Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.3 L+₹9,849.86 (1.60%)Rejected-AOC ELAVANCHERRY GP PALAKKAD | PALAKKAD | KERALA | 672122 | L2 | Rejected-AOC L2 |
Tender Value
₹6.2 L
EMD Value
₹15,446
Closing Date
12 Feb 2024, 2:00 pmClosed
Assistant Executive Engineer
WSP SUB DIVISION HARIPAD, KWA
DEPOSIT WORK 2023-2024 THRIKKUNNAPPUZHA GRAMA PANCHAYAT RWSS TO THRIKKUNNAPPUZHA CONSTRUCTION OF TEMPORARY PUMP HOUSE LAYING PUMPING MAIN COMMISSIONING OF NEW TUBE WELL AND SUPPLY ERECTION OF PUMP SET IN WARD 4
2024_KWA_645937_1
WRD/KWA-CE(CR)/TR/12626/2023
Open Tender
Civil Works - Water Works
Item Rate
180 days
WSP SUB DIVISION HARIPAD
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,611
Yes
₹15,446
Yes
21 Feb 2024
18 Jan 2024
13 Feb 2024
18 Jan 2024
12 Feb 2024
18 Jan 2024
Amount
APPENDIX A - PART 1 :- CIVIL WORK - CONSTRUCTION OF TEMPORARY PUMP HOUSE
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
50.6.1.7:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
9.95.3:Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:100x75x4 mm
9.97.3:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
APPENDIX B - PART II :- CONSTRUCTION OF PUMP HOUSE - ELECTRIFICATION WORK.
OD108887/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed mediumclass PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper Group B conductor single core cable etc. as required
OD108888/2023-2024:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with lSI marked HRC fuses including drilling holes in cubiclepanel, making connections, etc. as required. 63ATP&N
OD108889/2023-2024:Earthing with G.l. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate Jlaving locking arrangement and watering pipe etc. with charcoal/coke and salt as required
OD108890/2023-2024:Installation, testing and commissioning of pre-wired, fluorescent fitting I compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc.directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
OD108891/2023-2024:Supplying 36/40W Fluorescent Lamp with all accessories
OD108892/2023-2024:Supplying and fixing metal box of 200 mm X 125 mm X 60 mm size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
OD108893/2023-2024:Supplying and providing meter box and panel board for KSEB supply and providing necessary fuse unit and isolators for 3 phase supply as per the direction of departmental officers.
APPENDIX C - PART I :-LAYING PUMPING MAIN - WORKING CHARGES.
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.98.1008:Engaging Coolie.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
OD113197/2023-2024:Interconnecting the newly laid 90 mm PVC. Pipe line to the existing line, by cutting the existing 160 PVC. Line diametrically, the cut being diametrically perpendicular to the axis of pipe and smoothening of cut ends, inserting the 160mmx90mm PVC ‘TEE’,90 mm CIR Joint supplied by the contractor and placing in position, jointing with solvent cement and testing to the required test pressure, including cost of ‘TEE supplied by the contractor, labour charges , and hire for tools etc; complete.
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
OD114426/2023-2024:Constructing valve chamber of inner size 1.5 m x 1.5 m x 1.5 m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(115 Kg) for Base slab & side wall and 12 mm MS rod (102 Kg) for cover slab.(Base slab 1.8 mx1.8 mx0.15 m,side wall 15 cm thick,cover slab 3 Nos of size 1.8 mx0.6 m x 0.20 m)over a PCC base of size 2 mx2 mx0.10 m in 1:3:6 using 40 mm broken stone,plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
APPENDIX C - PART II :-LAYING PUMPING MAIN - COST OF MATERIALS
100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia.
100.98.484:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm.
OD114456/2023-2024:Supplying 90 mm PVC bend (10 Kg /cm2)
APPENDIX D :-SUPPLY, ERECTION AND COMMISSIONING OF SUBMERSIBLE PUMP SET
OD115481/2023-2024:Supplying 80 mm GI Class B pipe (weight not less than 8.5 Kg/M) having ISI mark.
OD115673/2023-2024:Supplying 80mm Tee
OD115674/2023-2024:Supplying good quality 80mm GI BEND
OD115703/2023-2024: Supply and fixing 63A fuse unit
OD115704/2023-2024:Supply and fixing of 63A 4pole change over switch
OD108881/2023-2024:Supplying 3X4mm sq. submersible cable having ISI mark
OD114414/2023-2024:Supply, conveying and fittings with specials of 80 mm Flexiible PVC hose
OD122879/2023-2024:Supplying ,conveying and fixing 500 v Voltmeter (deducting all the GST amount )
OD123910/2023-2024:Supplying ,conveying and fixing 0-60 amp ammeter with suitable coils (deducting all the GST amount )
OD123916/2023-2024:Supplying ,conveying and fixing single phase preventer (deducting all the GST amount )
OD123924/2023-2024:Supplying ,conveying and fixing , 63 amps -100 ma change over switch MCB HPL (deducting all the GST amount )
OD123989/2023-2024:Supplying ,conveying and fixing , 63 amps-100ma ELCB/RCCB (deducting all the GST amount )
OD124045/2023-2024:Supplying ,conveying and fixing 100A Fuse carrier (deducting all the GST amount )
Suresh K
Bidder Name
C Jayaprasad
Suresh K
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_989578.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .