 sqm and not exc 2 sqm each and removing the same site complete all as specified and as directed by the Engineer-in-Charge
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
S&F steel ventilator box type top hung shutter with partly gauge and partly glazing bar complete all as specified and as directed by the Engineer-in-Charge.
M&L mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by the Engineer-in-Charge.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing stainless steel butt hinges 100 mm long complete all as specified and as directed by the Engineer-in-Charge.
S&F 125 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing mild steel butt hinges 100 mm long medium weight cold rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 150mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel sliding door bolt plate type 300 mm long stove enamelled black with bright bolt not less 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge
Supply only mild steel butt hinges 50 mm long medium weight cold rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds and steel window frame glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 4.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F as in reapir stainless steel wire cloths 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tack or stainless steel wire staple complete all as specified and as directed by the Engineer-in-Charge
S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by the Engineer-in-Charge
S&F powder coated aluminium door made out of hollow extructed aluminium section of size 101.60 x 44.45 x 1.55 mm for chowkhat, 85 x 44.45 x 1.56 mm for vertical style of shutter, 83.5 x 44.45 x 1.54 mm for middle rail of shutter , 85 x 44.45 x 1.54 mm for top rail of shutter and 150 x 44.45 x 1.54 mm for bottom rail of shutter including neccessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as aluminium tower bolts 200 mm long (2 Nos.), hinges type B-21, 125 mm long (4 Nos.), 150 mm long aluminium handle D or disk type (2 Nos.) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 100 mm size brass mortice lock, vertical type, 6 levers with duplicate key complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, govering pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 12 mm thickness prelaminated particale board,exterior grade, prelaminated both side with decorative choice lamination and fixed to aluminium door with glazing clips, rubber etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 5.5 mm thick tinted glass to aluminium door with glazing clips, rubber etc complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium window side hung type without sash bars complete including chowkats made out of hollow aluminium section of size 100 x 44 x 1.6 mm and shutter frame made out of hollow aluminium section of size 100 x 44 x 1.6 mm including neccessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as aluminium tower bolts 150mm long (2 Nos.), hinges type B-21 100 mm long (2 Nos.), 100 mm long aluminium handle (1 No.) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing anodised aluminium grill of approved pattern to aluminium frame complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.0mm thick forsted and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, including cast iron 'S' trap 100 mm bore complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
M & L taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge
S & F 15mm bore cast copper alloy chromium plated stop valves fancy type with long shank and cup (concealed), screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type bib tap 15mm bore cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 15 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15mm with PTMT nuts of length 600 mm complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated shower rose 125mm size with or without swivel joint with arm of standard size as per site complete all as specified and as direced by the Engineer-in-charge.
S & F sinks with drainage board made out of stainless steel 1mm thick sheet for kitchen or laboratory with plugs, waste pipe, brass chromium plated coupling and wastes; in-cluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connect-ing union to pipe overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge
S&F kitchen plate rack of stainless steel sheet 1mm thickness size 900mm x 900mm x250mm complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge
S & F 500 litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge Note:- Tank shall be in white colour.
S & F 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minium complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to wall complete all as specified and as directed by the Engineer-in-Charge
S&F PVC(SWR) bends of any radius, for 110mm bore pipes, with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
M & L PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
S&F 110mm bore PVC (SWR) juction single (Single T) equal are unequal complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
M & L precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete with joints to match, except blocks or slabs complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick plain cement concrete 1:2:4, type B-0 using 12.50mm graded crushed stone aggregate as in sub base, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L concrete bed in PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate to drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 150 mm dia (internal) pipes complete all as specified and as directed by the Engineer-in-Charge. (Pipes shall be measured & paid separately).
M&L 150mm bore salt glazed stone ware drain pipe grade 'A' laid in trenches and jointed complete all as specified and as directed by the Engineer-in-Charge.
M & L cutting into existing manholes for connecting new drain, making good to pipe 50 mm dia and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing roof surfaces and applying water proofing treatment over roofs comprising of the following,Complete all as specified & as directed:- (i) Applying oil bound bitumineous primer at the rate of 0.40 Liters/Sqm as per IS 3384-1986 on prepared surfaces.Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (ii) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 Kg/Sqm, black finished reinforced with non woven polyster matt, with a thermo fusible finish,torching overlaps with a propane or butane gas torch, with a overlap of 75mm at sides and 100mm at the ends,and sealing including applying a coat of cold emulsion bitumineous primer all as per manufacturer's instruction including prepration of surface. (iii) Applying one coat of hot straight run bitumen grade 30/40 (Grade S-35) confirming to IS -73 at the rate of 1.2 Kg/Sqm. Note:- The water proofing treatment shall be carried out by manufacturer or his authorized applicators in terms of clause 11.43 of MES Sch Part-'I' (2009)
M&L machine pressed rubber moulded precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006 of 60 mm thickness grade M-35 with grey cement and no pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge
M & L factory made cement concrete kerb stone/PCC block of size 45 cm x 45 cm x 15 cm thick or as required at site made from PCC 1:1.5:3 type A1 using 20 mm graded crushed stone aggregate, hydraulically presed with plan fair faces, including chamfers, weathering, throating and jointed in cement mortor 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Demolition of Cement concrete (un-reinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Forming Contraction (Dummy)joints 75mm deep x 10mm wide,filled with sealing compound grade 'A' complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' part-II ie E/M items
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch, socket outlet, bulk head fittings, tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 3.02 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 3.02 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6/16 amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED Bulb, retrofit 9 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole and netural, 240 volt, 40 amps 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6-40 amps 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure for MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making good the disturbed surfacesincluding removing old Unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
S&F sheet metal enclosure , MCCB,DB, Vertical IP 43 & 54 type, 4 way , MCCB+12 module ,TPN, double door , powder coated complete alongwith 200 Amp rated Bus bar ,suitable and including for MCCB,4P,125 Amps as incomer and MCB's as out going suitable size of MS cabinet 2 mm thick and making all type of connections with suitable size of gland for incommer cable complete , concealed on wall surface & making good distrubed surfaces as per existing adgoining surface with taking out the existing DB's /MCCB's . Note: For electric connection of MCCB, 4 POLE suitable rating thimble / lugs should be used on cable ends. (2) Price of MCCB , 4 POLE , 125 Amps. is included in the quoted rate.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and fixing indoor decorative LED tube light fitting Batten type with opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 18/20 W LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, T5 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge.
Supply & Fixing LED Flood lights, 120 watt IP-66, aluminum die cast housing with unique lens system and toughened glass with gasket 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with flexible copper conductor to connector of the light with necessary fixing arrangements, including disconnecting and taking down existing old Unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 1.2 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over a coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old Unserviceable fitting complete all as specified and as directed by the Engineer-in-Charge.
S & F LED high bay/medium bay luminaire 80-90 W, aluminum heat sink with effective optics, IP-65 indoor type input voltage range 120-270 volts with provision of 3 core copper conductor cable 1.5 sqmm size from connector/ceiling rose to fitting with fixing arrangement as per site requirement/conditions and including removing old Unserviceable fitting complete all as specified and as directed by the Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve complete all as specified and as directed by the Engr-in-charge.
Supply and fix RCBO 40 Amps 2 Pole, 2 module 100 mA (HI immunity) sensitivity 230 volts 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix over voltage release 230 V, single phase in one module complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED tube light fitting 1x18/20 Watt, box type made from extruded aluminum high lumen out put 6500 K, AC 220-240 Volts, 50 Hz including tube rod (lamp type LED tube light fitting 1x18/20 Watt) and connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and as directed by Engineer-in-Charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 10 watt LED plastic batten with white acrylic cover, integrated LED channel and all accessories, prewired upto terminal block including connecting with 3 core copper conductor flexible cable from terminal box to the ceiling rose or connector of the light point complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing recess mounting LED 10 Watt circular down lighter/ COB panel with aluminium die cast housing, 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with 3 core flexible copper conductor from ceiling rose to connector of the light, complete all as specified and as directed by the Engr-in-charge.
S&F light grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by Engineer-in-Charge.
Supplying and fixing 1100 volts grade heavy duty 10 Sqmm cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-Charge.
M/s Mangal Construction Co.
SM ENGINEERS
Swami Enterprises
Durga Enterprises
Karishan Kumar goel
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .