Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.5 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹86.8 L+₹2.0 L (2.37%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹97.7 L+₹13.0 L (15.3%)Rejected-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical 20 1 CHANDRA NIVAS APPLEBY ROAD WELLINGTON COONOOR NILGIRIS 643 232 | COONOOR | NILGIRIS | TAMIL NADU | 643232 | - | Rejected-Technical Documents found not correct. |
| Sl No | Description | Qty | Unit | Glacier Cooling Solutions Private Limited L3 | Shree Ayyappa Engineering L1 | cooltech engineering services L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning of 3 x 15 TR (Each for AV - II & AV III) nominal cooling capacityof 13.7 TR, factory-assembled water cooled Scroll condensing unit, with microprocessor based control panel with all safety devices, Hermetically sealed scroll compressors, Shell and Tube Condenser, all safety devices, suitable for operation on R-410A or R-407C refrigerants, s per OEM recommendation complete and required foundation for pumpset complete all as recommended by OEM a and as directed
Make: Carrier/ Bluestar/ Daikin. | 2 | Each Job | 10,18,000 ₹20,36,000 | 9,55,000 ₹19,10,000 Lowest | 9,81,050 ₹19,62,100 |
| 1.10Note for item No.1 (i)The AC plant and other accessories shall be commissioned by OEM. (ii)The contractor shall submit a certificate from the OEM confirming that the entire AC plant work shall be got installed through them/ their accredited agencies duly incorporating thier recommended make. For this the contractor shall obtain the certificate for this from the OEM branch office located in Kochi.(iii) The AC plant and AHUs will be housed in the existing plant room at NAY. (iv)The tenderer should visit the site and check the site conditions before quoting the tender so as to incorporate any changes needed to install the plant in the location and rate quoted shall be included in the quote. (v) First charge of refrigerant, compressor oil,lubricants etc and maintaining it at desired level even when leakage occurs during defect liability period is deemed to be the responsibility of the tenderer. (vi) Before commencement of the work contractor shall obtain design details including drawing from OEM and submit the OEM vetted drawing for approval of accepting officer duly supported with all relevant specifications of each components of AC plant . (vii) Any accessories required to be removed during the dismantling and installation of DX units shall be repaired /replaced to the existing shape as per site requirement and as directed by EIC.The cost required for the same shall be deemed to be included in the cost incuding Modification work of Civil Foundation of already existing foundation for old chiller units. (viii) If the required capacity is not available, next higher capacity shall be provided by the contractor and same is deemed to be included in the cost. (ix) THE OEM Should have service setup in kochi area. (x) Any item/accessories left out inthe contract for suceeful completion of the work shall be provided by the contractor and cost of the same is deemed to be included in the cost. (xi) Foundation of the chiller plant as per OEM specification. (xii) Contractor should supply and fix in plant room, colour print of Chiller plant drawing with plant details in a sandwiched type acrylic display board not less than 90 cm x 60cm size. (xiii) Any Civil workd required during execution of work such as wall cutting/demolishing, dismantling of window/doors and refixing to its original form and any addition/alteration required to the bldg of AC plant such as brick mansonry work and distempering of the same to be included in the above quoted rate complete all as specified and as directed. | ||||||
| 2.00 | Supply and installation of refrigerant piping using appropriately sized 18 SWG grade hard-drawn copper pipes and fittings, including insulation of the suction pipe with 19 mm thick nitrile rubber tubular foam, and painting the liquid pipe with approved colour enamel paint, as per the manufacturer’s instructions, specifications, and directions. | 120 | RM | 2,850 ₹3,42,000 | 900 ₹1,08,000 Lowest | 950 ₹1,14,000 |
| 3.00 | Supply, installation, testing, and commissioning of indoor floor-mounted Air Handling Unit, fabricated from outer skin with 0.63mm thick precoated GSS sheet and plain 0.63 mm thick GSS inner sheet with 40mm thick injected PUF insulation with an aluminum extruded framework a) Pre-filters having efficiency 90% down to 20 microns in GSS/ Aluminium frame and Bag filters having efficiency 90% down to 3 microns in GSS/ Aluminium frame (b) 6/8 row deep DX type intertwined coil section with aluminum fin and copper tube, suitable brass distributor and copper header, and SS-304 sheet fabricated nitrile rubber insulated drain pan (c) Fan section with VFD compatible Plugtype/Belt driven Blower and 3 Phase motor. (d) Aluminum volume control dampers on Supply air mouth. (e) Marine light and safety interlocks all as specified and as directed to be installed to achieve the room condition 23 ± 2 degrees Celsius. Selected cooling capacity - 15 TR x 3 Ckt (Each for AV - II & AV III) Selected CFM: 16000 @ 80 mm of 'wc' TSP each | 2 | Each | 7,95,000 ₹15,90,000 Lowest | 9,60,000 ₹19,20,000 | 9,75,050 ₹19,50,100 |
| 4.00 | Supply and installation of Thermostatic expanssion valve and drier suitable for 15Tr capacity ac plant with necessary fittings all as per standard and as directed. | 6 | Each | 14,400 ₹86,400 | 8,440 ₹50,640 Lowest | 8,450 ₹50,700 |
| 5.00 | Supply, install, test, and commissioning of FRP-induced draft cooling tower with spray section, honey comb fills, basin, Fan with motor, intake bird screen type cooling tower of capacity 50 TR with suitable foundation and float valve of suitable sizes and quick fill complete all as specified and as directed. (Each for AV - II & AV III)
Note: Rate quoted shall deemed to be inclusive of foundation of cooling tower as per OEM recommendation | 2 | Each | 1,95,000 ₹3,90,000 Lowest | 2,20,000 ₹4,40,000 | 2,20,090 ₹4,40,180 |
| 6.00 | Nonchemical type on-line scale preventor on line electrostatic non chemical water treatment system with electrically operated control panel to be fixed on main header suittable for AC Plant 45 TR. The outer casing shall be of 304 grade stgainless steel with both ends flanged and capable preventing scale formation. The same shall be suitable for water flow rate 1368 LPM complete all as specified and as directed.. | 2 | Each | 2,55,000 ₹5,10,000 | 62,000 ₹1,24,000 Lowest | 62,070 ₹1,24,140 |
| 7.00 | Supply, install, testing, and commissioning monoblock/Split case centrifugal water pumping sets for condenser water circulation (1W + 1 S) having flow rate of 10.6 LPS and delivery head of 36 m along with 3 phase, 50 cycles, 410 volts, AC motor, CI body and impeller, SS shaft, mechanical seal and suitable foundation with neoprene rubber anti-vibration ribbed pads complete all as specified and as directed. | 4 | Each | 68,500 ₹2,74,000 | 25,000 ₹1,00,000 Lowest | 25,050 ₹1,00,200 |
| 8.00 | Supply, install, testing, and commissioning Duct/Plenum mount type Heater bank 12 KW capacity (4KW x 3 nos) (Each for AV - II & AV III) with necessary control panel including safety thermostat, digital humidistate, Aerostate, and required power and control wiring all as specified and as directed. | 2 | Each Set | 25,000 ₹50,000 Lowest | 35,000 ₹70,000 | 35,040 ₹70,080 |
| 9.00Supply and installation of medium grade GI pipes for condenser water piping, cut to the required length and installed with welded joints including all necessary fittings such as elbows, tees, bends, short pieces, etc., and conforming to the specifications and painting with one coat of red oxide primer and two coats of synthetic enamel paint complete including providing necessary supports, complete all as specified and directed. The pipes shall be of the following sizes:- | ||||||
Tender Value
₹98.1 L
EMD Value
₹1.7 L
Closing Date
24 Oct 2025, 6:00 pmClosed
SHRI RK SINGH IDSE CWE NW KOCHI
CWE(NW) KOCHI
SPECIAL REPAIR REPLACEMENT OF BER AC PLANT AT NAY KOCHI
2025_MES_731839_1
CWE(NW)KOCHI/81601
Open Tender
Civil Works
Item Rate
240 days
KOCHI
As per NIT
6 documents required · 6 mandatory
₹1,000
GE(NS) KOCHI
₹1.7 L
Yes
2 Dec 2025
20 Sept 2025
28 Oct 2025
20 Sept 2025
24 Oct 2025
10 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
Tenderdocument.pdf
Tender Documents • 1.25 MB
BOQ_819358.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .