Loading…
Loading…
Tender Value
₹34.0 L
EMD Value
₹34,000
Closing Date
21 Sept 2026, 12:01 pmClosed
EXECUTIVE ENGINEER, ELECTRICAL (R&B) DIVISION, GODHARA
Providing and Erecting E.I. and Street Lights on Zalod-Ahmedabad Highway Road ( From Guest House to Manav Restaurant ) At Balasinor, Ta. Balasinor, Dist. Mahisagar
342791
E Tender TC-04-04 of 2026-27
Open
Electrical
Works
Panchmahal
8 documents required · 8 mandatory
₹1,500
EXECUTIVE ENGINEER, ELECTRICAL (R&B) DIVISION, GODHRA
₹34,000
9 Sept 2026
9 Sept 2026
9 Sept 2026
21 Sept 2026
9 Sept 2026
Name of Work :- Providing and Erecting E.I. and Street Lights on Zalod-Ahmedabad Highway Road ( From Guest House to Manav
Restaurant ) At Balasinor, Ta. Balasinor, Dist. Mahisagar
QTY. UNIT RATE IN WORDS TOTAL
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for Rupees Seventy Paise
control panel, relays, power switchgears, motor starters & control wiring) with Seventy Only
required size of copper lugs, nuts and bolts if required.(e) One wire 6.00 sq. mm
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv
grade ISI marked copper wires of following size to be erected as directed.(h) 2.50 Rupees Ninety Seven
Sq.mm 3 core round PVC sheathed (Make:Havells,KEI,finolex,RRkable, Apar, Paise Ninety Seven Only
Supplying and erecting LED street light / Flood light fittings with High power
White LEDs wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass
with company mark/name engraved or embossed 160 to 270 V,Power Factor
more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings Rupees Five Thousand
3a required LM-79 & LM-80 certificates)(NOTE: Below description have shown 68.00 Ea. 5581.26 Five hundred Eighty One
ranges of Wattage capacity of LED fittings.The Engineer incharge may select any Paise Twenty Six Only
wattage capacity between the ranges shown.) (A) Street Light (IP-65), Surge
protection -4KV integral and ,Light must have 440VAC line supply with over-
voltage protection. (iv) 90 - 119 watts Cat-lll (Make: Philips , Crompton,
Wipro,Jaguar, Havells) Fittings should be NABL tested and certified.
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have
Rupees Eight Thousand
440VAC line supply with over-voltage protection.(vi) 160 - 199 watts Cat-lll
3b 6.00 Ea. 8201.20 Two hundred One Paise
(Make: Philips , Crompton, Wipro,Jaguar, Havells) Fittings should be NABL
tested and certified.
Providing and erecting Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up
to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. Rupees Six Thousand
4a supply 50 c/s. with all internal connections, spreader tinned copper & complete 1.00 Ea. 6790.23 Seven hundred Ninety
erected in existing 16 G.M.S. housing.ICS=100% of ICU only Cat III Paise Twenty Three Only
(Make:L&T,havells,Hager,C&S, Siemens)
Add Rs. 10% extra for housing/Encloser of MCCB
Rupees Seven Thousand
(Make:L&T,havells,Hager,C&S, Siemens)
4b 1.00 Ea. 7469.25 Four hundred Sixty Nine
Paise Twenty Five Only
Providing and erecting Approved make Earth fault Relay suitable to mount with
inter connection suitable to following size of moulded case circuit breaker having Rupees Five Thousand
5 CT ratio & MCCB rating as following along with shunt trip 220V AC. with all 1.00 Ea 5156.05 One hundred Fifty Six
internal connections & complete erected in existing M.S.housing.. (1) 15 A -100 Paise Five Only
A , CT Ratio 1/100
providing and erecting Miniature circuit breaker single pole 0.5A to 2A system
Rupees Two hundred
and having breaking capacity 10 KA to be erected in existing box. confirming to
6 68.00 Ea 297.95 Ninety Seven Paise Ninety
IS 8828/1996 with ISI Mark Cat III (Make:L&T,havells,Hager,C&S, Siemens)
Providing and erecting Annealed bare Copper wire 8 to 16 SWG. Rupees Seven hundred
7 2.00 Kg 794.87 Ninety Four Paise Eighty
Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia. Rupees Three hundred
8 galvanised iron pipe with coupling and buch buried in specially prepared earth pit 68.00 Ea. 368.65 Sixty Eight Paise Sixty
complete with necessary 8 SWG earth wire. Five Only
For using salt and charcoal / coke as required for pipe type earthing. Rupees One hundred
9 68.00 Ea 171.70 Seventy One Paise
QTY. UNIT RATE IN WORDS TOTAL
Supplying & erecting earth pit of minimum bore dia.150mm size approved make
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm
having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm with constant ohmic value
surrounded by highly conductive compound with high charge dissipation suitable
for following type of applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by agency and officer Incharge Rupees Four Thousand
10 has to ensure the value of earthing resistane mentioned in test Certificate) & 2.00 Ea 4591.46 Five hundred Ninety One
having back filling compound of (B) Inner chemical (CCM Compound)- Paise Forty Six Only
Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :-
Earthing compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency. (a) For Electrical Installation
up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand /
Solid Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps Rupees One hundred Sixty
11 or in existing trench / pipe of following size of cables (C) 4 core 10 Sq. mm 40.00 Mtr. 168.67 Eight Paise Sixty Seven
(Make:Havells,KEI,finolex,RRkable, Apar, polycab) Only
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in Rupees Two hundred
12a existing trench / pipe of following size of cables (B) 4 core 25 Sq. mm 2150.00 Mtr. 229.27 Twenty Nine Paise Twenty
(Make:Havells,KEI,finolex,RRkable, Apar, polycab) Seven Only
(C) 4 core 35 Sq. mm (Make:Havells,KEI,finolex,RRkable, Apar, polycab) Rupees Three hundred
Seven Paise Four Only
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required
Rupees Seventy Four
13a depth for laying any size of cable or locating the fault all over the run and back 35.00 Mtr. 74.74
Paise Seventy Four Only
filling the same and making the surface as normal ground.
(B) If additional machinery like hammer driller or JCB use [Add] Rupees Four hundred
13b 2030.00 Mtr. 432.28 Thirty Two Paise Twenty
Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories
Rupees Sixty Two Paise
14 of same material at required depth in existing trench for laying of cable. below 2173.00 Mtr. 62.62
ground / road surface for enclosing cable (A)50 mm outer dia
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for
Rupees Thirty Eight Paise
15a PVC insulated armoured cable complete with out going tails, insulating tape etc 2.00 Ea 38.38
Thirty Eight Only
for following size of cables.(C) 2 to 4 core 10 Sq. mm
(E) 2 to 4 core 25 Sq. mm Rupees Fifty One Paise
Providing and, fixing heavy duty flange type brass double compression type
cable gland with rubber ring for PVC insulated armoured cable complete with out Rupees Seventy Five
going tails, insulating tape etc for following size of cables.(B) 3 & 1/2 core 35/50 Paise Seventy Five Only
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to switchgear Rupees Thirteen Paise
terminals with brass/cadmium plated nut bolts in an approved manner. (B) 10 Thirteen Only
(C) 16/25 Sq.mm. Rupees Fifteen Paise
(D) 35/50 Sq.mm. Rupees Twenty Paise
Supplying and erecting approved make Octagonal pole made from HR sheet
steel. The pole should be made as per IS. and shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard
profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and Rupees Fifteen Thousand
18 arrangement for cable termination to be erected With Suitable foundation 68.00 Ea 15411.59 Four hundred Eleven Paise
(Included) as per details given by manufacturer considering site requirement.(G) Fifty Nine Only
8 Mtr. Long 70 mm Top X 155 mm bottom dia, 3 mm thickness with
260mmX260mmX16mm base plate, 4-M20 Bolts and 600mm long with
necessary G.I. J Bolts Approx Pole weight 84 kg
(Make:Transrail,Bajaj,Utkarsh,Ambica)
QTY. UNIT RATE IN WORDS TOTAL
Providing and erecting Street Light pole bracket comprising main B Class GI pipe
of 4.2 cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of
approx. 45cms.length and suitable for 76.5 mm /80mm / required size of pole top
Rupees Six hundred Eighty
having sufficient fasteners for fixing the brackets and having spread of 1.5.mtr.
19 68.00 Ea 683.77 Three Paise Seventy
length with 110 deg.with vertical plane & suitable welded stays, reducer and with
check nuts complete painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following nos of arms. [A] Single
Arm Bracket 1.5 Mtr
Supplying & erecting IP 55 grade following size section pillar fabricated from joint
less M.S. Sheet with angle iron legs made from jointless M.S. Angle with cable
clamps to be buried in ground to have appropriate erection to work uniform until
erected with cement concrete foundation and 45 cm high bricks work finishing
with plaster etc. hinged double door internally supported on both side, with
internal and outside looking arrangement with look and keys in duplicate 35 x 35 Rupees Three Thousand
20 x 5 mm M.S. Angle of Two Nos. one is welded and other with nut and bolt for 1.00 Ea 3595.60 Five hundred Ninety Five
erecting Bakelite sheet. Painting the Section Pillar inside and out side with three Paise Sixty Only
tank powder coated paint. section pillar roof should be without joint with water
leakage proof & tested as per IP 55 test & followed by IS 2147 of 1962 (B) 75 X
60 X 45 cm section pillar fabricated from 16 Gauge MS Sheet with angle iron
legs 45 cm long made from 35 X 35 X 5 mm thick MS angle.
Supplying and erecting HYLAM sheet on existing angle iron frame.for following Rupees Seven hundred
21 thickness (B) 4mm 2.00 Sq. Mtr. 771.64 Seventy One Paise Sixty
Supplying & erecting approved make Digital time switch having lithium cell
years operative and operate battery backup 1 channel day clock with 14 memory
programme, suitable to operate on 240V + 5%, 16A with, floating contacts Rupees Three Thousand
22 Minimum switching setup time 1 minimum & LCD display. Also comprised 1.00 Ea. 3168.37 One hundred Sixty Eight
permanent ON/OFF switching. Programming switches & housed in fire proof Paise Thirty Seven Only
thermoplastic enclosure & transparent cover erected as required with necessary
connection erected as directed.
Supplying & erecting power contactor ,AC3 duty for time switch complete erected
Rupees Two Thousand
as per direction Cat III (D) 4 pole 440V 40 Amp.
23 1.00 Ea. 2782.55 Seven hundred Eighty Two
Paise Fifty Five Only
Supplying, erecting, testing, commissioning approved make M.S. Polygonal High
Mast Pole having following general Specification.
(a) Polygonal Section fabricated from M.S. Plate confirms BSEN 10025 & Hot
deep galvanized minimum 65/86 micron (as per IS 2629 /1985) Lantern carriage
with ring and rubber lines for erection of luminaries of suitable site.
(b) Maximum telescopic section not more than four
(c) Double drum gear pipe motorized winch with 6mm dia S.S. Rod (For 16 mtr
and above size)
(d) Approved make L.E.D. aviation light = 1 No. Lightening arrestor = 1 No. with
necessary wiring of 2.5 sq.mm 5 core ISI copper cable Unarmoured.
24 (e) Bottom most section suitable for mounting reversible motor and switchgears 0.00 0.00 0.00 Rupees Only
having door not more than 1400mm x 300mm with waterproof gasket & hinges &
locking arrangement.
(f) Pole structure comprises suitable size of reversible motor, cable and
necessary switchgears with control panel. (g) bottom section shall have suitable
size of thickness supports ribs foundation bolts nuts etc.
(h) Item not comprises the cost of lanterns.
(i) Necessary Cement Concrete foundation as per IS including testing &
commissioning of the entire structure for following size of High Mast poles
[1] High Mast 12 Mtr. TOP A/F 105 mm, BOTTOM A/F 360mm, No. of Sec. No. - Rupees One Lakh Sixty
1, Bottom Thickness - 3 mm, Size of Base Plate - Dia 520 mm x 20 mm thick, Two thousand Eight
Foundation Bolt Size M24 x 850 mm, Qty - 6 Nos., Suitable for mounting Fitting hundred Fifty Eight Paise
of Light - 6 Nos. Forty Six Only
Supplying and erecting approved make suitable panel indicator LED type lamp, Rupees Forty Three Paise
lens cover, complete erected with necessary connections. Forty Three Only
AMOUNT PUT TO TENDER FOR RS.
Special condition
As there is replacement warranty has to provide for LED fitting for 3 years, so security Deposit an amount Rs. 37,953/- will be released only after completion
of warranty period or the replacement of defective LED fitting whichever is later. Further after issuing the notice to the contractor for replacement of defective
material, he has to take up the work of replacement within 10 days from the date of issuing the said notice, in case where the delay for replacement, the contractor
shall be penalized by Rs. 100/- per day for such delay. In case of non replacement of the defective material action will be taken against the contractor to keep his
registration in abeyance for three years and his full security deposit will forfeited to the Government.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01.Notice Inviting Online tender.pdf
02.SBD.pdf
03.SCHEDULE - B.pdf
04.Online T.N. No.04 of 2026-27.pdf
05.LED Condition.pdf
06.Performance Bond and APS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .