Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹31.7 L+₹76,267.25 (2.46%)Rejected-Finance MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹31.9 L+₹90,942.50 (2.94%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹33.3 L+₹2.4 L (7.63%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹38.8 L+₹7.9 L (25.4%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
7 Dec 2020, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR/MAINT OF LT CABLES, PANELS, FEEDER PILLAR BOXES, POLES AND CONNECTED ITEMS AT ARMY AREA BANAR
2020_MES_388908_1
8820/17/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
BANAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Banar
₹76,000
Yes
30 Dec 2020
22 Oct 2020
9 Dec 2020
22 Oct 2020
7 Dec 2020
23 Nov 2020
Amount
Excavation in trenches in hard/soft/loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified and directed .
All as per item No 1 here in befofre but exc 1.5 mtr or part there of in depth beyond the first 1.5 mtr depth upto 3.00 mtr depth complete all as specified and directed by Engr-in-Charge
Returning, filling, in including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed by Engr-in-Charge
Removing excavated surplus soil to a distance not exceeding 50 mrt and depositing where directed at a level not exceeding 1.5 mrts above the starting point complete all as specified and directed by Engr-in-Charge
Material and labour for sand cushioning/sand covering using tibba sand for underground cable protection spread 08 cm under the cable and 15 cm over the cable complete all as specified and directed by Engr-in-Charge. Note :- For the purpose of payment, purned thicknes of sand which comes out 18 cm shall be measured and paid.
Material and labour plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in base of the pole as a foundation or in any similar situation complete all as specified and directed by Engr-in-Charge
Material and labour plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of the pole or in any situation including necessary form work complete all as specified and directed by Engr-in-Charge.
Supply and laying Jodhpur stone slab rough dressses cover 25 to 30 cm in width,minimum 60cm long and 40 to 45mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10mm over underground cables complete all as specified and directed by Engr-in-Charge.
Material and labour for disconnecting power supply from LT ACB of cap 800/1000/1500 Amps for repair works, taking out trolly unit & comoplete servicing of the same through decarbonising, cleaning the male/female isolating contaqcts, lubricating moving part, cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley, checking proper operation of trolly all as directed, inserting trolley inside and tgesting and putting on load compolete all as specified and directed
Supply , fixing and testing straight though heat shrinkable joint with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade and including taking out cable from faulty portion in any situation/position complete all as specified and directed for the following sizes (Excavation, earth work required shall be measured and paid under relevant item of sch).
16-35 Sqmm x 3/3.5 core/4core
50-70 Sqmm x 3/3.5 core
95-120 Sqmm x 3/3.5 core
150-185 Sqmm x 3/3.5 core
240-300 Sqmm x 3/3.5 core
Supply, fixing and testing heat shrinkable end joint with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade and including taking out cable from LT Panels MCCB/ACB or from LT ppole or in any situation/position complete all as specified and directed for the following sizes (Excavation, earth work required shal lbe inclusive in the rate quoted for the item):-
16-35 Sqmm x 3/3.5 core/4core
50-70 Sqmm x 3/3.5 core
95-120 Sqmm x 3/3.5 core
150-185 Sqmm x 3/3.5 core
240-300 Sqmm x 3/3.5 core
Supply and fixing in replacement GI pipe medium grade with necessary accessories/fittings like Tee, bend, socket, elbow or making curved shape by cutting/welding the pipe for cable protection/pole for cable protection with pole or under road crossing or under culvert/nallah crossing of following bore size :-
Cutting the road/hard standings incl excavation in trenches not exceeding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4 type B1 using 20mm graded stone aggregate complete and matching with the surroundings all as directed by Engr-in-Charge
Supply and fixing in replacement of UNSV/Burnt MCCBs with thermal and magnetic release adjustable over load setting 0.8 to 1.0 of in and short circuit setting 0.6 to 1.0 of in fixed in any type of existing LT panel/Feeder pillar etc complete all as directed.
100-125 Amps, 4 pole 415 volts 25 KA
160-200 Amps, 4 pole 415 volts 25 KA
200-250 Amps, 4 pole 415 volts 25 KA
250-320 Amps, 4 pole 415 volts 25 KA
320-400 Amps, 4 pole 415 volts 25 KA
Supply and fixing inreplacement, change over switch on load 4 pole, 415 volts 50 Hz open execution type mounted on existing any type/description of LT Panel/feeder pillar box with necessary minor modification to existing panel including connecting terminals and connection with cable complete all as specified and directed of following size :-
Supply and fixing in replacement of mild steel sliding door bolts plate type, stove enamelled black, with bright bolt not less than 12mm dia, 200mm long bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed on front side door of Lt panel board and all as specified and directed
Material and labour for fixing/fabricating in replacement of 3.15mm thick CRCA sheet painted with existing colour of LT panel and made shape of inner shells and outer shells of panels and making curve/angle to maintain slope of top sheet of panel to make the indoor type to outdoor type with the support of FI 25x3mm thick support, fixing with bullet screws where ever required and all as specified and directed at site by Engr-in-Charge
Material and labour for replacing the heatup/naked cable ends by cutting the naked/heatup portion and reconnect the cable by excavating the loop and making connection tight by replacing the suitable size of heavy duty lugs with new nut bolts and washers and all as specified and directed Note:- (i) Earth work and cable end joints shall be measure and paid under relevant item of sch (ii) Rate quoted are deemed to include for replacement of the cable lugs and nut bolts etc. (iii) Total incoming and outgoing cable ends of each panel shall be measured as a one job
Material and labour for fixing in replacement of heat shrinkable insulated aluminium bus bar with color coding of current rating upto 600 Amp fixing on existing LT panels by making hole, bent to shape or drilling/ grinding the busbar to fix on porcelain/PVC insulators with nut bolts complete all as specified and directed
Material and labour for edging the roughly dressed Jodhpur quarry stone putty of size 25 to 30 cm in width, 60cm long and 40 to 50mm thick, to make edge around the LT panels complete all as specified and directed
Material and labour stone aggregate of size upto 40mm for loose filling around LT panels or under 2/4/6 poles structure including surface dressing and cleaning the vegetation and spraying the herbicide of approved brand one time before spreading the gravel and complete all as specified. Note :- Stone aggregate brought by the contractor shall be measured in stack before use and entered in MB "Not to Abstract".
Labour for cutting and removing grass, vegetation, bushes/shrubs etc from surrounding of 02 pole /4 pole structure and LT/HT panel E/M installations and removing all rubbish and dressing the gravel /soil and spaying the one time herbicide approved brand (Roundup/Noweed) to prevent the further vegetation complete all as specified and directed
Supply and erecting in replacement of prestressed concrete pole 9.0 meter long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level and including dismantling and taking out the damaged/old PCC pole and setting aside within 50 mtr distance and opening the steel light bracket/ cross arms with connected items and street light fitting from old pole and refixing the same on new pole for street light fitting and all as required as site or directed by Engr-in-Charge
Supply, install, testing and commissioning LT feeder pillar box outdoor cubical type, CPRI approved, 3 phase, 4 wire, 415 volts with 200 Amps Aluminium bus bar, IP-54, dust and vermin proof fabricated with CRCA sheet not less than 3.0 mm thick fixed on angle iron frame of size 50x50x6mm duly powder coated, front openable double door hinged with locking arrangements complete with and comprising thte following including necessary PCC platform of suitable size to adjust to Lt panel complete all as specified and directed.(Location:-FAD Perimeter Panel No.31,33,34,43,44 & 45.) (a) Incoming (i) MCCB 4 pole, 125 Amps with thermal and magnetic release, 50Hz 415 Volts, 25 Ka - 1 No (b) Outgoing (i) MCB SPN 50 Amps 230 volts 10 KA - 04 Nos (ii) MCCB 63 Amp 415 volts 4 poles 16 KA -01 No Note :- (I) Cost of PCC platform 50mm thick 1:2:4 type B-1 over 75 mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item (ii) Drawing and make of LT panel shlla be submitted by manufacturer will be approved by Accepting Officer before placing order
Earthing complete with Galvanised steel earth plate of size 60x60cmx6mm thick electrode and 32x 6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No 3 of SSR Part-I connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI protection pipe for earth strip in ground etc. all as required at site for complete earthing) Note :- Testing of earthing shall be carried out after completion of earthing. Payment for earthing shall be admissible after satisfactory test result only.
Material and labour for scraping the old rusted surface of LT panel and making smooth surface by filling the cavities with metal based primer and painting on old surface of LT panels/ feeder pillars 2 coats of super enamel paint with spraygun including writing of feeder pillar numbers in appropriate size of letters all as directed by Engr-in-Charge
Taking down old unserviceable LT UG cable and supply, laying, testing and commissioning in replacement of LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 ({Part-1) marked, laid in trenches/ducts/fixed on poles/walls/laid under roads/ paths/drain/culverts or encased in GI pipe compete alls as specified and directed for the size of cable 16 Sqmm 4 core
All as per ser item No 29 hereinbefore but of size 10 Sqmm 2 core
All as per ser item No 29 hereinbefore but of size 25 Sqmm 4 core
All as per ser item No 29 hereinbefore but of size 35 Sqmm 3.5 core
All as per ser item No 29 hereinbefore but of size 50 Sqmm 3.5 core
All as per ser item No 29 hereinbefore but of size 70 Sqmm 3.5 core
All as per ser item No 29 hereinbefore but of size 95 Sqmm 3.5 core
All as per ser item No 29 hereinbefore but of size 120 Sqmm 3.5 core Note for srl item No 29 to 36 : laying of cable shall be in domestic area as well as inside Depot/unit area. No claim on the account shall be entertained.
Restretching aluminium conductor or GI wire on existing over head lines without removing including unbinding from insulator and rebinding to insulator using aluminium binding wire, connections of incoming and outgoing cables, binding with spacers where required and trimming the tree branches with clearance of 3 mtr around of the LT OH line, complete all as specified Note :- For measurement length of each conductor shall be taken separately however GI wire shall be included with conductor length.
Trimming and cutting of tree branches coming across LT over head line, cleaning around 3m the LT line and disposal of branches/bushes to a distance upto 50m and cleaning the site complete all as directed. Note :-(i) Length of span shall be 45 to 50m (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible (iii) Proper shut down will be taken from department and T&P will be provided by contractor
Material and labour for taking out the unserviceable street light fittings mounted on LT PCC poles with mounting brackets including clamps by descrewing/cutting the bracing, nut bolts complete all as specified and directed by Engr-in-Charge
Material and labour for taking out the old unserviceable/ damaged LT/HT PCC poles of any type by demolishing the foundation or citing the pole from ground level and shifting the same by loading on vehicle from inside to outside of Depot area 3Km away from the Depot perimeter wall and laying the poles at lowland area as per direction of Engr-in-Charge
Taking out from trenches or wall / pole or pipe cable LT 1100 volts grade heavy duty, armoured with steel strip of wire, with stranded aluminium conductor of any size upto 25 Sqqmm, any core, for rectification of faults or replacement. Seggregating serviceable cable and unserviceable length by meggering or any other suitable and recommended method. Removing unserviceable cable from site and keeping aside serviceable for reuse at same laocation or any other location under AGE E/M all as required at site or directed (Earth work will be measured and paid separately under respective item)
All as per srl item 41 here in above but of size 35 Sqmm to 95 Sqmm
All as per srl item 41 here in above but of size 120 Sqmm to 185 Sqmm
All as per srl item 41 here in above but of size 240 Sqmm to 400 Sqmm
Laying only in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty, armoured with aluminium conductor of any size upto 25 Sqmm any core (Serviceable cables retrieved against srl item 41 above will be used)
All as per Srl item 45 here in above but of size 35 Sqmm to 95 Sqmm (Serviceable cables retrieved against srl item 42 above will be used)
All as per Srl item 45 here in above but of size 120 Sqmm to 185Sqmm (Serviceable cables retrieved against srl item 43 above will be used)
All as per Srl item 45 here in above but of size 240 Sqmm to 400 Sqmm (Serviceable cables retrieved against srl item 44 above will be used)
Taking down the old unserviceable LT OH line ACSR conductor of any size and all as specified and directed by Engr-in-charge
Taking down the pin/disc/shackle insulator of any size from pole of 9 mtr long and all as specified and directed
Material and labour for ACSR conductor in replacement of any size drawn straight horizontal on over head lines on poles including binding with insulatiors using aluminium binding wire , jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed
Material and labour shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed
Material and labour for pin insulators 75mm height and 90mm dia size porcelain, vitreous, white brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed
Taking down/dismantling the crossarms of any size and anyh description from poles of any description
Supply and fixing in replacement of cross arms, brancings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolt. In any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint and all as specified and directed
Supply and fixing Radium tape 40-50 mm width on the electrical items complete all as specified and directed by Engr-in-Charge
BHARAT NIRMAN INFRASTRUCTURE COMPANY
Surendra Singh
M/S JAGDAMBA ENTERPRISES
M/s Vishaka Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .