Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr | L1 | Accepted-AOC Lowest bid value |
| 2 | L2₹3.6 Cr+₹1.8 L (0.51%)Rejected-Finance | ₹3.6 Cr+₹1.8 L (0.51%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹3.7 Cr+₹10.8 L (2.98%)Rejected-Finance | ₹3.7 Cr+₹10.8 L (2.98%) | L3 | Rejected-Finance Higher bid value |
Tender Value
Refer Docs
EMD Value
₹4.3 L
Closing Date
18 Nov 2020, 6:00 pmClosed
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA, KALAIKUNDA AIR FIELD POST , DIST WEST MEDINIPORE,721303
CONSTRUCTION OF NEW STATION REFUELING SECTION
2020_MES_381471_1
8216/BKP/08/E8
Open Tender
Civil Works
Lump-sum
545 days
AT AF STN BARRACKPORE
Class A, Category a(I)
2 documents required · 2 mandatory
₹2,000
Yes
GE AF BARRACKPORE
₹4.3 L
Yes
CWE AF KALAIKUNDA
19 Jan 2021
28 Sept 2020
20 Nov 2020
28 Sept 2020
18 Nov 2020
30 Oct 2020
29 Sept 2020 - 12 Oct 2020
13 Oct 2020
Amount
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Office cum lab building complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Refueller garrage cum servicing /repair bay with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of DI point for refuelling section with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Aerolube & POL store with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Car & Motor cycle parking with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of static water tank of capacity 25000 gallons with permanent specification complete all as specified and shown in drawing.( Ref.DRG No. AF/TD/30 , sheet No.1/1)
Total amount of Sch 'A' Part-II (SITE CLEARANCE / SITE DEVELOPMENT ) Prepriced amount B/F from Sl page No. 40R
Total amount of Sch 'A' Part-III (ROAD/ PATH / CULVERT) Prepriced amount B/F from Sl page No. 44
Total amount of Sch 'A' Part-IV (AREA DRAINAGE ) Prepriced amount B/F from Sl page No. 47
Total amount of Sch 'A' Part-V( BOUNDARY WALL /GATE) Prepriced amount B/F from Sl page No.53
Total amount of Sch 'A' Part-VI (EXTERNAL ELECTRIC SUPPLY ) Prepriced amount B/F from Sl page No. 59
Total amount of Sch 'A' Part-VII (EXTERNAL WATER SUPPLY ) Prepriced amount B/F from Sl page No. 60
Total amount of Sch 'A' Part-VIII (INTERNAL ELECTRIC SUPPLY ) Prepriced amount B/F from Sl page No. 65
Total amount of Sch 'A' Part-IX (INTERNAL WATER SUPPLY) Prepriced amount B/F from Sl page No. 67
Total amount of Sch 'A' Part-X (AIR CONDITIONER ) Prepriced amount B/F from Sl page No. 68
Total amount of Sch 'A' Part-XI (LIGHTENING PROTECTION ) Prepriced amount B/F from Sl page No. 70
Sch 'A' Part-XII (Misc Items) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
M&L Preparation of new or previously treated surfaces and laying of hot applied thermoplastic paint 2.5 mm thick reflectorising glass beads @ 250 gm/sqm area, thickness of 2.5 mm is inclusive of surface applied glass beads as per IRC: 53. all as specified and as directed
S&F Chiain Link Fencing 100 x100mm Mesh or cages with 3.8mm to 4.00mm dia steel Galvanised wire complete all as directed by Engr-in-charge.
M&L for preparation newly plastered surface and applying two coats of weather coat over one coat of primer complete all as specified and as directed.
Materials and labour for bricks, sub class ‘B’ laid flat for cable protection complete all as specified and directed.
Supply and fixing cable route indicator for HT UG Cable of 11000 Volts 80 mm dia CI Plate marked on HT cable bolted with 40 x 5 mm flat iron member of height 0.9 mtr, embedded in PCC 1 : 3 : 6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling of poles complete all as specified and as directed.
M&L PCC (1:2:4) type B-1 using 20mm graded stone for coping of pole including form work complete all as directed by Engineer -in- Charge
Supply, installation, commissioning and testing of LT feeder pillar outdoor type of size 1.50 m x 1.00 m x 0.60 m factory made (CPRI approved), single door, both side openable with hinged and locking arrangement, outgoing cable chamber with same rated aluminium strip from cable chamber to MCCB output, made out of 3.15mm thick mild steel CRCA sheet supported and fixed on structrual frame of angle iron of size 50 x 50 x 5 mm angle iron frame including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with 4 legs of 0.5 mtr duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), suitable for 3 phase 4 wire system 440 volts grade with necessary wiring with PVC sheathed stranded copper conductor of appropriate length size with and including fixing lugs, bolts, screws etc complete all as directed by the Engr-in-Charge and comprising of the following accessories :- (a) Copper bus bar of rated capacity 200 Amps of size 20x3mm thick, 0.75 mtr long. ( 7.5 Cm gap between two bas bar).
Item 20 contd (b) MCCB 100 A 415 V, 4 pole, 50 Hz, 35 KA (Fixed Thermal & Fixed magnetic release) - 01 Nos (Incomming).Make- L&T (c) MCCB 63A TPN, 415 Volt, 25 KA (Fixed Thermal & Fixed magnetic release - 01 Nos (Outgoing).Make- L&T (d) MCB 25A TPN, 415 Volt, 25 KA (Fixed Thermal & Fixed magnetic release - 01 Nos (Outgoing).Make- L&T (e) MCB 32A TPN, 415 Volt, 25 KA (Fixed Thermal & Fixed magnetic release - 02 Nos (Outgoing).Make- L&T (f) LED indicator lamp (Yellow, Blue, Red)- 01 Set (Set of Three).Make-AE/HPL (g) Time switch 3 phase 20Amp, 415 Volt.Make- L&T (h) 3 Phase Multifunction Meter, Model C Class 1, 3 Phase, 5A with Relay. -- 01 Nos.Make- SocoMac(HPL)
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
Supply and fix flame proof weather proof LED flood light fittings suitable for 120 W complete all as specified and directed.
M&L for loop box out door type made out of 2mm thick MS sheet, size 450 x 300 x 150mm, factory made cubicle shaped total enclosed dust proof , having front, opening and locking arrangement including four aluminium bus bar on porcelain bridge insulator , one porcelain cut out of 16 Amps capacity and enamel danger notice plate duly fixed on the pole by MS clamp of suitable sizes, painted with 2 coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed by Engineer –in- Charge.
M&L for cutting, bending, welding, drilling hole on angle iron of size 60mm x 60mm x 5mm for making arrangementfor for fixing of weather proof metal halide light fittings including making of suitable size clamps and the same to be painted with two coat of synthetic enamel paint over a coat of red oxaide all as specified and directed.
Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 75 mm including all fittings complete all as directed by Engr-in-charge.
All as per item No.25, but 50 mm (2”) dia complete all as directed by Engr-in-charge.
All as per item No.25, but 25 mm (1”) dia complete all as directed by Engr-in-charge.
Supply and fix PPR Gate Valves (Brass Insert) of 50 mm bore complete all as directed by Engr-in-charge. .
Supply and fix PPR Gate Valves (Brass Insert) of 25 mm bore complete all as directed by Engr-in-charge. .
M&L for reconstruction of brick masonry valve pit of size 90cm x 90 cm x 90cm (internal dimension) with one brick thick P.C.C 1:4:8 type D-2 (using 20mm graded crashed stone aggregate) as in foundation concrete incl PCC (1:3:6) type CI (using 20mm graded crashed stone aggregate) as in bedding and coping 10mm thick cement plaster in Cement mortar (1:4) internally & externally upto 15 cm below ground level providing valve pit 50x50x6mm angle iron frame all round the fixed point by means of 4 Nos hold fast 150mm long made out of flat iron 40 x 6 mm embedded in PCC block (1:2:4) type B-I (using 20mm graded crashed stone aggregate) of size 230 x200 x100mm. incl provn of hing welded with angle iron frame and Mild Steel cover 3 mm thick, Mild steel handle of suitable and size welded with MildSteel cover & suitable locking arrangement & applying two coats of synthetic enamel paint over a coat of red-oxide primer incl necessary excavation work in soft/ loss soil complete all as specified & directed
Cutting cast Iron pipesof 80/100 mm dia ,in position insertion of new tees,branch and reducing to required length before laying including necessry connection complete all as specified and directed.
S&F water jet spray for EWC complete all as specified and directed.
Supply and fix flame proof weather proof fluorescent fixture Cromptom Flameproof LED Tubelights -EXTN2LT816/20 - SUITABLE FOR 2 x 16W LED tubelight. Gas Gr Iia/IIB.complete all as specified and directed.
Supply and fixing flame proof exhaust fan of size 12", Exhaust Fan having sweep size of 12” , having air discharge capacity of 1120 CFM, complete with 0.25 HP, Single phase, 240v, 1440RPM capacity of motor duly approved and certified by CIMFR Dhanbad for gas group IIA & IIB complete all specified and directed by Engr-in-Charge.
Supply and fixing New ASTRA Bldg street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass and 25 Watt completeall specified and directed by Engr-in-Charge.
Supply and fixing Indoor LED recessed mounted fitting in diffused type 36 Watt 2ftx2ft complete with all accessories 3 core copper wire for connection, making good the disturbed ceiling complete all as specified and directed.
S & F Energy efficient tube light fitting with LED batten type luminaire, extruded aluminium body with completely pre wired with driver internally fixed and decorative caps , 20W, 230V , with connector blok, etc., complete with all accessories and connecting up with suitable size, 1.5 sqmm three core copper conductor flexible wire , screws , gutties etccomplete all as specified and directed. complete.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated
S&F SPN 40 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series. Including dismentling taking down unsvericeable one.
S&F MCB SP, 10KA, 230V, C-curve, 6-32 amps incl dismentling/taking down unsv one.
S & F Crompton Flame proof LED tube lights Cat Part No- EXTN1LT8- 16/20- suitable for 1x16 W LED tube light complete all as specified and directed.
Supply and fixing flame proof exhaust fan of size 12", Exhaust Fan having sweep size of 12” , having air discharge capacity of 1120 CFM, complete with 0.25 HP, Single phase, 240v, 1440RPM capacity of motor duly approved and certified by CIMFR Dhanbad for gas group IIA & IIB complete all specified and directed by Engr-in-Charge.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 2 TR, BEE 5 star rated complete all as directed by Engr-in-charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as directed by Engr-in-charge.
M&L for RCC NP3 150mm dia pipes laid for depth 0.70m-1.65m with PCC cradle 150mm thick in PCC 1:4:8 0n 150mm thick bed with excavation in any type of soil incl manholes/ drop manhole of standard size made of brick masonry/RCC/Precast with SFRC ventilating cover and frame includes all items and activities to execute and make sewer line functional.
M&LConventional type 50 users RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for complete all as specified and as shown on TD DRG Ref AF/TD/233 sheet 1/2 & 2/2 as specified.
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth complete all as specified and as shown on TD DRG Ref AF/TD/STRU/236 sheet 1/2 & 2/2 as specified.
Supply and fixing in replacement LED tube light fittings with Led tube rod of 20W, 230V, with connector blok, etc., complete with all accessories internally pre-wired and including connecting up with suitable size, 1.5 sqmm three core copper conductor flexible wire , screws , gutties etc. all as specified and directed. ( Note- Rate are inclusive of 4 feet Patti and 4 Feet 20W Led Tube Rod both are measured of unit qnty).
BUSINESS SYNDICATE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .