Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹15.6 L+₹74,132.75 (4.99%)Rejected-Finance | L2 | Rejected-Finance Due to L2 |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
16 Jul 2021, 6:00 pmClosed
GE AF BIDAR
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
PROVISION OF SHED AT BLDG NO PN-88, SENTRY POST NEAR LC- 47 UNDERPASS AND ANAND NAGAR GATE AND OTHER CERTAIN MINOR WORKS AT AFS BIDAR
2021_MES_452291_1
8286/E8
Open Tender
Civil Works
Item Rate
120 days
GE AF BIDAR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF BIDAR
₹33,000
Yes
9 Sept 2021
17 Jun 2021
17 Jul 2021
17 Jun 2021
16 Jul 2021
2 Jul 2021
Amount
Excavating in post holes (or similar holes) each n exc 0.5cum, getting out, returning, filling in layers not exceeding 25cm, removing excavated soil to a distance n.exc 50m and making good surface in Hard/dense soil.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, etc complete all as specified.
Steel work in tubular post, trusses, including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St -240.
Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick, coloured, of having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
Preparation of new steel and iron surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer.
Preparation of new steel and iron surfaces of any description, n. exe 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil, all as specified and directed.
Pre-cast cement concrete block masonry with solid blocks type C1 1:3:6 (20 mm graded stone aggregate), exc. 10cm in width and setting in CM (1:6), complete all as specified and directed.
Returning filling, incl spreading, levelling, watering & well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m & depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Rendering 15 mm thick on fair faces of concrete wall surfaces in CM (1:6), finishing the surface even and smooth without using extra cement complete all as specified and directed
Rendering 15 mm thick cement plaster, [5mm thick setting coat mixed with water proofing compound in CM (1:4) over 10mm thick plaster in CM(1:6)] in two layers, finishing the surface even and smooth without using extra cement all as specified and directed. Note: supply only water proofing compound shall be measured and paid separately.
Supply only integral water water proofing compound.
Rendering 5 mm thick on fair faces of concrete ceiling surfaces in CM 1:3, finishing the surface even and smooth without using extra cement all as specified and directed.
Hardcore with broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface,all as specified and directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) 100 mm thick as in sub base complete all as specified and directed.
Plain cement concrete 1:2:4 type B1, (20mm graded stone aggregate) 55mm thick as in floors, finishing the surface even and smooth without using extra cement all as specified and directed.
Plain cement concrete 75 mm thick 1:3:6 type C2 (40mm graded stone aggregate) as in plinth protection all as specified and directed.
Forming contraction (Dummy) joints 65 mm deep and 10 mm wide, filled with sealing compound grade A all as directed by Engineer in charge.
Preparation of new plastered ceilng surfaces and applying three coats of white washing all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over 1mm thick wall care putty on plastered surface for neat and smooth finishing complete. all as specified.
Applying two coats of cement base paint over a coat of alkali resistant primer on new plastered surfaces of walls including preparation etc all as specified and directed.
Form work for soffits of slabs rough finished surfaces, all as specified and directed.
Formwork to edges of concrete roofs n exc 20 cm wide all as specified and directed.
Reinforcement for concrete with mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified and directed.
Reinforcement for concrete with mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified and directed.
Formwork to sides and soffits of floor or roof beams, rough finished surfaces all as specified and directed.
Reinforced cement concrete type B1, 1:2:4 (20 mm graded stone aggregate) as in slab, roof beams etc,all as specified and directed.
Cutting holes in stone walls built in cement mortar depth exc half brick but not exc one brick for inserting hold fast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type -B-1 as required.
Providing, cement concrete Type B-0 1:2:4 using 12.5mm graded stone aggregate as in coping, bed plates, kerbs as required at site, including form work, rounded or chamfered on edges complete.
Mild steel Framed work as in doors/windows or gates or ladder of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, Doors, etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging doors fittings (exclusive of steel sheeting or other covering, running rails and guides ) and hanging; also fastening and fixing complete.Fe-410-W (Gde-E-250 quality- B.
Point wiring complete with 2 runs of 1.5 sqmm single core, PVC insulated, unsheathed cable 1100 volts grade, multi stranded copper conductor drawn into and including suitable size of PVC conduit and accessories concealed in wall, roof etc., and including provision of one run of PVC insulated 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6mm thick MS sheet concealed in wall and laminated sheet cover of 3mm thick on top for housing the switches, fan regulator, socket, outlets etc complete for one light point controlled by one switch 5 Amp complete all as specified and as directed.
All as per item No.32 here-in-before but for one fan point controlled by one switch.
All as per item No.32 here-in-before but for one 5Amps socket controlled by one switch on same board
Switch piano, flush type single pole, one way 5 Amp complete all as specified and as directed
Ceiling rose, 3 phase, PVC/ polycarbonate, isolated body all as specified and as directed
Switch socket combination 2 in 1, 3 pin 5 amps and 230 volts flush type universal complete all as specified and as directed
Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable, 1100 volts grade, multistranded copper conductor drawn through and including suitable size of PVC conduit pipe and accessories concealed to surface /wall roof etc with one run PVC insulated 6sqmm FRLS cable, copper condutor for earth continuity conductor all as specified and as directed (for DBs). Note: 2 runs 4sqmm single core copper conductor, one run of 4sqmm copper conductor earth wire and PVC conduit with accessories will be measured as one unit.
MCB DB SPN 8 way metallic double door IP42 Protection 240V, AC 50Hz for MCB double pole as incomer and double pole/ single pole MCB as outgoing with tinned copper bus bar of rated 200 Amps neutral link earth link complete.
MCB SPN 63 Amp 240 V 50Hz, 10KA C series including making electrical connection with the help of Lugs/thimbles all as specified and as directed.
MCB SP 6- 32 Amps 240 V 50Hz, 10KA C series including making electrical connection with the help of Lugs/ thimbles all as specified and as directed.
Supply, Fixing and testing of LED surface 22W LED luminaires, 10 Watts, with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparallelleled light distribution high optically efficient serrated diffuser, Isolated Multi stage CCCV driver with voltage range 150-270V AC, temperature range- 0 to 50 Deg C, CRI >80, class-1, SDCM <5, Driver efficiency>85%, Power factor >0.95, THD<10%, Colour temperature-6500K, short circuit and over circuit protection, Surge protection- 3KV in CM, Safety Extra Low Voltage Safe level<60V DC as per IS-10322/IEC-60598 standard, IP20 protected, 25000 burning hours, with 70% of its initial lumen maintained, Lumianire efficacy>100lm/W fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 Sqmm copper conductor for connection complete all as specified and directed.
Wall mounted fan, non-metallic body, of size 400mm elegantly designed fan base in round shape and pull cord control for speed and oscillation, all as specified and as directed.
LED Luminaire IP65 35 W Aesthetically designed LED gate light with aluminium enclosure, powered with high power LEDs as light source and die casted heat sink exhibits classic look with symmetrical light distribution and excellent heat dissipation for long life. powe factor >0.95 ,luminaire lumen output -6440 lm, CCCV driver with voltage range 150- 270 v AC , temperature range -10° C to + 50° C ,CRI >80,cass -1, SDCM<5,driver efficiency >85 %,power factor >0.95,THD <10 % ,color htemperature -6500 K, short circuit and over circuit protection , surge protection -3 KV in CM, safety extra low voltage safe level <60 V DC as per IS-10322/IEC-60598 standard IP 20 protected, 50000 burning hours with 70% of its initial lumen maintained luminaire effeciency > 100 lm/W fixed complete with all accessories and provision of PVC sheathed 3 core 1.5 sqmm copper conductor for connection complete all as specified and as directed.
LT XLPE insulated, PVC flat twin two core electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm,connecting to the DB, with supporting wire, fixed on wall / pole / surface complete all as specified and as directed .
Sub main wiring complete with 2 runs of 6 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor cable with one run of 6.0 Sqmm single core PVC insulated FRLS cable 1100 Volts grade, multistranded copper conductor cable as earth continuity conductor drawn through and including suitable size medium grade PVC conduit pipe and accessories concealed in surface / walls / floors / ceilings / roofs etc., including cutting grooves chases and finishing up matching with existing surface all as specified and as directed. Note: Two runs of 6 Sqmm copper conductor, One run of 6.0 Sqmm copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts (for AC) complete all as specified and as directed.
Supply, install, connect, test and commissioning of inverter type Air conditioner Hi wall comprising of units Indoor & outdoor complete with cordless remote control unit, within built in air ioniser, Plasma filter for better indoor air quality, leakage detector etc with minimum 5 star rating and EER 3.2 of capacity 2.0 TR, inclusive of suction and discharge lines of suitable size and length of copper tube, necessary brazing and providing nitrile tubing over gas circulating copper tubes and neatly tying the ends with PVC insulating tape and mounting on suitable bracket, suitable drain pipe for disposal of waste water upto ground level and testing, neatly finishing the disturbed surfaces of walls to match with the surroundings complete all as directed.
All as per item No 49 here in before but 2.0 Ton capacity
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil, all as specified and directed.
Unreinforced pre cast concrete cable cover class LV type 1 flat size 250 x 150 x40 mm for cable protection all as directed.
River sand for cushioning of underground cable filling, spreading and levelling in trenches or cable ducts all as directed. Note: Only punned thickness of sand shall be measured for payment purpose
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 2 core laid in duct / trench / wall surface all as directed.
Plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation, filling, etc complete all as specified.
Providing, cement concrete Type B-1, 1:2:4 using 20mm graded stone aggregate as in coping, including form work and finishing exposed surface even & smooth without using extra cement complete all as directed.
Sub main wiring complete with 2 runs of 4 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor cable with one run of 4 Sqmm single core PVC insulated FRLS cable 1100 Volts grade, multistranded copper conductor cable as earth continuity conductor drawn through and including suitable size steel conduit pipe and accessories on surface of walls / roofs etc., all as specified and as directed. NOTE:- Two runs of 4 Sqmm copper conductor, One run of 4.0 Sqmm copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
GI pipe 80mm dia light grade laid in trenches for cable protection all as specified and as directed.
MCB SPN 32 Amp 240 V 50Hz, 10KA C series including making electrical connection with the help of Lugs/thimbles, all as specified and as directed.
70 W high efficient LED flood light, aluminium die cast housing parts for long life, pure polyster powder coated dark grey housing, high purity PMMA lenses for superior performance, toughened glass with silicon gaskets for IP 65 protection, driver cover designed suitable power factor >0.95, luminaire lumen output -6440 lm, CCCV driver with voltage range 150- 270 v AC, temperature range 0 to 50 Deg C, CRI >80,cass -1, SDCM<5, driver efficiency >85 %, power factor >0.95, THD <10 % , colour temperature -6000 K, short circuit and over circuit protection, surge protection -3 KV in CM, safety extra low voltage safe levcel <60 V DC as per IS-10322/IEC-60598 standard IP65 protected, 50000 burning hours with 70 % of its initial lumen maintained luminaire effeciency > 100 lm/W fixed complete with all accesoories and provision of PVC sheathed 3 core 1.5 sqmm copper conductor for connection complete all as specified and as directed.
Supply and fixing enclosed MS terminal box of size 120 mm x 120 mm x 80 mm with proper cover/ door with screw arrangements on two corners duly painted with single coat of synthetic enamel paint over a coat of red oxide primer, fixed on GI post of post top lamp fitting with suitable GI clamp, nuts, bolts, etc and provision for fixing of MCB single pole on insulators and connecting incoming and outgoing cables all as directed at site. Note: Items like MCB / isolators will be measured and paid separately.
m/s raghavendra kulkarni
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .