Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹50.5 L+₹68,640.95 (1.38%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹50.9 L+₹1.1 L (2.20%)Rejected-AOC OPP KIRYAPA PARK NATIONAL HIGHWAY ROAD BARAMULLA J K 193101 | NA | NA | 193101 | L3 | Rejected-AOC OTHER THAN LOWEST | |
| 4 | L4₹51.2 L+₹1.4 L (2.90%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST | |
| 5 | L5₹53.1 L+₹3.3 L (6.59%)Rejected-AOC YADIPORA PHALHALLAN TEH PATTAN DISTT BARAMULLA J K | PATTAN | BARAMULLA | JAMMU AND KASHMIR | 193121 | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹45.4 L
EMD Value
₹90,880
Closing Date
18 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS C/O 56 APO
GE 969 EWS C/O 56 APO
SPL REPAIR TO CERTAIN BLDGS AND MINOR WORK AT BARAMULLA UNDER GE 969 EWS
2024_MES_672602_2
CA NO 969 WS - /2024-25
Open Tender
Civil Works
Item Rate
180 days
BARAMULLA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹90,880
Yes
16 Jan 2025
5 Nov 2024
25 Nov 2024
5 Nov 2024
18 Nov 2024
12 Nov 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.
(a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way
(b) One 3 pin 5 Amp switch socket outlet on independent board
(c) One 3 pin 5 Amp switch socket outlet on same board with accessories
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor.
S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed.
S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type with gang box, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type with gang box,complete all as specified and as directed.
Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body.
S&F Distribution board, SPN 8 way, Double door complete all as specified and as directed.
S&F Distribution board, SPN 4 way, Double door complete all as specified and as directed.
S&F in repairs MCB,DP 40 Amps 240 Volts B curve, complete all as specified and as directed.
S&F in repairs MCB, SP 6-32 Amps 240 Volts B curve, complete all as specified and as directed.
S&F LED fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose all as specified and as directed.
S&F LED light fitting 1x10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED Bulb 12W, 220 V suitable size from ceiling rose, complete all as specified and as directed.
S&F in repairs lamp Holder, PVC/Polycarbonate type with black plate suitable for batten fitting complete all as specified and as directed.
S&F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F in repair capacitor 1.5/2 mfd suitable for 1200mm sweep ceiling fan complete all as specified and as directed.
M&L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 6 Sqmm and one run of 6 Sqmm cable and one run of casing capping shall be measured as one RM
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core, complete all as specified and as directed.
Taking down & dismantling the ceiling fan from site and removing its allied smaller parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, split pins, screws, nuts and spring washers complete including, flexible chord of 24/ 0.20mm with neccessary connector (for blade/ body) as required after rewinding complete all as specified and as directed. Note : Spares used and rewinding shall be measured and paid separately under relevant item.
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal etc
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling of timber scantling 40 Sqcm and over in section in any position in unframed work, complete all as specified and as directed.
S&F 2nd class softwood in scantling clean swan timber framed and fixed to the position, complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description and applying two coats of synthetic enamel paint over a coat of zinc chrom primer not otherwise described, over 10cm width or girth, complete all as specified and as directed.
Dismantling wall and ceilling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness, cover fillets etc complete all as specified and as directed.
M&L 4 mm thick veneered decoretive, Plywood grade 1 (BWR resin) with decoretive face veneers on one faces , fixed with nails to timber frame work on ceiling, complete all as specified and as directed.
M&L 4 mm thick veneered decoretive, Plywood grade 1 (BWR resin) with decoretive face veneers on one faces , fixed with nails to timber frame work on wall, complete all as specified and as directed.
Dismantling timber in fillets, rails,posts rafters,purlins etc under 40 sqcm in section unframed work, complete all as specified and as directed.
M&L for plain fillets square rectangular or triangular in section using 2nd class soft wood clean sawn secured with nails exc 13 Sqcm but n. exc 25 sqcm in section complete all as specified and as directed.
M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean sawn secured with nails not exc 3 Sqcm in section, complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed.
S&F Softwood 2nd class clean sawn with butt joints eaves boards 20 mm thick, complete all as specified and as directed.
M&L Weather boarding, 25 mm thick, wrought both sides, V-jointed to give 20mm laps and fixed, complete all as specified and as directed.
Taking down chowkats or frames but with shutters (without taking off shutters from the frame) n. exc 1.5 Sqm complete all as specified and as directed.
Taking down chowkats or frames but with shutters (without taking off shutters from the frame) exc 1.5 Sqm and n.exc 4.00 sqm complete all as specified and as directed.
S&F 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
S&F Glazed and skeleton shutters thickness 30 mm,(2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Sectionspecified 8 clause 8.24(b) complete all as specified and as directed.
S&F Glazed and skeleton shutters thickness 35 mm,(2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Sectionspecified 8 clause 8.24(a) complete all as specified and as directed.
S&F Sheet glass thickness 3.00 mm,ordinary quality and glazing with oil putty in square exceed 0.5 sqm in each pane complete all as specified and as directed.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
Aluminium anodised, barrel tower bolts 100 mm of extruded section and fixed, complete all as specified and as directed.
Aluminium anodised, barrel tower bolts 200 mm of extruded section and fixed, complete all as specified and as directed.
Aluminium alloy, anodised, sliding door bolt 200 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed.
M S Butt hinges 100 mm medium weight, cold rolled mild steel, complete all as specified and as directed.
M S Butt hinges 75 mm medium weight, cold rolled mild steel, complete all as specified and as directed.
Aluminium handles 100 mm , cast type, anodised complete all as specified and as directed.
Aluminium handles 150 mm , cast type, anodised complete all as specified and as directed.
S&F of Harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc
Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below & above GL) unreinforced complete all as specified and as directed.
M&L 75 mm thickness Cement concrete type D2, 1:4:8 (40mm graded aggregate) as in flooring, complete all as specified and as directed.
M&L 25 mm thickness Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring, complete all as specified and as directed.
M&L machine cut Kota stone slab flooring 20-25mm thick over 15 mm thick cement screed base in CM 1:4 ,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, and polishing, complete all as specified and as directed.
M&L 75mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, complete all as specified and as directed.
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 35 Sqmm 3.5 core,complete all as per specified and as directed.
S&F ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100A complete all as specified and as directed.
S&F ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63A complete all as specified and as directed.
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH front side) out door type, CPRI approved both side opened, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
(a) INCOMING
(i) Four pole MCCB 200 Amp, 50 Hz 415 Volts with repturing capacity 36 KA 2 Nos
(ii) Indicator LED lamp R,Y,B 1 No
(iv) Digital voltmeter 0-400 Amps with suitable CT's 1 No
(v) Internal Panel wiring of suitable size of copper conductor not less than 1.5 Sqmm 1 No
(b) OUTGOING
(i) Four pole MCCB 125 Amp, 50 Hz 415 Volts with repturing capacity 25 KA.
(ii) Four pole MCCB 63 Amp, 50 Hz 415 Volts with repturing capacity 25 KA.
(iii) Outgoing MCB DP 10 to 32 Amp
Dismantling old and unsv steel tublar poles of any type including breaking cement concrete complete and site clearance .
Dismantling of cross arms of MS channel or angle sections etc complete all as specified and directed.
Dismantling HT/LT OH line from the insulators complete all as specified and directed.
Dismantling and taking down the existing LT/HT insulators of any type from any description
Dismantling & Taking out the existing old service cables off sizes, complete all as specified and directed.
Dismantling old UNSV existing LT panel with switch gears, complete all as specified and directed.
Dismantling & Taking out old UNSV earthing, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 2 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes as in repairs :-
(a) 50 mm dia
(b) 80 mm dia
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 400 Amps rating and 36 KA rupturing capacity - 01 No
(iv) CTs ratio 400/5A class ISI marked sets of three each
(v) Indicating lamp-01 set of three
(b) OUTGOING
(i) MCCB 4 Pole, 415 volts grade 250 Amps rating and 25 KA rupturing capacity -02 Nos
(ii) MCCB 4 Pole, 415 volts grade 160 Amps rating and 36 KA rupturing capacity -02 Nos
(iii) MCCB 4 Pole, 415 volts grade 100 Amps rating and 25 KA rupturing capacity -02 Nos
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 250 Amps rating and 35 KA rupturing capacity - 01 No
(iv) CTs ratio 100/5A class ISI marked sets of three each
(v) Indicating lamp-01 set of three
(b) OUTGOING
(i) MCCB 4 Pole, 415 volts grade 250 Amps rating and 36 KA rupturing capacity -01 Nos
(ii) MCCB 4 Pole, 415 volts grade 160 Amps rating and 36 KA rupturing capacity -01 Nos
(iii) MCB DP, 415 volts grade 32 Amps - 06 Nos
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH Back side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 160 Amps rating and 25 KA rupturing capacity - 01 No
(iv) CTs ratio 160/5A class ISI marked sets of three each
(v) Indicating lamp-01 set of three
(b) OUTGOING
(i) MCCB 4 Pole, 415 volts grade 160 Amps rating and 36 KA rupturing capacity -01 Nos
(ii) MCCB TPN , 415 volts grade 63 Amps rating and 36 KA rupturing capacity -01 Nos
(iii) MCB DP, 415 volts grade 63 Amps - 03 Nos
(iv) MCB DP, 415 volts grade 32 Amps - 04 Nos
(v) MCB DP, 415 volts grade 20 Amps - 01 Nos
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Adm Block) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-
(a) INCOMING
(i) MCCB 4 Pole 415 volts grade 160 Amps rating and 25 KA rupturing capacity - 01 No
(iv) CTs ratio 160/5A class ISI marked sets of three each
(v) Indicating lamp-01 set of three
(b) OUTGOING
(i) MCCB 4 Pole, 415 volts grade 160 Amps rating and 36 KA rupturing capacity -01 Nos
(ii) MCCB TPN , 415 volts grade 100 Amps rating and 36 KA rupturing capacity -01 Nos
(iii) MCB DP, 415 volts grade 63 Amps - 07 Nos
(iv) MCB DP, 415 volts grade 32 Amps - 03 Nos
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick buried directly in to the ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth strip 32 x 6 mm by means of bolts, nuts thimble check nuts and washers of galvanised iron or steel using GI including PCC (concrete chamber) 1:3:6 Type C-1 using 20 mm graded stone aggregate with fair finish of internal surface concrete, 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68 mm) 8 mesh per inner inch, 80mm thick RCC Pit cover 320mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM and charcole dust and common salt all as shown in electrical plate No-3 MES SSR Part-I and specified including provision of earth wire/ strip protected by 40 mm dia medium grade GI pipe including all excavation and earth work & connecting the earth earthing to an earthing test point/ transformer neutral/ body LT panel etc and testing on complete, complete all as specified and directed Note :- Quoted rate of earthing shall be deemed to included cost of 7.5 M long galvanised iron strip 32X6 mm and protection pipe of 40mm bore medium grade, GI light grade 20mm bore watering pipe.
Supply and fixing RCC cable route marker for LT complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth,for foundations,laying of pipes/cables etc not exceeding 10sqm on plan for mamholes etc and not exceeding 1.5 metre in depth and getting out in Soft/loose soil, complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm.in hard/dense soil, complete all as specified and as directed.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed.
Supply and laying of burnt clay building bricks, sub-class B (old size) Designation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and directed.
M & L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 Note:-Sand shall be fine sand as specified for plastering.
Supply and installation Voltage stabilizer Copper Wound for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 V to 460 V with output voltage stabilizer at 415 with accuracy ± 2.5% and speed of correction 8 volts per second and of capacity 100 KVA, complete all as specified and as directed.
Note:- Schedule of credit Rs 1,00,636.70 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S KULWANT SINGH RAINA AND CO (BID ID -3166380)
M/S GHULAM RASOOL LONE (BID ID -3166455)
M/s SONA ULLAH LONE AND SONS (BID ID -3166496)
M/S MANZOOR AHMAD YATOO (BID ID -3168609)
DUKE CONSTRUCTION (BID ID -3168351)
M/S LONE BUILDERS AND SUPPLIERS (BID ID -3168448)
M/S ALTAF HUSSAIN KHUROO (BID ID -3168308)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .