Sunilkumar K A
Deputy General Manager (Projects and Planning), FACT (Cochin Division), Ambalamedu Ernakulam
Installation of new light fittings, fans etc in safety training room, fire tender bay and board room at FACT-CD, Ambalamedu.
2022_FACT_689179_1
04026/2022-2023/E25433
Limited
Miscellaneous Works
Item Rate
30 days
AMBALAMEDU
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹5,000
Yes
20 Jun 2022
17 May 2022
3 Jun 2022
17 May 2022
2 Jun 2022
17 May 2022
Scope of work The scope of work includes dismantling of all old wiring and electrics in existing training room and fixing of new slim panel surface mounted LED light fittings in safety training hall, fire engine bay and board room. The scope of work also includes supply of light fittings,cutting the Gypsm board to install recess mounting LED lamps, connection and servicing .A sample of light fittings shall be got approved by the Engineer-in Charge before installation.Training hall wiring shall be as per drwg no - CD-FIRE-TRG-04/22
Dismantling the existing fluorescent tube fittings, fans , old wiring , isolator box, and switch board etc. from existing training hall and transported to the scrap yard .
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper wires (red/blue/yellow colours).
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper wire ( Black colour).
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper wire ( Green colour).
Installation of the above items (as per the activity codes CDE-LVRW-02,03&04) for training room: The installation scope shall include drawing of cables through PVC conduits from switch board to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit.
Installation and laying of copper wires for board room LED lamps: The installation scope shall include drawing of cables through PVC conduits from switch board to light fittings and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit.
Installation and commissioning of the PVC conduit: The installation scope shall include fixing of PVC conduits and its accessories to the ceilings of the training class room and neatly clamping at a uniform spacing of 450mm using GI saddles, tagging, drilling holes, minor civil work etc.Suitable sized junction boxes shall be provided at regular intervals. The materials required for the installation such as PVC saddles,screws,nuts, bolts, bends, Tees and junctions etc shall be supplied by the contractor. PVC conduit shall be supplied by FACT free of cost.
Installation and commissioning of the PVC conduit: The installation scope shall include fixing of PVC conduits and its accessories above the existing ceilings of the board room and neatly clamping at a uniform spacing of 450mm using GI saddles, tagging, drilling holes, minor civil work etc.Suitable sized junction boxes shall be provided at regular intervals. The materials required for the installation such as PVC saddles,screws,nuts and bolts junction boxes etc shall be supplied by the contractor.
Supply of 1/2 M type modular GI box with front plate.Make-LEGRAND/elleys or equivalent .
Installation and commissioning of the above(item as per activity code CDE-LVRW-09 ) switch board. The installation scope shall include chipping the wall/pillar and conceal the switch box ,mounting the front plate after fixing the switches/sockets , wiring the switch board, termination of 1.5/2.5 sq.mm multi stranded cables etc.Separate earth shall be provided to the switch board. The materials such as SS screws,PVC/nylon grips for mounting the switch box etc.shall be supplied by the contractor.
Supply of 8M type modular GI box with front plate.Make-LEGRAND/elleys or equivalent .
Installation and commissioning of the above(item as per activity code CDE-LVRW-11) switch board. The installation scope shall include chipping the wall/pillar and conceal the switch box ,mounting the front plate after fixing the switches/sockets , wiring the switch board, termination of 1.5/2.5 sq.mm multi stranded cables etc.Separate earth shall be provided to the switch board. The materials such as SS screws,PVC/nylon grips for mounting the switch box etc.shall be supplied by the contractor.
Supply of 12M type modular GI box with front plate.Make-LEGRAND/elleys or equivalent .
Installation and commissioning of the above(item as per activity code CDE-LVRW-13) switch board. The installation scope shall include chipping the wall/pillar and conceal the switch box ,mounting the front plate after fixing the switches/sockets , wiring the switch board, termination of 1.5/2.5 sq.mm multi stranded cables etc.Separate earth shall be provided to the switch board. The materials such as SS screws,PVC/nylon grips for mounting the switch box etc.shall be supplied by the contractor.
Supply of 3 pin 5/6 amps modular socket (LEGRAND 573470 or equivalent)
Supply of 5/6 amps modular switch( LEGRAND 573400 or equivalent)
Supply of wall mounted fan with Sweep Size = 400 mm, Air Delivery = 65-75 CMM
Installation of wall mounting fan at safety class room as per drawing
Supply of 30W, 300 mm recess mounting type cool day white LED fittings round type with all required accessories for fixing and connecting the fitting to the point. (Phillips (ultra slim plus), Halonix or equivalent) for training and board room.
Installation of the above (item as per activity code CDE-LVRW-19) light fittings suitable for recess mounting with all required accessories for fixing and connecting the fitting to the point for safety training room.
Installation of the above (item as per activity code CDE-LVRW-19) light fittings suitable for recess mounting with all required accessories for fixing and connecting the fitting to the point for board room.
Supply of 15W, 170mm LED TYPE light cool day white fittings round type recess mounting with all required accessories for fixing and connecting the fitting to the point (Phillips (ultra slim plus), Halonix or equivalent) for board room.
Installation of the above (item as per activity code CDE-LVRW-22) light fittings suitable for recess mounting with all required accessories for fixing and connecting the fitting to the point for board room.
Supply of exhaust fan with Louvre,Operation sweep size:200mm Operating Voltage: 230 volts.
Installation of the above (item as per activity code CDE-LVRW-24) with all required accessories.
Supply of casing and capping of size 20 mm
Fixing of the above item (item as per activity code CDE-LVRW-26) in technical office building. All miscellaneous items required to complete the installation shall be supplied by the contractor
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 1.5 sq.mm copper red/blue/yellow wires.
Installation of the above(item as per activity code CDE-LVRW-28) copper wires for exhaust fan. The installation scope shall include drawing of cables through casing and capping from switch board to exhaust fan and its termination.
Supply of 5x2.5 SQ.MM, 1100V,FRLS & ISI marked armoured copper cable
Laying of 5x2.5 sq mm cable through cable trench.The scope of work shall include excavation of cable trench, digging of under ground cable trench of width 300 mm and depth not less than750 mm, laying the cable from old fire engine shed to new shed , and providing country bricks along the cable route and then filling back the cable trench with soil and consolidating it to the original level after laying the cable. The trench wherever crosses the road ,the portion shall be concreted and plastered after soil filling work. The brick shall be supplied by the contractor.
Laying of 5x2.5 sq mm cable through walls. The scope of work shall also include laying of cables through wall/pillars and clamping the cable using 20mm width G.I/Al.strips at an interval not less than 45 cms. The materials such as screws, nuts, bolts ,washers,AL/G.I strips, etc. required for the work shall be supplied by the contractor.
Laying of 5x2.5 sq mm cable through M S structure. Cable shall be clamped using 20x2 mm aluminium clamp. Suitable M S strip (40x20x3 mm) shall be welded in existing structure and painted properly after welding and clamping work using epoxy paint.
Supply and installation of 90-Watt LED Street Light with IP65 Waterproofing, Rustproof, Energy Saving & Durable Flood Light for Outdoor Use, Aluminium Body Cool White 90-Watt LED Light with Wall Mount Clamp.
Supply of MCB switch board with 5 Nos of single pole 10A ,10 kA, classB, 240V MCB
Installation of the above item (item as per activity code CDE-LVRW-35) in new fire engine bay M S structure.
Supply of 3x1.5 SQ.MM, 1100V,FRLS & ISI marked armoured copper cable
Laying of the above (item as per activity code CDE-LVRW-37) 3x1.5 sq mm cable through M S structure from switch board to MCB box. Cable shall be clamped using 20x2 mm aluminium clamp. Suitable M S strip (40x20x3 mm) shall be welded in existing structure and painted properly after welding and clamping work using epoxy paint.
Supply of PVC electrical junction box with dimension 150x150x50 mm .
Installation of the above item (item as per activity code CDE-LVRW-39) for the lighting wiring in new fire engine bay.
Supply of single compression type cable gland suitable for 5x2.5 sq mm copper cable
Installation of above item (item as per activity code CDE-LVRW-41)in MS structure for connecting lamp. All the materials required for commissioning the lighting system shall be brought by the contractor.
PEEJESS ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_725220.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .