Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 12 BUMHAMA KUPWARA KUPWARA BUMHAMA KUPWARA KUPWARA JAMMU KASHMIR 193222 | KUPWARA | JAMMU AND KASHMIR | 193222 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.5 L
EMD Value
₹3,080
Closing Date
10 Nov 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant executive Engineer KPDCL Tangmarg
KPDCL Tangmarg
RMShifting of 63 Kva Distribution Transformer at Ringawali under RM UT Capex Budget 2025-26
2025_PDD_292575_2
E-NIT No.SSDT/36 of 2025-26,Dated 18.10.2025
Open Tender
Electrical Works
Turn-key
45 days
Ringawali
Please refer Tender documents.
4 documents required · 4 mandatory
₹115
Treasury Officer
₹3,080
12 Nov 2025
18 Oct 2025
12 Nov 2025
18 Oct 2025
10 Nov 2025
19 Oct 2025
18 Oct 2025 - 19 Oct 2025
Amount
Supply , Transportation and errection of 9MTR long ST Poles (410 SP-33) completely errected in the pit of 1/6th of the pole length including excavation and back filling of the pole pit. (as per REC Standard)
Supply, Transportation and errection of 8MTR long ST Poles (410-SP 15) completely erected in the pit of 1/6th of the pole length including excavation and back filling of the pole pit . (as per REC standard)
Supply and fixing of 185 mm Sq Single Core 1.1 KV Grade , PVC Insulated stranded conductor FRLS Type including Aluminum Thimbles, PG/SL Clamps etc. as per REC standard
Earthing of kVA SubStation--Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover
Supply, Carriage up to site, Installation, testing and Commissioning of danger Plates
Supply, Carriage up to site, Installation, testing and Commissioning of GI Barbed Wire for anti-climbing for substation with clamps
Cement bottoming of S.T poles in 1:2:4 mix 1/6th of the height of pole below the ground and 1ft above the ground cylnerical shape with circular radius 9” from the pole centre) using 40mm crushed stone aggregate mix. As per Drawing 0.48 cum/polePit =( 600x600x1600)& Tappered at the Top. (as per REC standard) for 9 MTR ST Pole
Cement bottoming of S.T poles in 1:2:4 mix 1/6th of the height of pole below the ground and 1ft above the ground cylnerical shape with circular radius 9” from the pole centre) using 40mm crushed stone aggregate mix. As per Drawing 0.40 cum/pole (Pit 600x600x1433.3 mm) for 8 MTR ST Pole
Earthing of Poles Complete by Spike earthing Rod 20mm 2.5mtr long with GI strip 25x3mm (as per REC Standards)
Poviding and Painting of ST Poles with one coat of red oxide t to give an even shade using anti corrosive paint of standard brand (Nerolac/ Asian) paints) including cost of paint along with stamping on poles showing therein name of the firm date, year of instllaiton and the debitable head etc.
Poviding and Painting of ST Poles two coats of aluminum paint to give an even shade using anti corrosive paint of standard brand (Nerolac/ Asian) paints) including cost of paint along with stamping on poles showing therein name of the firm date, year of instllaiton and the debitable head etc.
Supply, Carriage up to site, Installation, testing and Commissioning of GI Channel /Angle/Flat of sizes including clamps
Supply, Carriage up to site, Installation, testing and Commissioning of Galvanised stay set with 50X8mm stay clamp, guy insulator (02nos), anchor plate (200X200X6)mm nut bolts, 02nos turn buckle, 1.8m long, 16mm diameter solid GS stay rod & 7/3, 15mm dia GI stranded wire complete
Supply, Carriage up to site, Installation, testing and Commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn.Type
Supply, Carriage up to site, Installation, testing and Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole,200 Amp, Vertical Type
Supply, Carriage up to site, Installation, testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply, Carriage up to site, Installation, testing and Commissioning of AI Thimbles
Supply and fixing Galvanized Nuts & bolts of sizes
Shfiting of Transformer from existing substation bed /frame to new substation frame and transportation of scrap from site to Divisional Store
Supply, Carriage up to site, Installation, testing and Commissioning of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc.
Pre, during and post execution geo tagged photographic evidence consisting of 5x7 inch photographs in coffee table book (covering each pole/Sub Station)
KHAN AND SONS (BID ID -2635047)
m/s rahmiya electricals (BID ID -2633715)
WAZA ELECTRICALS (BID ID -2618091)
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
BOQ_944181.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .