| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.8 LAccepted-Finance | 1 | Accepted-Finance L1 LOWEST BIDDER | |
| 2 | 2₹3.2 L+₹42,285 (15.1%)Rejected-Finance ADD 5 SARDAR PATEL MARG CIVIL LINES PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 2 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 3 | 3₹3.8 L+₹1.0 L (35.8%)Rejected-Finance | 3 | Rejected-Finance RATES ARE ON HIGHER SIDE |
Tender Value
₹5.4 L
EMD Value
₹5,500
Closing Date
27 May 2021, 5:00 pmClosed
SE ETC UPPTCL AZAMGARH
220KV S/S COLONY HAFIZPUR AZAMGARH
Erection of structure, equipments, cable laying and all other associated work for adding 01 No. 40 MVA 132/33 kV T/F at 132 kV S/s Mehnagar, Azamgarh
2021_UPTCL_585565_1
03/AETC/2021-22
Open Tender
Electrical Works
Item Wise
120 days
AZAMGARH
UTR SLIP OF EMD TENDER FEE PAN CARD GST CERTIFICATE WORK EXPERIENCE etc.
2 documents required · 2 mandatory
₹650
SE ETC UPPCL AZAMGARH
₹5,500
8 Jun 2021
7 May 2021
28 May 2021
7 May 2021
27 May 2021
7 May 2021
7 May 2021 - 27 May 2021
Amount
(A) Erection of main & auxiliary structure latice type ATMS, AXM, BTM etc consisting of coloumn, beam peak, mast etc and auxiliary structure of installation of CTs, PTs, LA etc. The job consists of shifting of all materials from store to site of erection and erection of structuress as per drawing with the help of GI nut & bolts, flat & spring washer with matching the hole, cuttag & mataching of memeber if required, including cost of all men and T&P excluding GI structure Nut & bolts to complete the work. GI structures, nut & bolt and washer will be provided by department free of cost.
(B) Erection of 145 KV Equipments (i) 145 kV SF-6 Circuit breaker
(ii) 145 kV Bus/line Isolator
(iii) Tandom Isolator
(iv) 145 kV Current Tansformer
(v) 145 kV PT
(vi) 145 kV Post Insulator
(vii) 120 kV Lightening arrestor
(viii) 145 kV CT Junction box
(ix) 145 kV PT Junction box
(C) Erection of 33 KV Equipments (i) 33 kV vacume circuit breaker
(ii) 33 kV Isolator
(iii) 33 kV Current Transformer
(iv) 33 kV Lightening arrestor
(v) 33 kV CTJunction box
Stringing of three phase jack bus 132 KV with panther conductor. The work includes cutting & bending of conductor, fixing of bolted type tension/suspension fitting. Hoisting of disc insulators and shifting of material from store site to erection site and all other associated work to complete the Job satisfactorily as per instruction of engineer incharge. (i) 132 kV Jack bus for Transformer and Transfer bay.
(ii) 132 kv making of U Jumpers
Stringing of 132 KV main and transfer busbar with moose conductor, length of span as mentioned below including fittings of tension clamp hoisting of insulator, cutting of conductor, shifting of all materials and all other associated work to complete the job satisfactory as per standard. (a) 132 kV Main bus of 3 Phase (Moose conductor) length 12 meter.
(b)132 Transfer bus of 3 Phase (Moose conductor) lenght 12 meter.
(c) Inteconnection of two section of Main and Transfer bus bar by moose conductor.
Equipments interconnection jumpering with main, transfer jack bus bar. Job include bending of conductor in proper shape tightening with the help of clamps and all other associated work to complete the job. (i) Transformer bay for 132/33 kV side and transfer bay.
(ii) Transformer bay for 132/33 kV side and transfer bay
Laying and termination of following size control cable in trench/Cable trays from control room panel to 132/33 KV switchyard equipments and their junction boxes as per cable schedule including carriage of cable drum from store and all other associated work. (i) 2Cx2.5mm²
(ii) 4Cx2.5mm²
(iii) 6Cx2.5mm²
(iv) 10Cx2.5mm²
(v) Termination of control cable (per termination)
Cutting strengthening bending and laying 700 mm/500 mm below inside ground MS flat for proper earthing of main and Auxiliary structure and equipments including welding with main earth mat and with objects to be earthed, The work include excavation trenches and back filling painting and all other associated work as required to complete the work satisfactorily. M.S. flat will be providing by the contractor free of cost. (i) 75x10 mm
(ii) 50x6 mm
Providing and fixing of phase plate various make Isolator (RYB make of 2.00 mm thick aluminium sheet of size 4" dia covering of 3 M HIP/MDG retro reflected sheet in single phase with all mounting arrangement with GI nut and bolts after opening of old rusted and damaged phase plate.
Providing and fixing of name plate made of 2 mm thick aluminium sheet with covering of 3 HP retro reflective sheeting of size 300 mm x 150 mm plates to be fixed with the help of nuts and bolts on equipments and structures at 132 KV Sub Station.
Making delta earthing of 120 LA by fabrication of 03 Nos 3 mr M.S. round bar (36/40 mm dia) electrode in placeing inside the ground and connecting all 03 Nos electrodes with 75x10 mm MSS. flat filling with charcoal and salt as per standard practice. Painting the joints with black japan paint of good cuality after proper cleaning of joints by wire brush MS round bar will be provided by dept. free of cost.
Safe dismantling of old, running 145 KV C.T.
Dismantling of Auxiliary structures type BCT and ALP
Safe dismantling of old, running l45KV PT
Safe dismantling of old, running l45KV LA
Safe dismantling of 132 KV Lalganj- Mehnagar line from dead-end tower to Sub Station gantry.
Stringing of 132 KV Lalganj- Mehnagar line from dead-end tower to Sub Station gantry work includes hoisting of insulators, fixing of tension fitting , cutting of conductor, jumpering etc. as per requirement.
M/s Aditya Enterprises
M/s. ADITYA TRADING CO., KM-383, RAIDOPUR OFFICERS COLONY, AZAMGARH, U.P.-276001.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .