| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC Lowest rate. | |
| 2 | L2₹4.9 L+₹3,900 (0.80%)Rejected-Finance KAYETPARA NANDIGHAT RANAGHAT NADIA 741255 | RANAGHAT | NADIA | WEST BENGAL | 741255 | L2 | Rejected-Finance Higher Rate. | |
| 3 | L3₹5.0 L+₹5,400 (1.10%)Rejected-Finance 25 NEW MALLICK COLONY PAT BARI LANE KOLKATA 57 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700057 | L3 | Rejected-Finance Higher Rate. | |
| 4 | Rejected-Technical VILL BORA P O MAMUDUPUR P S NAIHATI DIST 24 PARAGANAS NORTH PIN 743166 WEST BENGAL | NAIHATI | NORTH 24 PARGANAS | WEST BENGAL | 743166 | - | Rejected-Technical Required documents not submitted. | |
| 5 | Rejected-Technical | - | Rejected-Technical Required documents not submitted. |
Tender Value
Refer Docs
EMD Value
₹9,900
Closing Date
17 Jan 2025, 2:00 pmClosed
Assistant Engineer, PWD, KMCH Sub-Division.
33A Eden Hospital Road, Kolkata-700073
Periodical Maintenance for Fire Water Pumps and accessories (inside the Pump House) through comprehensive maintenance contract including inspection of hydrant network along with submission of Fire Safety Audit report of all buildings...Etc
2025_WBPWD_796062_1
WBPWD/AE/KMCHSD/NIQ-09e/24-25
Open Tender
Miscellaneous Services
Item Rate
365 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,900
Yes
30 Jun 2025
7 Jan 2025
20 Jan 2025
10 Jan 2025
17 Jan 2025
10 Jan 2025
Amount
Deputation of Skilled Manpower twice a month for intensive checking of all the pumps installed for fire fighting system including sequential operation of those pumps to check the performance of each pumps. The job includes checking of all valves and other instruments installed inside pump house and making necessary rectifications / repair / replacement to ensure proper functionality of the fire pumps. Storage of Diesel to be checked and refilling to be done whenever necessary to ensure smooth operation of Diesel Engine driven pump during emergency. Mock Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit in every 15 days and report of the test to be submitted to PWD for record. i) Pump House at the basement of 10 Storied Student Hostel building near Central reservoir----1No. ii) Pump room near Academic Building of MCH---1 No. iii) Pump room near Super Specialty Block---- 1 No
Inspection of hydrant network once in 3 months and submit report to PWD for any leakage or damage of hydrant / landing valves or any other type of valves and instruments for our further course of action to ensure proper functionality of the installed fire protection system. The scope also includes minor repair / rectification of all type of valves such as replacement of worn out or damaged gasket with new one, replacement of damaged bolts and nuts with new one etc. Major rectification such as replacement of damaged hand wheel, flanges, perforated pipes, pipe supports, valve seat rings etc. to be done on chargeable basis with prior intimation to PWD. During inspection of water network, the vendor shall drain out water from risers and recharge it with set pressure after proper flushing. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water. i) Hydrant network related to Pump House at the basement of 10 Storied Student Hostel building near Central reservoir----1No. ii) Hydrant network related to Pump room near Academic Building of MCH---1 No. iii) Hydrant network related to Pump room near Super Specialty Block---1 No
N P FIRE SAFETY SOLUTION AND CONSULTANCY (BID ID -6001922)
BISWAJIT PAUL (BID ID -6001986)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .