ABSTRACT OF COST
Name of the work: Constrcution of Community Center for SAIL,GUA ORE MINES
S.H. No. Description of Sub-Head DSR Amount (Rs) NS Amount (Rs)
1 Civil Finshing Works : 2,98,44,940 55,19,940
2 External works 1,24,12,918
3 Plumbing Works : 9,49,733 8,51,678
4 Fire fighting Works : 2,76,012 47,580
5 Electrical Works : 27,69,191 17,58,783
After adding cost index @ 10% as per CPWD
office memorandum 34(1)/cost index/ Included in BOQ
ADG(patna)/ 2024/621(H) dated 25.07.2024
Modified Estimated Cost after using Correction
Included in BOQ
factor on DSR 2023 on account of GST @0.973 -
W TOTAL ESTIMATED COST: 5,44,30,775
Digitally signed by PRIYA
ABSTRACT OF COST
Name of the work : Constrcution of Community Center for SAIL, Gua Ore Mines
Sl. No. Description of Sub-Head DSR Amount (Rs) Non DSR Amount
A. Internal Civil Works
1 Earth Work : 1422675.00
2 Concrete Work : 1404104.00
3 Reinforced Cement Concrete : 5407400.00
4 Masonry Work : 2225939.00
5 Cladding Work : 553652.00
6 Wood and P.V.C. Work : 708147.00
7 Steel Work : 9202873.00
8 Flooring : 3460076.00
10 Finishing : 1617989.00
11 Aluminium Work : 347757.00
12 New Technologies and Materials : 81642.00
13 Non Schedule Items 5519940.40
B. External Civil Works
1 Earthwork 1902722.00
2 Concrete Work 1088209.00
3 RCC Concreting Works 5736148.00
4 Masonary works 440159.00
5 Steel works 957185.00
6 Finishing works 244831.00
7 Road Works 1405418.00
8 Precast Boundary works 638246.00
Digitally signed by PRIYA
Name of the work : Constrcution of Community Center for SAIL, Gua Ore
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
Sub-Head : Earth Work
2.6 Earth work in excavation by mechanical means
(Hydraulic excavator) / manual means over areas
(exceeding 30cm in depth, 1.5m in width as well as
10 sqm on plan) including getting out and disposal
of excavated earth, lead up to 50m and lift up to
1.5m,as directed by Engineer-in-Charge.
2.7 Earth work in excavation by mechanical means -
(Hydraulic excavator) / manual means over areas
(exceeding 30 cm in depth, 1.5m in width as well as
10 sqm on plan) including getting out and disposal
of excavated earth, lead up to 50 m and lift up to
1.5m, as directed by Engineer-in-Charge.
3 2.25 Filling available excavated earth (excluding rock) in 425.00 Cum 209.78 89156.00
trenches, plinth, sides of foundations etc. in layers
not exceeding 20cm in depth, consolidating each
deposited layer by ramming and watering, lead up
to 50 m and lift up to 1.5 m.
4 2.25A Excavating, supplying and filling of local earth 250.00 Cum 749.75 187436.00
(including royalty) by mechanical transport up to a
lead of 5 km, also including ramming and watering
of the earth in layers not exceeding 20 cm in
trenches, plinth, sides of foundation etc., complete.
2.26 Extra for every additional lift of 1.5 m or part -
thereof in excavation /banking excavated or stacked
6 2.26.2 Ordinary or hard rock. 15.00 Cum 243.39 3651.00
7 2.27 Supplying and filling in plinth with sand under 185.00 Cum 2,273.05 420514.00
floors, including watering, ramming, consolidating
and dressing complete.
2.34 Supplying chemical emulsion in sealed containers -
including delivery as specified.
8 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 500.00 Ltr 251.25 125626.00
2.35 Diluting and injecting chemical emulsion for PRE -
CONSTRUCTIONAL anti- termite treatment
(excluding the cost of chemical emulsion) :
2.35.3 Treatment of soil under existing floors using -
chemical emulsion @ one litre per hole, 300 mm
apart including drilling 12 mm diameter holes and
plugging with cement mortar 1 :2 (1 cement : 2
Coarse sand) to match the existing floor :
9 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% 1350.00 Sqm 331.85 447993.00
Total of the Sub-Head - Earth Work : - 1422675.00
Sub-Head : Concrete Work -
4.1 Providing and laying in position cement concrete of -
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
10 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived 75.00 Cum 7,290.88 546816.00
from natural sources : 8 graded stone aggregate 40
mm nominal size derived from natural sources).
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
11 4.11 Providing and laying damp-proof course 50mm 40.00 Sqm 530.60 21224.00
thick with cement concrete 1:2:4 (1 cement : 2
coarse sand (zone-III) derived from natural sources :
4 graded stone aggregate 20mm nominal size
derived from natural sources).
12 4.12 Extra for providing and mixing water proofing 15.00 units 19.43 291.00
material in cement concrete work in doses by
weight of cement as per manufacturer’s
13 4.13 Providing and applying a coat of residual petroleum 40.00 Sqm 156.42 6257.00
bitumen of grade of VG-10 of approved quality
using 1.7 kg per square metre on damp proof
course after cleaning the surface with brushes and
finally with a piece of cloth lightly soaked in
14 4.17 Making plinth protection 50mm thick of cement 150.00 Sqm 801.98 120296.00
concrete 1:3:6 (1 cement : 3 coarse sand (zone-III)
derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from natural
sources) over 75mm thick bed of dry brick ballast 40
mm nominal size, well rammed and consolidated
and grouted with fine sand, including necessary
excavation leveling & dressing & finishing the top
4.20 Providing and laying in position ready mixed or site -
batched design mix cement concrete for plain
cement concrete work; using coarse aggregate and
fine aggregate derived from natural sources,
Portland Pozzolana/Ordinary Portland/Portland Slag
cement, admixtures in recommended proportions
as per IS : 9103 to accelerate/ retard setting of
concrete, to improve durability and workability
without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all
leads; but excluding the cost of centering,
shuttering and finishing as per direction of the
Engineer-in-charge; for the following grades of
Note : Extra cement upto 10% of the minimum -
specified cement content in design mix shall be
payable separately. In case the cement content in
design mix is more than 110% of the minimum
specified cement content, the contractor shall have
discretion to either re-design the mix or bear the
cost of extra cement.
4.20.1 All works up to plinth level: -
15 4.20.1.1 Concrete of M-10 grade with minimum cement 75.00 Cum 9,456.26 709220.00
content of 220 kg/cum.
Total of the Sub-Head - Concrete Work : - 1404104.00
Sub-Head : Reinforced Cement Concrete -
16 5.3 Reinforced cement concrete work in beams, 10.00 Cum 12,314.34 123143.00
suspended floors, roofs having slope up to 15°
landings, balconies, shelves, chajjas, lintels, bands,
plain window sills, staircases and spiral stair cases
above plinth level up to floor five level, excluding
the cost of centering, shuttering, finishing and
reinforcement with 1:1.5:3 (1 cement : 1.5 coarse
sand(zone-III)derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived
from natural sources).
5.9 Centering and shuttering including strutting, -
propping etc. and removal of form for :
17 5.9.1 Foundations, footings, bases of columns, etc. for 150.00 Sqm 419.72 62958.00
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
18 5.9.2 Walls (any thickness) including attached pilasters, Sqm 901.73
butteresses, plinth and string courses etc.
19 5.9.4 Shelves (Cast in situ) 10.00 Sqm 992.44 9924.00
20 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts 150.00 Sqm 1,028.88 154332.00
21 5.9.21 Lintels, beams, plinth beams, girders, bressumers 375.00 Sqm 901.14 337927.00
and cantilevers with water proof ply 12 mm thick
5.22 Steel reinforcement for R.C.C. work including -
straightening, cutting, bending, placing in position
and binding all complete upto plinth level.
22 5.22.6 Thermo-Mechanically Treated bars of grade Fe- 19000.00 Kg 115.43 2193205.00
5.22A Steel reinforcement for R.C.C. work including -
straightening, cutting, bending, placing in position
and binding all complete above plinth level.
23 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- 5000.00 Kg 115.43 577159.00
24 5.30 Add for plaster drip course/ groove in plastered 50.00 m 83.91 4196.00
surface or moulding to R.C.C. projections
5.33 Providing and laying in position ready mixed or site -
batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and
fine aggregate derived from natural sources,
Portland Pozzolana/ Ordinary Portland/ Portland
Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate/ retard
setting of concrete, to improve durability and
workability without impairing strength; including
pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of
centering, shuttering, finishing and reinforcement
as per direction of the engineer-in-charge; for the
following grades of concrete.
Note: Extra cement up to 10% of the minimum -
specified cement content in design mix shall be
payable separately. In case the cement content in
design mix is more than 110% of the specified
minimum cement content, the contractor shall have
discretion to either re-design the mix or bear the
cost of extra cement
5.33.1 All works upto plinth level -
25 5.33.1.1 Concrete of M25 grade with minimum cement 135.00 Cum 10,172.93 1373346.00
content of 330 kg /cum
26 5.33.1.2 Concrete of M30 grade with minimum cement 20.00 Cum 10,334.50 206690.00
content of 350 kg /cum
5.33.2 All works above plinth level upto floor V level -
27 5.33.2.1 Concrete of M25 grade with minimum cement 25.00 Cum 10,553.59 263840.00
content of 330 kg /cum
28 5.33.2.2 Concrete of M30 grade with minimum cement 5.00 Cum 10,715.15 53576.00
content of 350 kg /cum
29 5.35 Add for using extra cement in the items of design 60.00 Qtl 785.07 47104.00
mix over and above the specified cement content
Total of the Sub-Head - Reinforced Cement - 5407400.00
Sub-HeadConcrete : Work
6.1 Brick work with common burnt clay F.P.S. (non -
modular) bricks of class designation 7.5 in
foundation and plinth in:
30 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 65.00 Cum 7,633.65 496187.00
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
6.4 Brick work with common burnt clay F.P.S. (non -
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level
in all shapes and sizes in :
31 6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 150.00 Cum 9,746.10 1461915.00
32 6.5 Extra for brick work / AAC block masonry / Tile brick Cum 181.36
masonry in superstructure above floor V level, for
each four floors or part thereof by mechanical
6.12 Half brick masonry with common burnt clay F.P.S. -
(non modular) bricks of class designation 7.5 in
foundations and plinth in :
33 6.12.2 Cement mortar 1:4 (1 cement : 4 coarse sand) 5.00 Sqm 968.68 4843.00
6.13 Half brick masonry with common burnt clay F.P.S. -
(non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level.
34 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) 200.00 Sqm 1,202.80 240561.00
35 6.15 Extra for providing and placing in position 2 Nos 200.00 Sqm 112.17 22433.00
6mm dia. M.S. bars at every third course of half
brick masonry.ird course of half brick masonry.
Total of the Sub-Head - Masonry Work : - 2225939.00
Sub-Head : Cladding Work -
8.2 Providing and fixing 18 mm thick gang saw cut, -
mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity counters,
window sills, facias and similar locations of required
size, approved shade, colour and texture laid over
20 mm thick base cement mortar 1:4 (1 cement : 4
coarse sand), joints treated with white cement,
mixed with matching pigment, epoxy touch ups,
including rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at all
8.2.2 Granite stone slab colour black, Cherry/Ruby red -
8.2.3 Granite stone slab all colour and texture except -
black, Cherry/ Ruby red
8.3 Providing edge moulding to 18 mm thick marble -
stone counters, Vanities etc., including machine
polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-in-
41 8.4 Extra for fixing marble /granite stone, over and 20.00 m 608.52 12170.00
above corresponding basic item, in facia and drops
of width upto 150 mm with epoxy resin based
adhesive, including cleaning etc. complete.
42 8.5 Extra for providing opening of required size & shape 10.00 No. 1,047.50 10475.00
for wash basin/kitchen sink in kitchen platform,
vanity counter and similar location in marble/
Granite/ stone work, including necessary holes for
pillar taps etc. including moulding, rubbing and
polishing of cut edges etc. complete
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
43 8.31 Providing and fixing Ist quality ceramic glazed wall 310.00 Sqm 1,357.09 420697.00
tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-
Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement :
3 coarse sand) and jointing with grey cement slurry
@ 3.3kg per sqm, including pointing in white
cement mixed with pigment of matching shade
Total of the Sub-Head - Cladding Work : - 553652.00
Sub-Head : Wood and P.V.C. Work -
9.1 Providing wood work in frames of doors, windows, -
clerestory windows and other frames, wrought
framed and fixed in position with hold fast lugs or
with dash fasteners of required dia & length (hold
fast lugs or dash fastener shall be paid for
9.7 Providing and fixing panelling or panelling and -
glazing in panelled or panelled and glazed shutters
for doors, windows and clerestory windows (Area of
opening for panel inserts excluding portion inside
grooves or rebates to be measured). Panelling for
panelled or panelled and glazed shutters 25 mm to
9.7.7 Float glass panes -
45 9.7.7.2 5.5 mm thick glass panes (weight not less than 1.00 Sqm 2,783.26 2783.00
9.21 Providing and fixing ISI marked flush door shutters -
conforming to IS : 2202 (Part I) non-decorative type,
core of block board construction with frame of 1st
class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and
face veneers on both faces of shutters:
46 9.21.1 35 mm thick including ISI marked Stainless Steel 65.00 Sqm 2,560.85 166455.00
butt hinges with necessary screws
47 9.23 Extra for providing lipping with 2nd class teak wood 65.00 Sqm 494.85 32165.00
battens 25 mm minimum depth on all edges of flush
door shutters (over all area of door shutter to be
9.24 Extra for providing vision panel not exceeding 0.1 -
sqm in all type of flush doors (cost of glass
excluded) (overall area of door shutter to be
48 9.24.1 Rectangular or square. 25.00 Sqm 213.15 5329.00
9.40 Providing and fixing wooden moulded beading to -
door and window frames with iron screws, plugs
and priming coat on unexposed surface etc.
9.40.1 2nd class teak wood -
9.74 Providing and fixing bright finished brass tower -
bolts (barrel type) with necessary screws etc.
9.75 Providing and fixing bright finished brass door latch -
with necessary screws etc. complete :
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
53 9.76 Providing and fixing bright finished brass 100 mm 25.00 No. 914.73 22868.00
mortice latch and lock with 6 levers and a pair of
lever handles of approved quality with necessary
screws etc. complete.
54 9.82 Providing and fixing bright finished brass hanging 25.00 No. 130.20 3255.00
type floor door stopper with necessary screws, etc.
9.127 Providing & Fixing decorative high pressure -
laminated sheet of plain / wood grain in gloss / matt
/ suede finish with high density protective surface
layer and reverse side of adhesive bonding quality
conforming to IS : 2046 Type S, including cost of
adhesive of approved quality.
Total of the Sub-Head - Wood And P.V.C Work : - 708147.00
Sub-Head : Steel Work -
56 10.2 Structural steel work riveted, bolted or welded in 57000.00 Kg 143.10 8156649.00
built up sections, trusses and framed work,
including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer all
57 10.19 Providing and fixing mild steel round holding down 1000.00 Kg 104.03 104033.00
bolts with nuts and washer plates complete.
10.25 Steel work welded in built up sections/ framed -
work, including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer using structural steel etc. as required.
58 10.25.2 In gratings, frames, guard bar, ladder, railings, 300.00 Kg 184.73 55420.00
brackets, gates and similar works.
10.27 Providing and fixing carbon steel galvanised -
(minimum coating 5 micron) dash fastener of 10
mm dia double threaded 6.8 grade (yield strength
480 N/mm2), counter sunk head, comprising of 10
mm dia polyamide PA 6 grade sleeve, including
drilling of hole in frame , concrete/ masonry, etc. as
per direction of Engineer-in-charge.
60 10.28 Providing and fixing stainless steel ( Grade 304) 1000.00 Kg 826.70 826700.00
railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and
making curvature (wherever required) and fitting
the same with necessary stainless steel nuts and
bolts complete, i/c fixing the railing with necessary
accessories & stainless steel dash fasteners ,
stainless steel bolts etc., of required size, on the top
of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in charge,
(for payment purpose only weight of stainless steel
members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.).
Total of the Sub-Head - Steel Work : - 9202873.00
Sub-Head : Flooring -
11.26 Kota stone slab flooring over 20 mm (average) thick -
base laid over and jointed with grey cement slurry
mixed with pigment to match the shade of the slab
including rubbing and polishing complete with base
of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
62 11.27 Kota stone slabs 20 mm thick in risers of steps, 250.00 Sqm 2,520.24 630059.00
skirting, dado and pillars laid on 12 mm (average)
thick cement mortar 1:3 (1 cement 3 coarse sand)
and jointed with grey cement slurry mixed with
pigment to match the shade of the slabs, including
rubbing and polishing complete.
63 11.31 Extra for pre finished nosing in treads of steps of 75.00 m 204.86 15364.00
Kota stone/ sand stone slab.
64 11.32 Extra for Kota stone/ sand stone in treads of steps 35.00 Sqm 47.25 1654.00
and risers using single length up to 1.05 metre .
11.41A Providing and laying Vitrified tiles in floor in -
different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade, laid
on 20 mm thick cement mortar 1:4 (1 cement: 4
coarse sand) jointing with grey cement slurry @3.3
kg/sqm including grouting the joints with white
cement and matching pigments etc. The tiles must
be cut with the zero chipping diamond cutter only .
Laying of tiles will be done with the notch trowel,
plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently
11.41A.1 Double charge vitrified tile polished finish of size -
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size -
11.46 Providing and laying Vitrified tiles in different sizes -
(thickness to be specified by manufacturer) with
water absorption less than 0.08 % and conforming
to I.S. 15622, of approved make in all colours &
shade in skirting, riser of steps, over 12 mm thick
bed of cement mortar 1:3 (1cement: 3 coarse sand),
jointing with grey cement slurry @ 3.3kg/sqm
including grouting the joint with white cement &
matching pigments etc. complete.
Total of the Sub-Head - Flooring : - 3460076.00
Sub-Head : Roofing -
68 12.34 Providing and fixing thermal insulation of ceiling 2000.00 Sqm 752.47 1504949.00
(under deck insulation) with Resin Bonded Fibre
glass wool conforming to IS : 8183, density 24
kg/m3, 50 mm thick, wrapped in 200G Virgin
Polythene bags, fixed to ceiling with metallic cleats
(50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm
x 24 gauge wire mesh, for top most ceiling of
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
12.45 Providing and fixing false ceiling at all height -
including providing and fixing of frame work made
of special sections, power pressed from M.S. sheets
and galvanized with zinc coating of 120 gms/sqm
(both side inclusive) as per IS : 277 and consisting of
angle cleats of size 25 mm wide x 1.6 mm thick with
flanges of 27 mm and 37 mm, at 1200 mm centre to
centre, one flange fixed to the ceiling with dash
fastener 12.5 mm dia x 50 mm long with 6 mm dia
bolts, other flange of cleat fixed to the angle
hangers of 25x10x0.50 mm of required length with
nuts & bolts of required size and other end of angle
hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200 mm
centre to centre, to which the ceiling section 0.5
mm thick bottom wedge of 80 mm with tapered
flanges of 26 mm each having lips of 10.5 mm, at
450 mm centre to centre,
shall be fixed in a direction perpendicular to G.I. -
intermediate channel with connecting clips made
out of 2.64 mm dia x 230 mm long G.I. wire at every
junction, including fixing perimeter channels 0.5
mm thick 27 mm high having flanges of 20 mm and
30 mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm
centre, with 25mm long dry wall screws @ 230 mm
interval, including fixing of gypsum board to ceiling
section and perimeter channel with the help of dry
wall screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of
tapered and square edges of the board with
recommended jointing compound , jointing tapes ,
finishing with jointing compound in 3 layers
covering upto 150 mm on both sides of joint and
two coats of primer suitable for board, all as per
manufacturer's specification and also including the
cost of making openings for light fittings, grills,
diffusers, cutouts made with frame of perimeter
channels suitably fixed, all complete as per
drawings, specification and direction of the
Engineer in Charge but excluding the cost of
painting with :
69 12.45.1 12.5 mm thick tapered edge gypsum plain board 75.00 Sqm 1,451.11 108833.00
conforming to IS: 2095- (Part I) : 2011 (Board with
BIS certification marks)
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
70 12.50 Providing and fixing precoated galvanised iron 2000.00 Sqm 790.58 1581154.00
profile sheets (size, shape and pitch of corrugation
as approved by Engineer-in-Charge) of total coated
thickness 0.50mm (base metal of minimum 0.45mm
thickness with total coating thickness of 0.05mm)
with zinc coating 120 grams per sqm as per IS:277,
in 240 mpa steel grade, 5-7 microns epoxy primer
on both side of the sheet and polyester top coat 15-
18 microns. Sheet should have protective guard film
of 25 microns minimum to avoid scratches during
transportation and should be supplied in single
length upto 12 metre or as desired by Engineer-in-
charge. The sheet shall be fixed using self drilling
/self tapping screws of size (5.5x 55 mm) with
EPDM seal, complete upto any pitch in horizontal/
vertical or curved surfaces, excluding the cost of
purlins, rafters and trusses and including cutting to
size and shape wherever required.
12.51 Providing and fixing precoated galvanised steel -
sheet roofing accessories of total coated thickness
0.50mm (base metal of minimum 0.45mm thickness
with total coating thickness of 0.05mm) with Zinc
coating 120 grams per sqm as per IS: 277, in 240
mpa steel grade, 5-7 microns epoxy primer on both
side of the sheet and polyester top coat 15-18
microns using self drilling/ self tapping screws
72 12.51.2 Flashings/ Aprons.( Upto 600 mm) 25.00 m 519.74 12993.00
Total of the Sub-Head - Roofing : - 3412686.00
Sub-Head : Finishing -
13.1 12 mm cement plaster of mix : -
13.2 15 mm cement plaster on the rough side of single or -
half brick wall of mix :
78 13.11 18 mm cement plaster in two coats under layer 12 500.00 Sqm 555.00 277502.00
mm thick cement plaster 1:5 (1 cement: 5 coarse
sand) finished with a top layer 6mm thick cement
plaster 1:6 (1 cement: 6 fine sand).
13.16 6 mm cement plaster of mix : -
80 13.26 Providing and applying plaster of paris putty of 2 737.50 Sqm 281.17 207361.00
mm thickness over plastered surface to prepare the
surface even and smooth complete.
13.45 Finishing walls with textured exterior paint of -
required shade :
81 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 500.00 Sqm 239.32 119660.00
sqm) over and including priming coat of exterior
primer applied @2.20kg/10 sqm.
13.61 Painting with synthetic enamel paint of approved -
brand and manufacture to give an even shade :
82 13.61.1 Two or more coats on new work. 2000.00 Sqm 166.86 333720.00
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
13.83 Wall painting with premium acrylic emulsion paint -
of interior grade, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre. of
approved brand and manufacture, including
applying additional coats wherever required to
achieve even shade and colour.
Total of the Sub-Head - Finishing : - 1617989.00
Sub-Head : Aluminium Work -
21.1 Providing and fixing aluminium work for doors, -
windows, ventilators and partitions with extruded
built up standard tubular sections/appropriate Z
sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM
rubber/neoprene gasket etc. Aluminium sections
shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing /
paneling, C.P. brass/ stainless steel screws, all
complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing, paneling
and dash fasteners to be paid for separately) :
21.1.1 For fixed portion -
84 21.1.1.2 Powder coated aluminium (minimum thickness of 75.00 Kg 568.22 42617.00
powder coating 50 micron)
21.1.2 For shutters of doors, windows & ventilators -
including providing and fixing hinges/ pivots and
making provision for fixing of fittings wherever
required including the cost of EPDM rubber /
neoprene gasket required (Fittings shall be paid for
85 21.1.2.2 Powder coated aluminium (minimum thickness of 250.00 Kg 679.05 169763.00
powder coating 50 micron)
21.3 Providing and fixing glazing in aluminium door, -
window, ventilator shutters and partitions etc. with
EPDM rubber / neoprene gasket etc. complete as
per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap
beading shall be paid in basic item):
86 21.3.3 With float glass panes of 8 mm thickness (weight 60.00 Sqm 1,803.88 108233.00
not less than 20 kg/sqm)
21.8 Filling the gap in between aluminium frame & -
adjacent RCC/ Brick/ Stone work by providing
weather silicon sealant over backer rod of approved
quality as per architectural drawings and direction
of Engineer-in-charge complete.
87 21.8.1 Upto 5mm depth and 5 mm width 125.00 m 103.55 12944.00
21.11 Providing and fixing stainless steel (SS 304 grade) -
adjustable friction windows stays of approved
quality with necessary stainless steel screws etc. to
the side hung windows as per direction of Engineer-
in-charge complete.
21.15 Providing and fixing aluminium casement windows -
fastener of required length for aluminium windows
with necessary screws etc. complete.
89 21.15.2 Powder coated minimum thickness 50 micron 30.00 No. 104.84 3145.00
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
Total of the Sub-Head - Aluminium Work : - 347757.00
Sub-Head : New Technologies and Materials -
26.27 Providing and fixing mineral fibre false ceiling tiles -
at all heights of size 595X595mm of approved
texture, design and pattern. The tiles should have
Humidity Resistance (RH) of 99%, Light Reflectance
> 85%, Thermal Conductivity k = 0.052 - 0.057 w/m
K, Fire Performance as per (BS 476 pt - 6 &7)in true
horizontal level suspended on interlocking T-Grid of
hot dipped all round galvanized iron section of 0.33
mm thick (galvanized @120 gsm) comprising of
main T runners of 15x32 mm of length 3000 mm,
cross T of size 15x32mm of length 1200 mm and
secondary intermediate cross T of size 15x32 mm of
length 600 mm to form grid module of size 600x600
mm suspended from ceiling using galvanized mild
steel item (galvanised @ 80 gsm) 50 mm long 8mm
outer diameter M-6 dash fasteners, 6 mm diameter
fully threaded hanger rod up to 1000 mm length
and L-shape level adjuster of size 85x25x2 mm,
spaced at 1200 mm centre to centre along main ‘T’. -
The system should rest on periphery walls
/partitions with the help of GI perimeter wall angle
of size 24x24X3000 mm made of 0.40 mm thick
sheet, to be fixed to the wall with help of plastic
rawl plug at 450 mm centre to centre & 40 mm long
dry wall S.S. screws. The exposed bottom portion of
all T-sections used in false ceiling support system
shall be pre-painted with polyester baked paint, for
all heights. The work shall be carried out as per
specifications, drawings and as per directions of the
engineer-in charge.
90 26.27.1 With 16 mm thick beveled tegular mineral fibre Sqm 2,497.65
false ceiling tile (NRC 0.55 to 0.6)
91 26.65 Providing and fixing roofing consist of 0.8 mm thick 50.00 Sqm 1,632.85 81642.00
galvanized steel deck sheet confirming to IS
277:1992 used as permanent shuttering over which
MS wire mesh 3mm laid at 100x100 mm grid
including edge trim covered with concrete. This
metal deck will be supported on structural steel
beam with shear studs. (Structural steel like Beam,
column, joists etc. & concrete of different grade as
per design will be paid separately).
Total of the Sub-Head - New Technologies And - 81642.00
Sub-Head : Non Schedule Items -
1 Providing and fixing 18 mm thick gang saw cut, -
mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity counters,
window sills, facias and similar locations of required
size,approved shade, colour and texture laid with
eopxy resin based special adhesive, epoxy touch
ups, including rubbing, curing, moulding and
polishing to edges to give high gloss finish etc.
complete at all levels.
Granite stone slab colour black, Cherry/Ruby red -
92 1.1 Area of slab upto 0.50 sqm 1.50 Sqm 5,718.00 8,577.00
93 1.2 Area of slab over 0.50 sqm 1.50 Sqm 5,441.00 8,162.00
2 Granite stone slab all colour and texture except -
black, Cherry/ Ruby red
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
94 2.1 Area of slab upto 0.50 sqm 1.50 Sqm 4,475.00 6,713.00
95 2.2 Area of slab over 0.50 sqm 1.50 Sqm 4,153.00 6,230.00
3 Providing and fixing Fully Insulated Wooden -
Acoustic door (Navair or equivalent) at all levels
from ISO 9001:2015 certified Manufacturer . The
door must carry the Batch plate for offered door
details. Door frame shall be Single rebate Navair
make profile of section 140 x 90 mm made out of
Ivory Coast ( 2nd Class ) with factory made groove
of suitable size so as to accomodate Fire & smoke
seal of size 20x4mm of SEALz MAKE. The frame
must be primed with Fire retardant primer FR880
Wooden shutter must be of 77mm thickness -
finished with commercial ply on both faces. The
Shutter may be provided with 6mm thick
commercial ply on both faces which may be pasted
with 1mm thick laminate and both these items may
be replaced with teak veneer . Laminate and veneer
payable in extra item . The composite thickness of
the core insulation will be 65mm thick consists of
calcium Silicate boards and treated wool Insulation
material . The shutter should be provided with heat
activated intumescent fire seal strip of size 20mm x
4 mm mounted in the suitable grooves all three
sides except bottom provided on Exposed wooden
96 3.1 Door shutter provided with commercial ply on both 10.00 SQM 28,595.00 2,85,950.00
faces with 1mm Thick Regular SF grade Factory
pasted Laminate on both faces and Main frame
made out of hardwood frame. Frame primed with
Fire retardant primer.
ACOUSTIC SEAL SET TO ACHIEVE db DROP DOWN -
PROPERTIES BETWEEN 30-32db
97 4 Acoustic Seal Set for Door :- 4.00 Set 17,072.00 68,288.00
A) Perimeter seal IS 1212 of Becker Fire Solutions
B) Mortise Type Drop Down Seal- RP8Si of
Raven/Becker Fire Solutions make
C) Astragal Seal for meeting point of Double Leaf
Door- RP16Si of Raven/ Becker Fire Solutions make
To achieve 35-38 db drop down properties an extra -
exposed perimeter seal RP78Si of Raven / Becker
Fire Solutions make can be provided on peremeter
98 4.1 Supply & fixing of SS Ball Bearing Hinges of size 100 30.00 Each 640.00 19,200.00
x 89 x 3mm complet with SS Screws of BB1753
Becker Fire Soloutions / DORMA 3090F / GEZE
99 5 Supply & fixing of anchor fastners of HILTI / FISHER/ 48.00 Each 121.00 5,808.00
Equvalent of M10X160mm length.
100 6 Supply & fixing of door closers of BLC-605 EN 3-6 6.00 Each 12,092.00 72,552.00
Becker Fire Soloutions/ TS-89 DORMA / GEZE TS
2000 Series Make.
101 7 Supply and Filling the gap between wall & Door 4.00 Each 4,268.00 17,072.00
frame by using silicone sealant and Wool insulaion
on both side of the door
102 8 Supply & fixing of SS 304 grade D Type SS Pull 4.00 Set 2,276.00 9,104.00
Handle B2B of size 300mm mm Long of Geze-
98163016 / Becker FS-BPH1001-12/ Lockwood 144-
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
103 9 Supply & fixing of Mortise Dead Lock Geze / Becker 4.00 Each 4,979.00 19,916.00
FS-DL7260K / Lockwood V1-4 Make with minimum
100mm long Euro Profile Cylinder with Both Side
104 10 Providing and Fixing Channelled Woodworks 510.00 Sqm 7,144.84 36,43,868.40
perforated panels made of a Moisture resistant
fibre board substrate with a laminated facing as per
the approved shade. Item is to be executed as per
approved drawing , design and as per directions of
Engineer-in-charge
105 11 Providing and installation of Multipurpose Vinyl 120.00 Sqm 2,845.00 3,41,400.00
Sports Sheet Flooring (Armstrong Athleta or
equivalent) 4.5 mm thk, Inc, 1.8m wide and 15 m
long, having a nominal total thickness of 4.5mm.
The wear surface shall be 0.45 mm and PUR coated
with UV Treatment. Total weight should
3.03mm/sqm. Athleta shall conform to flammability
Class Cfl as per EN 13501-1;Shock Absorption more
than 28%; sliding coefficient of 0.45-0.65; energy
return of 0.38m/s; vertical deformation of 2.3 mm
and sound insulation of 20-22 db. Impact Resistance
of 8N/M (as per DIN18032); Abrasion Resistance of
7 mm, Indentation Resistance of0.6mm (as per
EN1016), Friction Coefficient of 0.6 (as per
GB/T14833-1993) and Rebound Coefficient of 0.86
(as per GB/T14833-1993). Design and shade to be
as per architect choice, Installation should be done
by authoiriesd certified distributor
Single component Self Levelling Underlay for -
12 Providing and applying 5mm Moisture insenstive -
Self leveling flooring for surface area as per the
specifications listed below and as approved by the
engineer-in-charge:
Providing & applying Fibtop 90 (Cementitious 1K -
self leveling screed) of Fibrex Make on the Surface
to be treated which should be free from all dust dirt
debris and unsound materials and oil. Use grinding
media to cover as much undulation as possible but
up to 1mm. Apply Fibloor cem Primer @ 150-
250gms/sq m (depending on surface ) over the
treated surface and allow to cure for at least 48-72
hrs before applying final coat over the treated
surface , Apply FIBTOP-90 Cementitious Single
component self levelling screed @ 8kg per square
meter for DFT of 5mm thickness through notch
trowel and after that use spike roller to remove/
release air trapped inside the product FIBTOP- 90.
This provide a compressive strength after 28 days
curing of approx. 35 N/mm2 ,Flexural Strength after
28n days will be 8.8 N/mm² to achieve total 5mm
thickness as per engineer-incharge of approved
make Fibrex or equivalent.
All the work has to be carried out by the approved -
specialist agency.
1) Fibfloor Cem Primer -48 hrs
2) Fibtop-90 -48 hrs Complete Curing for 72 hrs
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
13 Providing and laying Saint Gobain Ecophon - -
Advantage E tegular edge tile with 15 mm thickness
,easily demountable tile , manufactured from High
density glass wool , visible surface is a batch
painted glass tissue in white, back of the tile
covered with glass tissue. Size 600x600x15mm,
1200x600x15mm Acoustics-Sound absorption(Alpha
W) - 0.95 at 200 mm o.d.s as per EN ISO 354
Acoustics-Sound absorption Class - Class A at 200
mm o.d.s as per EN ISO 11654Acoustics-Articulation
class - 180 as per ASTM E1111, ASTM E1110
NRC - 0.9 NRC as per ASTM C 423
Humidity Resistance -Permanent ambient RH up to
95% at 30*C without sagging, warping and
delaminating ( 13964:2014).
Fire Safety - Tested and classified as non
combustible according to EN ISO 1182 with reaction
to fire classification class A2 s1 d0 according to EN
13501-1 - European Standard.
Light Reflectance - 83% light reflectance.
Indoor Health & Well-being - Complying with the
French regulation on VOC emissions, A+ level.
Certified by the Finnish Building Information Group
(RTS) with the M1 label. Free from substances of
very high Concern (SVHC) above 100 ppm as
defined by the European REACH regulation
(No1907/2006).Product Certified under GRIHA
council of India for Green Ratings. Environmental
Product declaration (EPD) acc to international ISO
14025 & EN 15804 series of standards.
107 13.1 Circularity - Re-cycled
Framing system:- content
Providing of fixing
and more than 70% pre
coated (Exposed portion only) GI T Grid system in
600x600mm module which includes providing and
fixing wall angle along the perimeter of the room
with help of nylon sleeves and wooden screws at
300mm centers. Then suspending the main tee of
size from the soffit with help of soffit cleat, rawl
plugs and wire rod with Leveling spring clip at
1200mm c/c. 1200mm Cross Tee is then interlocked
into the pre-cut slots in the main Tees at 600mm
centres in direction perpendicular to the main Tee
to make a grid of 600x1200mm.Finally 600mm
Cross tees are then interlocked into the pre cut slots
in the 1200mm tees at 1200mm centres and in
direction parallel to the main tee. Cross Tees having
length more than 600mm are to be supported
Dimensions:- Main Runner ‘T’ section of size
14x32mm hot dipped galvanized steel body and
capped with precoated of dipped galvanized steel
and 3.6mtr. Long. Cross Runner ‘T’ section of size
14x32mm hot dipped galvanized steel body and
capped with precoated of dipped galvanized steel
and 1.2/0.6mtr. Long. Perimeter wall angle of hot
dipped galvanized steel angle body of size 19x19mm
and 3.05mtr. long
Total of the Sub-Head - Non Schedule Items : 55,19,940.40
Digitally signed by PRIYA
Name of the work : Constrcution of Community Center for SAIL, Gua Ore Mines
BOQ for External Development Civil Works
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
Sub-Head : Earth Work
2.6 Earth work in excavation by mechanical means
(Hydraulic excavator) / manual means over areas
(exceeding 30cm in depth, 1.5m in width as well as 10
sqm on plan) including getting out and disposal of
excavated earth, lead up to 50m and lift up to 1.5m,as
directed by Engineer-in-Charge.
1 2.6.1 All kinds of soil 42.72 Cum 189.98 8116.00
2.7 Earth work in excavation by mechanical means
(Hydraulic excavator) / manual means over areas
(exceeding 30 cm in depth, 1.5m in width as well as 10
sqm on plan) including getting out and disposal of
excavated earth, lead up to 50 m and lift up to 1.5m, as
directed by Engineer-in-Charge.
2 2.7.1 Ordinary rock Cum 533.97
3 2.25 Filling available excavated earth (excluding rock) in 42.72 Cum 209.78 8962.00
trenches, plinth, sides of foundations etc. in layers not
exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift
4 2.25A Excavating, supplying and filling of local earth (including 2417.73 Cum 749.75 1812679.00
royalty) by mechanical transport up to a lead of 5 km,
also including ramming and watering of the earth in
layers not exceeding 20 cm in trenches, plinth, sides of
foundation etc., complete.
5 2.27 Supplying and filling in plinth with sand under floors, 32.10 Cum 2273.05 72965.00
including watering, ramming, consolidating and dressing
Total of the Sub-Head - Earth Work : 1902722.00
Sub-Head : Concrete Work
4.1 Providing and laying in position cement concrete of
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
6 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from 139.57 Cum 7290.88 1017564.00
natural sources : 8 graded stone aggregate 40 mm
nominal size derived from natural sources).
7 4.11 Providing and laying damp-proof course 50mm thick 100.00 Sqm 530.60 53060.00
with cement concrete 1:2:4 (1 cement : 2 coarse sand
(zone-III) derived from natural sources : 4 graded stone
aggregate 20mm nominal size derived from natural
8 4.12 Extra for providing and mixing water proofing material in 100.00 units 19.43 1943.00
cement concrete work in doses by weight of cement as
per manufacturer’s specification.
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
9 4.13 Providing and applying a coat of residual petroleum 100.00 Sqm 156.42 15642.00
bitumen of grade of VG-10 of approved quality using 1.7
kg per square metre on damp proof course after
cleaning the surface with brushes and finally with a piece
of cloth lightly soaked in kerosene oil.
Total of the Sub-Head - Concrete Work : 1088209.00
Sub-Head : Reinforced Cement Concrete
5.9 Centering and shuttering including strutting, propping
etc. and removal of form for :
10 5.9.1 Foundations, footings, bases of columns, etc. for mass 50.67 Sqm 419.72 21266.00
Walls (any thickness) including attached pilasters,
butteresses, plinth and string courses etc.
11 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts 50.00 Sqm 1028.88 51444.00
12 5.9.21 Lintels, beams, plinth beams, girders, bressumers and 31.05 Sqm 901.14 27980.00
cantilevers with water proof ply 12 mm thick
5.22 Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in position and
binding all complete upto plinth level.
13 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or 24299.00 Kg 115.43 2804879.00
5.22A Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in position and
binding all complete above plinth level.
14 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or 4800.00 Kg 115.43 554073.00
5.33 Providing and laying in position ready mixed or site
batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine
aggregate derived from natural sources, Portland
Pozzolana/ Ordinary Portland/ Portland Slag cement,
admixtures in recommended proportions as per IS: 9103
to accelerate/ retard setting of concrete, to improve
durability and workability without impairing strength;
including pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of centering,
shuttering, finishing and reinforcement as per direction
of the engineer-in-charge; for the following grades of
Note: Extra cement up to 10% of the minimum specified
cement content in design mix shall be payable
separately. In case the cement content in design mix is
more than 110% of the specified minimum cement
content, the contractor shall have discretion to either re-
design the mix or bear the cost of extra cement
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
5.33.1 All works upto plinth level
15 5.33.1.1 Concrete of M25 grade with minimum cement content 148.80 Cum 10172.93 1513733.00
5.33.2 All works above plinth level upto floor V level
16 5.33.2.1 Concrete of M25 grade with minimum cement content 10.00 Cum 10553.59 105536.00
17 5.35 Add for using extra cement in the items of design mix 44.64 Qtl 785.07 35045.00
over and above the specified cement content therein.
Total of the Sub-Head - Reinforced Cement Concrete : 5736148.00
Sub-Head : Masonry Work
6.1 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in foundation and plinth
18 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 50.00 Cum 7633.65 381682.00
6.4 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in superstructure above
plinth level up to floor V level in all shapes and sizes in :
19 6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 6.00 Cum 9746.10 58477.00
Total of the Sub-Head - Masonry Work : 440159.00
Sub-Head : Steel Work
10.25 Steel work welded in built up sections/ framed work,
including cutting, hoisting, fixing in position and applying
a priming coat of approved steel primer using structural
steel etc. as required.
20 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, 1793.58 Kg 184.73 331334.00
gates and similar works.
10.16.3 CS- Steel work in built up tubular (round, square or 2400.00 Kg 208.07 499359.00
18 rectangular hollow tubes etc.) trusses etc., including
cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer, including welding and
bolted with special shaped washers etc. complete.
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
21 12.50 Providing and fixing precoated galvanised iron profile 160.00 Sqm 790.58 126492.00
sheets (size, shape and pitch of corrugation as approved
by Engineer-in-Charge) of total coated thickness 0.50mm
(base metal of minimum 0.45mm thickness with total
coating thickness of 0.05mm) with zinc coating 120
grams per sqm as per IS:277, in 240 mpa steel grade, 5-7
microns epoxy primer on both side of the sheet and
polyester top coat 15-18 microns. Sheet should have
protective guard film of 25 microns minimum to avoid
scratches during transportation and should be supplied
in single length upto 12 metre or as desired by Engineer-
in- charge. The sheet shall be fixed using self drilling /self
tapping screws of size (5.5x 55 mm) with EPDM seal,
complete upto any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters and
trusses and including cutting to size and shape wherever
Total of the Sub-Head - Steel Work : 957185.00
Sub-Head : Finishing
22 13.2 15 mm cement plaster on the rough side of single or half
brick wall of mix :
13.45 Finishing walls with textured exterior paint of required
24 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 300.00 Sqm 239.32 71796.00
sqm) over and including priming coat of exterior primer
applied @2.20kg/10 sqm.
13.61 Painting with synthetic enamel paint of approved brand
and manufacture to give an even shade :
25 13.61.1 Two or more coats on new work. 300.00 Sqm 166.86 50058.00
Total of the Sub-Head - Finishing : 244831.00
Sub-Head : Road Work
26 16.1 Preparation and consolidation of sub grade with power 300.00 Sqm 234.29 70287.00
road roller of 8 to 12 tonne capacity after excavating
earth to an average of 22.5 cm depth, dressing to
camber and consolidating with road roller including
making good the undulations etc. and re- olling the sub
grade and disposal of surplus earth with lead upto 50
16.47 Painting runway/ taxi track/ apron marking with
adequate nos of coats to give uniform finish with road
marking paint of superior make as approved by the
Engineer-in-charge, i/c cleaning the surface of ail dirt,
scales, oil, grease and other foreign material etc. and
lining out complete.
27 16.47.1 New work (Two or more coats) 180.00 Sqm 201.43 36257.00
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
28 16.68 Providing and laying 60mm thick factory made cement 214.00 Sqm 1040.33 222631.00
concrete interlocking paver block of M -30 grade made
by block making machine with strong vibratory
compaction, of approved size, design & shape, laid in
required colour and pattern over and including 50mm
thick compacted bed of coarse sand, filling the joints
with fine sand etc. all complete as per the direction of
Engineer-in-charge.
29 16.69 Providing and laying at or near ground level factory 12.00 Cum 10828.87 129946.00
made kerb stone of M-25 grade cement concrete in
position to the required line, level and curvature, jointed
with cement mortar 1:3 (1 cement: 3 coarse sand),
including making joints with or without grooves
(thickness of joints except at sharp curve shall not to
more than 5mm), including making drainage opening
wherever required complete etc. as per direction of
Engineer-in-charge (length of finished kerb edging shall
be measured for payment). (Precast C.C. kerb stone shall
be approved by Engineer-in-charge).
30 16.75 Providing and laying C.C. pavement of mix M-25 with 90.00 Cum 10514.41 946297.00
ready mixed concrete from batching plant. The ready
mixed concrete shall be laid and finished with screed
board vibrator , vacuum dewatering process and finally
finished by floating, brooming with wire brush etc.
complete as per specifications and directions of Engineer-
in charge. (The panel shuttering work shall be paid for
separately). (Note:- Cement content considered in this
item is @ 330 kg/cum. Excess/less cement used as per
design mix is payable/ recoverable separately).
Total of the Sub-Head - Road Work : 1405418.00
Sub-Head : Precast Boundary wall
Digitally signed by PRIYA
Sl.No. Description of Item Quantity Unit Rate (Rs) Amount(Rs)
Fabrication and manufacturing of solid precast concrete
element with provisions of shear keys, connecting loops,
dowel tubes and proper lifting accessories for walls,
beams, slabs, stairs, column etc, of various thickness,
shape and size of different concrete grades
manufactured in controlled factory environment with
approved methodology including moulds (Pallet system,
Tilts form, table moulds, battery moulds, vertical
moulds, beam moulds, column moulds, staircase
26.74 moulds, Facade mould, etc.), mixing, transporting and
placing of concrete, vibrating, curing, finishing, making
necessary cutout/holes of required sizes for services,
yard handling & stacking all complete as per IS
11447:1985 and as per approved shop drawings and
design mix as per the direction of Engineer-in-Charge
(Cost of reinforcement, Mechanical, Electrical and
Plumbing inserts will be paid separately).
31 26.74.1 Concrete grade M-35 (Cement content 370 kgs) 20.58 cum 22399.99 460925.00
Steel reinforcement for R.C.C. work including
5.22A straightening, cutting, bending, placing in position and
binding all complete above plinth level.
32 5.22A.2 Hard drawn steel wire 308.66 Kg 102.53 31648.00
Transportation of Precast Elements by flat bed Trailor
(Double / Triple axle 40ft Length with proper accessories
26.76 like A frame etc) from factory, including the cost of
loading, unloading & stacking at site with the help of
required capacity cranes.
26.77 Erection & Installation of Precast/Prestressed Concrete
elements in correct & final position with proper line level
and plumb at site making all arrangements (i.e cranes,
push-pull jacks & all another T & P for lifting Placing &
Alignment of elements, within erection tolerance as per
IS 15916 as per approved shop drawings and all
complete as per the direction of Engineer-in-Charge but
excluding the cost of sim pads, non shrink grout and
steel works i.e hangers. All work up to fifth floor.
33 26.77.3 Solid concrete wall elements 20.58 cum 2911.54 59911.00
Total of the Sub-Head - Precast Boundary wall : 638246.00
Digitally signed by PRIYA
Name of Project: COMMUNITY CENTER , BOKARO
PLUMBING WORKS DETAILED ESTIMATE
S.I DSR MR MR DSR
Description of Item Unit Total Qty
No Item No Item No Rate Amount Rate Amount
SUBHEAD-I(Sanitary Fixtures & CP Brass Fittings)
1 17.3 MR 1 Providing and fixing white vitreous china pedestal type water
closet (European type) with seat and lid, 10 litre low level
white vitreous china flushing cistern & C.P. flush bend with
fittings & C.I. brackets, 40 mm flush bend, overflow
arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete,
including painting of fittings and brackets, cutting and making
good the walls and floors wherever required :
1.1 17.3.2 MR 1.1 W.C. pan with ISI marked black solid plastic seat and lid Each 8 8,427.86 67422.90632
2 17.7 MR 2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. -
brass pillar taps, 32 mm C.P. brass waste of standard pattern,
including painting of fittings and brackets, cutting and making
good the walls wherever require:
2.1 17.7.2 MR 2.1 White Vitreous China Wash basin size 630x450 mm with a Each 7 2,382.86 16680.03684
single 15 mm C.P. brass pillar tap
3 17.22A MR 3 Providing and fixing CP Brass 32 mm size Bottle Trap of Each 7 1,107.55 7752.82508
approved quality & make and as per the direction of Engineer-
4 17.4 MR 4 Providing and fixing white vitreous china flat back or wall -
corner type lipped front urinal basin of 430x260x350 mm and
340x410x265 mm sizes respectively with automatic flushing
cistern with standard flush pipe and C.P. brass spreaders with
brass unions and G.I clamps complete, including painting of
fittings and brackets, cutting and making good the walls and
floors wherever required :
4.4 17.4.1 MR 4.1 One urinal basin with 5 litre white P.V.C. automatic flushing Each 8 6,698.74 53589.921
5 17.16A MR 5 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube Each 8 373.70 2989.56196
upto 1 metre long with S.S. triangular plate to Eureopean type
W.C. of quality and make as approved by Engineer - in -
6 18.53 MR 6 Providing and fixing C.P. brass angle valve for basin mixer and Each 25 614.67 15366.83225
geyser points of approved quality conforming to IS:8931
7 MR 7 Providing & Fixing in position C.P. Brass coat hook of -
approved make (to the approval of Engineer-in-charge ) fixed
into wall with C.P. brass screws and rawl plugs etc. complete
in all respect.
7.1 MR 7.1 C.P.Brass coat hook Each 8 962 7696 -
8 17.31 MR 8 Providing and fixing 600x900 mm beveled edge mirror of Each 7 1,720.99 12046.9222
superior glass (of approved quality) complete with 6 mm thick
hard board ground fixed to wooden cleats with C.P. brass
screws and washers complete.
9 17.72 MR 9 Providing and fixing PTMT towel ring trapezoidal shape 215 Each 7 248.26 1737.792595
mm long, 200 mm wide with minimum distances of 37 mm
from wall face with concealed fittings arrangement of
approved quality and colour, weighing not less than 88 gms.
10 17.71 MR 10 Providing and fixing PTMT liquid soap container 109 mm Each 7 180.19 1,261.30
wide, 125 mm high and 112 mm distance from wall of
standard shape with bracket of the same materials with snap
fittings of approved quality and colour, weighing not less than
11 17.10 MR 11 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen - -
sink as per IS:13983 with C.I. brackets and stainless steel plug
40 mm, including painting of fittings and brackets, cutting and
making good the walls wherever required:
11.1 17.10.1 MR 11.1 Kitchen sink with drain board - -
12 MR 12 Fixing of 15 mm C.P brass wall mounted mixing fittings Each - -
swinging spout for sink complete including cutting and
making good the walls where required. (Pantry, Kitchen,
Coffee-Break etc.)
Digitally signed by PRIYA
13 17.28 MR 13 Providing and fixing P.V.C. waste pipe for sink or wash basin - -
13.1 17.28.2 MR 13.1 Flexible pipe - -
SUBHEAD II(Soil, Waste, Vent & Rain Water Pipes) -
14 MR 1 Supply, installation , testing commissioning of PP Mineral
filled low noise Soil & Waste system as per EN 12056,
with density 1.9 g/cm3. PP mineral(Astolan) filled Low noise
system should has a fire classification DIN 4102-
B2/EN13501 . Product should have a chemical resistance of
pH 2-12 and is a complete sound protection system
according to DIN 4109. including with push fit rubber ring
sockets all necessary fittings and specials such as Bends,
junctions, offsets & vent cowl. Fixing at wall/ceiling level
supported by rubber line bracket & hangers etc. duly epoxy
coated. Cutting, chases/holes in floors / walls /
slab.Compliant with LABC. Weight mass per unit area of
DN100MM should not be less than 110.07kg/m3. sound
levels of not more than 15dBA as per EN 14366 at a flow
rate of 4 l/s.including all core cut ,chases ,cutting making
holes in all wall and floor as required complete in all respect.
15 MR 2 Providing fixing, testing and commissioning in position Solfit
SWR uPVC PIPE TYPE-B pipe comforming to IS:13592
including all fittings such as bends, junctions, inspection doors,
offests, cowl, access pieces/clean out plugs, clamps /supports/
hangers etc. jointing with PVC Adhesive joints including
cutting holes in walls, core cutting in slabs and making good
the same. All complete as per specification and direction of
E/l.(For rainwater piping) -
16 MR 3 Providing Fixing straight /offset type single body push fit type WC -
pan connector with factory supplied spring loaded seal
guard with integral single mould sealing fins made of flexible
EVA body, including bush/adaptor as supplied with the pan
connector (if required). Each 8 800 6400
Providing and fixing floor drain (FD) with 50mm/40mm outlet
and one 40mm inlet for waste, with SS grating (adjustable
height), having 50mm water seal and in-built NRV
18 MR 5 Providing and fixing PP/UPVC trap of self cleansing design with
screwed down or hinged grating with or without vent arm
complete, including cost of cutting and making good the walls and
18.1 MR 5.1 100 mm inlet and 100 mm outlet -
18.1.1 MR 5.1.1 Sand cast iron S&S as per IS: 3989 Each 15 3,986 59794.42483 -
19 MR 6 Providing and fixing PP/UPVC grating with Cockroach proof -
strainer of approved design including setting in floor with
cement motor to match with floor finish as per architect
requirement suitable for waster and FT.
20 MR 7 Providing and fixing PP/UPVC brass grating with frame of -
approved design including setting in floor with cement motor
to match with floor finish as per architect requirement.
21 MR 8 Providing and fixing PP/UPVC extention piece for 100 mm dia
floor trap formed out of main pipe with multiple side inlets,
suitable for various dia pipes including all fixtures as required
complete as per drawing approved sample and direction of
engineer in charge. Each 15 2,508 37626.73563 -
22 MR 9 Providing and fixing cast PP floor clean out plug with
suitable insert keys for opening, male threaded joint with
threaded socket drip seal to soil / waste pipe as required
complete as per drawing approved sample and direction of
engineer in charge. Each 6 1,770 10617.15641 -
SUBHEAD III(Water Supply System(Internal)) -
Digitally signed by PRIYA
23 18.8 MR 1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings and fixing the
pipe with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same including
testing of joints complete as per direction of Engineer in
Concealed work, including cutting chases and making good
the walls etc(inside building) -
23.1 18.8.1 MR 1.1 15 mm nominal dia Pipes Mtr 50 532.80 26639.767
23.4 18.8.4 MR 1.4 32 mm nominal dia Pipes Mtr 5 791.27 3956.36395
23.5 MR 1.5 50 mm nominal dia Pipes Mtr 5 1,074 5371.25 -
24 18.7 MR 2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply and
all CPVC plain & brass threaded fittings, including fixing the
pipe with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and
testing of joints complete as per direction of Engineer in
Internal work - Exposed on wall(vertical & terrace area) -
24.5 MR 2.5 65 mm nominal dia Pipes Mtr RO 1,925 -
24.6 MR 2.6 80 mm nominal dia Pipes Mtr RO 2,491 -
25 18.18 MR 3 Providing and fixing ball valve (brass) of approved quality, -
High or low pressure, with plastic floats complete :
25.1 18.18.1 MR 3.1 15 mm nominal dia Pipes Each 1 435.45 435.45
25.2 18.18.2 MR 3.2 20 mm nominal dia Pipes Each 4 495.01 1980.06
25.3 18.18.3 MR 3.3 25 mm nominal dia Pipes Each RO 496.67
26 18.17 MR 4 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) : -
27 MR 5 Providing and fixing Butter fly valve with nitrile seat and
stainless steel stem with lever operation and cast iron body
in powder coated finish, suitable for test pressure of
10Kg/sq.mm) with flanges, gaskets and necessary pad
locking arrangement complete required. -
28 MR 6 Providing and fixing thermal insulation in cold/hot water
pipes a Polyolefin foam of closed cell structure having
thermal conductivity of 0.036 W/M.K at an average
temperature of 30oC. complete with 24 gauge aluminium
sheet/cladding. -
28.1 MR 6.1 15 mm dia pipe RM 5 45 -
28.6 MR 6.5 50 mm dia pipe RM RO 90 -
28.7 MR 6.6 65 mm dia pipe RM RO 105 -
28.8 MR 6.7 80 mm dia pipe RM RO 120 -
SUBHEAD IV(External Sewerage & Storm Water Drainage) -
29 MR 1 Excavation in trenches with straight or open cutting in streets,
lanes or in open area with 3D/JCB or excavator including
manually dressing bed, trimming sides and side slopes for
sewers and manholes to full depths as shown in
drawings,including, dressing to correct sections and
dewatering, provision for diversion for traffic, protection of
existing services i.e. telephone cables, electric lines, water
supply lines and gas lines etc. night signals, profiles, pegs,
sight rails, boning rods, watching, etc., fixing and maintenance
of caution boards, fencing, refilling trenches, watering,
ramming and restoration of surface to original level and
removal of surplus spoil from the site of works, upto one chain
(15m) complete in all respects
29.1 MR 1.1 Depth not exceeding 3 m. BGL -
Digitally signed by PRIYA
All kinds of soil except rocky Mtr 100 224 22400 -
30 MR 2 Excavation of trenches in a Streets, Lanes or in Open Area for
Storm Sewers and Manholes to Full Depths as Shown in
Drawings,excluding Shoring, Timbering of Poling Board Frame
System Type, dressing to correct sections and dewatering,
provision for diversion for traffic, protection of existing
services i.e. telephone cables ,electric lines, water supply lines
and gas lines.night signals, profiles, Pegs, Sight rails, boning
rods, crossing over trenches for access to the houses,
watching, fencing etc., fixing and maintenance of caution
boards, refilling trenches, watering of refill in 15 cm layers,
ramming and restoration of surface to original conditions and
removal of Surplus Spoil from the Site of Works, for all Works
other than connections to Ventilating Shafts upto a Lead of 15
30.1 MR 2.1 For depth not exceeding 2 m. below Ground level -
All classes of soil except rocky Mtr 100 224 22400 -
31 19.6 MR 3 Providing and laying non-pressure NP2 class (light duty) R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete : -
Providing, laying and jointing glazed stoneware pipes class SP-1
with stiff mixture of cement mortar in the proportion of 1:1 (1
cement : 1 fine sand) including testing of joints etc. complete : -
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse
sand : 10 graded stone aggregate 40 mm nominal size) all-round
S.W. pipes including bed concrete as per standard design : -
34 19.3 MR 5 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse
sand : 10 graded stone aggregate 40 mm nominal size) Upto
haunches of R.C.C. pipes including bed concrete as per
standard design : -
35 19.7 MR 5 Constructing brick masonry manhole in cement mortar 1:4 ( 1
cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1
cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20
mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4
coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal
size), inside plastering 12 mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished with floating coat of neat cement
and making channels in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size)
finished with a floating coat of neat cement complete as per
standard design :
35.1 19.7.1 MR 5.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with
frame (light duty) 455x610 mm internal dimensions, total weight of
cover and frame to be not less than 38 kg (weight of cover 23 kg
and weight of frame 15 kg) : -
19.7.1.2 MR 5.1.2 With Sewer bricks conforming to IS : 4885 Each 9 13,605.44 122448.9559
36 19.4 MR 6 Providing and fixing square-mouth S.W. gully trap class SP-1
complete with C.I. grating brick masonry chamber with water tight
C.I. cover with frame of 300 x 300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design: -
36.2 19.4.1.1 MR 6.1.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 Each 4 2,898.00 11591.99118
37 19.28 MR 7 Constructing brick masonry road gully chamber 45x45x77.5 cm
with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with
precast R.C.C. vertical grating complete as per standard design :
37.1 19.28.1 MR 7.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 Each 6 7,373.30 44239.7802
Providing orange colour safety foot rest of minimum 6 mm thick
plastic encapsulated as per IS : 10910, on 12 mm dia steel bar
conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as
165 mm with minimum 112 mm space between protruded legs
having 2 mm tread on top surface by ribbing or chequering
besides necessary and adequate anchoring projections on tail
length on 138 mm as per standard drawing and suitable to with
stand the bend test and chemical resistance test as per
specifications and having manufacture’s permanent identification
mark to be visible even after fixing, including fixing in manholes
with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal size)
complete as per design. Each 27 592.63 16000.87797
Digitally signed by PRIYA
Making connection of drain or sewer line with existing
manhole including breaking into and making good the walls,
floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand :
4 graded stone aggregate 20 mm nominal size) cement plastered
on both sides with cement mortar 1:3 (1 cement : 3 coarse sand),
finished with a floating coat of neat cement and making necessary
channels for the drain etc. complete :
39.1 19.21.1 MR 9.1 For pipes 100 to 250 mm diameter Each 2 867.42 1734.84927
40 MR 10 Constructing Brick masonry percolation pit 3m dia and 5m
deep with bricks of class designation 7.5 in cement mortar 1:6,
base concrete 1:4:8 below the brick wall, including cost of
necessary excavation in any type of soil, back filling as required
in 20cm thick layers, dewatering if any, shuttering and shoring
and disposal of surplus excavated material within 2 nos.
300mm dia borings to a depth of 9 metre (to be measured from
the bottom of the percolation pit), provisioning and fixing
160mm O.D. PVC pipes, tested to 6kg/sqcm, in each bore and
upto the height of 300mm above the RCC top slab. The PVC
pipe shall be slotted except 3.0 metres at the top and 3.0
metres below from the bottom of the percolation pit, which
shall be blind. Top of the PVC pipe shall be covered with PVC
Socket & plug. Each bore around the PVC pipe shall be filled
with pea gravels. The percolation pit shall be filled with river
stone/pebbles as shown in drawing. The top slab shall be
150mm thick with RCC M20 including nominal reinforcement
and 2 nos. of 560mm internal dia SFRC manhole covers
with frames conforming to IS:12592 -
(total weight of cover & frame shall not be less than 182 kg)
shall be provided in the top slab. PVC encased 12mm dia
steel bar Footrests shall be provided 300 centre to centre.
The above shall be provided all as specified and 300mm
dia RCC pipe for inlet and overflow as shown on drawings shall
be measured separately. Each 1 2,50,000 250000 -
41 MR 11 Material & labour for constructing Silt trap of size 1500mm x
3000mm x 2000mm deep in R.C.C. walls including necessary
excavation and foundation concrete 150mm thick in 1:4:8 (1
cement : 4 coarse sand : 8 graded stone aggregate of 40mm
nominal size), inside plaster 12mm thick in cement mortar 1:4
(1 cement : 4 coarse sand) finished with a floating coat of neat
cement, C.C. floor, RCC slab in mix 1:2:4 & RCC baffle wall
including reinforcement, centering & shuttering including
12mm dia steel bar footrests etc. and SFRC manhole cover and
frame of 610mm x 455mm internal dimension conforming to
IS: 12592 (total weight of cover & frame shall not be less
SUBHEAD V(External Water Supply) -
42 18.12 MR 1 Providing and fixing G.I. pipes complete with G.I. fittings including
trenching and refilling etc. -
External work -
43 18.40 MR 2 Painting G.I. pipes and fittings with two coats of anti-corrosive
bitumastic paint of approved quality : -
44 18.14 MR 3 Fixing water meter and stop cock in G.I. pipe line including
cutting and threading the pipe and making long screws etc.
complete (cost of water meter and stop cock to be paid
separately). Each 1 869.40 869.40469
45 18.37 MR 4 Constructing masonry Chamber 60x45x50 cm inside, in brick
work in cement mortar 1:4 (1 cement : 4 coarse sand) for water
meter complete with C.I. double flap surface box 400x200x200
mm (inside) with locking arrangement and RCC top slab 1:1.5:3
mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20
mm nominal size), including necessary excavation, foundation
concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone
aggregate 40 mm nominal size) and inside plastering with cement
mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a
floating coat of neat cement complete as per standard design :
Digitally signed by PRIYA
Name of Project : Community Center,Bokaro
Name of Work : FIRE FIGHTING WORK
S.I MR DSR 2022 DSR 2022 MR
Description of Item Unit Total Qty
No Item No Item No Rate Amount Rate Amount
SUBHEAD I:FIRE HYDRANT SYSTEM
Supplying, installation, testing and commissioning of electric
driven terrace pump suitable for automatic operation and
consisting of following, complete in all respects, as required:
Horizontal type, multistage, centrifugal, split casing pump of
cast iron body & bronze impeller with stainless steel shaft,
mechanical confirming to IS : 1520
Suitable HP squirell cage induction motor TEFC type suitable
for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55
class of protection for enclosure, horiziontal foot mounted
type with Class-'F' insulation, conforming to IS-325
M.S.fabricated common base plate, coupling, coupling guard,
foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with
anti vibration pads
Providing, laying, testing & commissioning of 'C' class heavy
duty MS pipe conforming to IS 3589/IS 1239 including
Welding, fittings like elbows, tees, flanges, tapers, nuts bolts,
2 MR 2 18.7 gaskets etc. and fixing the pipe on the wall/ceiling with
suitable clamp/support frame and painting with two or more
coats of synthetic enamel paint
of required shade complete as required : -
Supplying and fixing single headed internal hydrant valve with
instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia
3 MR 3 18.9 with cast iron wheel ISI marked conforming to IS 5290 (Type -
A) with blank Gunmetal/Stainless teel cap and chain as
3.1 MR 3.1 18.9.1 Single Headed Gunmetal Each 2 8,183.51 16367.0276
Supplying, fixing, testing and commissioning of butterfly valve
of PN 1.6 rating with bronze/gunmetal seat duly ISI conforming
to IS 13095 of following sizes as required :
Providing, installation, testing and commissioning of non-
return valve of following sizes confirming to IS: 5312 complete
with rubber gasket, GI bolts, nuts,washers etc.as required :.
Providing, installation, testing and commissioning of stainless
steel Y-strainer fabricated out of 1.6 mm thick stainless steel,
Grade 304, sheet with 3 mm dia
holes with stainless steel flange. -
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with
63 mm dia male and female couplings duly bound with GI wire,
rivets etc. conforming to IS 636 (type-A) as required:
Digitally signed by PRIYA
Supplying and Fixing First Aid Hose Reel, wall mounting
swinging type complete with drum & bracket of MS
8 MR 8 18.17 construction, spray painted in Post office Red, confirming to IS
884/1995 with upto date amendments, complete with the
following as required. -
20 mm nominal internal dia as per IS 12585 water hose
thermoplastic (Textile reinforced)Type II as per IS: 12585 -
20 mm dia. ball valve & nozzle. -
Drum and brackets for fixing the equipments on wall. -
Connection from riser with 25 mm dia gun metal stop valve
and M.S pipe as reqd. -
Supplying & fixing 63 mm dia gun metal short branch pipe with
20 mm nominal internal diameter size nozzle conforming to IS
903 suitable for instantaneous connection to interconnect
hose pipe coupling as required: -
Supplying and fixing orifice plate made out of 6 mm thick
stainless steel(Grade 304) with orifice of required size to be
10 MR 10 18.13 fitted between flange &landing valve of external and internal
hydrants to reduce presure at the outlet to the level of 3.5
kg/sq.cm complete as required. Each 2 1,413.87 2827.7326
Supplying and fixing air vessel made of 250 mm dia, 8 mm
thick MS sheet, 1200 mm in height with air release valve on
top and flanged connection to riser, drain arrangement with
25 mo dia gun metal wheel valve with required accessories,
pressure gauge and painting with synthetic enamel paint of
approved shade as required. Each 1 19,526.55 19526.5532
Providing and fixing standard fire man's axe with heavy duty
insulated rubber handle. Each 2 - 846.00 1692
Providing and fixing fire hose cabinet fabricated from 16 gauge
M.S. Sheet with single or double glazed front door (with 4 mm
13 MR 13 thick glass) and locking arrangement, painted fire red with
stove enamelled paint "FIRE HOSE" written on front including
necessary supports approximate size. -
Providing and fixing dial type pressure gauge with isolation
cock and pipe at hydrant station. -
14.1 MR 14.1 Diameter 100 mm calibration 0-8 Kg. Each 2 - 760.00 1520
Providing and fixing CO2 type fire extinguishers with steel
cylinder with a discharge valve and conforming to IS:15683.
15 MR 15 Extinguishers shall be painted with rex enamel paint and fixed
to wall with brackets capacity 4.5 Kg.
Providing and fixing ABC powder type fire extinguisher
suitable for inverted operation and fabricated from 1.6 mm
M.S. sheet internally protected with anticorrosive treatment
and hydraulically tested to a pressure of 25 Kg/Sqcm.
16 MR 16 Extinguishers externally painted with red enamel and fixed to
wall with brackets complete with internal charge and spanner
(Conforming to IS:15683 capaicity 6 KG.).
Digitally signed by PRIYA
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
(SCHEDULE OF QUANTITIES)
NAME OF WORK: Estimate For Providing Electrical Works For Bokaro Community Centre Building
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
A SCHEDULE ITEMS
WIRING AND SUB MAINS
Wiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed
1 1.3.3 heavy class Steel conduit, with modular switch, Point 132 1,974.70 260660.86
modular plate, suitable GI box and earthing the point
with 1.5 sq.mm. FRLS PVC insulated copper
conductor single core cable etc as required.a) Group C
Wiring for twin control light point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in
surface / recessed Steel conduit, 2 way modular
switch, modular plate, suitable GI box and earthing the
point with 1.5 sq.mm. FRLS PVC insulated copper
conductor single core cable etc as required
Wiring for light/ power plug with 2X4 sq. mm FRLS
PVC insulated copper conductor single core cable in
3 1.5 surface/ recessed Steel conduit alongwith 1 No 4 sq. Point 725 463.44 335993.93
mm FRLS PVC insulated copper conductor single core
cable for loop earthing as required
Wiring for light/ power plug with 4X4 sq. mm FRLS
PVC insulated copper conductor single core cable in
4 1.6 surface/ recessed Steel conduit alongwith 2 Nos 4 sq. metre 10 708.54 7085.39
mm FRLS PVC insulated copper conductor single core
cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire
with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed Steel
conduit as required.
a 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire metre 600 394.94 236964.42
b 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire metre 5 458.09 2290.44
b 1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire metre 5 630.41 3152.03
d 1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire metre 5 759.91 3799.57
e 1.7.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire metre 90 988.96 89006.15
f 1.7.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire metre 35 1,247.97 43678.94
g 1.7.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire metre 5 1,760.64 8803.22
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess,
including providing and fixing 3 pin 5/6 amps modular
socket outlet and 5/6 amps modular switch,
connection etc. as required. (For light plugs to be used
in non residential buildings).
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess,
7 1.32 including providing and fixing 6 pin 15/16 amps Each 25 627.20 15679.90
modular socket outlet and 15/16 amps modular switch,
connection etc. as required.
Supplying and fixing of following modular switch/
socket outlet on the existing Modular plate & switch
including connection but excluding modular plate etc.
b 1.24.4 3 pin 5/6 amp socket outlet Each 14 130.58 1828.07
d 1.24.5 6 pin 15/16 amp socket outlet Each 1 210.85 210.85
e 25 amp switch Each 4 214.06 856.24
Supplying and fixing following size/ modules, GI box
Boxes alongwith modular base & cover plate for
modular switches in recess etc as required.
a 1.27.1 1 or 2 Module (75mmX75mm) Each 2 318.95 637.90
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
10 2.18 Supplying and fixing 20 amps, 240 volts, SPN
industrial type, socket outlet, with 2 pole and earth,
metal enclosed plug top along with 20 amps "C"
curve, SP, MCB, in sheet steel enclosure, on Each 2 1,734.96 3469.91
surface or in recess, with chained metal cover for the
socket out let and complete with connections, testing
and commissioning etc. as required.
11 1.25 Supplying and fixing stepped fan regulator on the
existing modular plate switch box including
connections but excluding modular plate etc. as
12 Supplying and fixing of 16 SWG M.S. Fan Box 12.5"
Rod but without fan cover (hylam sheet). as required. Nos. 3 214.06 642.18
13 Supplying and fixing of fan cover (hylam sheet).on the
existing Fan Box as required.
14 Supplying and fixing of modular Blanking plate on the
1.26 existing modular plate & switch box excluding modular Each 35 42.81 1498.42
plate etc. as reqd.
TELEPHONE / TV -
15 1.24 Supply and fixing following modular switch/socket on
the existing modular plate and cover plate & switch
box including connections but excluding modular plate
etc. as required.
a 1.24.6 Telephone socket outlet. (RJ - 11) Each 6 158.40 950.43
b 1.24.7 TV antenna socket outlet Each 1 158.40 158.40
16 1.27 Supplying and fixing following size/modules, GI box
along with modular base and cover plate for modular -
switches in recess etc as required.
18 1.18 Supplying and drawing following pair, 0.5 sq.mm FR
PVC insulated copper conductor, unarmoured
telephone cable in the existing surface / recessed steel
/ PVC conduit as required.
19 1.27.1 Supply, laying, testing and commissioning of the
following co-axial PVC insulated conductor cable in
existing surface / recessed conduit etc. and including -
making terminal joints, complete as required.
20 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN
Cable in the existing surface/ recessed Steel/ PVC -
conduit/ raceway as required.
a 1.53.1 1 run of cable Metre 150 61.01 9151.07
b 1.53.2 2 run of cable Metre 60 102.75 6164.93
c 3 run of cable Metre 85 143.42 12190.72
Supplying and fixing of following sizes of steel conduit
along with accessories in surface/recess including
21 1.2 painting in case of surface conduit, or cutting the wall -
and making good the same in case of recessed
conduit as required.
Supplying and fixing of following sizes of heavy class
PVC conduit along with accessories in surface/recess
including cutting the wall and making good the same in
case of recessed conduit as required.
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
DISTRIBUTION BOARDS -
Supplying and fixing following way, Horizontal type
three pole and neutral, sheet steel, MCB distribution
board, 415 volts, on surface/recess, complete with
tinned copper bus bar, neutral bus bar,
interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
a 2.4.1 4 way (4 + 12), Double door, Horizontal Each 1 4,378.60 4378.60
b 2.4.2 6 way (4 + 18), Double door, Horizontal Each 2 5,323.67 10647.34
c 2.4.3 8 way (4 + 24), Double door, Horizontal Each 1 6,386.48 6386.48
Supplying and fixing following way, Horizontal type
three pole and neutral, sheet steel, MCB distribution
board, 240 volts, on surface/recess, complete with
tinned copper bus bar, neutral bus bar,
interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
a 2.3.3 12 way, Double door Set 1 2,477.74 2477.74
b 2.3.4 16 way, Double door Each 1 3,361.81 3361.81
Supplying and fixing following rating, four pole, 415
volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as
Supplying and fixing following rating, double pole, 240
V,isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as
Supplying and fixing following rating, double pole,
(single phase and neutral), 240 volts, residual current
circuit breaker (RCCB), having a sensitivity current
upto 30 milliamperes in the existing MCB DB complete
with connections, testing and commissioning etc. as
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10
kA, "C" curve, miniature circuit breaker suitable for
28 2.10 inductive load of following poles in the existing MCB -
DB complete with connections, testing and
commissioning etc. as required.
a 2.10.1 Single pole Each 102 274.00 27947.67
Supplying and fixing single pole blanking plate in the
existing MCB DB complete etc. as required.
ERRECTION OF FAN & FIXTURE -
Installation ,Testing, Commissioning of wall bracket
fittings of all sizes and shapes including LED lamps
per fitting, complete with all accessories including
connections etc. as required.
Installation, testing and commissioning of pre-wired,
fluorescent fitting / compact fluorescent fitting /
LED Fittings of all types, with all accessories
31 1.41 and tube etc. directly on ceiling/ wall, including each 50 220.48 11024.09
connection with 1.5 sq. mm FR PVC insulated, copper
conductor, single core cable and earthing etc. as
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Installation, testing and commissioning of pre-wired,
fluorescent fitting / compact fluorescent fitting /
LED Fittings of all types and shape, with all
32 accessories and tube etc. on falsceiling including each 65 267.58 17392.38
connection with 1.5 sq. mm FR PVC insulated, copper
conductor, single core cable and earthing etc. as
Supply, Installation, Testing and Commissioning of
1200 mm sweep, BEE 5 star rated, ceiling fan with
Brush Less Direct Current (BLDC) Motor, class of
insulation: B, 3 nos. blades, 30 cm long down rod, 2
nos. canopies, shackle kit, safety rope, copper
winding, Power Factor
not less than 0.9, Service Value (CM/M/W) minimum
6.00, Air delivery minimum 210 Cum/Min , 350 RPM
(tolerance as per IS : 374-2019), THD less than 10%,
remote or electronic regulator unit for speed control
and all remaining accessories including safety pin, nut
washers, temperature rise=75 degree C (max.),
insulation resistance more than 2 mega ohm, suitable
for 230 V, 50 Hz, single phase AC Supply, earthing
etc. complete as required.
Installation of exhaust fan in the existing opening,
34 1.5 including making good the damage, connection, -
testing, commissioning etc. as required.
a 1.50.1 Upto 450 mm sweep each 2 481.64 963.27
Extra for fixing the louvers/ shutters complete with
frame for a exhaust fan of all sizes.
EARTHING & LIGHTNING ARRESTER -
Earthing with G.I. earth pipe 4.5 metre long, 40 mm
dia including accessories, and providing masonry
enclosure with cover plate having locking arrangement
and watering pipe etc. with charcoal/coke and salt as
Earthing with G.I. earth plate 600 mm X 600 mm X 6
including accessories, and providing masonry
cover plate having locking arrangement and watering
2.7 metre long etc. with charcoal/ coke and salt as
Earthing with copper earth plate 600 mm X 600 mm X
thick including accessories, and providing masonry
with cover plate having locking arrangement and
of 2.7 metre long etc. with charcoal/ coke and salt as
Providing and fixing 32 mm X 6 mm G.I. strip on
surface or in recess for connections etc. as required.
Providing and fixing 32 mm X 6 mm Copper. strip on
surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on
surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm Copper. strip on
surface or in recess for connections etc. as required.
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
5.18 Providing and fixing 6 SWG dia G.I. wire on surface or
in recess for loop earthing along with existing surface/
recessed conduit/ submain wiring/ cable as required
6.2 Providing and fixing of lightning conductor finial, made
of 25 mm dia 300 mm long, G.I. tube, having single
44 prong at top, with 85 mm dia 6 mm thick G.I. base Nos. 1 554.42 554.42
plate including holes etc. complete as required.
6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on
parapet or on surface of wall for lightning conductor
and external lighting complete as required. (For
Horizontal run)
6.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on
46 parapet or on surface of wall for lightning conductor Mtr 35 210.85 7379.72
complete as required. (For vertical run)
6.12 Providing and fixing testing joint, made of 20 mm X 3
mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I.
bolts, nuts, chuck nuts and spring washers etc.
complete as required.
INTELLIGENT FIRE DETECTION AND ALARM SYSTEM - -
17.2.1 Supplying, installation, testing and commissioning of
micro processor based intelligent addressable main
fire alarm panel, central processing unit with the
following loop modules and capable of supporting not
less than 240 devices (including detectors) and
minimum 120 detectors per loop and loop length up to
2 km, network communication card, minimum 320
character graphics/ LCD display with touch screen or
other keypad and minimum 4000 events history log
in the non volatile memory (EPROM), power supply
unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt
maintenance free batteries with automatic charger.
panel shall have facility to connect printer to printout
log and facility to have seamless integration with
analog/digital voice evacuation system (which is part
of the schedule of work under SH: PA System) and
shall be complete with all accessories . The panel shall
be compatible for IBMS system with open protocol
BACnet/ Modbus over IP complete as per
17.2.2 Supplying, installation, testing & commissioning of
central graphical fire alarm management system to
centrally monitor and operate the fire alarm system
complete as required.
17.2.3 Supplying, installation, testing & commissioning of
repeater panel wih 320 character/ Touch screen LCD
display with inbuilt reset, acknowledge and silence
switches complete as required.
17.2.9 Supplying, installation, testing & commissioning of
intelligent addressable thermal detector with rate of
rise cum fixed tempreature thermistor complete with
base as required.
17.2.4 Supplying, installation, testing & commissioning of
intelligent analog addressable photothermal detector
complete with mounting base complete as required.
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
17.2.13 Supplying, installation, testing & commissioning of
intelligent addressable duct detector including suitable
Photo detector complete with base as required
17.2.12 Supplying, installation, testing & commissioning of
addressable beam detector with short circuit isolator
54 (inbuilt or seperate) complete with emitter and receiver Each 2 80,205.07 160410.14
including connections with remote test features etc
complete as required.
17.2.5 Supplying, installation, testing & commissioning of
response indicator on surface/recessed MS Box
having two LED, metallic cover complete with all
connections etc as required.
17.2.14 Supplying, installation, testing & commissioning of
56 addressable manual call point complete as required. Each 5 4,143.13 20715.66
17.2.15 Supplying, installation, testing & commissioning of
addressable horn cum strobe complete as required.
17.2.7 Supplying, installation, testing & commissioning of fault
58 isolator complete with base as required. Each 2 3,499.88 6999.76
17.2.10 Supplying, installation, testing & commissioning of
59 addressable fire control module complete as required Each 2 3,214.11 6428.22
17.2.11 Supplying, installation, testing & commissioning of
60 addressable phone control module complete as Each 1 3,496.67 3496.67
17.2.17 Supplying, installation, testing & commissioning of fire
fighter telephone handset complete as required.
17.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured
cable, 600/1000V rated with annealed copper
62 conductor having XLPE insulation, steel wire Each 300 185.16 55548.57
armouring & FRLS outer sheath complete as required.
Cable End Termination & Pipes -
Supplying and making ends termination with brass
compression glands and aluminium lugs for following
63 size of PVC insulated PVC sheathed -
aluminiumconductor cable of 1.1 KV grade as required
Providing, laying and jointing PVC/RCC NP-2 pipe with
Vin stiff mixture of cement mortar in the proportion of
1:2 (1 cement:2 fine sand) including trenching
(75 cm deep / or as required) i/c testing the joints etc.
in loose soil/under the flooring (before laying the
finished flooring) for electrical cable entrance to the
building complete as required i/c excavation and
refilling of earth.
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Supplying and laying of following size DWC HDPE
pipe ISI marked along with all accessories like socket,
bend, couplers etc. conforming to IS 14930, Part II
complete with fitting and cutting, jointing etc.direct in
ground (75 cm below ground level) including
excavation and refilling the trench but excluding sand
cushioning and protective covering etc., complete as
a 14.16.1 63 mm dia (OD-63 mm & ID-51 mm nominal) metre 100 264.36 26436.41
b 14.16.2 90 mm dia (OD-90 mm & ID-76 mm nominal) metre 5 310.39 1551.94
c 14.16.3 120 mm dia (OD-120 mm & ID-103 mm nominal) metre 5 393.87 1969.35
d 14.16.4 160 mm dia (OD-160 mm & ID-135 mm nominal) metre 80 514.81 41185.14
e 14.16.5 200 mm dia (OD-200 mm & ID-175 mm nominal) metre 5 714.96 3574.80
B NON SCHEDULE ITEMS
DATA /TELEPHONE / TV
Supply and fixing following modular switch/socket on
the existing modular plate and cover plate & switch
box including connections but excluding modular plate
etc. as required.
Information Socket Outlet RJ -45 suitable for CAT 6
Supplying, Installation, testing and commissioning of
following sizes of telephone distribution board in M.S.
67 hinged type box duly painted complete with Krone type
tag block etc. including terminations of cable as
Supplying, Installation, testing and commissioning of
following sizes of 0.5 mm dia annealed tinned copper
68 conductor PVC insulated and PVC sheathed
unarmoured telephone cable on surface/ existing cable
tray complete as required.
b 5 Pair main cable Metre 100 30.00 3000.00
Supply installation testing and commissioning of PBX
system Equipped with 02 Trunk Lines, 20 Extensions,
With built in Auto Attendant,With Built in Caller ID Card
69 for 2 Trunks with all standard accessories software Each 1 35000.00 35000.00
and hardware for proper functioning as required,of
Supplying and fixing following way, Horizontal type
three pole and neutral, sheet steel, MCB distribution
board, 415 volts, on surface/recess, complete with
tinned copper bus bar, neutral bus bar,
interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
a 12 way (4 + 36), Double door, Horizontal Each 1 7826.00 7826.00
SITC of light fixtures suitable for LED fixture, lamps
with all components and accessories including but not
restricted to reflectors, housings, lamp holders and
including cost of ballasts and cost of lamps complete
as required and as below Make:-Bajaj,Havells,Polycab
42Watt LED (600X600MM) of Havells Cat Ref:
a VENUSNEOHE2X2PLR18-42WLED830MOD or Nos. 19 5557.00 105583.00
18Watt LED DOWNLIGHTER of Havells Cat Ref:
VIBEFLRDDLR18WLED830S or equivalent.
15Watt LED DOWNLIGHTER of Havells Cat Ref:
VIBEFLRDDLR18WLED830S or equivalent.
d 18W LED WALL BRACKET LIGHT Nos. 4 2315.00 9260.00
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
20W LED TUBE LIGHT of Havells Cat Ref:
f LUMILINESMART20WLED865PCWH or equivalent. Nos. 25 1852.00 46300.00
15W Mirror Light of Havells Cat Ref:
LUMILINEXS17WLED865SPCWH or equivalent.
25Watt LED (300X300MM) of Havells Cat Ref:
a INTEGRANXTSQDLRSURD24WLED865S or Nos. 32 2130.00 68160.00
10W LED Bulk Head of Havells Cat Ref:
HEXAFT10WLED857SSYMBOPC or equivalent.
g 5W EXIT LIGHT with 1 hr battery backup Nos. 6 4844.00 29064.00
5W STEP LIGHT of Havells Cat Ref:
h RADIANTFTR07WLED830PSYMTOPC or equivalent. Nos. 10 3334.00 33340.00
600 MM INDUSTRIAL WALL AIRCIRCULATING FAN
Supplying of under note sizes of heavy duty exhaust
fans complete with fan motor, blades fixing frame,
72 louver etc as required of havells makes or equivalent.
450 mm exhaust fan 900 RPM Each 4 2968.00 11872.00
Supply, installation, testing and commissioning of 15
kVA,3 Phase input and 3 Phase output UPS
alongwith lead acid batteries giving a back up of min.
30 min. at full load as per specification alongwith all
accessories including interconnecting cables, lugs,
Base Frames, Battery Rack & Battery Circuit breaker,
palral kit complete as required.Make:
Delta/APC/Autometer
The BOQ shall be read in conjunction with general
notes, specification and equipment schedule and
single line diagram.
Supply and installation of the following cubical type
panels ( Partial Type tested ) made of 14 gauge
CRCA structure, base channel, doors & partitions
complete with, Air Circuit Breaker, moulded case
circuit breakers, meters, indicating lamps, current
transformer etc. Complete in all respects, insulated
bus bars with heat shrinkable PVC sleeve in suitable
bus chambers, interconnection, small wiring, name
plate, danger plate, earth bus etc. & comprising of
compartments with hinged door for each feeder & its
accessories, cable alley with hinged doors, bus
chamber with bolted door etc. The panel being of dust
& vermin proof construction with rubber gasket,
attractively powder coated with Siemens grey shade
and having orange peel finish. The panel shall be free
standing type/ wall mounted type as per relevant
drawing, Equipment schedule, specifications including
all materials, accessories, loose supplied items, etc.
required for completeness of the project majorly
comprising of following : -
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
ACB shall have a rated operational voltage of 415V
AC, rated insulation voltage of 1000 volts AC, rated
impulse voltage of 12kV.ACB shall be Moulded Case
design and shall comply with standards IS/IEC 60947-
1 & 2. with Ics = Icu = Icw (1sec) = 50kA.
Both fixed & draw-out circuit breakers shall have single
pole-pitch. ACBs upto 3200A shall be provided with
top horizontal and bottom vertical terminal adapters on
both sides for proper cable connections/bus duct
Shunt trip and closing coil (having common AC/DC
supply upto 250V) shall be continuous rated.
There Should be On, Off, Trip, Spring Charge and
Ready to close Indication lamp for all ACB on the
ACB trip unit shall be EMC/EMI tested and should
have a display for measurement of current and
voltage. It shall be possible to view last 5 trip cause on
trip unit. Separately powered, individual fault trip
indication LEDs (For O/L, S/C, E/F and trip unit failure)
shall be available on the trip unit which shall function
even if the display fails.All ACB shall be EMS
All MCCBS shall be with Extended type Front door
operating handle, Phase Spreaders & Phase Barriers
complying to IS/IEC 60947-1 & 2.
MCCBs shall be current limiting type preferably having
an encapsulated double break design, with rated
operational voltage (Ue) of 415V, insulation voltage
(Ui) of 690 V (AC 50/60 Hz) & impulse voltage (Uimp)
of not less than 8kV.
The electrical life of MCCBs shall be 8,000 operations
up to 250A & 4000 operations up to 630A and shall be
of single frame size upto 250A.Cable Termination on
MCCB should be done using circular lugs being fixed
with a bolt passing through.
For E/F in MCCBs wherever required , external
earthfault module with CBCT should be used with
indication lamp on the panel and fault sensitivity
selection from 20% – 60% In. and time delay selection
in case of Earth Fault from 0.5 to 3 Sec/
instantaneous.All incomer MCCB should be with E/F
protection also.There Should be On, Off, Trip, and
electrical fault trip Indication lamp for all MCCB on the
panel door. Separate fault differentiation indication
(LED) for Over current and Earth fault. Indication for
over current and earth fault tripping shall be extended
to the panel door via indication lamps..All MCCB shall
be EMS compitable.
All MCCBs of ratigs above 250A shall be
microprocessor based and upto 250A shall be
Thermal Magnetic Type and with Min 35 kA Rating .
ON, OFF, Trip and Ready to close status for each ACB
and ON, OFF Trip staus for all Incommer MCCB shall
be avilable on MODBUS.
Control Voltage for Closing / Tripping coils , Spring
charging motor & Indicting lamps in Manually /
Electrically operated ACB Feeder shall be 230 V AC/
Metering CTs burden shall be with suitable VA &
accuracy class .5
CTs shall be "CAST RESIN" type .
All indication lights shall be LED type.
All energy meter shall be "DIGITAL" type with Modbus
Protocol as per techncial Specification
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Panel Manufacturer should have Type Test
Certificates for Short Time withstand current test of
50KA for 1.0 Sec from CPRI. Bhopal / Bangalore.
Control SP MCB's of 2A Rating shall be provided for
each metering circuit.
20% spare control terminal to be provided.
Live parts shall not be accessible after opening the
door, Transparent acrylic sheet to be provided to cover
the same & busbar joints section shall be covered with
All bus bar shall be insulated with coloured PVC
Sleeve i.e. R, Y, B, BK as per colour code.
All internal control wiring shall be heat resistant type.
All TP/TPN feeders shall have solid isolable neutral
All starters shall be provided with Auto/ Manual
selector switch, MPCB/ MCCB/MCB, over load relay,
single phasing preventor, ON/OFF/ Trip/ Trip on
Eclectrical Fault indication lamps, ON/OFF push
Buttons, contractor and suitable No. of Potential free
contacts for remote / local operations, indication,
interlocking and Building Management system.
Current density for bus bar shall not be more than
0.8A/Sqmm. Rating of Bus bar is after considering all
derating factors. (Bus bar sizing calculation to be
submitted for approval.)
All TP/TPN feeders shall have solid isolable neutral
Bus couplers shall be provided with ON & OFF
indicating lights but without releases.
All feeders shall be provided with door interlocked with
door defeat, pad lock facility.
Spare contacts of Relays/Contactor etc. shall be wired
upto terminal block.
Degree of protection for following type of distribution
panel enclosure shall be as per IS:13947-1993.
IP 43 for indoor panels.
IP 55 for outdoor panels.
Contractor and panel builder shall have to submit the
GA drawing and get approval from consultant before
74 MAIN LT PANEL
1 No.200A, 4-pole MCCB
1 No80A, 4-pole MCCB
1 No.200A, 4-pole Contactor
1 No.80A, 4-pole Contactor
Metering & Indication:
Combined Ammeter/Voltmeter with Selector Switch
and 160/5A, CL-1, 10VA CTs and 2A control MCB.
Set of ON/OFF/Trip/Trip Circuit healthy/ready to close
Sets of phase indicating lamp with 2A control MCBs.
All incomer with buscoupler shall be mechanically and
electrically interlock.Consider all necessary software
and hardware for proper functioning of interlocking.It
shall operate auto on and auto off of breaker and then
300A, TPN aluminium, colour coded bus bars suitable
for 415V, 50Hz with fully rated neutral.(After deration)
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
1 Nos.80A, TPN MCCB
4 Nos.63A, TPN MCCB
8 Nos.40A, TPN MCCB
2 Nos.32A, DP MCCB
2 Nos.16A, DP MCCB
2 Nos. Bulb with holder
Panel shall be suitable for incoming & outgoing supply
with cables,and top / bottom entry as required.
Supply & Laying of 1.1KV grade multicore aluminium
conductor XLPE insulated and PVC sheathed
75 armoured cable conforming to IS : 7098 (Part-I) 1998
along walls/ on existing cable trays etc. in an
approved manner and as per follows;
Constructing Masonry chamber 60x60x75 cm (deep)
inside with 75 class designation FPS brick work in
cement mortar 1:4 (1 cement: 4 coarse sand) (for
cable entry) with 10 mm thick M.S. hinged cover plate
on top in 40 x 5 mm MS angle iron frame embedded in
C C 1:2:4 i/c necessary excavation and inside
plastering with cement mortar 1:3 (1 cement:3 fine
sand) finished with a floating coat of neat cement
complete as required and as per specifications
Constructing masonry chamber 60 cm x 45 cm x 50
cm (deep) inside with 75 class designation FPS brick
work in cement mortar 1:4 (1 cement : 3 coarse sand)
(for cable entry) with 10 mm thick M.S. hinged cover
plate on top in 40 x 40 x 5 mm MS angle iron frame
embedded in C C 1:2: 4i/c necessary excavation and
inside plastering with cement mortar 1:3 (1 cement:3
fine sand) finished with a floating coat of neat cement
complete as required and as per specifications
IP CCTV SURVEILLANCE SYSTEM
Supply installation Testing and Commissioing Fixed
Lens Outdoor Bullet Camera - Supplying, Installation,
testing & commissioning of 2MP H.265 NW IR vandal
proof bullet Camera, 0.03Lux (Color), 0Lux (B/W, IR
LED on), 2.8mm fixed lens, 30fps@2M all resolutions,
120dB WDR, H.265, H.264, MJPEG codec supported,
76 DELETED Triple stream , Inbuilt Analytics - Defocus detection, Each 0 32500.00 0.00
Directional detection, Motion detection, Enter/Exit,
Tampering, Virtual line, Audio in , alarm in & out, Micro
SD/SDHC/SDXC memory slot (Max. 128GB), IR
viewable length 20m, IP66, IK10, PoE, CE, FCC, UL,
NDAA complaint, Non-Chinese.
Pelco/ Mobotix/ Avigilon/ Axis / Hanwha
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Supply installation Testing and Commissioing Varifocal
Lens Outdoor Bullet Camera - Supplying, Installation,
testing & commissioning of 2MP H.265 NW IR vandal
proof bullet Camera, 0.03Lux (Color), 0Lux (B/W, IR
LED on), 3.2mm - 10mm Varifocal lens, 30fps@2M all
resolutions, 120dB WDR, H.265, H.264, MJPEG
77 DELETED codec supported, Triple stream , Inbuilt Analytics - Each 0 38500.00 0.00
Defocus detection, Directional detection, Motion
detection, Enter/Exit, Tampering, Virtual line, Audio in ,
alarm in & out, Micro SD/SDHC/SDXC memory slot
(Max. 128GB), IR viewable length 20m, IP66, IK10,
PoE, CE, FCC, UL, NDAA complaint, Non-Chinese.
Pelco/ Mobotix/ Avigilon/ Axis / Hanwha
Supply installation Testing and Commissioing Network
Video Recorder - Supplying, Installation, testing &
commissioning of 16CH NVR , Dual monitor video out
support, H.265, H.264, MJPEG compression support,
ONVIF support, 8 internal HDDs, i/c RJ45 connector i/c
connection etc, supports, N+1 failover, UL, BIS.
complete as required
Pelco/ Mobotix/ Avigilon/ Axis / Hanwha
Supply installation Testing and Commissioing of Client
79 DELETED Viewing Video Sofware. Lot 0 225000.00 0.00
Milestone/ Hanwha / Axis / Pelco
Supply, Installation, Testing and Commissioning of
Surveillance Hard disk - 6 TB Storage. Recording
80 DELETED parameter: 30 days of recording at FULL 1080p, 25fps Each 0 18500.00 0.00
H.264 compression, complete as required.
WD/ Seagate / Hitachi
Supply, Installation, Testing and Commissioning of
Client Desktop PC with Core i7 processor, 8GB RAM, |
TB HDD, Windows 64 bit OS, external DVD writer,
wireless leyboard, wireless mouse, 2GB Graphics card
with dual monitor support, complete with high quality 5
mtrs HDMI cables for connecting displays (2 displays
per unit), complete as required.
HP / Dell / Lenovo
Supply, Installation, Testing and Commissioning of 55"
or better 4K professional displays for 24x7 CCTV
application, complete as required.
LG / Samsung / Benq
Supply, Installation, Testing and Commissioning of
Layer II Smart Managed Gigabit Ethernet switch: 8
83 DELETED port RJ45 10/100/1000 T (POE), , complete as Each 0 19000.00 0.00
Netgear / Cisco / Dlink/Alt global
Supply, Installation and Commissioning of RJ-45 i/o
Jack with Plate & mounting Gang Box, complete as
84 DELETED Each 0 1250.00 0.00
Dlink/ Cisco / AMP / Molex/Legrand
Supply, Installation, Testing and Commissioning of
85 DELETED SFP modules (1G/10G), complete as required. Each 0 4500.00 0.00
Dlink/ Cisco / AMP / Molex
Supply, Installation, Testing and Commissioning of
Networking Rack of 16U along with PDU (With surge
86 DELETED protection), cable manager, fan etc for Switches & Each 0 25000.00 0.00
other accessories etc, complete as required.
Netrack / Valrack
AUDIO VISUAL AND STAGE LIGHTING
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Providing and fixing Line source: 2-way, MF - 15" HF -
1x 1.4", 90° x 50° (H x V), EasyFly rigging system
Frequency Response (-3 dB) 38 Hz - 18 kHz Nominal
Impedance 8 Ohms
Rated Power 750W Continuous, 3000 Peak LF Driver
87 DELETED 15" Drivers, 4" VC - Ferrite Maximum SPL 134 dB HF Pcs 0 221590.00 0.00
Driver 1.5" exit compression driver, 3" VC
Sensitivity 96 dB Crossover Frequency
2.1 kHz or Bi-amplified
Approved Makes - British Acoustics / Martin Audio
Providing and fixing 12" High Performance Passive
Speaker. Frequency Response (-3 dB): 40 Hz - 18
kHz. Frequency Range (-10 dB)
34 Hz - 20 kHz. Rated Power ; 625W Continuous,
2500 Peak. Maximum SPL : 132 dB. Sensitivity : 95
88 DELETED dB. Nominal Impedance : 8 Ohms. Crossover Pcs 0 208642.00 0.00
Frequency : 2.1 kHz or Bi-amplified. Height : 28",
14", Depth : 18", Weight : 23.1 Kgs.
Approved Makes - British Acoustics / Martin Audio
Providing and fixing Subwoofer: LF - 1x 18", Omni-
directional, Cardoid Presets available, Stackable
Frequency Response (-3 dB) 34 Hz - 140 Hz Nominal
Impedance 8 Ohms
Enclosure Marine Birchwood Cabinet, Premium Grade
Frequency Range (-10 dB) 28 Hz - 140 Hz Coverage
Pattern Omni-directional
Grill Perforated Stainless Steel Grill backed by
acoustically transparent foam over a stainless steel
mesh Width 37.5" Rated Power 1000W Continuous,
LF Driver 18" Ultra Low Excursion ADR Drivers, 4" VC -
Ferrite Finish British Acoustics' Signature Brown Finish
Depth 29.3" Maximum SPL 137 dB Inputs
2 x Speak-on Connectors, Wired Parallel
Approved Makes - British Acoustics / Martin Audio
Providing and fixing Loudspeaker Processor, 4-in 8-out
Matrix & Controller. are equipped with a state-of-the-art
32-bit Floating Point DSP, ensuring pristine signal
processing with exceptional accuracy and dynamic
range. With 200 milliseconds of delay capability, you
have precise control over time alignment and phase
adjustments for seamless audio integration.
Approved Makes - British Acoustics / Martin Audio
Providing and fixing 2 Channel Amplifier, 2100 Watts
@ 4 ohms, 1200 watts @ 8 ohms, 4200 watts @ 8
ohms bridge, Sensitivity - 1.4V, Signal to Noise Ratio
91 DELETED (below rated 1 kHz power at 8 ohms) - 103 dB (A- Pcs 0 233234.00 0.00
weighted), THD - < 0.5%
Approved Makes - British Acoustics / Martin Audio
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Providing and fixing Powered 1 x 12 inch stage
monitor, Frequency Response: 50 Hz - 18 kHz,
Continuous SPL: 128 dB/1m, Continuous Power
Handling: 400 Watt, Maximum Power Handling: 800
Watt program / 1600 Watt peak, Dispersion Nominal:
80° x 60° (hor. x vert.), rotable horn or better
Approved Makes - British Acoustics / Martin Audio
Providing and fixing Speaker Brackets : For Hanging
arrangement of Speaker complete in all respect as
93 DELETED specified or indicated including testing on completion. Pcs 0 3658.00 0.00
Approved Makes - British Acoustics / Martin Audio
/Meyer Sound / Custom
Providing and fixing of Dressing Room Speaker ( Make
& Female ): Frequency range (-10dB) : 80Hz - 20kHz ,
Nominal coverage : H(90) X V (90 ) , Components :
6.5"(160mm) cone driver , 1"(25mm) balanced dome
tweeter , Power rating : PGM 50W , Nominal
impedance : 8Ω / 15W, 7.5W, 3.8W , SPL : 110dB
SPL (100W), complete in all respect as specified or
indicated including testing on completion.
Approved Makes - British Acoustics / Martin Audio
Providing and fixing of Power amplifier for Dressing
Room Speakers : Output power : 1kHz (THD+N=1%:
3Ωm /4Ω) : 30W x 2 (20ms Burst) , High impedance:
100V line : 60W x 1 , Total harmonic distortion : ≤
0.1% (Line in to Speaker out 1kHz, 15W,3Ω/4Ω), ≤
0.2% (Line in to Speaker out 1kHz, 30W, 70V/100V)
95 DELETED ,Frequency response : 0dB, -3.0dB, +1.0dB (Line in to Pcs 0 168672.00 0.00
Speaker out,50Hz to 20kHz, 1W, 3Ω/4Ω), 0dB, -3.0dB,
+1.0dB (Line in to Speaker out, 90Hz to 20kHz, 1W,
70V/100V), complete in all respect as specified or
indicated including testing on completion.
Approved Makes - British Acoustics / Martin Audio
Providing and fixing 32 Channel Live Mixing Console
No of Input Channels Total 32 (28 Mono + 2 Stereo)
-10 dB to +60 dBu (including Pad), No of Output
Channels Master (L/R), 4 Groups, 3 Auxes & Phones
Frequency Response 20 Hz - 20 kHz (3 dB Phantom
Power +48V on individual channels with a central
Approved Makes - British Acoustics / Martin Audio
Providing Wired Microphone : Microphone Unit
Dynamic ; PolarPattern Unidirectional ; Frequency
Response 40 Hz–15 kHz ; Sensitivity (2.83 V/1 m) -
54dB ±3dB (0 dB=1V/Pa at 1 kHz) ; Output Impedance
97 DELETED 500 ohms ±30% (at 1 kHz) ; Connector 3 pin XLR-M Pcs 0 25764.00 0.00
type ; Cable Φ6mm x 5m cable with XLR-F type
connector and6.3mm plug, complete in all respect as
specified or indicatedincluding testing on completion
Approved Makes - OSL/Sennheiser/Shure
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Providing Handheld wireless microphone : Wirless
Handheld UHF true diversity wireless system, cpl. with
NE 600 S and SDM 669, PLL, pilot tone, ACT/SCAN-
function, 16 preprogrammed frequencies, incl.
softcase, batteries, rack mount brackets, MKV 11 and
switching power supply complete in all respect as
specified or indicated including testing on completion.
Approved Makes - OSL/Sennheiser/Shure
Providing Lapel microphone : Wireless Lapel UHF true
diversity wireless system, cpl. with NE 600 S, TS 601
and TG L55c lavalier microphone, PLL, pilot tone,
ACT/SCAN-function, 16 pre- programmed frequencies,
incl. softcase, batteries, rack mount brackets and
switching power supply complete in all respect as
specified or indicated including testing on completion.
Approved Makes - OSL/Sennheiser/Shure
Providing of Gooseneck microphone: Condenser
gooseneck mic (cardioid), black, length 500 mm (20''),
two flexible segments, 3-pin XLR male, with
100 DELETED preamplifier, windscreen included. Complete in all Pcs 0 33462.00 0.00
respect as specified or indicated including testing on
Approved Makes - OSL/Sennheiser/Shure
Providing & laying Speaker Cable : Cable with
thickness of 2 Core 2.5 Sqmm including conduit
101 DELETED complete in all respect as specified or indicated Mtr. 0 172.00 0.00
including testing on completion.
Approved Makes - NETMAS/Krystals/KRAMER
Providing & laying Microphone Cable : Cable with
thickness of 2 Core 1.5 Sqmm including conduit
102 DELETED complete in all respect as specified or indicated Mtr. 0 152.00 0.00
including testing on completion.
Approved Makes - NETMAS/Krystals/KRAMER
Mic Stand Big -
Approved Makes - G.S./Acoustika/NETMAS
Mic Stand Small -
Approved Makes - G.S./Acoustika/NETMAS
Providing & laying snake Cable : Snake Cable 24/22
AWG 16Pair stranded (7x32) TC conductor, polyolefin
insulation, individually shielded Beldfoil® (100%
105 DELETED coverage) numbered/color-coded PVC jackets, jackets Mtr. 0 988.00 0.00
and shields bonded to strip simultaneously, overall
Beldfoil shield and 24 AWG TC drain wire.
Approved Makes - NETMAS/Krystals/KRAMER
Providing and fixing of Stage Box for mics connectivity -
Approved Makes - Krystals / Acoustika/NETMAS
Providing and fixing of interconnectivity Connectors lot
107 DELETED make- Nos. 0 64900.00 0.00
Approved Makes - Krystals / Acoustika/Neutric
Providing and fixing of Network Rack custom -
Approved Makes - custom/Dell / Netrack
DELETED VIDEO SYSTEM
Providing and fixing of 6,000 lumen* laser projector
with fixed lans Beautifully slim, light and stylish, the
VPL-PHZ60 laser projector combines outstanding
picture performance with impressive 6,000 lumen*
109 DELETED image brightness and dependable reliability. With Nos. 0 493830.00 0.00
discreet blend-in styling, minimal maintenance needs
and flexible installation options,Number of
Pixels6,912,000 (1920 x 1200 x 3) pixels
Approved Makes - JV / Barco /Sony
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Providing and fixing of Motorized tab tenion screen
with remote control size 144" x 90" diagonal 170" aprx.
aspect ration 16:10
Approved Makes - AGT / Grandview / elite/Suvera
Providing and fixing of Hanging arrangement for
screen Make- Custom
Providing and fixing of Wallplate Transmitter over Cat
6( HDBaseT) upto 70 meter with Inputs 1 HDMI, 1
USB-C & 1 Cat6 (HDBaseT) Output, 2K and 4K
support, HDCP 1.4 & 2.3 both Compliant, Up to 60W
USB–C charging on USB-C input, PoE acceptor,
112 DELETED stereo audio output, 1 RS-232 for device control & 1 Nos. 0 148018.00 0.00
RS232 for serial link extension over HDBaseT output,
Safety Regularity Compliance : CE, RoHs and WEEE,
ISO 9001, ISO 14001, ISO 27001:2013 etc complete
Approved Make- Kramer / Milestone
Providing and fixing of HDMI Receiver over Cat 6 (
HDBaseT) up to 70m with Inputs 1 Cat6 (HDBaseT), 1
HDMI Output, 2K and 4K support, HDTV Compatible,
113 DELETED HDCP 2.2 Compliant with IR and RS-232, Compliance Nos. 0 68734.00 0.00
: CE, ISO 9001, ISO 14001, OHSAS 18001, etc
complete as required.
Approved Make- Kramer / Milestone
Providing and fixing of Transmitter over Cat 6 (
HDBaseT) up to 70m with Input 1 HDMI, 1 Cat6
(HDBaseT) Output, 2K and 4K support, HDTV
114 DELETED Compatible, HDCP 2.2 Compliant with IR and RS-232, Nos. 0 68734.00 0.00
Compliance : CE, ISO 9001, ISO 14001, OHSAS
18001, etc complete as required.
Approved Make- Kramer / Milestone
Providing and fixing of 4K@60Hz 4:4:4 Switcher 4
HDMI inputs, 1 HDMI Output with de-embedded
analog audio, 2K and 4K support, Min. data rate data
rate of 17.82Gbps, HDTV Compatible, HDCP 2.2 &
115 DELETED HDR10 Compliant, Automatic Switching, 1 Nos 0 101171.00 0.00
Unbalanced Stereo Audio: On a 3.5mm mini jack,
Controllable through contact closure switches, etc
complete as required. Approved Make- Kramer /
Providing and fixing of HDMI cable 4-5 pieces One
116 DELETED Meter to Two Meter HDMI & Cat 6 cable, Approved Lot 0 7670.00 0.00
Make- Kramer / Milestone
DELETED STAGE LIGHTING
SITC of LED par 54 x 3 RGBW indoor Light source :
54PCS 3W LEDs(R12 G12 B12 W18) Lens angle :
25º(30º, 45º, 60º optional) Channel mode : 3 / 4 / 6 / 7
/ 9DMX channel mode 0-100% linear dimmer Function
: color mix, automatic color change, built-in program
and strobe effect with adjustable speed Sound
controlled via built-in microphone
Adjustable sound sensitivity LED Display, easy to
control Control : auto, sound active, DMX512,
software(connect to computer) Overheating protection
Voltage : 100-220V,50/60hz Power : 180W
Make PLS/ DL&MC/Robe
SITC of PC spot 200 watt original citizen led lamp
flicker free led light source 1 Pc. 200 watt COB LED
(WWCW) zoom DMX control lamp average life time
50,000 hours DMX channel 2/3/4 channel control
mode DMX 512 software (connect to computor)
manual control dimmer 100% linearly adjustable
strobe 0 - 25 FPS angle 15 to 50 digree
Make PLS/ DL&MC/Robe
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
SITC of Profile light LED 200W PROFILE WITH
PLASTIC HOUSING (26 DEGREE)Lux@2m 11000
Lux Lux@4m 2700 Lux Lux@6m 1190 Lux Lux@8m
LED Qty 1pcs of 200W LED Drive current 5A Color
temperature 3200K (warm White)
On-board Control Four Display Control Protocol
DMX512 CRI 80 Channel Mode 1CHs Dimmer
0~100% Beam Angle 26º (19ºOptional)
Make PLS/ DL&MC/Robe
SITC of 24x 12 RGBW Light source : 24PCS 12W 4 IN
1 LEDs Lens angle : 25º(30º, 45º, 60º optional)
Channel mode : 3 / 4 / 6 / 7 / 9DMX channel mode
0-100% linear dimmer Function : color mix, automatic
color change, built-in program and strobe effect with
adjustable speed Sound controlled via built-in
Adjustable sound sensitivity LED Display, easy to
control Control : auto, sound active, DMX512,
software(connect to computer) Overheating protection
Voltage : 100-220V,50/60hz Power : 300W
Make PLS/ DL&MC/Robe
SITC of Fresnel light 150w COB LED Drive Current 5A
Color Temperature 3200k
CRI 97 Input Voltage 100-240VAC Power 160W on-
board Four digital display Control Protocol DMX512
DMX Channel 2Chs Dimmer 0-100% lux@2m
(Minimum facula) - 7500 Lux @4m (Minimum facula) -
2130 Lux lux@6m (Minimum facula) - 970 Lux
lux@8m (Minimum facula) - 550 Lux lux@2m
(Minimum facula) - 217 Lux lux@4m (Minimum facula) -
578 Lux lux@6m (Minimum facula) - 270 Lux lux@8m
(Minimum facula) - 165 Lux
Make PLS/ DL&MC/Robe
SITC of fog machine With the latest technology of the
heater, the ZB-3000 has better effects as a fog
machine Power : 3000W Heat-up Time : 12 minutes
122 DELETED Fluid consumption rate : 45min/L (100% output), 0 Nos 37996.00 0.00
2hours/L (30%output) Tank capacity : 10L
Circuitry Contro : Remote Control DMX : 512 Control
Make PLS/ DL&MC/Robe
SITC of 400W LED Blinder Light . 400W LED Blinder
Light 30 Degree complete with 3200K/5600K CCT
4x100W Chip On Board LED lamp source, DMX 512
dimming with 4/8 Channel modes, Black finish
housing, IP20 protection having Strobe option and
smooth dimming, illuminate Stage with uniform light
intensity levels
Make PLS/ DL&MC/Robe
SITC of DMX splitter 1 in 10 out Voltage : 100-
220V,50/60hz Power : 4W IP rating : IP20 isolated
DMX output ports 3pin XLR inputs & outputs 10
124 DELETED isolated outputs 0 Nos. 18172.00 0.00
DMX loop through port with inbuilt termination
Universal power supply
Make PLS/ DL&MC/Robe
SITC of XLR connectors Make-
PLS/DL&MC/Acoustika
SITC of DMX cable 24 AWG (25/0.10mm) x 2 core
ATC copper conductor, PE insulated, core twisted in a
circular form, covered with special moisture-proof
polymer, spiral shielded (97%) with ATC copper, outer
Jacketed with Matt finish High Flex Special PVC.Make-
Netmas/ Krystals/Tasker
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
127 DELETED SITC of light clamp for stage light Make- Custom 0 Nos. 590.00 0.00
SITC of Stage light light point Wiring from light points
to MCB box wire 2.5 Sq.mm 3 Core PVC Insulated
and PVC Sheathed Cable including of suitable size 5/6
128 DELETED amps sockets with box at top sutable MCBs and MCB 0 Nos. 3304.00 0.00
box. Electrical cable make- Polycom/Havells/eq.
Socket, top and MCBS make-
Anchor/Schnieder/Havells/Hager
Supply of 4 Side ladder made out of 25 x 50 mm
flate ms pipe Make- Tata/Jindal/Apollo
130 DELETED SITC of 50 mm MS pipe light bar 0 Nos. 26550.00 0.00
SITC of Mini Perl 1024 Supply of Light Controller
Computer Light Controller,Product Model:Mini Pearl
Voltage 100 to 240 V Frequency 50/60 Hz Mating
number of Fixtures 96 The Number of Scenes That
Can be Saved 60 The Number of Scenes That Can
Run Simultaneously 10 The Total Number of Steps in
a Multi Step Scenario 600 Scene Time Control Fade
In, Fade Out LTP Sliding Graphics Can be Stored for
Each Scene 5 Fader Scenes/Dimming Size 485 x
420 x 105 cmProduct Description Leveraging the skills
of our qualified team of professionals, we are
instrumental in offering a wide range of Mini Pearl
1024 Lighting Controller.
PLS/DL&MC/Acoustika
EXTERNAL LIGHTING
Supplying and fixing (with suitable MS clamp) 300mm
132 long 65mm dia MS pipe with base plate i/c nipple each 2 3384 3386.00
for Gate light.
Supplying, installing, testing & commissioning of 4.5
Mtr long single dip Galvanised steel
octagonal poles in 3mm sheet integrated
connector box inside the pole containing one no.
5A MCB , Neutral link and earth terminal with single
over hang bracket 1m long ; providing and
fixing in position 1:2:4 reinforced cement
133 concrete foundation for the pole, size each 15 28000 28015.00
500mm(L)X500mm(W)X 1650mm deep i/c excavation
of earth, providing, cutting, bending and placing in
position reinforcement as per drawing and providing
PVC flexible pipes 50mm dia for cable entry and
exit as required i/c foundation bolts, transportation,
handling, marking etc. as per specification and
drawings as required of Havells/ Bajaj or equivalent
Supply and installation of following arms suitable for
4.5 Mtr to 9 mtr street light pole
a Single Arm over hang bracket 1mtr length each 12 3384 40608.00
b Double Arm over hang bracket 1mtr length each 3 4600 13800.00
Providing and erection of black painted galvanized 3
meter high poles in different section, top 60mm dia.,
bottom 100mm dia. with gold colour painted
ornamental cast aluminium ring having lockable
weather proof flush door junction box in bottom
section, and suitable arrangement for installation of
CCTV and with base plate dia. 290mm having 4 holes
of 22mm dia. complete erected in an approved
manner including foundation of Suitable size & type of
foundation bolts as required. (For CCTV)
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
supply & drawing 3 core 2.5 sqmm
unarmoured copper cable inside the GI
136 Octagonal pole from connector box to the light Set 15 1083 16245.00
fixture including connections with thimbles as required
upto 9m high pole
Supplying and fixing (with suitable MS clamp) 1200mm
long vertically and 900mm inclined at 45 degree,
65mm dia MS pipe with hardware i/c nipple for
street light.(boundary wall light)
Supplying and fixing of LED Bollard Fitting 600mm
High with IP65 and IK07 Housing made up of
aluminum pipe powder coated black after
phosphochromate treatment with aluminum heat sink
for effective thermal management Complete with
Mounting Brackets & accessories as required with
connections similar. Havells Mount Bollard 0.60 mtr
MOUNTBLMINIMOUNTBL10WLED830PSYMTOPMM
AS . The product should be BIS approved with R
number mentioned on product label. To be supported
with Product test reports - LM79, Is 10322/IEC 60598
and for LEDs - LM80, RoHS and Photo Biological
Safety certificate.
Supplying and fixing of Spike Light LED of Havells cat
no. IRVINESPS5WLED830PSYMTG or equivalent.
Supply, fixing &testing of prewired external light
fixture having Die-cast housing with epoxy
coating and having profiled cooling fins at the top
for effective heat dissipation, separate driver and
LED lamp cavity, heat resistant toughened clear
glass cover with high transmittance and high
quality gasketing system, high power LED complete
25 Watt LED Fitting Lighting lantern on GATE/ POST
TOP of Havells Cat
no.CORALMINIPT15WLED757PSYMTOPC or
Street Light Luminare of 60 watt LED including
suitable fixing MS clamps etc.as requird of Havells Cat
No. ENDURASUNDOWNSL60WLED765PASYBOTG
Street Light Luminare of 35 watt LED including
suitable fixing MS clamps etc.as requird of Havells Cat
No. ENDURASUNDOWNSL35WLED765PASYBOPC
Floodlight LED luminaire 50 Watas with high
pressure die cast housing with IP66 deg of
v protection of Havells Cat No. each 6 5429 32574.00
JETAQUANTOPLUSFLP50WLED757SYMLENS or
Supplying, Installation, testing and commissioning of
70KWP grid interactive roof top solar photo voltaic
power generation system including mountning
structure,solar panel,inverter,DC and AC distribution
141 DELETED box/ Junction box,suitable rating of Ac and DC Set 0 650000 0.00
cabling,earthing,Lightning arrester,controlling and
other necessary software and hardware as required for
proper generation and distribution of solar power into
COMMUNITY CENTRE ENGINEERING CONSULTANCY SERVICES
2022 Rate Amount
S.No. Description Unit Qty
Code / (In Rs.) (In Rs.)
Design, supply at site, installation, testing &
commissioning of 3-phase, 415 volt, 1500 RPM, 50
HZ, Diesel generator set with prime rating capacity of
following KVA at 0.8 pf lagging diesel engine
alternator set mounted on common base frame in
outdoor type acoustic enclosure , day tank capacity of
990 litres,m with AMF Panel,battery, batter charger,
return fuel cooler, anti vibration mounting pads
including residential silencer, engine alternator, pcc
142 DELETED based auto start & synchronization set, safeties with
accessories as per specification complete as required.
Diesel engine shall conform to IS:10000 and alternator
shall be self excited complete with AVR to IS:4722.and
updated at the time of execusion.Contractor and
manufacturer shall have to submit GA drawing for
approval to engineer in charge before
implementing.Also arrange testing schedule at factory
with engineer in charge and client.
a DELETED 40KVA Set 0 450000 0.00
DSR TOTAL Rs. 26,04,336.37
Adding GST 18% against 12% @ 1.0633 27,69,190.87
NON DSR TOTAL Rs. 17,58,783.00
DSR + NON DSR TOTAL Rs. 45,27,973.87
stage.html
html • 0.05 MB
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
1 NIT 151.pdf
Tender Document
2 BOQ.pdf
Tender Document
SCC R1.pdf
Tender Document
4 SCOPE OF WORK.pdf
Tender Document
5 IP.pdf
Tender Document
6 Milestone.pdf
Tender Document
7 GCC PMC 2022 AMEND 1 TO 12.pdf
Tender Document
8 List of Approved Make.pdf
Tender Document
9 Technical circular.pdf
Tender Document
corrigendum-3904-NIT 151 2.pdf
pdf • 0.12 MB
addendum-70476b2abc17-Corri-1 151.pdf
pdf • 0.09 MB
corrigendum-3777-Corri-1 151.pdf
pdf • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .