Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | L1 | Accepted-AOC ok | |
| 2 | L2₹17.6 L+₹43,400 (2.52%)Rejected-AOC WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | L2 | Rejected-AOC ok | |
| 3 | L3₹18.5 L+₹1.3 L (7.30%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC ok | |
| 4 | L4₹21.3 L+₹4.1 L (23.8%)Rejected-AOC | L4 | Rejected-AOC ok | |
| 5 | L5₹22.7 L+₹5.5 L (32.1%)Rejected-AOC 1017 A SUBHASH NAGAR BEHIND KHALSA SCHOOL BAREILLY UP | BAREILLY | UTTAR PRADESH | 243001 | L5 | Rejected-AOC ok |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
2 Aug 2022, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR/ MAINT OF GEYSER, SOLAR WATER HEATER AND ALLIED WORKS UNDER GE WEST BAREILLY
2022_MES_534564_1
8070/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹74,000
Yes
22 Aug 2022
29 Jun 2022
4 Aug 2022
29 Jun 2022
2 Aug 2022
20 Jul 2022
30 Jun 2022 - 19 Jul 2022
Amount
Taking down of unserviceable bolt of existing geyser, M&L grouting of new bolt (tee type) at new place and refixing of geyser of any type and any capacity all as speified and directed by Engr in Charge.
M&L for replacement and re-filling of glass wool as per norms of different type of geysers complete all as specified and directed by the Engr in Charge.
S&F in repairs heating element 2.0 KW as triangular type/ circular type as per sample all as directed by the Engr in Charge.
S&F only new inner shell of geyser capacity 25/35 liters of suitable size made of copper sheet of 22 SWG complete with all suitable accessories complete all as specified and directed.
M&L for replacement of bottom cover in two parts of MS sheets not less than 22 gauge and pre treated in finished in white stove enameled paint as per existing size gauge in the geyser of any capacity/size complete all as specified and directed.
Supply and fixing new safety pressure valve with vent to geysers as per latest ISI specification and directed.
M&L for Painting the outer surface of geyser capacity 25/35 ltrs as per original shade with two coats of synthetic enamel paint over a coat of primer by spray gun after scrapping the existing paint ,denting etc. filling depression with putty and refixing the geyser in position including water/electric connection and testing complete all as specified and directed.
M&L for Brazing/ welding to inner copper tank at leaking spots up to five leakage of geyser of capacity 25/35/50 liters of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed.
S&F assemblly of geyser 25/35/50 ltr.capacity as specified and directed by Engg. In charge.
Supply and Fixing in repairs Indicator lamp with new indicating lamp round/square, rectangular type as required at site, SP 230Volt
Supply and Fixing in repairs PVC connection flexible heavy grade 45 cm long complete with chromium plated flair nuts with washers at both ends suitable for GI tubing 15 mm bore complete all as specified and directed.
Supply and Fixing in repairs thermostat 0 to 90 degree, ISI marked, 15 Amps capacity automatic cut off at desired temp of suitable size for Geyser
Supply and Fixing in repairs Plug top 15 Amps Make Anchor or equivalent complete all as specified.
Repair to flat plate collector type solar water heater of capacity 200 ltr. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/PUF insulation/heating element/ thermostat/cold water storage tank/gate valves/metal clamps and ensure all connection to be leakproof complete all as specified and directed. Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose/ heating element/thermostat/cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items (ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates
Repair to flat plate collector type solar water heater of capacity 300 ltr. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/ rubber hose/PUF insulation/ heating element/thermostat/cold water storage tank/gate valves/ metal clamps and ensure all connection to be leakproof complete all as specified and directed. Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/ rubber hose/heating element /thermostat/ cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items (ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates
Repair to flat plate collector type solar water heater of capacity 500 ltr. Installed on roof top of single/double storey bldg. including dismantaling, complete descaling, cleaning, brazing/welding, reassembling and testing on completion after repair work and making the solar water heater functional in each aspects by replacement of connected items such as copper tubes/solar collector glass/hot water tank/gaskets/ rubber hose/PUF insulation/ heating element/thermostat/cold water storage tank/gate valves/metal clamps and ensure all connection to be leakproof complete all as specified and directed. Note- (i) The spare parts such as copper tubes/solar collector glass/hot water tank/gaskets/rubber hose /heating element/thermostat/cold water storage tank/gate valves/metal clamps shall be shall be measured and paid separately under respected items (ii) The cost of minor parts such as nuts, bolts, PUF insulation and cleaning materials etc and cost of brazing/welding shall be deemed to be included in the quoted rates
Supply and fixing float toughened solar glass (1m × 2m) complete all as specified and directed .
supply and fixing in replacement 3/8 inch dia copper tubing complete all as specified and directed .
Supply and fixing gasket of suitable size as per sample complete all as specified and directed .
Supply and fixing rubber hose pipe of 20mm inner dia and suitable thickness complete all as specified and directed .
Supply and fixing metal clamp for fixing rubber hose pipe including nut/bolts/washers and ensuring proper leakproof connection complete all as specified and directed .
Supply and fixing heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as specified and directed .
Supply and fixing only thermostat for heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as all as specified and directed .
Supply and fixing Gun metal globe or Gate valves with ironwheel head,screwed both ends for iron pipe of 25/30 mm dia bore including taking out unserviceable valve complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified including testing after completion.
Supply , fixing in replacement and testing 25 Ltr Capacity electric Geyser including fastner and other items such as nut, bolts and plug top etc complete including removing of old U/S electric Geyser and handing over to MES E/M store yard all as specified and directed by Engr in Charge.
Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes all as directed.
M&L for concealed point wiring for one light/ fan/ bell point controlled by one switch with 1.5 Sqmm (Nominal area) PVC insulated, unsheathed, stranded copper, conductor cable FRLS (1100Volts grade) drawn in and including PVC conduits of 20 mm dia with all fittings and accessories alongwith PVC insulated cable with copper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 1. 2mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with screws,cap and washers incl. making good the disturbed surfaces complete.
All as per item no.28 here in before but for socket outlet 3/5 pin 5 amp. on the same board.
All as per per item No 028 here-in-before but for one light point controlled by two Nos of 2 way switches complete all as specified and directed.
All as per item No 028 here-in-before but for 5 Amps 3/5 Pin point on independent board
M&L for concealed point wiring with 2.5 Sqmm (Nominal area) PVC insulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher size with all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with solid copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20mm sunk pressed steel terminal box suitably flushed to wall with 3mm thick Hylum sheet cover fixed with screws & cup washers incl. making good complete.
Supply and Fixing in repairs P/switch flush type 5/6 Amp SP one way.
Supply and Fixing in repairs P/switch flush type 5/6 Amp SP two way.
Supply and Fixing in repairs P/switch flush type 15/16 Amp SP one way.
Supply and Fixing in repairs ceiling rose 2/3 terminals
Supply and Fixing in repairs lamp holder PVC Angular/ pendent/ bakelite.
Supply and Fixing in repairs buzzer, capton ding dong, AC, 230V, sigle pole.
Supply and fixing bell push switch flush type .
Supply and Fixing in repairs socket outlet ,3/5 pin 5 amp flush type
Supply and Fixing in repairs socket outlet 2 in one, 3/5 pin 5 and 15 Amp flush type
Supply and Fixing in repairs Hylem sheet 3mm thick of size 8'' X 11'' including cutting of sheet for fixing switch / socket.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 8'' x 5'' including cutting of sheet for fixing switch / socket.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 5'' x 5'' including cutting of sheet for fixing switch / socket.
Supply and Fixing in repairs MCB SPN 20 to 32 Amps 240 volts.10kA
Supply and Fixing in repairs MCB SP 6 to 32 Amps 240 volts, 10 kA.
Supply and Fixing in repairs MCB TPN 63 Amps,415V,10kA
S &F in repair MCCB 16 kA,100Amp thermal magnetic and electronic earth leakage module complete all as specified and directed.
Taking down unserviceable existing sub main wiring with aluminium conductor stranded cable upto 6 Sqmm single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed. .
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 2.5 Sqmm connected to common earth dolly and drawing into rigid PVC conduit with lock pattern incl. making good the disturbed surface complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 4 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 ways complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways complete all as specified and directed.
S&F in replacement LED fitting with PVC extruded battern 20watt 4 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed.
Supply and Fixing in repairs LED bulk head light fittings with all accessories with lamp, cover plate, 9W bulb, metal box etc complete as required as per standard make complete all as specified and directed.
S&F in repairs building security light led type 18 W complete all as specified and directed.
S&F 2'x 2' LED recess/ surface mounted fitting 36 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of PVC non metallic casing caping of 25 mm size with accessories including dismentaling/takingdown of old unserviceable/broken PVC conduit/cashing caping fixed on surface/concealed inclduing making good the disturbed surface complete all as specified and directed
S&F LED mirror light fixture 10W LED 6000K complete all as specified and directed.
Supply and Fixing in repairs in replacement PVC insulated Flexible twin core,copper cable multistranded 24/.0020sqmm, 1100 V grade.
Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed.
Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all as directed.
Supply and Fixing in repairs fan regulator resistance/electronic step piano type single phase 230 volt.
Supply and Fixing in repairs Condenser 2.5 Mfd make universal/Usha /Bajaj/Epcos.
Supply and Fixing in repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVCinsulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section in service connections
Supply and fixing 1.5 sqmm copper wire in replacement of old wire.
Supply and fixing 2.5 sqmm copper wire in replacement of old wire.
Supply and fixing 4.0 sqmm copper wire in replacement of old wire.
Notes :- (i) For Serial No 01 to 71: The Contractor has to complete the work assigned for above items with in 36 hours failing in which recovery at the rate 25 Rs. per day per complaint. (ii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint cell and get them signed from user after completing the job and submit to E/M complaint cell.
N S ELECTRICALS
prabhave traders
URBANS CONSTRUCTIONS
K.S.Traders
M/s. S.S. Refrigeration, Bareilly
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .