Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.6 LAccepted-AOC | ₹7.6 L | 1 | Accepted-AOC Awarded |
| 2 | 2₹7.6 LRejected-AOC | ₹7.6 L | 2 | Rejected-AOC Not Awarded |
| 3 | 3₹7.6 LRejected-AOC | ₹7.6 L | 3 | Rejected-AOC Not Awarded |
Tender Value
₹7.8 L
EMD Value
₹8,000
Closing Date
2 Apr 2020, 5:00 pmClosed
S.E., E.T.C., Bareilly
Superintending Engineer Transmission Campus Near L.I.C. Office Rampur Garden, Bareilly
Construction of 33KV AMP Solar Feeder - I and II Bays including Extension of Switchyard alongwith other associated Works at 132KV S.A.S. Sub Station Nawab Ganj, Bareilly under E.T.D. - II, Bareilly
2020_UPTCL_456203_1
Short Term E-Tender No. 107 / W / ETC(B) /2019-20
Open Tender
Electrical Works
60 days
Bareilly
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
A/c No 10897666087 IFSC SBIN0000615 S.B.I. Bly
₹8,000
18 Sept 2020
27 Mar 2020
3 Apr 2020
27 Mar 2020
2 Apr 2020
27 Mar 2020
27 Mar 2020 - 2 Apr 2020
Amount
Construction of 33KV AMP Solar Feeder - I & II Bays including Extension of Switchyard alongwith other associated Works at 132KV S.A.S. Sub Station Nawab Ganj, Bareilly, with all Cost of Men, Materials, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer as per Site Requirement and Details below : (1) Carriage of Misc. Items like Structures, CTs, PTs, Isolators, Control Cables, Conductors, Junction Boxes, M.S. Round Bar, M.S. Earthing Strips etc. from Designated Primary Sub Station within 50 Km Distance to 132KV S.A.S. Sub Station Nawab Ganj including its Loading and Un-Loading.
(2) Erection of Main & Aux. Structures including their Shifting from Storage Place at the Sub Station to Erection Site.
(3) Laying & Stringing of 33KV 3f Main Bus Bar, Transfer Bus Bar & Jack Bus Bar including Hoisting of Disc Insulator Strings, Tension Fittings etc. alongwith Shifting of the Conductors / Materials from Storage Place at the Sub Station to Erection Site as per Details below : (a) Stringing of 33KV 3 Main Bus Bar of Single ACSR Moose Conductor. (1 Job for each Phase of Bus Bar per Section)
(b) Stringing of 33KV 3f Transfer Bus Bar of Single ACSR Panther Conductor. (1 Job for each Phase of Bus Bar per Section)
(c) Stringing of 33KV 3f Jack Bus Bar of Single ACSR Panther Conductor. (1 Job for each Phase of Bus Bar per Section)
(4) Erection of Following Equipments in 33KV AMP Solar Feeder - I & II Bays including their Shifting from Storage Place at the Sub Station to Erection Site : (a) 33KV SF6 C.B.
(b) 33KV C.T.
(c) 33KV P.T.
(d) 33KV Bus Isolator with associated PIs
(e) 33KV Line Isolator with associated Earth Blades & PIs
(f) 33KV C.T. Junction Box
(g) 33KV P.T. Junction Box
(h) 33KV Feeder Control & Relay Panel
(i) ABT Energy Meter Cubical
(5) Interconnection & Jumpering of Equipments of 33KV AMP Solar Feeder - I & II Bays with the help of ACSR Panther Conductor to Connect the Bus Bar Conductor of Main Bus, Transfer Bus & Jack Bus with Equipments and Equipments to Equipments with the help of suitable Clamps / Connectors including, Cutting, Bending, Shaping etc. of the Conductor as per Site Requirement. (1 Job per Bay)
(6) Providing & Laying of Following sizes G.I. Pipes for Pilfer Proof Metering from C.T. / P.T. Junction Boxes in33KV AMP Solar Feeder - I & II Bays in Switchyard to Metering Cubical Box in Control Room for Laying of Control Cables through G.I. Pipes as per Site Requirement alongwith associated Work such as Cutting, Making, Threads for Fitting of Sockets, Elbows, Dressing etc. with due Earthing of Laid G.I. Pipe at each end : (a) 2" dia. G.I. Pipe
(b) 1" dia. G.I. Pipe
(7) Laying of Following sizes Control Cables in Cable Trenches from Control & Relay Panels in Control Room to various Equipments, Junctions Boxes etc. in Switchyard as per Cable Schedule including Shifting of Cables in Drums from Storage Place at the Sub Station to Erection Site and Shifting Back the Balance Cables to Stores at the Sub Station : (a) 2C x 2.5 mm2
(b) 4C x 2.5 mm2
(c) 6C x 2.5 mm2
(8) Termination of various sizes above Laid Control Cables Extending D.C. Supply from DCDB and A.C. Supply from ACDB to Control Panels & Equipments including Drilling of Holes, Providing and Fixing of Cable Glands, Ferrules & Crimping type Lugs. (1 Job per Bay)
(9) Earthing by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of following sizes M.S. Flats for Diagonal / Double Earthing of the Main & Aux. Structures, Equipments and Cable Trenches including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below : (a) Earthing of Main & Aux. Structures and Equipments (CB, Isolators, CTs, PTs, C&R Panel, DPP, Junction Boxes etc. with 50 × 6 mm size M.S. Flat.
(b) Earthing of Cable Trench with 25 mm × 6 mm / 25 × 5 mm size M.S. Flat
(10) Painting of M.S. Earthing Strips by Rubbing with Sand Paper & Wire Brush, then Painting with 1 Coat of Red Oxide Primer & 2 Coats (The 2nd Coat of Paint shall be Applied at the Gap of 48 hrs. when 1st Coat of Paint is done & Checked by concerned S.D.O.. / J.E.) of 1st Quality Synthetic Enamel Paint of Asian / Berger / Nerolac make in Bus Green / Black Colour as per Details below : (a) 50 × 6 mm size M.S. Earthing Strip in Bus Green Colour.
(b) 25 × 6 mm / 25 × 5 mm size M.S. Earthing Strip in Black Colour.
(11) Providing of 3 Phase L.T. A.C. Supply Cubical of size 1200 × 600 × 500 mm with Hinged Door and Proper Locking Arrangement duly made of 16 SWG M.S. Sheet and Painted with Grey Colour Synthetic Enamel Paint. The L.T. A.C. Supply Cubical should be Fitted with 3 No. 100 Amp. Copper Neutral Link, 4 No. 100 Amp. Aluminum Bus Bar (3 Phase + Neutral), 5 No. 32 Amp. TPN MCB, 6 No. 40 Amp. DP MCB, 40 No. Link type Terminal Bock, Cable Glands etc. with Internal Wiring and then Installation on M.S. Angle Frame Structure duly Grouted in Ground by due Construction of Concrete Plinth.
(12) Earthing of L.T. A.C. Supply Cubical with Providing & Fixing of 600 × 800 × 8 mm size G.I. Plate with its Top At Least 3 Meter below the Ground Level with 20 mm dia. G.I. Pipe & Funnel for Watering, 1 No. 8 SWG G.I. Wire Earthing Lead etc. with Alternate Layer of Charcoal / Coke and Salt At Least 150 mm Thick Around it.
LASHANI ENTERPRISES
M/s S.S. Refregeration
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid