Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L I₹8.6 LAccepted-AOC CHIEF ENGINEER OP KANGRA ZONE HPSEBL DHARAMSHALA | KANGRA | HIMACHAL PRADESH | 175013 | L I | Accepted-AOC Award | |
| 2 | L II₹9.4 LRejected-AOC UPPER BAZAAR BHAWARNA TEHSIL PALAMPUR DISTT KANGRA H P | L II | Rejected-AOC Not award | |
| 3 | L III₹10.0 LRejected-AOC VILL BHAI PO DAULATPUR TEH AND DISTRICT KANGRA 176031 | KANGRA | KANGRA | HIMACHAL PRADESH | 176031 | L III | Rejected-AOC Not award |
Tender Value
₹10.6 L
EMD Value
₹26,532
Closing Date
20 Sept 2021, 4:00 pmClosed
SE OPERATION CIRCLE KANGRA
SE KANGRA
ELECTRICAL WORKS
2021_HPSEB_52317_1
SEOP 17/2021-22
Open Tender
Electrical Works
Turn-key
90 days
KANGRA
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,800
₹26,532
13 Oct 2021
15 Sept 2021
22 Sept 2021
15 Sept 2021
20 Sept 2021
15 Sept 2021
Amount
11 KV H T line
Prov.Steel Tubular pole 10 mtr.long w/L 200 Kg.
Prov.Steel Tubular pole 9 mtr.long w/L 200 Kg.
Prov.RCC Muff with concerete feeling
Prov A.I.Knee bracing set 2x(750x50x50)mm for single pole
Prov. C.I.X-arm 1500 x 100x50 mm single pole
Prov. A.I.X-arm 2800 x 50x50 mm for Guarding
Prov. C.I.X-arm 2400 x 100x50 mm for double pole
Prov. A.I bracing set for double pole str. 2x(1500 x 50x50) (2700x50x50) mm
Prov. Pin Insulator with pin hellically formed fitting (set of 3 No.)
Disc Insulator set cleaves and tongue helically formed fitting
Prov. H.T.Stay set Complete
Prov. Stay wire 7/3.15 mm ( @ 6.0 kg Per Stay set )
Prov Coil earthing
Prov G.I.wire 8 SWG for guarding Across the road
Danger Plate ( 203x200x1.6mm)
G.O Switch 400 amp
Prov. Nut & Bolt ( off sizes )
Barbed wire
Aluminum Paint
Prov.AAAC 7/3.15mm ( 50mm2 )
Prov. Earth Hook HT 8" Long
250KVA S/Stn
11/0.4 KV 250 KVA Distribution Transformer
S/T Pole 9Mtr. W/L 200 kg (2 Nos. for Transformer)
RCC Muff for 9 mtr. Long pole with concerete filling
X-arm channel iron (100x50xx6 mm) Length 2800mmx2nos
X-arm channel iron (75x40x6 mm) Length 2800mmx4no for supporting of do fuse unit and go switch
AAAC7/4.26mm2
Angle for (50x50x6mm)
Aluminum thimble
Aluminium thimble
chain link fencing angle iorn gate for transformer fencing
A.I X Arm for Lightning Arrestor (2800x50x50 mm)
G.O. Switch 400 Amp.
D.O. Fuse
Lightning Arrestors
Disc Insulator with fitting
Pin Insulator
Stay Set Complete
Stay Wire 7/3.15 mm (@8.0 kg Per Stay Set)
Pipe Earthing
Half Clamp (M.S. Flat 50x6 mm)
M.S. Nuts and Bolts (off Sizes)
G.I Thimble
Lead tin Solder
Solder Flux
Danger Plate
Barbed Wire
LT distrubution panel Box with ACB (630 A, 50 KA, 1 No. & SFU (150 A, 6 No. rewireable)
LT Cable(3.5 Core) 300 mm
3 phase 4 wire LT PT Trivector Meter
Aluminum Paint
CT PT Unit (PT:11 KV/110V)(CT:10-400/5)
3 phase 4 wire CT PT Operated HT Meter
Control cable for Trivector meter
Civil work i.e. Transformer plint and Fencing etc.
C.I X-arm for CT PT
LT line
Prov. Steel Tubular Pole 8 Mtr. Long
Prov. RCC Muff .
Prov. Eye Hook Bolt
Prov. LT Stay Set Complete
Prov. Stay Wire 7/3.15mm
Prov. G.I Wire 8 SWG
Prov. M.S Nuts and Bolts (Off Sizes)
Prov. Aluminium Paint
Prov. Stay Clamp
Prov. LT AB Cable 95 MM2
Plinth
Excavation in foundation,trenches etc.in earth work, lift upto 1.50 metres stacking the excavated soil not more than 3 meters clear from the edge of the excavation and then returning the stacked soil in 15 cm.layers, when required in to plinth sides of foundations etc. and then disposing of all surplus excavated earth as directed with in a lead of 20 mtrs. (PW/JW ). 50% each
Providing and laying Cement concrete 1:6:12 (1Cement:6 Sand: 12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of centring and shuttering in: foundation and plinth
Providing and laying Cement concrete 1:2:4(1Cement:2 Sand:4graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work foundation and plinth
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give fair finish i/c centring,shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs etc.In (i) vertical surface such as walls (any thickness) partitions and the like.
fencing
Excavation in foundation,trenches etc.in earth work, lift upto 1.50 metres stacking the excavated soil not more than 3 meters clear from the edge of the excavation and then returning the stacked soil in 15 cm.layers, when required in to plinth sides of foundations etc. and then disposing of all surplus excavated earth as directed with in a lead of 20 mtrs. (PW/JW ) 50% each
Providing and laying Cement concrete 1:2:4(1Cement:2 Sand:4graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work foundation and plinth
Steel work in single section i/c cutting, hoisting, fixing in position and applying a priming coat of red paint in R.S. joists, channels, angles etc.
Supply and fixing wovenplane G I wire fencing of mesh 50mm to 150mm to any type of standard rails, straining bolts.etc. including provision of binding wire staples etc.
P/F M.S pressed butt hinges with necessary screws -75 x 47 x 1.70mm
Providing & fixing oxidized M.S. sliding door bolt with bolts and nuts, screws etc. complete (Size 250x16mm)
Novelty Enterprises
MS Sonu Kumar A Class Govt Cont
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .