| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-Finance | L1 | Accepted-Finance Being Lowest Vendor | |
| 2 | L2₹32.7 L+₹1.2 L (3.81%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹33.0 L+₹1.6 L (5.05%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹34.2 L+₹2.7 L (8.67%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹36.1 L+₹4.6 L (14.6%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | M/s.Raghava Enterprises L5 | RAVITEJA ENGINEERING WORKS L6 | aswitha engineering works L3 | M/s SAI GANESH ENGINEERING ENTERPRISES L4 | GVR CONSTRUCTIONS L2 | SRI LAKSHMI ENGINEERING ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling taking out old GI pipe from PCC support/Trenches for replacement/ relaying of size 25 mm complete all as specified and directed. | 1,800 | RM | 100 ₹1,80,000 | 50 ₹90,000 | 60 ₹1,08,000 | 35 ₹63,000 | 28 ₹50,400 Lowest | 30 ₹54,000 |
| 2.00 | Supply, fixing and testing of 25 mm dia medium grade GI pipe including complete GI specials on PCC support or on trenches complete all as specified and directed | 1,500 | RM | 200 ₹3,00,000 | 450 ₹6,75,000 | 150 ₹2,25,000 Lowest | 450 ₹6,75,000 | 375 ₹5,62,500 | 375 ₹5,62,500 |
| 3.00 | M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 25 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed. | 300 | RM | 72 ₹21,600 | 150 ₹45,000 | 60 ₹18,000 | 75 ₹22,500 | 45 ₹13,500 Lowest | 80 ₹24,000 |
| 4.00 | Dismantling taking out old GI pipe from PCC support/Trenches for replacement/ relaying of size 40 mm complete all as specified and directed. | 840 | RM | 120 ₹1,00,800 | 55 ₹46,200 | 60 ₹50,400 | 40 ₹33,600 | 35 ₹29,400 | 25 ₹21,000 Lowest |
| 5.00 | Supply, fixing and testing of 40 mm dia medium grade GI pipe including complete GI specials on PCC support or on trenches complete all as specified and directed. | 720 | RM | 500 ₹3,60,000 | 655 ₹4,71,600 | 395 ₹2,84,400 Lowest | 475 ₹3,42,000 | 585 ₹4,21,200 | 550 ₹3,96,000 |
| 6.00 | M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 40 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed. | 120 | RM | 78 ₹9,360 | 155 ₹18,600 | 85 ₹10,200 | 75 ₹9,000 Lowest | 78 ₹9,360 | 90 ₹10,800 |
| 7.00 | Dismantling taking out old GI pipe from PCC support/Trenches for replacement/ relaying of size 50 mm complete all as specified and directed. | 980 | RM | 75 ₹73,500 | 90 ₹88,200 | 60 ₹58,800 | 45 ₹44,100 Lowest | 45 ₹44,100 Lowest | 60 ₹58,800 |
| 8.00 | Supply, fixing and testing of 50 mm dia Medium grade GI pipe including complete GI specials on PCC support or on trenches complete all as specified and directed. | 860 | RM | 324 ₹2,78,640 Lowest | 888 ₹7,63,680 | 412 ₹3,54,320 | 615 ₹5,28,900 | 765 ₹6,57,900 | 765 ₹6,57,900 |
| 9.00 | M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 50 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed. | 120 | RM | 84 ₹10,080 Lowest | 200 ₹24,000 | 85 ₹10,200 | 90 ₹10,800 | 106 ₹12,720 | 120 ₹14,400 |
| 10.00 | Excavation in trenches not exceeding 1.5m in depth and not exceeding 1.5m wide for pipe and getting out in soft/loose soil complete all as specified and directed. | 113.4 | CuM | 287 ₹32,545.8 | 410 ₹46,494 | 306 ₹34,700.4 | 225 ₹25,515 Lowest | 286 ₹32,432.4 | 400 ₹45,360 |
Tender Value
₹48.0 L
EMD Value
₹96,060
Closing Date
10 Oct 2025, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIR MAINTENANCE OF ARBORICULTURE PIPELINES SAFETY RELATED WORKS AND REPLACEMENT OF UNSV DISPLAY BOARDS DISTRIBUTION DIAGRAMS AND ALLIED WORKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE(I) DM VISAKHAPATNAM
2025_MES_730636_1
8359/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM VISAKHAPATNAM
₹96,060
Yes
1 Jan 2026
12 Sept 2025
13 Oct 2025
12 Sept 2025
10 Oct 2025
26 Sept 2025
Amount
Dismantling taking out old GI pipe from PCC support/Trenches for replacement/ relaying of size 25 mm complete all as specified and directed.
Supply, fixing and testing of 25 mm dia medium grade GI pipe including complete GI specials on PCC support or on trenches complete all as specified and directed
M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 25 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
Dismantling taking out old GI pipe from PCC support/Trenches for replacement/ relaying of size 40 mm complete all as specified and directed.
Supply, fixing and testing of 40 mm dia medium grade GI pipe including complete GI specials on PCC support or on trenches complete all as specified and directed.
M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 40 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
Dismantling taking out old GI pipe from PCC support/Trenches for replacement/ relaying of size 50 mm complete all as specified and directed.
Supply, fixing and testing of 50 mm dia Medium grade GI pipe including complete GI specials on PCC support or on trenches complete all as specified and directed.
M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 50 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
Excavation in trenches not exceeding 1.5m in depth and not exceeding 1.5m wide for pipe and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5M in depth and not exceeding 1.5M wide for cable/pipe and getting out in hard rock/Road/PCC hard standing and making the disturbed surfaces good same as existing before excavation complete all as specified and directed.
Returning, filling in(soil), including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated materials(soil) not exceeding 50M, depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
Labour only for attending break down of pipe line bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes etc as per site requirement, testing for leakages of testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed by engineer-in-charge for the bore of GI pipe upto 25mm. Note 1:- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable pump sets for dewatering at the time of breakdown. (ii) Necessary labour/trade men for attending break down and for fixing CI/DI/MS pipes, specials fittings (iii)GI pipes and specials will be measured and paid seperately under relevant items.Items which are not available as supply only are deemed to be included to make the unit completely functional Note 2 : The quoted rate is inclusie of identifying the leakage at the said area arresting the leakage and testing after arresting the leakage.
Labour only for attending break down of pipe line bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes etc as per site requirement, testing for leakages of testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed by engineer-in-charge for the bore of GI pipe upto 40/50mm. Note 1:- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable pump sets for dewatering at the time of breakdown. (ii) Necessary labour/trade men for attending break down and for fixing CI/DI/MS pipes, specials fittings (iii)GI pipes and specials will be measured and paid seperately under relevant items.Items which are not available as supply only are deemed to be included to make the unit completely functional Note 2 : The quoted rate is inclusie of identifying the leakage at the said area arresting the leakage and testing after arresting the leakage.
Supply only Gun metal gate valve of size 50mm including taking out old unserviceable one complete all as specified and directed.
Supply only Gun metal gate valve of size 40mm including taking out old unserviceable one complete all as specified and directed.
Supply only Ball valve of size 25mm including taking out old unserviceable one complete all as specified and directed.
Surface dressing of areas of above pipelines by clearing away all grass,wild vegetation,saplings,shrubs,brushwood,undergrowth,roots and tress not exceeding 30cm girth and removing rubbish upto a distance of 50mts outside the periphery of the area under clearance complete all as specified and as directed.
M&l for cleaning of existing valve chambers and applying two coats of white wash and applying synthetic enamel black paint on top cover after cleaning the debris and vegetation etc complete all as specified and directed.
Supply and fix acryllic LED name board as designed with radium glow lettering along with frame,base and structure support and internally wired for lighting waterproof for fixing at outdoor including plug and power adaptor and as per site complete all as specified and directed. Note:- The letters/design to be displayed will be approved by Engineer- in-Charge and prior approval to be taken
Supply and fix distribution diagrams of water supply along with frame,base and structure support and as per site complete all as specifiedand directed, Note:- The letters/design to be displayed will be approved by Engineer-in-Charge and prior approval to be taken
M&L for dismantling of foundation PCC, taking out from pump house, carryig to dumping yard inside ND (V) and necessary cleaning of work site all a specified and directed.
M&L for cement concrete type B1, (1:2:4) with 20mm graded agreegate in foundation, filling in and mass concrete all as specified and directed.
Supply only Heavy duty industrial high velocity air mover suitable for jetty galleries including mounting arrangements and duct alongwith extension box suitable complete all as specified and directed
M&L for valve chamber of internal size not less than 1200 x 1200 x 1200mm with cement brick palstering the surfaces with three coats of white w ashincl MS sheet cover of not less than 3mm thickness with MS angle not less than 40mmx40mmx5mm including proper locking arrangement and fabrication for air release valve painting with one coat of red oxide primer and one coats of anticorrosive black bituminous paint incl dismantling mild steel work of any description not otherwise specially provided for all as specified and directed.
GVR CONSTRUCTIONS (BID ID -3441481)
aswitha engineering works (BID ID -3447715)
M/s SAI GANESH ENGINEERING ENTERPRISES (BID ID -3441134)
M/s.Raghava Enterprises (BID ID -3440523)
RAVITEJA ENGINEERING WORKS (BID ID -3447234)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .