EXECUTIVE ENGINEER ELECTRIC DIVISION BARAMULLA
EXECUTIVE ENGINEER ELECTRIC DIVISION BARAMULLA
Rate Contract for Creation of 63 kVA Sub Station along with laying of HT/LT network at village Rampora A Uri under Capex 2020-21
2021_PDD_116902_1
EDB/65
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Rate Contract for Creation of 63 kVA Sub Station a
Refer SBD
6 documents required · 6 mandatory
₹145
Yes
EXECUTIVE ENGINEER ELECTRIC DIVISION BARAMULLA
Exempted
16 Mar 2021
16 Feb 2021
1 Mar 2021
16 Feb 2021
27 Feb 2021
17 Feb 2021
16 Feb 2021 - 17 Feb 2021
Supply,Carraige upto site, Installation, testing and Commissioning of 11/0.433KV,63 KVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2
Carriage from Divisional Stores up to site, Installation, testing and Commissioning of 11/0.433KV,63 KVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2
Supply,Carraige upto site, Erection, testing and commissioning of 09 mtr long Steel Tubular Pole with planting depth of 1/6th of the height of the pole, (9 mtr. Long ) (ST-410 SP33)
Carriage from Divisional Stores up to site, Erection, testing and commissioning of 09 mtr long Steel Tubular Pole with planting depth of 1/6th of the height of the pole, (9 mtr. Long ) (ST-410 SP33)
Supply,Carraige upto site, Erection, testing and commissioning of 08 mtr long Steel Tubular Pole with planting depth of 1/6the of the height of the pole, (8 mtr. Long ) (ST-410 SP15)
Carriage from Divisional Stores up to site, Erection, testing and commissioning of 08 mtr long Steel Tubular Pole with planting depth of 1/6the of the height of the pole, (8 mtr. Long ) (ST-410 SP15)
Supply,Carraige upto site, laying , stringing, tensioning, binding of ACSR Conductor, (30sqmm ACSR Conductor)
Carriage from Divisional Stores up to site, laying , stringing, tensioning, binding of ACSR Conductor, (30sqmm ACSR Conductor)
Supply, Carriage up to site, and fixing of MS V-Cross & F-Top duly fabricated as per REC Standards including clamps(50x6 mm) & MS Nuts & Bolts
Supply,Carraige upto site, and fixing of MS Channel Iron x-arm 9' long 100x50x6mm including suitable clamps/collars
Supply,Carraige upto site, and fixing of MS Channel Iron x-arm 9' long 75x40x6mm including suitable clamps/collars
Supply, Carriage up to site, Installation, testing and Commissioning of 11 KV Pin Insulators (Porcelain with Pins (5KN)
Supply, Carriage up to site, Installation, testing and Commissioning of 11 kV G.O AB Switch , 3-phase, 3 pole 400A polymer Stn. Type
Supply, Carriage up to site, Installation, testing and Commissioning of of 11 kV D O Fuse 3phase 400A polymer Stn. Type
Supply, Carriage up to site, Installation, testing and Commissioning of Gapless Surge Arrestor,9 KV ,10 KA ,LA with polymer Stn. Type
Supply, Carriage up to site, Installation, testing and Commissioning of LT Fuse Sets (Pre-fabricated)
Supply, Carriage up to site, laying , stringing, tensioning, binding of 1.1 KV grade, 185 sq-mm 1-core PVC Cable
Supply, Carriage up to site, Installation, testing and Commissioning of 185 Sqmm Aluminum Thimbles
Supply, Carriage up to site, Installation, testing and Commissioning of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply, Carriage up to site, Installation, testing and Commissioning of M. S Flat (50x6 mm), LT Structure Mukhi type including LT Shackle insulators (Porcelain 16 KN) as per REC Standard
Supply, Carriage up to site, and fixing of MS nuts and bolts of sizes
Supply, Carriage up to site, and fixing of Substation Sign board
Supply, Carriage up to site, and fixing of Substation Sign board and Danger Plate
Painting of 8/9 MTR ST Poles with one coat of Red Oxide and two coats of aluminum paint
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole (Pit 600x600x1600 mm) for 9 MTR ST Pole
Providing , commissioning of Earthing of ST Poles complete by 8SWG GI Wire closely wound 115 turns, spiral spring length 450mm & width 50 mm as per REC Standards
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mmx10 mm & 50 mmx6 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover.
M/s M J ELECTRICALS CONSTRUCTIONS
M/S H.B.C ENGINEERING
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .