Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹77.0 L+₹2.3 L (3.02%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹78.1 L+₹3.4 L (4.50%)Admitted-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L3 | Admitted-Finance | |
| 4 | L4₹78.4 L+₹3.7 L (4.89%)Admitted-Finance FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L4 | Admitted-Finance | |
| 5 | L5₹1.6 Cr+₹83.5 L (111.7%)Admitted-Finance 49 53 7 13 1ST FLOOR SAMPADA GALAXY BS LAYOUT NEAR 4TH TOWN POLICE STATION VISAKHAPATNAM ANDHRA PRADESH 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MSN ENGINEERING WORKS L3 | Power Dynamics L1 | Power engineering Associates L5 | MURALI KRISHNA ASSOCIATES L4 | SAI SREENIVASA ENGINEERING L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft loose soil for cable work or from above cable duct complete all as specified and directed. | 550 | CuM | 350 ₹1,92,500 | 350 ₹1,92,500 | 573 ₹3,15,150 | 270 ₹1,48,500 Lowest | 293 ₹1,61,150 |
| 2.00 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft disintegrated rock (considered for road cutting) complete all as specified and directed. | 109 | CuM | 400 ₹43,600 | 500 ₹54,500 | 796 ₹86,764 | 360 ₹39,240 Lowest | 600 ₹65,400 |
| 3.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick all as specified and directed. | 618 | CuM | 125 ₹77,250 | 100 ₹61,800 | 175 ₹1,08,150 | 72 ₹44,496 | 65 ₹40,170 Lowest |
| 4.00 | Removing of excavated material not exc 50M and depositing where directed at a level not exc 1.5M above the starting point all as specified and directed. | 41 | CuM | 100 ₹4,100 | 200 ₹8,200 | 160 ₹6,560 | 180 ₹7,380 | 79 ₹3,239 Lowest |
| 5.00 | M&L for dry sand cushioning for under ground cable provided with layer and sand 8 cm deep before laying the cable and 15cm after laying the cable complete all as specified and directed. | 138.8 | CuM | 950 ₹1,31,860 | 500 ₹69,400 Lowest | 2,390 ₹3,31,732 | 999 ₹1,38,661.2 | 1,309 ₹1,81,689.2 |
| 6.00 | Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mm x 180mm x 40mm all as specified and directed. | 9,755 | Each | 32 ₹3,12,160 Lowest | 40 ₹3,90,200 | 165 ₹16,09,575 | 36 ₹3,51,180 | 36 ₹3,51,180 |
| 7.00 | Supply, Installing, Testing & Commissioning of 3 way RMU (1 incoming + 2 outgoing), 12KV, 630 Amps outdoor, extensible type, SF6 insulated, consisting of 01 No. 630 Amps VCB, fixed, non draw out type as incoming and 02 Nos. 630 Amps VCB as outgoing complete all aw specified and as directed comprising of the following :- | 1 | Each Job | 15,24,900 ₹15,24,900 Lowest | 15,45,000 ₹15,45,000 | 18,55,845 ₹18,55,845 | 15,30,000 ₹15,30,000 | 15,41,500 ₹15,41,500 |
| 7.01(a) RMU shall be floor mounted, 12KV, 630 Amps, 21 KA for 3 seconds, SF6 insulated, motorized, outdoor extensible type RMU with air insulated bus connected metering unit, feeder remote terminal unit & load break switch, type tested in line with latest IEC standards, suitable for operational a height upto 1000M above sea level and Ambient Temperature range from 5°C to 50°C without any de-rating, switchgear and busbar shall be contained in a stainless steel enclosure (Minimum 2.0mm thick SS 304 Grade) filled with SF6 at 0.3 to 0.4 Bar relative pressure, RMU tank shall provide full insulation and switchgear shall be insensitive to the environment with degree of protection of IP 67, switchgear operating mechansim shall as IP2X protection and cable chamber shall have IP3x protection, outer enclosure shall be IP 54 type tested, powder costed with pure polyster based paint, suitable for the site installation condition, accidental overpressure due to and internal Arc is limited by the opening of the safety valve at the bottom of the metal enclosure, away from the operation, plug in type of extensinsibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle shall require 450mm to handle and the gap between the coupled RMU's must be within 10mm. | ||||||||
| 7.02(b) Each Vacuum circuit breaker (VCB) shall be comprising of the following :- (i) 11KV, 630 Amps, 21 KA/3s, 3 pole motorized VCB (Non draw out type) with 3 pole manual disconnector and 3 pole manual earth switch, motorized spring assisted mechanism and series Trip coil. (ii) Self powered relay with O/C, S/C, E/F protection, relay shall have a front USB for laptop interface, LCD display, 10 event Records, 5 fault Records, min 2 setting group and keypad for setting parameters for the relay with zero time delay (DT) for I >>, I>>>, IO>>, IO >>> setting groups. (iii) Resin cast ring core protection CT, plate mounted type of suitable ratings. (iv) Live cable indicator with indications at the front and three inlets to check the synchronization of phases. (v) Cable termination bushing suitable for upto 1 Run, 3 core, 240 Sqmm, XLPE cable. (vi) Cable termination cover boots (Push on type) (vii) Circuit breakers shall have two positions : Open or Disconnected and closed. A separate and Independent 3 position earthing switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorized operations. An operating mechansim shall be used to manually close the circuit breaker and cange the mechanism in a single movement. An Independent mechanism shall be fitted for the 3 positions earthing switch and disconnector circuit breaker shall be fitted with a local system for manual tripping by an Ingegrated Push Button. There shall be no automatic reclosing. Circuit breaker shall have a min of 2000 Mechanical and Electrical Operations. | ||||||||
| 7.03(C) Air insulated Bus connected Metering unit comprising the following :- (i) Air insulated enclosure with necessary bus connection. (ii) PT 11KV/ √3/110V/√3, 50VA, Class - 1.0 (iii) Multi Functionmeter, Digital type (Displaying A, V, PF, Hz, KVA, KW, KVAR, KWH, KVAR etc., Class 1.0/0.5) with RS 485 port for communication in Modbus protocol. (iv) R/Y/B indicating lamps (v) 11 KV/230V AC, Class 1, 500 VA control Transformer. (vi) Battery and Battery charger, 12 Ah, (I/P-230V AC, O/P - 24V DC. | ||||||||
Tender Value
₹80.1 L
EMD Value
₹1.5 L
Closing Date
9 Sept 2026, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
PROVISION OF RING MAIN UNIT AT CDS II PROVISION OF STANDBY 11 KV HT SUPPLY FOR N13 JETTY SUBSTATION AND PROVISION OF WATER COOLER AND CONNECTED ACCESSORIES SUPPLY JOINTS AT JETTY WATER POINTS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) DM VISAKHAPA
2026_MES_782876_1
8554/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹1,000
GE (I) DM Visakhapatnam
₹1.5 L
Yes
16 Sept 2026
5 Aug 2026
11 Sept 2026
5 Aug 2026
9 Sept 2026
26 Aug 2026
6 Aug 2026 - 24 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft loose soil for cable work or from above cable duct complete all as specified and directed. | 550 | CuM | - | - |
| 2 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft disintegrated rock (considered for road cutting) complete all as specified and directed. | 109 | CuM | - | - |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick all as specified and directed. | 618 | CuM | - | - |
| 4 | Removing of excavated material not exc 50M and depositing where directed at a level not exc 1.5M above the starting point all as specified and directed. | 41 | CuM | - | - |
| 5 | M&L for dry sand cushioning for under ground cable provided with layer and sand 8 cm deep before laying the cable and 15cm after laying the cable complete all as specified and directed. | 138.8 | CuM | - | - |
| 6 | Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mm x 180mm x 40mm all as specified and directed. | 9,755 | Each | - | - |
| 7 | Supply Install testing and commisioning of RMU(Ring Main Unit) 11KV with one incomer of capacity 630 Amps VCB and two outgoing of 630 Amps VCB each metering instruments, Feeder Remote Terminal Unit & load break switch including necessary civil works for fixing of RMU all as specified and as directed. | 1 | Each Job | - | - |
| 8 | S/L in trenches or in duct or passing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, overall PVC sheathed electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (Earthed) cross sectional area 240 sq. mm 3 core incl dismantling / taking down unserviceable one complete all as specified and directed. | 1,760 | RM | - | - |
| 9 | S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm incl dismantling / taking down unserviceable one complete all as specified and directed. | 3 | Each | - | - |
| 10 | S&F Cable jointing kit for 11 KV (Earthed) grade cable for Striaght through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm incl dismantling / taking down unserviceable one all as specified and directed. | 3 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_877112.xls
BOQ • 0.25 MB
8554Tender.pdf
Tender Documents • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .