| 1 | L-1₹67.4 LAccepted-AOC | L-1 | Accepted-AOC L-1 Bidder | |
| 2 | L-2₹68.2 L+₹73,660.32 (1.09%)Rejected-AOC GOYAL NIWAS POWER HOUSE ROAD SAPRRON SOLAN H P | SOLAN | SOLAN | HIMACHAL PRADESH | L-2 | Rejected-AOC L-2 bidder | |
| 3 | L-3₹69.1 L+₹1.7 L (2.46%)Rejected-AOC 1286 3 SHASHRI NAGAR MEERUT | MEERUT | L-3 | Rejected-AOC L-3 bidder | |
| 4 | L-4₹70.2 L+₹2.7 L (4.06%)Rejected-AOC | L-4 | Rejected-AOC L-4 bidder |
Tender Value
₹74.3 L
EMD Value
₹1.9 L
Closing Date
5 Jul 2021, 11:30 amClosed
Chief Engineer OP South
O/o Chief Engineer OP south Shiimla-04
SOP for Augmentation and Integration of Water Supply Scheme of Matiana, Kumarsain, Sainj and surrounding Villages Interim/Permanent arrangement complete in all respect on Turnkey/ Partial Turnkey basis in Electrical Division HPSEBL Kumarsain
2021_HPSEB_47970_1
. CEO/MC/T. No.02/SOP for AI WSS K.Sain/2021
Open Tender
Supply and Erection
Item Rate
120 days
Rampur Bushar
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,900
AO Banking FA , HPSEBL
₹1.9 L
30 Sept 2021
3 Jun 2021
6 Jul 2021
3 Jun 2021
5 Jul 2021
3 Jun 2021
Amount
Power Transformer (4 MVA ,22/11KV , ONAN , OLTC, Outdoor) Bi-Directional Type
22 KV incomer Control and relay (CR) panel with indoor VCB ( 22 KV, 1250 A, 25 kA ) Numeric relay) ,including CT ratio 150/5 A
22 KV Isolator ( 1250 A, 25 KA , without earth switch and with Structure )
22 KV LA/ Surge Arrestor ( 20 KV . 10 KA , Station Class, ZnO, Porcelain)
22 KV Current Transfromer /Potential Transfromer (CT /PT) unit Combined 3 phase( for metering purpose)
22 KV Drop out Fuse Unit ( 22 KV , expulsion )
22 KV Cable ( 22 kv ,185 mm2 , XLPE , Three Core,Armoured { 50 m + Spare -50 m)
22 Kv Cable Termination kit ( 185 Sq. mm, outdoor)
22 Kv Cable Termination kit ( 185 sq. mm, indoor)
11 KV Switchgear Allied Equipment : 11 KV incomer bus Control and relay (CR) panel with indoor VCB ( 12 KV, 1250 A, 25 kA ) Numeric relay ,CT ratio 300/5 A with PT
11 KV Cable ( 11 kv ,185 mm2 , XLPE , Three Core,Armoured) { 50 m + Spare -50 m)
11 KV Cable Termination kit ( 185 Sq. mm, outdoor)
11 Kv Cable Termination kit ( 185 sq. mm, indoor)
11 KV Isolator 1250Amp 25 KA, without Earth Switch & with Str.
11 KV Switchgear Allied Equipment : 11 KV outgoing feeder Control and relay (CR) panel with indoor VCB ( 12 KV, 1250 A, 25 kA ) Numeric relay ,including CT with CT Ratio 300/5 A and PT 11/0.11 KV
11 KV Cable ( 11 kv ,185 mm2 , XLPE , Three Core,Armoured) { 50 m + Spare -50 m)
11 Kv Cable Termination kit ( 185 Sq. mm, outdoor)
11 Kv Cable Termination kit ( 185 sq. mm, indoor)
Battery Bank with battery charger ( 15 no x 2V cell, Lead acid ,30 V, 100 AH)
Distribution panel (30 V DC)
Distribution panel (415 V, AC)
Bus Bar: 3 disc insulator tension string complete with fitting
ACSR Conductor 100 mm2 at 10% wastage
Tee Connections
PG Clamp
Pipe Earthing (22 KV Power Substation+ 22 KV incoming panel+ 11 KV Panel )
Steel Tubular Pole 11 Mtr Long
RCC Muff
Aluminium Paint
Earthing Mat
Civil Works : Transformer Foundation
Trenches
22 KV HT LINE (The Size of Cross Arms shall depend as per Site Conditions)
ACSR 30/7/2.59 includes 3 conductor length for 3 phase and additional 1% ( sag jumpering and wastage)
ST Poles (11 m, working load > 227 kgf/sq m.)(with Ruling Span 90 m, run thro, Double Pole Dead end Structure
Muffs with Concrete Filling
Run Through Strucure( Formation): On double pole structure Cross Arm (Channel Iron (100X50X6 mm)
Cross Arm {Angle Iron ( 50x 50x6 mm)}
Full Clamp
22 KV Pin Insulator with GI pin
DEAD END STRUCTURE : Cross Arm Channel Iron (100X50X6 mm)
X-Bracing set-MS Angle Iron: 50X50X6mm as per specifications
Discs Insulator Sets on dead End Structures( Comprising 1 No. Disc : ( porcelain , BS, 12 KV , 90 KN ) includingd dead end clamps etc) x ( 3 No. Conductors) x (2 No. Sides)
22 KV Pin Insulators ( Porcelain , 22 KV , 10 KN): 3 No per double pole structure
HT Stay/ Guy Arrangement: Stay set complete in all respect
Stay wire (7/3.15 mm) (6.0 kg per stay set)
EARTHING: HT Earthing set complete
Single Continous earth wire ( GI, 8 SWG) 9 Alongwith 1 wire lengths for avg. on road crossing @ 20m and additional 1% ( sag and wastage ) @ 0.102 kg/m
Eye hook for earth wire
Earth wire clamp
Cross Arm (MS Angle Iron: 50 x 50 x6mm),
Full Clamp :( On double Pole dead End Structure)
Danger Plate (250X 250x 1.6 mm)
Nuts and Bolt various sizes ( Galvanised / Coated) [Preferably 16 mm or more ( with flat and spring washers)]
Barbed Wire
Aluminium Paint
GO Switch 22 KV
11 KV HT LINE (The Size of Cross Arms shall depend as per Site Conditions)
ACSR 30/7/2.59 includes 3 conductor length for 3 phase and additional 1% ( sag jumpering and wastage)
ST Poles (11 m, working load > 227 kgf/sq m.)(with Ruling Span 90 m, 8 no. run thro, Double Pole Dead end Structure
Muffs with Concrete Filling
Run Through Strucure( Formation): On double pole structure Cross Arm [ Channel Iron (100X50X6 mm)
Cross Arm M.S. Angle Iron ( 50x 50x6 mm),
Full Clamp
11 KV Pin Insulator Porcelain 12 KV, 10 KN with Pin.
Dead End Structure: ( Adopt 3 No. /Km) on double pole) Cross Arm [ Channel Iron (100X50X6 mm)
X-Bracing set-MS Angle Iron: 50X50X6mm,
Discs Insulator Sets on dead End Structures( Comprising 1 No. Disc : ( porcelain , BS, 12 KV , 90 KN ) includingd dead end clamps etc) x ( 3 No. Conductors) x (2 No. Sides)
11 KV Pin Insulator (porcelain 12 KV, 10 KN ) with Pin
HT Stay/ Guy Arrangement Stay set complete in all respect
Stay wire (7/3.15 mm) (6.0 kg per stay set)
Earthing HT Earthing set complete
Single Continous earth wire ( GI, 8 SWG) 9 Alongwith 1 wire lengths for avg. on road crossing @ 20m and additional 1% ( sag and wastage ) @ 0.102 kg/m
Eye hook for earth wire
Earth wire clamp
Cross Arm MS Angle Iron: 50 x 50 x6,
Half Clamps:( on Run Thro Structure):
Full Clamp :( On double Pole dead End Structure )
Danger Plate (250X 250x 1.6 mm)
Nuts and bolt various sizes ( Galvanised / Coated) [Preferably 16 mm or more ( with flat and spring washers)]
Barbed Wire
Aluminium Paint
GO Switch 22 KV
DISTRIBUTION SUB STATION (The Size of Cross Arms shall depend as per Site Conditions)
Distribution Transformer outdoor type 11/ 0.4 KV, 250 KVA
Distribution Transformer outdoor type 11/ 0.4 KV, 100 KVA
Steel tubular Poles 11 m
Muffs with concerete filling
X- Arm [Channel iron ( 100x 50x6 mm, length : 2800 mm x 2 nos & GO Switch)
X- Arm [Channel iron ( 75x40x6 mm, length : 2800 mm x 4 nos for supporting DO Fuse Unit)
Cross Arm MS Angle iron ( 35x35x5 mm) Length: 460 mm x 2 Nos
Cross Arm MS Angle iron ( 50x50x6 mm) Length 2800 mm x 1 Nos for LA, Transformer belt
Transfromer bed [ Civil work] As per Specifications
G.O switch unit 11 KV 400 A, 25 KA,
D.O.Fuse unit
Surge Arrestor, 9 Kv Station Class
Disc insulator Set
Stay Set complete
Stay wire (7/3.15 mm) ( 6.0 kg per stay set)
Pipe earthing set
Half clamp ( MS Flat 50x5 mm)
Nuts and bolts of various sizes
Aluminium Thimble
Copper Thimble
Danger Plate
Chain Link Fencing, Angle iron , gate etc for transformer fencing as per Specification
L.T . Cable ( 3.5 Core ) 95 mm2
L.T. Cable ( 3.5 Core ) 70 mm2
Energy Meter ( 3 phase , 4 wire ) DLMS compliant 400 A CT Type
Aluminium Paint
HIM ELECTRICALS
ARUN ELECTRICALS INDIA
UTRI HR Services Private Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .