Executive Engineer (E)
O/o EE(E) PWD EMD M-351, R.No.185, Old Sectt Delhi
RMO Electrical and Mechanical Services at Various Social Welfare Building at Sewa Kutir, Kingsway Camp, Delhi-54 (Sh- Day to Day Maintenance of E and M Services for FY 2026-27).
2026_PWD_286853_1
123/2025-26/EMD M-351/EE(E)
Open Tender
Miscellaneous Services
365 days
Sewa Kutir
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹48,026
20 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
Routine maintenance and attending day to day complaints of electrical installations and compound lights/ High mast/street lights/ security lights including repairing the wiring and light fixtures complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register and on online complaint management system, testing the insulation resistance, earth resistance etc. and providing assistance to the Engineer-in-charge during breakdown maintenance complete with replacement of worn-out parts (To be issued by the department on complaint basis but electrical tapes, T&P required for replacement of defective electrical parts and tools, safety equipment’s for deployed labour and stationary items such as logbooks, complaint registers, worker diary, Biometric attendance system will be provided by the contractor the rates deemed to be include in the tender nothing extra will be paid on account of these) including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets along with sluice/ gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation and running maintenance & operation and general upkeep & cleaning of LT Panels alongwith allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/ load shedding including periodical checking of DG set for their proper functioning alongwith minor repair works, as and when required and recording reading in log book as and when required, keeping the entire installation on functional mode by deploying staff at sewa kutir, Delhi as per terms & conditions attached. i) Wireman cum pump operator = 3 Nos. (round the clock) ii) Khallasi = 2 Nos. (9 AM to 5 PM & 10 PM to 6AM)
Name of Buildings:- (i) Blind Hostel (ii) Blind School (iii) CWC Building (iv) JJB-I Court (v) RCC Building vi) OHB-II (vii) Poor House Hospital & Court (viii) JJB-III Court (ix) District Office (Ladli Yojana Bldg) (x) Poor House Court
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. i) Group C
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 8 way double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole
Single pole and neutral
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 8 way (4 + 24), Double door
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amps switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying, Installation, Testing & Commissioning of SMC pole Box of size 250mm x 200mm x 105mm with hinged cover on surface/ recess/pole complete with aluminium connector strip - 2 Nos, MS Clamp - 2 Nos., 6-32amp. C series SPMCB- 1 No., having IP: 66 protection connection etc. as reqd.
S.I.T.C of following LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 66, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.95, CRI > 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency > 85%, 10 kv surge protection, L-70 Life 50,000 burning hours. complete i/c dismantling of existing fitting if any, connection, etc complete as reqd. (Note:- Contractor shall submit 5 Years guarantee certificate of respective manufacturer along with the fitting).
Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
Supplying and laying one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 kV grade of following size on existing DWC Pipe/on wall surface etc as required. i) 3 x 10 sqmm
Credit for old dismantle items
MCCB DB
Assorted switch &Socket
Assorted size LED Fixtures
Assorted Size Celing/Exhaust Fans
Assorted size copper wire pvc insulated
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.78 MB
123DaytodayMaintEMSewaKutirKingswayCamp.pdf
Tender Documents • 2.77 MB
BOQ_379911.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid