Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹23.4 L+₹4.0 L (20.3%)Rejected-Finance C 234 ADG P CHENNAI | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹26.0 L+₹6.5 L (33.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹26.1 L+₹6.6 L (33.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹28.2 L+₹8.7 L (44.8%)Rejected-Finance 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹59,800
Closing Date
4 Apr 2022, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_512702_1
GE MAINT EZHIMALA 8455
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹59,800
Yes
27 Apr 2022
9 Mar 2022
6 Apr 2022
9 Mar 2022
4 Apr 2022
23 Mar 2022
10 Mar 2022 - 16 Mar 2022
Amount
Taking down and refix after completion of job works for ceiling fan / Exhaust fan / wall mounted fan of any sweep and make by disconnecting the electric connection, dismantling blades, down rods etc for checking and replacing the unserviceable parts complete all as specified and directed by Engr-in-charge. Note:- Unserviceable spare parts shall be measured and paid seperately under relevent items of BOQ.
M&L for checking / replacing the worn out parts such as rubber pully, locking pin, nuts and washer of Ceiling fan any size complete with one coat of synthetic enamel white paint by spraying after cleaning all dust etc complete all as specified and directed by Engr-in-Charge.
M&L for painting exhaust fan of any sweep complete with one coat of synthetic enamel suitable paint by spraying after cleaning all dust etc complete all as specified an directed by Engr-in-Charge.
M&L for painting wall mounting fan / air circulator of any sweep complete with one coat of synthectic enamel suitable paint by spraying after cleaning all dust etc complete all as specified and directed by Engr-in-Charge Note:- Repair for Item No 2,3 & 4 shall be measured and paid seperately.
M&L for dismantling / opening the ceiling fan of 1200/1400 mm sweep of any make removing the old defective winding carefully cleaning the inner parts and re-winding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specifed and directed by Engineer-in-Charge.
M&L for dismantling/opening the exhaust fan of 300 mm sweep of metal body any make removing the old defective winding carefully cleaning the inner parts and rewinding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and directed by Engineer-in-Charge.
All as per item No.6 above but for 450 mm sweep exhaust fan metal body complete all as specified and directed by Engineer-in-Charge.
All as per item No.6 above but for metal body 225 mm sweep exhaust fan complete all as specified and directed by Engineer-in-Charge.
All as per item No.6 above but for plastic body 250 mm sweep exhaust fan complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling/opening the wall mounted fan 400mm sweep of metal body any make removing the old defective winding carefully cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling/opening the air circulator fan 630 mm sweep of metal body any make removing the old defective winding carefully cleaning the inner parts and rewinding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling/opening the air circulator 400/450mm sweep of metal body any make removing the old defective winding carefully cleaning the inner parts and rewinding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling ceiling fan of any size and sweep removing old bearing and bushes of any size supply and fixing new bearing suitable size of make SKF /TATA /NBC and bushes including greasing and reassembling and testing complete all as specified and directed by Engr-in-charge.
M&L for dismantling wall mounting fan of any size and sweep removing old bearing and bushes of any size supply and fixing new bearing suitable size of make SKF/TATA/NBC and bushes including greasing, reassembling and testing complete all as specified and directed by Engr-in-charge.
M&L for dismantling exhaust fan of any size and sweep removing old bearing and bushes of any size supply and fix with new bearing suitable size of make TATA/NBC/SKF and bushes including greasing, reassembling and testing complete all as specified and directed by Engr-in-charge.
M&L for removing old unserviceable fan capacitor and material and labour for fixing new capacitor 2.5mfd 440Volts of suitable make, size and testing the fan complete all as specified and directed by Engr-in-charge.
M&L for removing defective old capacitor, supply and fix new capacitor of 4 mfd suitable for exhaust fan/Air circulator of any size, make, model and testing complete all as specified and directed by Engr-in-charge.
M&L for removing defective old capacitor, supply and fix new capacitor of 6 mfd suitable for exhaust fan/Air circulator of any size, make, model and testing complete all as specified and directed by Engr-in-charge.
S&F Exhaust fan louver up to 300 mm dia including taking down of old louver and matching disturbed surface by proper painting all as directed by Engineer-in-Charge.
S&F Exhaust fan louver 450 mm dia including taking down of old louver and matching disturbed surface by proper painting complete all as specified and directed by Engr-in-charge.
S&F Ceiling fan blade 1200/1400mm sweep as per sample complete all as specified and directed by Engineer-in-Charge.
S&F Exhaust fan blade 300/450 sweep complete all as specified and directed by Engineer-in-Charge.
S&F Exhaust fan blade 225mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F Exhaust fan blade 250mm sweep (plastic) complete all as specified and directed by Engineer-in-Charge.
S&F wall mounted fan blade 400/630mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F air circulator blade 450/630mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of base asssembly of air circulator including painting of matching colour for any sweep complete all as specified and directed by Engr-in-charge.
S&F in replacement of rear dom of air circulator including painting of matching colour as per front side for any sweep complete all as specified and directed by Engr-in-charge.
S&F wall mounted fan grill set complete including taking down of old one for any sweep as per sample complete all as specified and directed by Engr-in-charge.
S&F air circulator grill set complete including taking down of old one for any sweep as per sample complete all as specified and directed by Engr-in-charge.
Supply and fix ceiling fan down rod as approved of any sweep and 2.1 mtr long complete all as specified and directed by Engr-in-charge.
Supply and fix ceiling fan down rod as approved of any sweep and 1.5 mtr long complete all as specified and directed by Engr-in-charge.
Supply and fix ceiling fan down rod as approved of any sweep and 0.9 mtr long complete all as specified and directed by Engr-in-charge.
S&F in replacement canopy of matching colour as existing suitable for ceiling fan of any sweep complete all as specifed and directed by Engineer-in-Charge.
M&L for dismantling the existing Geyser 25/50 ltrs capacity on it portion and transporting to work shop for repair, opening the body carefully and taken out the copper container and arrest the water leakage by bracing/soldering the copper/brass rods and refixing and return back to site and refixing the existing loccation complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing thermostat 0° C to 80° C for Geyser complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing Geyser element 1500W, Cup type complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing Geyser element 1500 W, Triangular type complete all as specifed and directed by Engineer-in-Charge.
Supply and fixing PVC hot water connection pipe 45 cm long complete all as specifed and directed by Engineer-in-Charge.
supply anf fixing indication lamp square/round in red and green colour, 230 Volts AC complete all as specifed and directed by Engineer-in-Charge.
GMS Builders
PADMANABHAN. K.V
General Engineering and Constructions
Benchmark Engineers and Contractors
KDR CONSTRUCTION
Gates Infra Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .