Chief Officer
MC Osmanabad
Providing Electrician Wireman clearing line by clearing sag etc for Municipal Council Osmanabad
2022_DMA_786874_15
MC/Ele/2022-23/1
Open Tender
Miscellaneous Services
Item Rate
365 days
Osmanabad
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹5,000
4 Aug 2022
5 May 2022
13 May 2022
5 May 2022
11 May 2022
5 May 2022
365 days
Amount
Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC (only clearing line by doing erection of line properly clearing sag,etc.)
Supplying and erecting mains with ISI mark WP 2 x 2.5 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.(only erection of line by using supplied wire of Municipal Council)
Supplying and erecting mains with ISI mark WP 3 x 4 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire(only erection of line by using supplied wire of Municipal Council)
Supplying, erecting & marking SPN MCB 40A, B-series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB (only erection )
Carrying out servicing of DG set upto 50 kVA with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification no. GEN-SER-AMC
Providing annual comprehensive maintenance contract for 1 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job excludes sheet metal work and pastic material.
Providing annual comprehensive maintenance contract for 1.5 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material.
supply wireman for one day (As per MJP CSR 2021-22)
Supply Electrician For one day (As per MJP CSR 2021-22)
Supplying and erecting V-Belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for DG set upto 100kVA
Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set upto 62.5 kVA.
Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for DG Set upto 50 kVA.
Supplying and erecting stop solenoid assembly 12V/24V single coil energized to run with or without primary etc complete suitable for DG set upto 125 kVA.
Supplying and erecting Air cleaner/Air filter element suitable for DG set upto 40 kVA
Supplying and erecting set of engine safety unit suitable for DG set upto 125 kVA as per specification no
Supplying and erecting SMPS based Battery Charger input voltage 230 V A.C. & output voltage 24 V DC, charging current 20A suitable to charge DG set Battery
Supplying, erecting, testing and commissioning 4 pole power contactor 63 A with coil voltage of 220/240 V suitable to operate on AV voltage for DG set.
Supplying, erecting, testing and commissioning 4 pole power contactor 80-130A with coil voltage of 220/240 V suitable to operate on AV voltage for DG set.
Supplying & erecting 12 V 80 Ah heavy duty plate type Battery with terminal wire duly charged complete suitable for DG set with warrantee for 3 years
Providing replacement of existing unservicable rotary/scroll compressor of air conditioner 1 TR by new one of same capacity with guarantee for one year with provided refrigerant complete.
Providing replacement of existing unservicable rotary/scroll compressor of air conditioner 1.5 TR by new one of same capacity with guarantee for one year with provided refrigerant complete.
Providing replacement of existing unservicable rotary/scroll compressor of air conditioner 2 TR by new one of same capacity with guarantee for one year with provided refrigerant complete.
Providing flushing out cooling coil and condensor coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure in an approved manner.
Providing brazing pipes and checking leakages in the split/ window unit duly with dry nitrogen pressure in an approved manner.
Providing replacement of unserviceable starting relay for AC unit.
Providing replacement of unserviceable starting capacitor for A/C unit.
Providing replacement of unserviceable running capacitor for A/C unit.
Providing replacement of unserviceable fan motor capacitor for A/C unit.
Providing replacement of unserviceable PCB for A/C unit upto 3 TR capacity.
Providing repair of of faulty PCB for air conditioning unit upto 3 TR capacity.
Supplying and installing of new fan motor for condenser for air conditioning unit
Supplying and installing of new fan motor for indoor unit of air conditioner up to 3 TR suitable to operate on 230V to 250V AC or 280V to 340V DC supply having 4 to 8 poles as per requirement.
Supplying and installing new fan blade outdoor unit for air conditioning unit.
Providing replacement of blower of indoor unit for air conditioning unit.
Providing replacement of remote of indoor unit for air conditioning unit.
Providing vaccumising the airconditioner system and charging with R-22 refrigerant for air conditioning unit.
Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 1TR window/split air conditioning unit.
Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 1.5TR window/split air conditioning unit.
Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 2TR window/split air conditioning unit.
M/S. Kuldeep Electricals
E HOUSE ELECTRICALS
tech_bid_open.pdf
tech_eval
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .