Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹6.9 Laccepted-aoc | ₹6.9 L | accepted-aoc |
Tender Value
₹8.6 L
EMD Value
₹8,589
Closing Date
24 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER, RWS DIVISION, NELLORE
NELLORE
Operation and Maintenance of CPWS Scheme to Kondapuram and 13 Other habitations in Kondapuram mandal of SPSR Nellore District for the year of 2026-27, Est Cost Rs. 13.00 lakhs
916585
277/2025-26, Dated: 12.03.2026 of the Executive Engineer, RWS&S Division, Nellore
OPEN - NCB
Water Supply
SRI POTTI SRI RAMULU NELLORE
8 documents required · 8 mandatory
₹305
₹8,589
8 Apr 2026
18 Mar 2026
18 Mar 2026
Labour chrages of Watchman for guarding the Operation and Maintenance of CPWS Scheme to Kondapuram and 13 Other habitations in Kondapuram mandal of SPSR Nellore District for the year of 2026-27 period from 01.04.2026 to 30.09.2026 (183 Days)
Operation and Maintenance of CPWS Scheme to Kondapuram and 13 Other habitations in Kondapuram mandal of SPSR Nellore District for the year of 2026-27 for Supply of potable (chlorinated) drinking water at the specified quantity as per drinking water quality standards to all the habitations mentioned in the schedule through the existing network system comprising of infrastructure viz. RSF, OHBR, Service Reservoirs i.e. OHSRs, GLSRs etc., including all operating expenses like wages to the system staff and other amenities applicable as per the labour act, Mobility/transportation facilities etc., for the designated qualified Pump operators, Electricians, Fitters, Helpers, Watchmen etc. for carrying out of all operations involved in drawing of raw water from source, treatment and supply of drinking water as per the guidelines of CPHEEO manual/Department at the rate of 40LPCD with relevant IS specifications wherever applicable and with highest quality standards. The scope of work also includes routine, periodic, breakdown and preventive maintenance, staffing and engaging manpower under Operation & Maintenance. The turbidity of supplied water shall be maintained below 1 NTU and should not exceed 5NTU by mixing alum in raw water duly arriving the Alum dosage by jar test. Disinfection with Bleaching Powder/Liquid Chlorine/Gas Chlorination shall be taken up to maintain Residual Chlorine not less than 0.2ppm in pipe lines at last FHTC in the tail end habitations. The scope of work includes taking up of all other incidental activities pertaining to the Operation and Maintenance of CPWS Scheme and to follow all standard procedures by the agency as directed by the Employer/Engineer of the department. The Rate per KL is applicable to supply potable (chlorinated) drinking water by engaging system staff for Operation & Maintenance of said CPWS Scheme (The rate is excluding cost of consumables, power consumption charges, Repairs and Renewals and GST) for the Period from 01.10.2026 to 31.03.2027 (182Days). (Annexure is enclosed for the System staff & Habitations list)
Supply, delivery and staking of Bleaching Powder as per I.S 1065-1989, Table - 1, Grade - I, including cost and conveyance of material, stacking at the location specified by the Department and all taxes, duties and levies etc.complete. (Available Chlorine percent by mass 34%)
Repairs and Renewals :
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.90 x 1.12 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 250mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work etc.exclusding GST, complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.80 x 1.10 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 200mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.80 x 1.10 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 160mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.70 x 1.00 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 110mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.70 x 1.00 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 90mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.70 x 1.00 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 63mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.90 x 1.12 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 225mm dia HDPE Pipe PE-100 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipeliness in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.80 x 1.10 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 180mm dia HDPE Pipe PE-100 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Cost and Supply of 250mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 200mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 160mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 110mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 90mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 63mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 225mm dia HDPE Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 180mm dia HDPE Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 250mm dia CID Joints including all labour charges
Cost and Supply of 150mm dia CID Joints including all labour charges
Cost and Supply of 100mm dia CID Joints including all labour charges
Cost and Supply of 200mm dia PVC Collar including all labour charges
Cost and Supply of 250mm dia PVC Collar including all labour charges
Cost and Supply of 225mm dia HDPE Collar including all labour charges
Cost and Supply of 180mm dia HDPE Collar including all labour charges
Cost and Supply of 250mm dia MS Flangeset including all labour charges
Cost and Supply of 225mm dia MS Flangeset including all labour charges
Cost and Supply of 200mm dia MS Flangeset including all labour charges
Cost and Supply of 180mm dia MS Flangeset including all labour charges
Cost and Supply of 200mm dia PVC Coupling including all labour charges
Cost and Supply of 160mm dia PVC Coupling including all labour charges
Cost and Supply of 110mm dia PVC Coupling including all labour charges
Cost and Supply of 90mm dia PVC Coupling including all labour charges
Cost and Supply of 63mm dia PVC Coupling including all labour charges
Cost and Supply of 63mm dia PVC Bend including all labour charges
Cost and Supply of 63mm dia PVC FTA including all labour charges
Cost and Supply of 5/8th Bolts and Nuts including all labour charges
Cost and Supply of Rubber packing 6mm thick including all labour charges
Repairs to 7.50 HP submersible motor at source at Ralapadu Reservoir D/w side
Labour charges for removal of burnt pumpset from the source
Labour charges for rewinding of pumpset with new copper wire
Cost and supply of PVC insulated and PVC sheathed, flexible 3 core flat type cable 4.00 Sqmm for submersible pumpsets,conductors composed of annealed high conductivity copper wire, confirming to IS 694 & its revisions and amendments from time to time delivery at site of installation of pumpsetincluding CP @ 13.615%
Cost of Pumpset service charges
Cost and Supply of bushes
Cost and Supply of impellers
Installation charges of motor with all accessories
Conveyance charges from work place to Shop
Conveyance charges from Shop to Work Place
Repairs to 10 HP Centrifugal Monoblock pumpset at Sump in Audimurthipuram
Labour charges for removal of burnt pumpset from the source
Labour charges for rewinding of pumpset with new copper wire
Cost and supply of PVC insulated and PVC sheathed, flexible 3 core flat type cable 4.00 Sqmm for submersible pumpsets,conductors composed of annealed high conductivity copper wire, confirming to IS 694 & its revisions and amendments from time to time delivery at site of installation of pumpsetincluding CP @ 13.615%
Cost of Pumpset service charges
Cost and Supply of bushes
Cost and Supply of Pump Bearing
Cost and Supply of impellers
Cost and Supply of Banjar cable
Installation charges of motor with all accessories
Conveyance charges from work place to Shop
Conveyance charges from Shop to Work Place
Repairs to 3 HP submersible motor at Thuruyerraballi
Labour charges for removal of burnt pumpset from the source
Labour charges for rewinding of pumpset with new copper wire
Cost and supply of PVC insulated and PVC sheathed, flexible 3 core flat type cable 2.50 Sqmm for submersible pumpsets,conductors composed of annealed high conductivity copper wire, confirming to IS 694 & its revisions and amendments from time to time delivery at site of installation of pumpsetincluding CP @ 13.615%
Cost of Pumpset service charges
Cost and Supply of bushes
Cost and Supply of Pump Bearing
Installation charges of motor with all accessories
Conveyance charges from work place to Shop
Conveyance charges from Shop to Work Place
(68 - Sixty Eight Items) -------- Total : Rs.
Labour chrages of Watchman for guarding the Operation and Maintenance of CPWS Scheme to Kondapuram and 13 Other habitations in Kondapuram mandal of SPSR Nellore District for the year of 2026-27 period from 01.04.2026 to 30.09.2026 (183 Days)
Operation and Maintenance of CPWS Scheme to Kondapuram and 13 Other habitations in Kondapuram mandal of SPSR Nellore District for the year of 2026-27 for Supply of potable (chlorinated) drinking water at the specified quantity as per drinking water quality standards to all the habitations mentioned in the schedule through the existing network system comprising of infrastructure viz. RSF, OHBR, Service Reservoirs i.e. OHSRs, GLSRs etc., including all operating expenses like wages to the system staff and other amenities applicable as per the labour act, Mobility/transportation facilities etc., for the designated qualified Pump operators, Electricians, Fitters, Helpers, Watchmen etc. for carrying out of all operations involved in drawing of raw water from source, treatment and supply of drinking water as per the guidelines of CPHEEO manual/Department at the rate of 40LPCD with relevant IS specifications wherever applicable and with highest quality standards. The scope of work also includes routine, periodic, breakdown and preventive maintenance, staffing and engaging manpower under Operation & Maintenance. The turbidity of supplied water shall be maintained below 1 NTU and should not exceed 5NTU by mixing alum in raw water duly arriving the Alum dosage by jar test. Disinfection with Bleaching Powder/Liquid Chlorine/Gas Chlorination shall be taken up to maintain Residual Chlorine not less than 0.2ppm in pipe lines at last FHTC in the tail end habitations. The scope of work includes taking up of all other incidental activities pertaining to the Operation and Maintenance of CPWS Scheme and to follow all standard procedures by the agency as directed by the Employer/Engineer of the department. The Rate per KL is applicable to supply potable (chlorinated) drinking water by engaging system staff for Operation & Maintenance of said CPWS Scheme (The rate is excluding cost of consumables, power consumption charges, Repairs and Renewals and GST) for the Period from 01.10.2026 to 31.03.2027 (182Days). (Annexure is enclosed for the System staff & Habitations list)
Supply, delivery and staking of Bleaching Powder as per I.S 1065-1989, Table - 1, Grade - I, including cost and conveyance of material, stacking at the location specified by the Department and all taxes, duties and levies etc.complete. (Available Chlorine percent by mass 34%)
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.90 x 1.12 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 250mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work etc.exclusding GST, complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.80 x 1.10 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 200mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.80 x 1.10 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 160mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.70 x 1.00 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 110mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.70 x 1.00 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 90mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.70 x 1.00 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 63mm dia PVC 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipelines in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.90 x 1.12 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 225mm dia HDPE Pipe PE-100 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Repairs to Pipeline for water supply with PVC pipes as per IS 4985-1988 with its amendments and revisions there on excluding Cost of pipes and including of lowering, Laying and Jointing of pipeline true to alignment and gradient, specials as per requirements, trench excavation for pipeliness in all soils except Rock Required blasting by manually and depositing on bank with an initial lead and lift in all soils for pipeline trench of size 0.80 x 1.10 m including setting out, bracing, removal of stumps and other deleterious material and disposal upto a lead of 50M, dressing of sides and bottom, lowering, laying and jointing of 180mm dia HDPE Pipe PE-100 6Kg/Cm2 Pipe pipelines true to alignment and gradient and refilling trenches with excavated earth (other than rock soils) with watering and removing surplus earth from the site of work and filling pipeline with water and testing etc., complete, the rates inclusive of cost and conveyance of all materials and labour charges including turnover taxes for finished item of pipeline work but excluding GST etc., complete
Cost and Supply of 250mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 200mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 160mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 110mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 90mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 63mm dia PVC Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 225mm dia HDPE Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 180mm dia HDPE Pipe line 6Kg/cm2 including all labour charges
Cost and Supply of 250mm dia CID Joints including all labour charges
Cost and Supply of 150mm dia CID Joints including all labour charges
Cost and Supply of 100mm dia CID Joints including all labour charges
Cost and Supply of 200mm dia PVC Collar including all labour charges
Cost and Supply of 250mm dia PVC Collar including all labour charges
Cost and Supply of 225mm dia HDPE Collar including all labour charges
Cost and Supply of 180mm dia HDPE Collar including all labour charges
Cost and Supply of 250mm dia MS Flangeset including all labour charges
Cost and Supply of 225mm dia MS Flangeset including all labour charges
Cost and Supply of 200mm dia MS Flangeset including all labour charges
Cost and Supply of 180mm dia MS Flangeset including all labour charges
Cost and Supply of 200mm dia PVC Coupling including all labour charges
Cost and Supply of 160mm dia PVC Coupling including all labour charges
Cost and Supply of 110mm dia PVC Coupling including all labour charges
Cost and Supply of 90mm dia PVC Coupling including all labour charges
Cost and Supply of 63mm dia PVC Coupling including all labour charges
Cost and Supply of 63mm dia PVC Bend including all labour charges
Cost and Supply of 63mm dia PVC FTA including all labour charges
Cost and Supply of 5/8th Bolts and Nuts including all labour charges
Cost and Supply of Rubber packing 6mm thick including all labour charges
Labour charges for removal of burnt pumpset from the source
Labour charges for rewinding of pumpset with new copper wire
Cost and supply of PVC insulated and PVC sheathed, flexible 3 core flat type cable 4.00 Sqmm for submersible pumpsets,conductors composed of annealed high conductivity copper wire, confirming to IS 694 & its revisions and amendments from time to time delivery at site of installation of pumpsetincluding CP @ 13.615%
Cost of Pumpset service charges
Cost and Supply of bushes
Cost and Supply of impellers
Installation charges of motor with all accessories
Conveyance charges from work place to Shop
Conveyance charges from Shop to Work Place
Labour charges for removal of burnt pumpset from the source
Labour charges for rewinding of pumpset with new copper wire
Cost and supply of PVC insulated and PVC sheathed, flexible 3 core flat type cable 4.00 Sqmm for submersible pumpsets,conductors composed of annealed high conductivity copper wire, confirming to IS 694 & its revisions and amendments from time to time delivery at site of installation of pumpsetincluding CP @ 13.615%
Cost of Pumpset service charges
Cost and Supply of bushes
Cost and Supply of Pump Bearing
Cost and Supply of impellers
Cost and Supply of Banjar cable
Installation charges of motor with all accessories
Conveyance charges from work place to Shop
Conveyance charges from Shop to Work Place
Labour charges for removal of burnt pumpset from the source
Labour charges for rewinding of pumpset with new copper wire
Cost and supply of PVC insulated and PVC sheathed, flexible 3 core flat type cable 2.50 Sqmm for submersible pumpsets,conductors composed of annealed high conductivity copper wire, confirming to IS 694 & its revisions and amendments from time to time delivery at site of installation of pumpsetincluding CP @ 13.615%
Cost of Pumpset service charges
Cost and Supply of bushes
Cost and Supply of Pump Bearing
Installation charges of motor with all accessories
Conveyance charges from work place to Shop
Conveyance charges from Shop to Work Place
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Kondapuram - 13.00 Lakhs.xls
TENDER_DOCUMENT • 0.09 MB
Kondapuram+BOQ.xls
TENDER_DOCUMENT • 0.57 MB
Tender doc (less than 50) -24-25.doc
TENDER_DOCUMENT • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .