Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
DEPOSIT-Veterinary Dispensary Koottumugham-SITC of 3Kva Inverter-General Electrical Work
2025_PWD_739855_3
PWD/BLDG/TR/19123/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
60 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
₹2,072
15 Oct 2026
15 Oct 2026
29 Oct 2026
15 Oct 2026
26 Oct 2026
15 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ELETRIFICATION | |||||
| 1.001 | OD156556/2023-2024:Supply & Installation, Testing and Commissioning of 3Kva,24V Sine Wave INVERTER With following configuration. Input Voltage: Single Phase,230V AC-45-55Hz. Output Waveform: True sine wave. Output Voltage: Single Phase 230V AC, Voltage Regulation +/-1%. Power Factor: 0.8 to Unity. Overload Capacity: 100% - 125%. Indicators: Mains ON,Inverter ON,Battery ON charge, Overload etc. Battery: Tubular(150Ah x 2Nos - Preferable Make Exide/Equivalent). and suitable battery rack Warranty: 2 Years for Inverter & 3 Years for Tubular Battery | 1 | each | - | - |
| 1.002 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door | 1 | each | - | - |
| 1.003 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | 1 | each | - | - |
| 1.004 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 2 | each | - | - |
| 1.005 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps | 1 | each | - | - |
| 1.006 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 6 | each | - | - |
| 1.007 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | 2 | each | - | - |
| 1.008 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) | 5 | each | - | - |
| 1.009 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) | 1 | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
BOQ_1496560.xls
BOQ • 0.31 MB
MOM.pdf
Tender Documents • 0.21 MB
viewnit.pdf
Tender Documents • 0.02 MB
viewsbd.pdf
Tender Documents • 1.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .