Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹111.7 CrAccepted-AOC | ₹111.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹117.4 CrRejected-Finance 610B NILGIRI BLOCK ADITYA ENCLAVE AMEERPET HYDERABAD 500038 | HYDERABAD | TELANGANA | 500038 | ₹117.4 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹121.2 CrRejected-Finance B 22 2ND FLOOR HIMALAYA HOUSE 23 K G MARG CANNAUGHT PLACE NEW DELHI 110 001 | NEW DELHI | DELHI | 110001 | ₹121.2 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹123.2 CrRejected-Finance | ₹123.2 Cr | L4 | Rejected-Finance L4 |
| 5 | L5₹130.8 CrRejected-Finance NOT SPECIFIED | ₹130.8 Cr | L5 | Rejected-Finance L5 |
Tender Value
₹122.4 Cr
EMD Value
₹20 L
Closing Date
9 Sept 2024, 5:00 pmClosed
Managing Director, CIAL
Managing Director, Cochin International Airport Ltd. Kochi Airport P.O. Ernakulam - 683111. Kerala. India.
Construction of commercial zone at CIAL SH Civil and MEP works
2024_CIAL_685090_1
CIAL/CIVIL/597A/E18
Open Tender
Civil Works - Buildings
730 days
Cochin International Airport
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹20 L
ED meeting room, CIAL
9 Oct 2024
10 Aug 2024
11 Sept 2024
10 Aug 2024
9 Sept 2024
21 Aug 2024
10 Aug 2024 - 15 Aug 2024
19 Aug 2024
Amount
CIVIL WORKS Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 5 km outside the periphery of the area cleared. as directed by the engineer in charge
Felling trees of the girth (measured at a height of 1 m above ground level),including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material to lead of 5 km and as directed by the engineer in charge.Beyond 30 cm girth upto and including 60 cm girth
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 M2 on plan) including getting out and disposal of excavated earth within a lead of 5 Km and level the same and lift upto 1.50 m as directed by Engineer-in-charge. All kinds of soil :- (for I Lift 0 - 1.5m) From 0.00 M to 1.50 M depth
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 M2 on plan) including getting out and disposal of excavated earth within a lead of 5 Km and level the same and lift from 1.50 m to 3.00m as directed by Engineer-in-charge. AAll kinds of soil :- (for II Lift 1.5 - 3.0m) From 1.50 M to 3.00 M depth
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 M2 on plan) including getting out and disposal of excavated earth within a lead of 5 Km and level the same and lift from 3.00m to 4.50m as directed by Engineer-in-charge. All kinds of soil :- (for III Lift 3.00 - 4.5m) From 3.00 M to 4.50 M depth
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 M2 on plan) including getting out and disposal of excavated earth within a lead of 5 Km and level the same and lift from 4.50m to 6.00m as directed by Engineer-in-charge. All kinds of soil ::- (for IV Lift 4.5 - 6.00m) From 4.5 M to 6.00 M depth
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto1.50m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 5 Km and level the same.As per standards, specifications and directed by the Engineer-in-Charge. All kinds of soil ( Including disintegrated rock / weathered rock / soft rock.):l:- (for I Lift 0.00- 1.50m) From 0.00M to 1.50 M depth
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift from 1.50m to 3.00m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 5 Km and level the same. As per standards, specifications and directed by the Engineer-in-Charge. All kinds of soil :- (for II Lift 1.5-3.0m) From 1.50M to 3.00 M depth.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift from 3.00 m to 4.50m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 5 Km and level the same.As per standards, specifications and directed by the Engineer-in-Charge. All kinds of soil :- (for III Lift 3.00- 4.5m) From 3.00M to 4.50 M depth
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift from 4.50m to 6.00m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 5 Km and level the same .As per standards, specifications and directed by the Engineer-in-Charge. All kinds of soil ::- (for IV Lift 4.5-6.0m) From 4.50M to 6.00 M depth
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift from 6.00 to 7.50m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 5Km and level the same . As per standards, specifications and directed by the Engineer-in-Charge. All kinds of soil :- (for V Lift 6.00-7.50m) From 6.00M to 7.50 M depth
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift from 7.50 to 9.00m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 5 Km and level the same.As per standards, specifications and directed by the Engineer-in-Charge. All kinds of soil :- (for VI Lift 7.50-9.00m) From 7.50 M to 9.00 M depth
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers,consolidating each deposited layer by ramming and watering, lead upto 5kms and lift upto 1.5 m. As per standards, specifications and directed by the Engineer-in-Charge.
Supplying and filling in plinth with M sand under floors, including watering, ramming, consolidating and dressing complete at all levels .As per standards, specification and directed by the Engineer-in-charge.
Disposal of Earth/moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading and levelling the same for lead upto 5Km for all lifts,As per standards, specification and directed by the Engineer-in-charge.
De-Watering - Extra rates for quantities of earth works, executed: In or under water and/or liquid mud, including pumping out water as required From 3.00M to 4.50 M depth
De-Watering - Extra rates for quantities of earth works, executed: In or under water and/or liquid mud, including pumping out water as required From 4.50M to 6.00 M depth
De-Watering - Extra rates for quantities of earth works, executed: In or under water and/or liquid mud, including pumping out water as required From 6.00M to 7.50 M depth
De-Watering - Extra rates for quantities of earth works, executed: In or under water and/or liquid mud, including pumping out water as required From 7.50M to 9.00 M depth
Sheet Pilling Driving M.S. sheet piles for shoring of any kind of approved type and size conforming to IS code in all kinds of soil/ soil mixed with gravel, shingle & pebbles, by monkey hammer including handling, cutting to requisite size, drilling holes, hoisting in position, welding, fabrication of sets of tapper piles, corner piles etc. with clutch bars as may be required including staging, scaffolding and hire charges of driving machinery,sheet piles and equipments, painting the surface with one coat of surface primer of approved make and brand and two coats of ready mixed oil bound paint (except red lead and black japan) etc including all cost of labours, supply and carriage of equipments to site (by any mean) as per drawing and direction of EIC. Design and vetting of shoring shall be under the scope of the contractor and shall be submitted before execution. The material shall be taken out after the completion of the construction by the contractor.
PILING WORKS Empty Boring for bored cast- in - situ reinforced cement concrete pile of specified diameter and length below the pile cap , and including the cost of boring with, bentonite solution and temporary casing of appropriate length for setting out and removal of same and including removal of excavated earth with all lifts and leads (Length of boring for payment shall be measured from the piling level up to the pile cut off level) For 500mm dia Piles
PILING WORKS Empty Boring for bored cast- in - situ reinforced cement concrete pile of specified diameter and length below the pile cap , and including the cost of boring with, bentonite solution and temporary casing of appropriate length for setting out and removal of same and including removal of excavated earth with all lifts and leads (Length of boring for payment shall be measured from the piling level up to the pile cut off level) For 600mm dia Piles
Cast in situ bored RCC Piles Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine/ tractor mounted or Rotary Boring all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap) with a socketing depth of minimum 50cm. Pile depth as shown in drawing - For 500mm dia Piles
Cast in situ bored RCC Piles Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine/ tractor mounted or Rotary Boring all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap) with a socketing depth of minimum 60cm. Pile depth as shown in drawing - For 600mm dia Piles
STATIC LOAD TEST Conducting Static load test (Reaction frame method) in accordence to IS 2911, on various pile diameters as specified in the drawing and specification including supply of structural steel, fabrication & erection of cantliedge, loading the cantiledge for specified capacity, suitable capacity crane for loading of cantiledge, acceleration and displacement / velocity transducers to record both force and velocity and including necessary excavation, dewatering, preparation (building) of pile head including building up of pile, additional reinforcement if any etc. all complete as per approved methodology, specifications, in strict accordance to the relevant code provisions, generation of the test reports and as per instructions of the Engineer for piles of following diameter and safe vertical load carrying capacity. For 500mm dia Piles
STATIC LOAD TEST Conducting Static load test (Reaction frame method) in accordence to IS 2911, on various pile diameters as specified in the drawing and specification including supply of structural steel, fabrication & erection of cantliedge, loading the cantiledge for specified capacity, suitable capacity crane for loading of cantiledge, acceleration and displacement / velocity transducers to record both force and velocity and including necessary excavation, dewatering, preparation (building) of pile head including building up of pile, additional reinforcement if any etc. all complete as per approved methodology, specifications, in strict accordance to the relevant code provisions, generation of the test reports and as per instructions of the Engineer for piles of following diameter and safe vertical load carrying capacity. For 600mm dia Piles
DYNAMIC PILE LOAD TEST Carrying out high strain Dynamic pile load test on bored reinforced concrete Cast-in-situ piles as per ASTM D 4945 and Institution of Engineers code to evaluate the pile capacity and structural integrity of pile including net and total settlement of under displacement the measured capacity along with other related tests and submission of report,including cost of all necessary excavation, deployment of suitable capacity crane back filling, disposal of material, equipment & labour, and chipping of piles / building of piles as the case may be including surface preparation to the complete satisfaction of the Consultant. The contractor shall submit the dynamic pile load test methodology / procedure to the consultant for his approval. For 500mm dia Piles
DYNAMIC PILE LOAD TEST Carrying out high strain Dynamic pile load test on bored reinforced concrete Cast-in-situ piles as per ASTM D 4945 and Institution of Engineers code to evaluate the pile capacity and structural integrity of pile including net and total settlement of under displacement the measured capacity along with other related tests and submission of report,including cost of all necessary excavation, deployment of suitable capacity crane back filling, disposal of material, equipment & labour, and chipping of piles / building of piles as the case may be including surface preparation to the complete satisfaction of the Consultant. The contractor shall submit the dynamic pile load test methodology / procedure to the consultant for his approval. For 600mm dia Piles
Providing Pre-construction Anti-termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentration under grade slab and grade beam and below the ground level as well as outside alround the building at plinth level etc as per the instructions of manufacturer and as directed by the Engineer-in-charge. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 or equivalent BS specification. The chemical to be used as insecticide for the treatment and the application shall be diluted 1 part of chemical with 49 parts of water to get 0.05% emulsion and strictly in accordance with the manufacturer’s specification. The work should be carried out by an approved and registered specialist pest control agency only. A 10 years post application guarantee against defects shall be furnished by the main Contractor. Note : Horizontal plan area at ground floor level of the building will be measured and paid. The chemical to be used for the treatment and concentration of the chemical solutions should be as laid down in IS - 6313 Part II as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All works upto plinth level. 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size derived from natural sources) As per standards, specifications and directed by the Engineer-in-Charge.
Providing and laying in position ready mixed or site batched design mix cement M30 concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level with minimum cement content 410 Kg per Cum
Providing and laying in position ready mixed or site batched design mix cement concrete M40 concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level with minimum cement content 440 Kg per Cum
Providing and laying in position ready mixed or site batched design mix cement M25 concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto all levels with minimum cement content 400 Kg per Cum
Providing and laying in position ready mixed or site batched design mix cement M30 concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;All works above plinth level upto all levels with minimum cement content 410 Kg per Cum
Providing and laying in position ready mixed or site batched design mix cement M40 concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto all levels with minimum cement content 440 Kg per Cum
Providing and laying in position ready mixed or site batched design mix cement concrete M15 for cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete All works above plinth level upto all levels with minimum cement content 320 Kg per Cum
Providing and laying steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding with 16 gauge binding wires. all complete including cost, conveyance, lead, lift of all materials of all types of RCC Works as per drawing/ specifications, upto highest plinth level with Thermo-Mechanically Treated bars of grade Fe-500D or more.As per standards, specification and directed by the Engineer-in-charge.
Providing and laying steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding with 16 gauge binding wires. all complete including cost, conveyance, lead, lift of all materials of all types of RCC Works as per drawing/ specifications, above highest plinth level upto all levels with Thermo-Mechanically Treated bars of grade Fe-500D or more.As per standards, specification and directed by the Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. upto highest plinth level. As per standards, specification and directed by the Engineer-in-charge
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts upto highest plinth level. As per standards, specification and directed by the Engineer-in-charge. Regular Column
Centering and shuttering including strutting, propping etc. and removal of form for Shuttering in Circular Column upto highest plinth level. As per standards, specification and directed by the Engineer-in-charge. Circular Column
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers upto highest plinth level . As per standards, specification and directed by the Engineer-in-charge. Beam (upto Ground Floor), Pile Cap Tie Beam
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc upto highest plinth level. As per standards, specification and directed by the Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform upto highest plinth level. As per standards, specification and directed by the Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) upto highest plinth level. As per standards, specification and directed by the Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts above highest plinth level at all levels. As per standards, specification and directed by the Engineer-in-charge. Regular Column
Centering and shuttering including strutting, propping etc. and removal of form for Shuttering in circular Column above highest plinth level at all levels. As per standards, specification and directed by the Engineer-in-charge. Circular Column
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers above highest plinth level at all levels. As per standards, specification and directed by the Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform above highest plinth level at all levels .As per standards, specification and directed by the Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) above highest plinth level at all levels . As per standards, specification and directed by the Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc above highest plinth level at all levels . As per standards, specification and directed by the Engineer-in-charge.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete at all heights. Painting steel work with two or more coats of Synthetic enamel paint of Ist quality and approved colour to give an even shade over two coats of zinc chromate primer (70 micron) including, filling the joint welding with metal paste and cleaning the surfaces, Working platform/scaffolding & the DFT test of primer & paint etc; complete all as per specifications (Rate to include cost of zinc chromate primer also). Complete at all levels and locations.As per standards, specification and directed by the Engineer-in-charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and Painting steel work with two or more coats of Synthetic enamel paint of Ist quality and approved colour to give an even shade over two coats of zinc chromate primer (70 micron) including, filling the joint welding with metal paste and cleaning the surfaces, Working platfrom/scaffolding & the DFT test of primer & paint etc; complete all as per specifications (Rate to include cost of zinc chromate primer also). Complete at all levels and locations.As per standards, specification and directed by the Engineer-in-charge.
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately) including all lift, lead, scaffolding at levels and As per standards, specification and directed by the Engineer-in-charge
Supply & Installation of Modular side fixed glass balustrade system of 15.52mm thk clear toughened laminated glass supported with through-hole fixation, 4 nos Ø50mm X 30mm cylindrical glass adaptors (MOD 0749) of AISI 304 per Glass panel with all fixing points at max. c/c 1200 mm etc complete with necessary rubber bidding, Ø 42.4x 2mm thk SS304 Handrail pipe along with stemkey,turns & bend. Railing height at the Staircase will be 1000mm. The Rate Inclusive of Material Supply - cost for MOD 0749 profile including EPDM rubber,Caprail, End caps Glass Supply - 15.52mm thk Clear Toughened Laminated Glass(8mm + 1.52PVB + 6mm toughened laminated glass) including installation with all fittings and Scaffolding etc.including lead, lift ,labour etc, complete at all levels as per the engineer in charge. Note: Shop drawing to submitt for approval .As per standards, specification and directed by the Engineer-in-charge
Providing and fixing window security grills of approved dia bars, welded vertically & horizontally with equal centre to centre or of approved pattern and design, consisting of MS angles/flats and bars securely fixed with angle cleats and embedded to the wall, slabs as per site condition and as directed at site including painting the grill with two coats of synthetic enamel paint over a coat of primer all complete including all lead, lift , labour etc at levels .As per standards, specification and directed by the Engineer-in-charge
Providing and fixing MS hand railing made of hollow section, flats etc., including welding, grinding and making curvature (wherever required) of required size, and painting with approved shade of 2 coats of synthetic enamel paint over its base primer coat and fixed on the top of the floor or the side of waist slab with suitable arrangement including all lead, lift , labour etc at levels as per approval of Engineer-incharge
Providing and fixing Stainless steel (Grade 304) railing made of hollow tubes, channels, paltes etc., including welding, grinding, buffing,polishing and making curvature (whever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fastners, stainless steel bolts etc. , of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge Note: Shop drawing to submitt for approval .
Floor-to-Floor Joint Systems: Supply and Installation of expansion joint covers which is designed to accomodate LMV loads and the system will provided thermal and seismic movement.All floor to floor flat model,upto 50 mm Expansion Joints Aluminum Covers Profiles having a hard wearing,maintainence free long lasting design having smooth surface. . The surface of the Exp. Joint Covers should have Serrated Surface for Skid Resistance and should be ADA Compliant. The design of the Expansion Joint Cover System should be such that it should avoid any accumulation of dirt. The Expansion Joint Cover should have an Articulated Telescope Design so as to accommodate the movements in 3 directions. The total Horizontal Movement should 22.5 mm (-7.5 / +15 mm). It should also accommodate a Vertical Movement of 10 mm. The system should be in 6063 alloy in Mill finish and the total exposed surface of the profile should not be more than 73 mm (+/-5 mm) & the installation Height can be of 50 mm. The system can be used for standard Rolling loads of private Cars or Cart wheel loads. The side profile should have a MULTI HOLE mounting bracket allowing for secure fixing and Flexible anchoring and excellent bonding with given slab surface/masonry/epoxy bedding. .All material and labour including all lead, lift at levels complete in all respects and as per standards, specification and directed by the Engineer-in-charge , The agency should provide 10 years supply and Installation warranty.
Wall to Wall/corner ceiling to ceiling/corner (Interior & Exterior )Joint Systems: Supply and Installation of surface-mounted metal wall and ceiling cover is designed for interior applications where low maintenance or tamper-resistant applications are desired. The joints shall be of extruded aluminium base members ,self aligning /centring arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an expansion joints system suitable for vertical wall to wall/ wall to corner application, with no slipping down tendency amongst the components of the joint system . The Joint system shall utlize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. ( Material shall conform to ASTM 6063) The rate shall include all material and labour including all lead, lift at levels complete in all respects and as per standards, specification and directed by the Engineer-in-charge. The agency should provide 10 years supply and Installation warranty.
Providing and applying water/moisture barier (for external expansion joint treatment) after proper surface preparation to remove loose mortars, dust, foreign particles from joints, fixing of tightly packed closed cell polyethylene based back up rod or filler board to ensure no gaps or voids exists, mask face edge of the joint using masking tape for neat finish, mixing of Chemical adhesive of tape– Two part Epoxy Adhesive using slow speed drill till get homogeneous mix, apply it to prepared joint 1-2mm thick with notched trowel or putty blade, tooled to a smooth finish and finally fixing of Seal Tape– Flexible expansion joint membrane available in 1mm thickness EPDM and 150 mm wide exhibiting superior mechanical properties like, Elongation >500%, Tensile Strength >12N/mm2, Tear Strength >200N above joint followed by another layer of epoxy adhesives as complete as per manufacturer’s specification. For joint over end laps, the overlaps surfaces must be clean, wiped and lapped with 100 mm overlap. After application the system should be allowed to cure for 7 days. As per standards, specification and directed by the Engineer-in-charge. (This shall be carried out by speciliazed agency having sufficient experince in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
Providing, placing and fixing in position PVC board of 100 kg/cum density at all expansion joints and separation joints and wherever specified to the required sizes, shapes, etc., complete. 25mm thick As per standards, specification and directed by the Engineer-in-charge
WATERPROOFING WORK PILE CAP ENCAPSULATION Providing and carry out pile cap treatment after carry out proper surface preparation to remove loose concrete, standing water, dust etc. The concrete surface must be free of standing water, debris and mud etc. Carry out pile cap reprofiling using Micro Concrete and allow the same to water cure for approx. 3 days followed by fixing of Double Side adhesive tape of 100mm width in such a way to cover 80mm on PCC and 20mm on pile vertical surface, application of epoxy grout in approx. 10 mm thickness over pile cap followed by application of Single Sided adhesive tape on vertical side of the piles overlapping double sided tape before laying HDPE Membrane etc. complete. The rate shall include all materials and labour all lift lead at levels and as per standards ,specifications and directed by the Engineer-in Charge. For 500 mm dia (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
WATERPROOFING WORK PILE CAP ENCAPSULATION Providing and carry out pile cap treatment after carry out proper surface preparation to remove loose concrete, standing water, dust etc. The concrete surface must be free of standing water, debris and mud etc. Carry out pile cap reprofiling using Micro Concrete and allow the same to water cure for approx. 3 days followed by fixing of Double Side adhesive tape of 100mm width in such a way to cover 80mm on PCC and 20mm on pile vertical surface, application of epoxy grout in approx. 10 mm thickness over pile cap followed by application of Single Sided adhesive tape on vertical side of the piles overlapping double sided tape before laying HDPE Membrane etc. complete.The rate shall include all materials and labour all lift lead at levels and as per standards ,specifications and directed by the Engineer-in Charge. For 600 mm dia (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
BASEMENT & TANK BASE WATERPROOFING. Supplying and installing 1.5mm composite thick fully bonded pre-applied weldable grade HDPE membrane having tensile strength of bare HDPE film greater than 25 MPa (As per ASTM D412), elongation of bare HDPE film greater than 400% (As per ASTM D412), puncture resistance greater than 1000N (As per ASTM E154), resistance to hydrostatic pressure head greater than 70m (As per ASTM D 5385), low temperature flexibility at -25 degree C (As per ASTM D1970), peel adhesion to concrete more than 880N/m (As per ASTM D 903), lap peel adhesion greater than 15000 N/m (As per ASTM D1876), water vapour transmission of 0.03 perms (As per ASTM E96) and water absorption less than 0.5% (As per ASTM D570). The HDPE membrane shall be tested as per EN 13251:2016 and shall be passed for durability test of 25 years and also conforming to requirements of IS 16471:2017 Type A protection of UG waterproofing structures. The HDPE membrane should be of minimum 2.4mx20m roll size, to reduce the number of joints, with minimum 75mm wide factory made selvedge along the side laps and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer. The membrane shall be taken up to minimum 100mm on the vertical within the shuttering of the footings, Grade slab , Raft slab or in case of any confined wall areas up to the full height of the confined portion of the retaining wall . The membrane shall be of a special HDPE grade with overlaps that should be hot air fusion welded on site to ensure fool proof joints.The rate shall include all materials and labour all lift lead at levels and as per standards ,specifications and directed by the Engineer-in Charge. (This shall be carried out by speciliazed agency having sufficient experince in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
LIFT PIT & TANK WALL EXTERNAL WATERPROOFING Providing and laying 1.5 mm thick SBS modified self adhesive waterproofing membrane topped with HDPE film having tensile strength of minimum 3.5 MPa (As per ASTM D412-06), minimum elongation of 180% (as per ASTM D412-06), Puncture resistance of >200 N (as per ASTM E154) and resistance to hydrostatic pressure head greater than 60m (As per DIN 1048). The system includes base preparation of cleaning, brushing and removal of flacky materials, construction joint treatment, proper coving between slab and wall junctions and priming the surface with cold applied bituminous primer, followed by application of SBS membrane. The SBS membrane should be sealed properly at joints & maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the surface etc as per manufacturers specification and methodology. Termination: The SBS membrane should be terminated at top using aluminium strip flashing with fasteners and the joint should be sealed with PU Sealant/ Polysulphide sealant. The rate shall include all materials and labour all lift lead at levels and as per standards ,specifications and directed by the Engineer-in Charge. (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
Protection to the waterproofing system against backfilling: Providing & Fixing of 8mm thick dimple board of compressive strength not less than 200kN/m2. Dimple board to be fixed using suitable adhesive by spot bonding method and complete As per standards, specification and directed by the Engineer-in-charge. The rate shall include all materials and labour all lift lead at levels including scaffoldings (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
RETAINING WALL WATERPROOFING Supplying and applying two component, instant setting, 100% solids spray applied hybrid polyurea polyurethane liquid applied elastomeric seamless waterproofing membrane meeting the requirements of LAM as per ASTM C836 and having excellent tensile strength of 15MPa (As per ASTM D412), elongation more than 450% (as per ASTM D 412), tear strength of 60 Kn/m (As per ASTM D1004/ASTM D624), adhesion to concrete of 2MPa (as per ASTM D 4541), abrasion resistance of 60mg loss (1 Kg,CS 10 Wheels,1000 cycles - As per ASTM D4060), Shore A Hardness of 85 (As per ASTM D2240), resistance to hydrostatic pressure head of 7 Bar (As per ASTM D 5385/ DIN 16726), puncture resistance of 1000N (As per ASTM E154), water vapour permeability of 25 mg/m2/day (As per ASTM E96), Impact resistance of 17 N.m (As per ASTM D2794), Low temperature crack bridging ability up to 3.2mm (As per ASTM C 1305), dynamic crack bridging ability class B 3.2 (as per EN 1062-7 Method B- B3.2) with no crack observed in the coating after 20000 sinusoidal cycles, resistance to root (As per CEN TS/14416) and fire resistance of class B (As per EN 13501-1). The coating shall be applied with a total consumption of 1.6 Kg/Sqm to achieve a total system DFT of 1.5 mm, thereby satisfy the requirements of LAM as per ASTM C898 and shall be applied on the entire vertical surface of the retaining wall. The system includes base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, proper coving between slab and wall junctions and priming the surface with two component solvent free epoxy primer which is applied with a consumption of 200 grams per Sqm, followed by spray application of hybrid polyurea waterproofing coating. The rate shall include all materials and labour all lift lead at levels and as per standards ,specifications and directed by the Engineer-in Charge. (This shall be carried out by speciliazed agency having sufficient experince in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
TANK INTERNAL WATERPROOFING Providing and applying 2 coats of Non Sag PU Coating after mixing the two components. It shall be applied in two coats by roller only @ 1.4 kg/sq.m. (0.5 kg/sq.m. in 1st coat and remaining in 2nd coat). Gap between the two coats application shall not exceed 12 hours. The coating shall have solids content of 100%, Elongation of 100% & Tensile Strength >10Mpa as per ASTM D412, Hardness >40 as per ASTM D 2240, Hydrostatic Pressure resistance of 5bar as per EN12390, Adhesion to concrete >1.5Mpa as per ASTM D7234 and Water Absorption <0.5 % as per ASTM D570, Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA for potable water contact all as per manufacturers' specification, etc, complete. The system includes base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, sealing the minor cracks, proper coving between slab and wall junctions and priming the surface with water based primer at 100 grams/Sqm, followed by the application of waterproof coating.The rate shall include saw cuting (approx 6mm W x 10 mm D) at 3MX4M panels and filling the groove with PU sealant, and making angle fillet of 100mmX100mm using M20 grade concrete at the corners after screed concrete (Screed shall be paid separately) including all materials , labour , lead lift at all levels and As per standards, specification and directed by the Engineer-in-charge. (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
Vertical protection : Supplying and applying 15mm thick polymeric waterproof plastering with CM 1:4 admixed with integral waterproofing compound at 0.2litre/bag of cement.As per standards, specification and directed by the Engineer-in-charge (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
LIFT PIT INTERNAL WATERPROOFING Providing and applying two coats of crystalline waterproofing coating, with bulk density 1.35 -1.55 g/cc, water permeability NIL (As per BS EN 12390 Part 8:2000), Resistance to water pressure head up to 40 meters, applied in two coats at 0.75kg/coat as per manufacturer’s specifications. The 1st coat shall be applied to the prepared surface. Whilst the 1st coat is still “green” the second coat shall be applied. The slurry coatings shall be applied with a stiff masonry brush or stiff broom and worked into every irregularity on the surface including curing etc. The system includes base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, sealing the minor cracks, proper coving between slab and wall junctions and pre-wetting the surface to attain SSD condition before application of the waterproofing coating, followed by the application of 2 coats of crystalline waterproofing coating. The rate shall include all materials and labour all lift lead at levels and as per standards ,specifications and directed by the Engineer-in Charge.. (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
TOILETS WATERPROOFING Providing and applying two component high performance polymer modified cementitious waterproofing coating, having minimum elongation of 120%, Tensile strength 1 N/mm2 (As per ASTM D412), Water Vapour Transmission 0.7 Perms (As per ASTM E96), Adhesion Strength 1 Mpa (As per ASTM D 7234), Crack bridging up to 2mm (As per ASTM C836) and food grade certification by CFTRI, including reinforcing the coating with 45gsm glass fibre mesh at all corners. The coating shall be applied with a total consumption of 2 Kg/Sqm in two coats on the entire horizontal and vertical surface as per manufacturer's specification and methodology. The system includes base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, sealing the minor cracks, proper coving between slab and wall junctions and pre-wetting the surface to attain SSD condition before application of the waterproofing coating, followed by the application of waterproof coating.As per standards, specification and directed by the Engineer-in-charge (This shall be carried out by speciliazed agency having sufficient experince in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
STP INTERNAL WATERPROOFING Providing and applying two component high performance polymer modified cementitious waterproofing coating, having minimum elongation of 120%, Tensile strength 1 N/mm2 (As per ASTM D412), Water Vapour Transmission 0.7 Perms (As per ASTM E96), Adhesion Strength 1 Mpa (As per ASTM D 7234), Crack bridging up to 2mm (As per ASTM C836) and food grade certification by CFTRI, including reinforcing the coating with 45gsm glass fibre mesh at all corners. The coating shall be applied with a total consumption of 2 Kg/Sqm in two coats on the entire horizontal and vertical surface as per manufacturer's specification and methodology. The system includes base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, sealing the minor cracks, proper coving between slab and wall junctions and pre-wetting the surface to attain SSD condition before application of the waterproofing coating, followed by the application of waterproof coating. The rate shall include saw cuting (approx 6mm W x 10 mm D) at 3MX4M panels and filling the groove with PU sealant, and making angle fillet of 100mmX100mm using M20 grade concrete at the corners. After screed concrete (Screed shall be paid separtely).As per standards, specification and directed by the Engineer-in-charge. (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
Final chemical resistant epoxy finish for STP: Supplying and applying two coats of high chemical resistant and abrasion resistant coal tar epoxy resin coating, having adhesion to concrete up to 1.4 Mpa (As per ASTM D4541) applied at 500 grams/Sqm in 2 coats (250 grams/Sqm/coat)..As per standards, specification and directed by the Engineer-in-charge. (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
ROOF & PODIUM WATERPROOFING Providing and applying 2 component liquid applied, high build elastomeric polyurethane waterproofing system which complies to ASTM C 836 for the minimum thickness of 1.5 mm DFT. This shall be applied at a coverage @ 2.0-2.1 kg/m2 to achieve minimum DFT of 1.5 mm using metal scrapper. The coating shall be applied on the entire horizontal surface and 300mm above FFL on vertical surface. The product shall be exhibiting properties i.e. Solids by Volume : 98%, Tensile strength (ASTM D412) : >6 N/mm2, Elongation (ASTM D412) : >600%, Tear Resistance (ASTM D624) : 35 N/mm, Shore A Hardness (ASTM D2240): 70, Bond Strength to concrete (ASTM D 7234) - >1.5 Mpa, Crack Bridging ability(Static) (EN 1062-7)- > 3.5 mm, Puncture Resistance (ASTM E154) - > 300 N, Resistance to hydrostatic head (ASTM D5385) - > 70 Mtr, Root Resistance (CEN TS/14416) : Pass & Dynamic Crack Bridging (EN 1062-7, Method B-B 3.2) 20000 cycles at (-20 °C): Pass. The system includes base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, proper coving between grade slab and retaining wall junctions and priming the surface with moisture insensitive epoxy primer applied with a total consumption of 200 gms/Sqm, followed by application of polyurethane coating in two coats. The rate shall include Supplying and applying protective geo textile fabric of 120 GSM over the entire membrane with proper overlaps and including saw cuting (approx 6mm W x 10 mm D) at 3MX4M panels and filling the groove with PU sealant, and making angle fillet of 100mmX100mm using M20 grade concrete at the corners. The screed concerte shall be measured separetely. As per standards, specification and directed by the Engineer-in-charge. (This shall be carried out by speciliazed agency having sufficient experince in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
Supply & Fixing of 8 to 10mm thick thermally bonded polypropylene geotextile laminated dimpled drain board CE certified having compressive strength not less than 400kN/m2 (as per ISO 25619-2) , drainage capacity of 3.5 l/(ms) (as per ISO 12958) and puncture resistance of 1250N (as per ISO 12236).As per standards, specification and directed by the Engineer-in-charge. (This shall be carried out by speciliazed agency having sufficient experince in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
MASONARY WORKS - Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/ 125 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor at all levels in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry . The rate shall include all materials and labour all lift lead at levels and as per standards ,specifications and directed by the Engineer-in Charge.
MASONARY WORKS - Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/200mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level upto all levels with RCC band at every 1.2m with approved block laying polymer modified adhesive mortar all complete The rate shall include all materials and labour all lift lead at levels and as per standards ,specifications and directed by the Engineer-in Charge.(The payment of RCC band and reinforcement shall be made for separately).
Providing and construction of Solid block masonry in cement mortar 1:6 (1 cement:6 Msand)using concrete block of M10 grade up to plinth level as per specifications and as directed by the engineer in charge.
Providing and construction of Solid block masonry in cement mortar 1:6 (1 cement:6 Msand)using concrete block of M10 grade above highest plinth upto all levels as per specifications and as directed by the engineer in charge. The rate shall include all lead,lifts , scaffolding
Providing and laying cement 12mm thick plaster on surfaces with fine sand including curing etc for internal walls including toilet area.Including cost and conveyence of materials, labour, scaffolding charges etc at all levels. And as per standards, specification and directed by the Engineer-in-charge. 1:6 (1 cement : 6 fine sand)
Providing 6mm thick cement plaster on surfaces with fine sand including curing etc for ceiling. Including cost and conveyence of materials, labour, scaffolding charges etc at all levels. And as per standards, specification and directed by the Engineer-in-charge. 1:3 (1 cement: 3 fine sand)
Providing 12 mm cement plaster finished with a floating coat of neat cement of mix for Wall /RCC surfaces.Including cost and conveyence of materials, labour, scaffolding charges etc at all levels. And as per standards, specification and directed by the Engineer-in-charge.. 1:4 (1 cement : 4 fine sand)
Plastering Work - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. Including cost and conveyence of materials, labour, scaffolding charges etc. at all levels. And as per standards, specification and directed by the Engineer-in-charge.
Providing and fixing one layer of GI chicken mesh of 24 guage including fixing with nails extra at the junction of brick masonry and rcc or at any other place including cost and conveyence of materials, labour, scaffolding charges etc at all levels As per standards, specification and directed by the Engineer-in-charge.
Providing and mixing extra for water proofing material in cement plaster work in proportion recommended by the manufacturers.Including cost and conveyence of materials, labour, scaffolding charges etc at all levels. And as per standards, specification and directed by the Engineer-in-charge.
JOINERY WORKS Supplying , providing and fixing in position first Solid wood frames of size 100x60mm, 42mm thick Marine grade Flush Double shutters phenol bonded with both side cladded with 1mm thick laminate of approved shade, all as per design shown on the drawing including cost of beading , teak wood lipping and if any,complete. The rate should be inclusive of PU polish for frame and laminate for shutter to approved shade & complete.Door Hardware & Iron mongery shall be under the scope of contractor for smooth installation, All to be approved hardware by the architect/client. The job shall be completed in all aspects as shown in the architecture drawing and as specified by the Engineer including all other necessary related works as specified and as directed. Refer drawing AR/TD/102,AR/TD/103,AR/TD/104,AR/TD/105 The rate inclusive of providing a) 8nos - of Ball bearing butt hinges 100X75X3mm, SS304 - Rs 350/Each b) 2 No - Concealed Door Closer slide Arm channel - 01 no's - Rs. 6800/ Each c) 2 No - Door Stopper - Rs.300 / Each d) 2 No - Flush tower bolt - Rs.100 / Each e) 1 No - Door lock with handle - Rs.1100 / Each. D1 - 1500 mm x 2400 mm . The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying , providing and fixing in position first Solid wood frames of size 100x60mm, 42mm thick Marine grade Flush single shutters phenol bonded with both side cladded with 1mm thick laminate of approved shade, all as per design shown on the drawing including cost of beading , teak wood lipping etc,complete. The rate should be inclusive of PU polish for frame and laminate for shutter to approved shade & complete.The rate shall include Door Hardware & Iron mongery, All to be approved hardware by the architect/client. The job shall be completed in all aspects as shown in the architecture drawing and as specified by the Engineer in charge, including all other necessary related works as specified and as directed. The rate inclusive of providing a) 4nos - of Ball bearing butt hinges 100X75X3mm, SS304 - Rs 350/Each b) 1 No - Concealed Door Closer slide Arm channel - 01 no's - Rs. 6800/ Each c) 1 No - Door Stopper - Rs.300 / Each d) 1 No - Flush tower bolt - Rs.100 / Each e) 1 No - Door lock with handle - Rs.1100 / Each. Door Size - D2 (1200mm x 2400mm) D3 (1000mm x 2100mm),D4 (900mm x 2100mm) The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supply and fixing of Double leaf glass door with patch fittings: Providing, fabricating and installing at site Double leaf door consisting of 10 mm thick clear laminated toughened glass(Heat soaked) of approved brand (with Glass mounting option) including stainless steel patch fittings: Bottom patch SS size 161 x 51 mm with SS Floor Spring Fixed Spindle With SS Cover Plate,90° Hold-Open of standard spring strength , top patch SS size 161 x 51 mm, lock patch with key cylinder size 148 x 43 mm radius of 10 mm, H/D- Type door handle back to back mounted of grade SS- 202 size 300 x 25 mm with dome shaped floor mounted door stopper of required number, clamp fixing (if required) and complete as per the approved architectural drawings and as per standards, specification and directed by the Engineer-in-charge. Refer drawing AR/TD/102,AR/TD/103,AR/TD/104,AR/TD/105 Note 1. Patch fittings shall be fixed to floor/ wall/ Wooden framework/Ceiling. Rate shall be inclusive of Scaffoldings. Note 2. Consumption of Silicone sealant shall not be less than 75 ml/ Running mt of groove. Note 3. Mode of measurement: The length and width of the finished work shall be measured to its nearest centimetre and area calculated in sqm upto two decimal. Note 4. Size of door may vary marginally as per the site condition. Size : 2000mm x 2400mm. Purchase Rate of Patch fittings - Rs 1000. Purchase Rate of Patch Lock - Rs.1600. Purchase Rate of H Type Btb Entrance Handles 450Mm - Rs 2600. The purchase price ( excluding GST ) is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Providing and fixing of Single Medium Duty hollow metal fire rated doors as per IS 3614: 2021, for 120min integrity only. Pressed galvanized steel confirming to IS 277 with the following specification.Recommended fire door shall be tested as per IS 17518 (Part 1) from Exova/TBW/CBRI approved lab.Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory.As per standards, specification and directed by the Engineer-in-charge. Door frame shall be single rebate grooved profile of size 125 x 55mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Door leaf shall be 46mm thick fully flush double skin door, sandwiched panel un-insulated with or without vision panel. Door leaf shall be manufactured from 1.2mm (18 guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision panel wherever applicable should be provided for 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Rate shall include supply and installation of frame,shutter as a complete assembly, including all hardwares as per Manufacture recommendation, smoke seals & glass with tapes, vision panels including all lead and lift.At all levels. etc complete to the requirement of EIC FD : 1200mm x2400mm , MS1 1500x2400mm,MS - 1200mmX2400mm
Providing and fixing of Single Standard duty Hollow metal doors confirming to IS 16074 & IS 4351 made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly. Door frame shall be single rebate grooved profile of size 125 x 55mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted & butted joints are not acceptable. Frames to have inbuild grooved sealing system for taking appropriate PVC seal. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. once frames installed it should be grouted with non fire rated PUF. Door leaf shall be 46mm thick fully flush double skin door, with or without vision panel. Door leaf shall be manufactured from minimum 0.8mm (22gauge) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided a clipon arrangement. Glass shall be minimum 6mm clear float glass with suitable gaskets as per manufacturers recommendation with a clipon arrangement. All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame,shutter as a complete assembly, including all hardware as per Manufacture recommendation, smoke seals & glass with tapes including all lead and lift etc and at all levels. etc complete as per standard and specifications directed by the EIC DD 900x1500mm, DD-1 600x1500mm,
Automatic Sliding Door : Supply, fixing, installation & commissiong of Automatic sliding glass door: Supplying, fixing and installation of Automatic Sliding Glass Door horizontal sliding type. Opening speed of door 45cm/sec/leaf and closing speed is 12-45cm/sec/leaf (adjustable). The door components are Aluminum profiled frame with Glazed panel, Stainless steel rail with Automation system, Hardwares and accessories. size of the door opening. Panel Profile: Precisely designed light weight Aluminum extruded frame sections with provision to fix glass panels. Door Panel: High clarity 10 mm thk clear laminated toughened glass encased in aluminum frame. Top Rail : Durable and anti corrosive Stainless Steel rail highly resistant to damage. Hanger Block: Specially designed Hanger block is equipped with a self cleaning plastic brush and 2 nos rollers of 38 mm Dia. Hanger block with special features of double bearing mechanism, Adjustable bearing mechanism and Automatic balance mechanism. Pulley Unit : Designed to adjust the door movement. Hood Cover: Aluminum Hood cover. Automation System: Electric Drive: High performance Permanent Magnet brushless Automation system encased in aluminum case with stainless steel rail. Driving Timer belt : S8M-10mm width. Motor rating power : 45 Watt and starting power : 180 Watt, Temperature range -20 °C to + 60 ° C. Control: Self monitoring device controlled by micro processor having advance servo control technology. Safety sensing mechanism to stop door closing if object caught in doors. Control integerated with advance features. Effectively designed Auto Reverse System should comprises of Full Range reverse and High Sensitive reverse. Advanced Digital MCU servo control assures slow movement when door closes to gap of 5 cm. In case of power failure, door can be operated manually. Operating Accessory : Push Button, Microwave rader on other side, Key switch, Function switch-open-auto-exit-close, Battery pack UPS, Electronic motor lock. Facility to synchronise access control card, Remote control with receiver. Safety Accessories : Safety photocell, flashing light, Flashing light with alarm.As per standards, specification and directed by the Engineer-in-charge. Refer drawing AR/TD/102,AR/TD/103,AR/TD/104,AR/TD/105
Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required),EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.9.147E.1 Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above2.50 sqm upto 4.00 sqm.) Refer drawing AR/TD/102,AR/TD/103,AR/TD/104,AR/TD/105
FLOORING WORKS Protecting Screed with Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate, all complete at all levels and as per standards, specification and directed by the Engineer-in-charge. Thickness : 40MM
Providing and Laying Engineered wooden flooring of approved make and pattern and as per architectural drawing and instructions of thickness 15-18 mm or as per manufactures details , consisting of 3 layers the top precious wood, the core layer is arranged below it in a cross grain direction which increases stability, the ply construction features a balancing veneer at the bottom which ensures superior dimensional stability. This make is excellently suited for installation as floating floor. The quality of hardwood floor stands and falls with the surface finish. The practical solution for the flooring is UV high finishes. Before laying the flooring, it shall be ensured that the base floor is clean, level and thoroughly dry. The flooring shall be installed by first laying of polythene sheet 0.5 mm thick on the base floor, on the top of which will be laid a 2 mm thick polyethylene cell foam jointed with tapes. The rate is inclusive of all operation, floor protection sheet, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price : Rs.400/Sft is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/116, AR/TD/116A
Providing and finishing of homogenous self levelling compound of thickness of not less than 3mm of Approved make as specified by manufacture of approved make - Under lay System Etc., As per standards, specification and directed by the Engineer-in-charge.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18-20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Purchase Price ; Rs.220/Sqft.The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location : All floor corridor Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18-20 mm thick gang saw cut granite, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: RS.220/Sqft. The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/116, AR/TD/116A
Providing and laying flamed finish Granite flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18-20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete As per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs. 280/Sqft. The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Lobby Staircases, Service area staircase, lift lobby Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18-20mm thick gang saw cut granite, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs. 280/Sqft, The purchase price ( excluding GST ) of granite slab is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Main Entry steps, seater side walls Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18-20 mm thick gang saw cut granite, machine cut of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs.150/Sqft,The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Outdoor corridor Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18-20 mm thick gang saw cut granite, machine cut of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs.200/Sqft,The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Entrance steps,planter wall cladding, ramp area Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18-20 mm thick gang saw cut granite, machine cut of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs.180/Sqft. The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Central paving,Amphi theatre paving Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18-20 mm thick gang saw cut granite, machine cut of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs.210/Sqft. The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location:Amphi theatre Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18-20 mm thick gang saw cut granite, machine cut of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: RS.145/Sqft. The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location:Plaza walkways,Feature wall cladding Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18-20 mm thick gang saw cut flamed finish granite, machine cut of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs.210/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Cascade water wall & steps, water feature wall Refer drawing AR/TD/116, AR/TD/116A
Providing and laying Full body vitrified floor tiles of 1st quality with water absorption less than 0.08% and conforming to IS: 15622, of approved make,shades and pattern , laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments, with 3mm Spacer joint including the cost and conveyance of all materials, labour charges , lead , lift , curing etc., complete and tile protection till handover as directed by Engineer in charge at all levels . The rate includes cutting the sharp edges of tiles with specialised machinery where ever required. Base Price: RS.120/Sqft,The purchase price ( excluding GST ) of vitrified tiles is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Restaurant area and Office space Refer drawing AR/TD/116, AR/TD/116A
Providing and laying vitrified floor tiles in different sizes & thickness of the tiles should be 9/10mm with water absorption less than 0.08% and conforming to IS 15622, of approved make, in all colours and shades, in skirting, riser of steps, laid over cement based high polymer modified quickset adhesive conforming to IS:15477, in thickness (as per manufactures' specification) having spacers 2mm with spacer filling with resin based epoxy grout with high degree of resistance to chemical attack,abrasion and resistance confirming to British Standards 5980:1980 and matching pigment etc. complete.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Tiles of Size 600 X 1200mm Purchase Price of Tiles : Rs.120/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/116, AR/TD/116A
Providing and laying vitrified floor tiles of 1st quality should be 9-10mm thick with water absorption less than 0.08% and conforming to IS: 15622, of approved make,shades and pattern , laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments, with 3mm Spacer joint including the cost and conveyance of all materials, labour charges , lead , lift , curing etc., complete and tile protection till handover as directed by Engineer in charge at all levels . The rate includes cutting the sharp edges of tiles with specialised machinery where ever required . The purchase price ( excluding GST ) of Vitrified tile shall be as metioned below in Purchase Rate and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. The work shall be carried out by an agency having good experience with the skilled labours on the specified work mentioned above.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Basic Price of Tiles : Rs.60/Sqft, The purchase price ( excluding GST ) of vitrified tile is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Shop area floors, store rooms etc. Refer drawing AR/TD/116, AR/TD/116A
Providing and laying vitrified floor tiles in different sizes & thickness of the tiles should be 9-10mm with water absorption less than 0.08% and conforming to IS 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including grouting the joints with white cement, with 2mm Spacer jointand matching pigment etc. complete.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price of Tiles : Rs.60/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/116, AR/TD/116A
Providing and laying Vitrified Matt/Anti Skid finish Tiles in floor in different sizes & thicknessof the tiles should be 9-10mm thickness with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement, with 2mm Spacer joint and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Size of tiles shall be 600mmx600mm Purchase Price of Tiles: Rs. 200/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Toilets floors Refer drawing AR/TD/116, AR/TD/116A
Providing and laying Glazed Vitrified Tiles in Walls in different sizes & thicknessof the tiles should be 9-10mm thickness with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement, with 2mm Spacer joint and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Size of tiles shall be 1200mmx600mm Purchase Price of Tiles: Rs.200/Sqft.The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Toilet walls Refer drawing AR/TD/116, AR/TD/116A
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 400 kg/cum)
Providing edge moulding to 18 -20mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Refer drawing AR/TD/116, AR/TD/116A
Providing and laying, Exterior grade IPE wooden deck flooring in 20mm thick sized planks, air dried to moisture content not exceeding 12%, tested for strength as per ASTM-D143 & for slip resistance as per ASTM C1028-89 and laid in approved pattern and in required position on base frame work made out of aluminium frame of 25mm x50mm size drilling & fixing to the floor base using screws with rawl plug or any other approved fixing arrangements.The rate is inclusive of all operation, material , base frame work of aluminium and required pattern as per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs.600/Sqft, The purchase price of IPE wooden deck flooring is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/116, AR/TD/116A
Providing and laying Wooden Planks flooring in 32mm thick sized planks laid in approved pattern and in required position on base frame work made out of aluminium frame of 25mm x50mm size drilling & fixing to the floor base using screws with rawl plug or any other approved fixing arrangements.The rate is inclusive of all operation, material ,base frame work with aluminium and required pattern as per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs.350/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Providing & Laying of 50X50mm Mosaic tiles with necessary adhesive for water body floor and wall cladding cost including cleaning & washing with diluted detergent, & remove cement mortar deposits, including curing etc., complete. Purchase Price of Tiles : Rs.280/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Providing and fixing machine cut, 18-20mm thick flamed finish Granite stone work for including dado, skirting risers and threads etc., in required design and pattern wherever required, stones of different finished surface texture, on 20 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. Purchase Price of Tiles: Rs.270/Sqft, TThe purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: All staircases Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing 18 -20 mm thick polished granite, machine cut for risers and threads of staircase of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.The rate is inclusive of all operation, material and required pattern As per standards, specification and directed by the Engineer-in-charge. Purchase Price: Rs.116/Sqft,The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Stair risers Refer drawing AR/TD/116, AR/TD/116A
Providing & Installation of Fluted Cermaic Tile with water absorption less than 0.08% and conforming to IS: 15622, of approved make,shades and pattern , laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments, with 3mm Spacer joint including the cost and conveyance of all materials, labour charges , lead , lift , curing etc., complete and tile protection till handover as directed by Engineer in charge at all levels . The rate includes cutting the sharp edges of tiles with specialised machinery where ever..The rate shall include all cut out for switches and lights ,materials, labours, scaffolding, leads and lifts etc. all complete as per approved shop drawings and as directed by the Engineer. Base Price: Rs.220/Sqft, The purchase price ( excluding GST ) of tile is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Providing and fixing machine cut, mirror/ eggshell polished , Marble stone cladding work of thickness 18-20 mm for wall lining including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.The rate shall include all lead,lifts and scaffolding for the work. Purchase Price: Rs.500/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Lift wall cladding Refer drawing AR/TD/116, AR/TD/116A
Providing and fixing machine cut, mirror/ eggshell polished , Granite stone work of thickness 18-20mm dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. Purchase Price: Rs.200/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/116, AR/TD/116A
FALSE CEILING WORKS Providing and fixing suspended false ceiling (Seamless gypsum false ceiling), at all levels which includes providing and fixing G.I Perimeter channels of size 0.50mm thick with unequal flanges of 20mm and 30mm and a web of 28mm along the perimeter of ceiling, screw fixed to brick or RCC wall /partitions with the help of nylon sleeves and screws, at 230mm centres. Then suspending G.I. Intermediate channels of size 45x15mm, 0.9mm thick from the structural roof members as per drawing at 1220mm centres (maximum) with ceiling angle of 25mmx10mmx0.5mm bolted to structural roof members with suitable arrangement for proper fastening. Ceiling section of 0.5mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the intermediate channel at 457mm centres. 12.5mm moisture resistant tapered edge Gypsum board (conforming to IS-2095- part 1: 2011)is then screw fixed to ceiling section with 25mm dry wall screws at 230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. The boards shall be jointed and finished to a flush finish of tapered and square edges of gypsum board (including providing V grooves in cut tiles wherever necessary )with recommended jointing compound filler ( 2 coat putty) with paper tapes, control joints and finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and finished on the bottom side with two coats of approved putty,two coats of approved primer suitable for gypsum board as per manufacturers specifications and two coats of plastic emulsion paint of approved brand and two coats of approved quality water sealant on the top surface of gypsum board. The ceiling shall be provided with recessed portions/coffers/cove as per drawing. Nothing extra shall be paid for providing specified number of recesses at different levels. The vertical/slanting portion between different levels shall also be provided with 12.5mm Moisture resistant gypsum board panels fixed by means of 25x10x0.5mm GI angle sections and ceiling sections as specified.The rate shall also include the cost of making openings of any shape for light fittings, grills, diffusers, cut-outs etc. made with frame of perimeter channels as per drawing and finishing the edges as directed by Engineer-in-charge.The rate shall include cost, lead, lift of all materials, labour, scaffolding charges, painting etc.complete as per drawings, specifications and direction of Engineer-in-charge. The measurement shall be in square metres and deductions shall be made for all openings exceeding 0.4 sqm in area.The exposed vertical area also will be measured and paid along with horizontal area. Refer drawing AR/TD/115
Providing and fixing suspended false ceiling using 12 mm Calcium Silicate board which includes providing and fixing GI perimeter channels of size 0.55 mm thk. having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, screw fixed to brick wall/ partition with help of nylon sleeves and screws, at 610 mm centers. The suspended GI intermediate channels of size 45 mm, 22 gauge with two flanges of 15 mm each from the soffit at 18" to 24" centres with suitable ceiling supports fixed to soffit with GI cleat and steel expansion fasteners. "Jali" shall be fixed to the cross frame with screw and washer arrangement (Confirming to IS-2095-1982). If required Plaster of paris punning done to suitable thickness to attain uniform surface Multi level ceilings with curvature / steps/ chamfer shall be done as per the reflected ceiling plan and as instructed by the architects. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. The rate shall inclusive of providing Joints filling compound with adhesive tape between the boards ,cut outs for AC , Light fittings , Speakers, Smoke and fire detectors , required scaffolding including providing & removing of the same etc., to complete the work as per Engineer - In- Charge. Note: For Light fittings, Grills, diffusers and other cut-outs have to be made with a frame of perimeter channels of size 20mm x 27mm x 30mmx 0.55mm thk, supported suitably which is included in the rate. Note: Only false ceiling area will be measured from wall to wall. And no deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm. Refer drawing AR/TD/115
Providing & Fixing of GI in Standard Perforated(2.5mm diameter-16% open area) metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in color with acoustical fleece hot pressed to the back of the perforated tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm & 600 mm Cross Tees.The tiles would have NRC of 0.70, Fire Performance of Class A2-s1.d0 as per EN13501 standard in module size of 600 X 600 mm suitable for Green Building application, with Recycled content of 25%. The grid should be with 15mm wide T - section flanges color white having rotary , stitching on all T sections i.e. the Main Runner with C3 coupling, 1200 mm & 600 mm Cross Tees with.Hardened XL2 Clip having a web height of 38 mm and a load carrying capacity of 14 Kgs/M. The T Sections have a Galvanizing of 90 grams per M2 with pull out strength of 100 Kgs.The work shall include all materials, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and as directed by the Engineer. Purchase Price of Tiles: Rs.400/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/115
CEILING Providing and fixing 20mm thick IPE wooden ceiling panelling fixed to Aluminium framework made 25x50mm Aluminium frame as per the detail in drawing.The work shall include all materials,base framework with aluminium of approved make, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and as directed by the Engineer.Purchase Price of IPE wooden ceiling : Rs.400/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/115
Supply, fixing and installation of suspended 19 mm thick marine BWP grade Ply conforming to IS -710 for ceiling wrapped with 4 mm thick MDF and 500mm depth for ceiling with nickel plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to ply . Finished with duco on both side and bottom also. The cost shall include the nickel plated brackets and painting with duco on all sides including all lift,lead and scaffoldings at all levels. All complete as per the specification and design drawing and as per standards, specification and directed by the Engineer-in-charge. Refer drawing AR/TD/115
Providing & fixing suspended Mirror false ceiling with 10mm reflective laquered glass as per the pattern specified size in the detailed architectural drawing fixed to MS frame work with necessary tools,accessories, equipments & machineries etc complete. Rate to include cutting, handling, shifting & finishing the glass including all other required hardwares as per the engineer direction at site. All complete as per the specification and design drawing and as per standards, specification and directed by the Engineer-in-charge. MS work shall be measured separately in the relevent item. Note : Shop drawings for the to be submitted before starting the production and get approval from Client / Architect ) Refer drawing AR/TD/115
Providing and fixing of Wooden Veneer ceiling formed out of 12mm thick marine ply confirming to IS -710 with necessary framework , fixed rigidly to the true ceiling / ms frame structure with necessary hardwares like SS clutch cables and anchor fasteners . The ply to be finished on all sides with approved 4mm thick veneer over 12mm thick ply as per detail drawings and as per the directions of Architect / Project Manager as required at site. Veneer Surface has to be finished with approved shade of PU finish . Veneer is finished by applying ,pu coat sealer , sanding the surface and finishing with 2 coat PU ceramic / glossy / matt coat as per the requirement by the architect . The rate shall include the base Aluminum frame work and the finishing with the approved shade of PU finish including the base treatments before PU finish. The rate shall also include all connectors, accessories, fastners, profiles, adhesive tapes, seals, making necessary opening for AC grille / Electrical/Data/Voice switches, cove lights, sockets ,materials, labours, scaffolding, leads and lifts etc. all complete as per approved shop drawings and as directed by the Engineer. The MS frame work shall be measured separately in the relevent item. Purchase Price of Veneer : Rs.200/Sqft, The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Refer drawing AR/TD/115
Supplying and erection of the tensile structure, fabrication of the 902 S2 Type 2 fabric (15 years warranty) weight above 950 g/m2 ,Fabric tensile strength - 420/400 daN/5cm, and Tear resistance of 55/50 daN, visible light transmitance 8%, Fire rating Euroclass B-s2, d0/EN 13501-1, High frequency welding to be done in for strom to ensure the quality and adhesion. design requirement with proper prestress values, Edge cables are non greese GI with SS304 end terminal, Accessories required for the installation with specified quality and grade including transport to site. Installation of the converted fabric with using scaffolding, crane with proper safety measures (HSE Norms), precautions with industry standard precaution and with appropriate tools and tackles.Supply & factory fabrication of the supporting steel structure with design norms with 310 grade steel tubular section conforming to IS standards, bending , prefabrication works including preset laser cutting secondary steel with proper anticorrosion treatment followed by one coat of the Zinc rich primer ,including transport to the site. including all bent tubes, bracing , base plate, j- bolts , secondary steel. Installation of the steel structure with using heavy duty crane, scaffoldings , with safe work procedure, followed by 2 coat of the zinc rich primer and 2 coats of the Epoxy paint with Appropriate surface finish. The rate shall include the cost of MS structure with painting with primer and epoxy paint and all lead, lifts and scaffolding including erection of the structure and complete as per standards ,specifications and as directed by the Engineer-in Charge. Refer drawing AR/TD/115 (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 15 years. only skilled and experienced persons shall be employed for this work)
Supply & fabrication of the FRONT SIDE VIEW 381 MESH FABRIC(Chinese Net) Type 2 fabric (10 years warranty) weight above 550 g/m2 ,Fabric tensile strength - 330/300 daN/5cm, and Tear resistance of 80/90 daN, visible light transmitance 8%, Fire rating Euroclass B-s2, d0/EN 13501-1. High frequency welding to be done in forstrom to ensure the quality and adhesion. design requirement with proper prestress values, Edge cables are non greese GI with SS304 end terminal, Accessories required for the installation with specified quality and grade including transport to site. Installation of the converted fabric with using scaffolding, crane with proper safety measures ( HSE Norms ), precautions with industry standard precaution and with appropriate tools and tackles.Supply & factory fabrication of the supporting steel structure with design norms with 310 grade steel tubular section conforming to IS standards, bending , prefabrication works including preset laser cutting secondary steel with proper anticorrosion treatment followed by one coat of the Zinc rich primer ,including transport to the site. Approximate steel tonnage is 9 tons , including all bent tubes, bracing , base plate, j- bolts , secondary steel , excluding wastages,Installation of the steel structure with using heavy duty crane, scaffoldings , with safe work procedure, followed by 2 coat of the zinc rich primer and 2 coats of the Epoxy paint with Appropriate surface finish.The rate shall include cost and conveyance of all materials, aluminium frame works, labour charges, lead,lift As per standards, specification and directed by the Engineer-in-charge. (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
PARTITIONS WORKS Supply, fixing and installation of GI frame work with 12.5 mm double layer with Outer layer of 12.5mm thick gypsum plain Boards , Dry side and Inner layer wit 12.5mm thick mold & termite resistance with Glass matt reinforcement & inoganic coating on surface cladded on both sides of the framed structure with paint finish (Painting work shall be paid separately). (Overall thickness of partition 122mm) Partition from Finished flooring level till true ceiling level / MS frame work. Framework: Metal frame work, designed in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500 hrs of salt spray test as per ASTM B117, includes 70x34x36x0.5mm C-Stud with lip of 6.5mm and H-cutout on web enabling the services to pass, positioned at 407 mm c/c in 72x32x32x0.5mm Floor Channel & 72x32x32x0.5mm GypSerra Ceiling Channel with flanges bend at 5° acute angle, distance apart by 10 mm air gap & both the 48 mm C-stud braced with 50 mm floor channel at 1200mm c/c. Floor & Ceiling channel is anchored to the floor & True ceiling using Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} / X-GN20MX anchor fasteners at 600mm c/c in zig zag manner.Floor channel to be wrapped with 70µ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. inner & Outer layer of Boards to be Screw fixed with Drywall Screw of 25mm with 12nos per m2 & 35mm with 24nos per m2 at spacing of 600mm & 300mm respectively.Also to have an additional 19mm thick ply supports (wherever required) as spacer at the false ceiling level /as sub frames for doors/Fixing of Skiting /Panelling and glazed openings as per details or as per architects instruction. Infill: As an acoustic requirement, contractor to affix 50mm thick glass wool installation of density 20 kg/m3 in one metal frame cavity and wrapped in RP tissues suitably affixed to partition framework using necessary GI binding wire, duct tape as indicated in the drawing. Cladding: The framework to be cladded on both sides with double layer (from Finished floor level to till true ceiling level/ MS frame work )Outer layer of tapered edge 12.5 mm thick thick gypsum Plain(conforming to IS 2095 Part 1:2011, ISI Certified board) on DRY side and Inner Single layer of tapered edge 12.5 mm thick thick mold and termite resistant GlasrocH or Eq with Glass mat reinforcement & inorganic coating on surface, conforming to EN 15283-1 Type GM - FH1 ) in line and level screw fixed with 25mm drywall flat head screws @ 300mm c/c with staggered joints to avoid through joints and finished with proprietary supplied jointing tape and compound as per manufacturer's specification. Joints to be sand papered to achieve a smooth and seamless finish. Care must be taken that the plasterboards are raised 3mm from the floor and in this gap, chauking compound is injected, for successive layers and similarly for the ceiling channel/sections. Gypsum partition to be installed with corner bead to be applied at all corners.. The junction between partition & ceiling to be provided with 'L' shaped channel as per details. Special Provisions: Contractor to make provision for all electrical/networking boxes and to provide dia cut-outs/ Square cut outs/ Rectangle cut ots as required. Electrical/Network boxes/ other services to be provided at desired height and location as indicated in the drawing. All junctions between materials, columns, walls, etc. to have necessary groove with Aluminium `L' angle of 32x19/25x25 as per details.The junction of the partition with masonry & all penetration through the partition has to be treated with Hilti/suitable fire and acoustic sealant.. NOTE: Only partition area will be measured from end to end in square metre. The rate shall include all connectors, accessories, fastners, profiles, adhesive tapes, seals, making necessary opening for Electrical/Data/Voice switches and sockets and all required materials, providing & removing of necessary scaffolding work. Refer drawing AR/TD/107
Design ,Providing and fixing of curved curtain wall glazing, consisting of Pure polyester powder coated (coating thickness not less than 50-60 micron) extruded aluminium main frame of size 100x45x2mm as mullion and transom. The mainframe is designed to withstand the wind pressure of up to 180 kg/sqmt for an unsupported span of 3.6mt. Mainframe to be assembled with 5mm thick aluminium L cleats, bolts, nuts and fixing it to the RCC beam surface with hot dipped GI brackets, bolts, nuts and anchor fasteners. The glasses to be fixed on the main frame using the pressure plate section of size 10x53mm and the cover plate section of size 18.3 x57mm. EPDM gasket to be provided between mainframe, pressure plate and glass panels and complete with necessary screws and hardware– all complete as per size with following specification. Aluminium main frame: Mullion & Transom: 100x45x2mm Coating: Pure polyester powder coated (coating thickness not less than 50-60 micron) Design of the whole section: Design for wind pressure of 180 kg/sqm. The system shall be capable of withstanding movement in building due to expansion / contraction and earthquakes. Glass: 8mm thick clear toughened glass Panel size: As Approved. as per Design & drawings,material, Labour & wastages & Scaffolding Complete at all level as per Engineer In charge. The glass shall be heat soaked. The shop drawings and vetting of the design shall be under the scope of the contractor. The rate shall include the aluminium frame work and all necessary fittings,hardwares and GI brackets. (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work) Mode of Measurement : Curved measurement in plan, end to end shall be measured for payment.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately). For fixed portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing of urinal partitions with 10 mm thick frosted safety glass and fixed to the walls with suitable chrome finished Clamps as per manufacture's details . The rate is including all necessary hardware, fittings, material, labour, tools, lead, lift, scaffolding, all site arrangements, protection till final finish & handover, complete in all respects. Dimensions: depth 550 mm, Total Height 1900mm, As per standards, specification and directed by the Engineer-in-charge. Base Price: Rs 8600/- per piece, any deviation +/-, The purchase price ( excluding GST ) is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Providing and fixing Vanity counter of size in various Lengths , D-500mm with front facia of 50mm made by fixing 18mm marine ply board BWP grade conforming to IS-710 boxing to the toilet wall with adequate supports in form of MS bracket. Fixing 18-20mm thk pre polished granite ( paid seperately ) with araldite epoxy adhesive on top and sides of the counter, with mitered joints. making provision in the counter top for fixing counter sunk wash basin and for fixing tap. Including filling of matching colour epoxy mastic joining compound in all joints and cracks and polishing all edges and joints to a mirror polish.. The rate shall include all materials including structural works, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and as directed by the Engineer. Mode of Measurement : Plan area
Providing & fixing including 18mm thick Marine ply of BWP grade conforming to IS 710 grade paneling made out of 18mm thick marine ply wood board conforming to IS 710 fixed over MS Pates/section ,The ply shall be fixed with 6mm thick clear mirror with all sides CNC machine polish using mirror tape on sides and clear neutral silicon in center. The work shall include Required Edge profiles with powder quoted of approved shade ,provision for cutouts for cove light ,all materials, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts including structural works etc. all complete as per approved shop drawings and As per standards, specification and directed by the Engineer-in-charge.
Providing and fixing 18-20 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels and As per standards, specification and directed by the Engineer-in-charge. Base Price: RS. 220/Sft, any deviation +/-, The purchase price ( excluding GST ) of granite slab is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Location: Vanity counter Refer drawing AR/TD/103, AR/TD/104
Providing and fixing Aluminium Composite Panels of approved make and colour and color vapor-cured aluminum frames for exterior feature works made out of extruded aluminum sections with suitable pressure plate and cover plate. The aluminium composite panel should consist of 3mm thick thermoplastic core of anti-oxidant LDPE sandwiched between two skins of 0.5 mm thick aluminium alloy sheet making a total panel thickness of 4 mm. The surface shall be finished with PVDF based coating on the top side and service coating on the reverse side shall be with a polymer paint. Coating shall confirm to ECCA or AAMA. The panels shall be cut to size of required dimensions in line with site conditions, chamfered and be not using router machines and curved using standard rolling machines without leaving any marks in the corners. The system shall be designed to withstand a wind pressure of 150 kg/sqm. All clamps and brackets shall be hot dips galvanized minimum 80 microns thick and shall conform to IS: 4759-1996. The extruded aluminium section shall be anodized in approved colour with an anodic coating of minimum 50 microns. Extrude section shall be of 6063 T5 or T6 alloy confirming to ASTM B221. Any other fastening straps, nuts, bolts, rivets, washers, etc. shall be in stainless steel SS 304 grade. The joints shall be sealed with silicone sealant after inserting backer rod in the gap as requirement in the site.The mullions fitted to slab / beams by means clamps, fastening strips, nuts, bolts, rivets , washers and other fastening materials to suit the overall size. The work shall include all materials, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and As per standards, specification and directed by the Engineer-in-charge.
Supply and installation of vanity mirror of as per drawing including making mirror boxing of total depth 60mm using SS 'L angles fixed with angle cleated on all 4 corners, fixing 6mm extra clear mirror with all sides CNC machine polish with mirror tape on the frame edge with adequate support. The mirror shall have a square frosted band of 35mm width leaving 40mm distance from all 4 edges. Provision to be made for back lighting the inside the ss box. Including fixing Dimista pad behind the mirror to act as a defogger. The rate shall include mirror, all accessories all fittings The work shall include all materials, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and as directed by the Engineer. Refer drawing AR/TD/103, AR/TD/104
GLASS PARTITION Supply and Installation of Full height Extruded Aluminium Glazed partitions system of 100x45 mm thick section or as per Manufacture details for partitions Using section as verticles at the soild partion junction & sections of 50x33 thick or as per Manufactures details for Horizontals at Top & Bottom for Installing glass . The rate including of 25mm wide vertical , Horizontals & Intermediates at equal intervals as specified in drawings using sections 2nos of size required both the sides of the glass , Frame shall be finished powder coated (50-60 microns)of approved shade as per selction by the client/architects , cost of 10mm thick Toughened glass(heat soaked) with double sided adhesive tapes for glass to glass butt joints etc , as per Design & drawings,and rate shall include all material including aluminum extrusions, fittings , Labour & wastages & Scaffolding Complete at all level as per Engineer In charge. (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
Supply, fixing and installation of non load bearing fixed frame for fire resistant glazed Partition of 12mm thick clear for 120 minutes Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 minutes of both integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. The frame shall be filled with mineral wool insulation of density min 96kg/ m³ and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016 and directions of Engineer - in- charge. The rate inclusive of Material, Labour, providing & removing necessary Scaffolding, complete at all levels as per the Detailed drawings & Engineer Incharge .
Providing and Fixing hard wood battens of 12x25 mm with 8mm thick marine ply BWP garde conforming IS 710 to directly fixing on wall . The surfaces of hardwood finished with sand paper, filling of grains with wood filler and dent filler, applying approved wood stain for getting required shade applying two coats of PU sealer, two coats of PU top coat etc complete as per direction of Engineer in charge at all levels. The item shall be inclusive of cutting & making cutouts for lights, diffusers etc all complete. The rate is including cost and conveyance of all materials, labour charges, lead,lift, scaffolding at all heights ,PU finish etc complete as directed by Engineer- in-Charge. Only the exposed finish surface area without projections of battens shall be measured for payment.
Providing & fixing 13.52 mm thick laminated glass with inscription fixed to wall with 13.52 laminated toughened glass (highest quality type of annealed glass ),exterior grade weatherproofing silicone adhesive including all the necessary & all the required fixing materials, labours, tools, accessories, equipments etc to complete as per detailed architectural drawing & as directed by engineer incharge. -The glass (100% tempered toughened glass) shall meet the requirements as it should be 4-5 times stronger than normal annealed glass & all the edges to be polished with crystal clear glossy finish. -The laminated glass consists of three layers : 6mm thick clear float glass toughened (100% tempered toughened glass) +1.52 mm PVB lamination+6mm thick tru thick clear float glass toughened (100% tempered toughened glass). The glass should be heat soaked. -Rate to include lifting & shifting the materials to the required floors including scaffolding , all lead, lifts and as per specifications and standards as directed by the Engineer in charge (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
Providing & fixing 13.52 mm thick laminated glass top / skylight with 13.52 laminated toughened glass (highest quality type of annealed glass ),exterior grade weatherproofing silicone adhesive including all the necessary & all the required fixing materials, labours, tools, accessories, equipments etc to complete as per detailed architectural drawing & as directed by engineer incharge. -The fabrication framework not to be added in this item as it's separately captured in MS works. -The glass (100% tempered toughened glass) shall meet the requirements as it should be 4-5 times stronger than normal annealed glass & all the edges to be polished with crystal clear glossy finish. -The laminated glass consists of three layers : 6mm thick clear float glass toughened (100% tempered toughened glass) +1.52 mm PVB lamination+6mm thick tru thick clear float glass toughened (100% tempered toughened glass). The glass shall be heat soaked -Rate to include lifting & shifting the materials to the required floors including scaffolding , all lead, lifts and as per specifications and standards as directed by the Engineer in charge -Measurement : Area of glass skylight glass (LxB) (This shall be carried out by speciliazed agency having sufficient experience in the above work and ensure a warranty of 10 years. only skilled and experienced persons shall be employed for this work)
Providing & fixing 10mm toughened Fixed Glass, fixed with S.S. clamps on sides and top & S.S. 'U'-channel in the ground as per detail drgs. The work shall include Required Edge profiles with all materials, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and As per standards, specification and directed by the Engineer-in-charge.
Providing & fixing food display unit with glass made out of stainless steel frame work (SS 304 grade) as approved by the Engineer in charge ,The unit shall be made up 3 partitions of 8mm thick clear toughened glass placed in 3 layers with all sides CNC machine polish using mirror tape on sides and clear neutral silicon in center. The work shall include stainless steel framework, Required Edge profiles with powder quoted of approved shade ,provision for cove light ,all materials, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and As per standards, specification and directed by the Engineer-in-charge.
WALL CLADDING Providing and fixing 20mm thick IPE wooden wall panelling fixed to Aluminium framework made 25x50mm Aluminium frame as per the detail in drawing.The rate shall include all materials, aluminium framework, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and as directed by the EIC. Purchase Price of Tiles : Rs.400/Sqft, TThe purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Providing and fixing the Ply wood and finished with MDF with CNC cut as per detailed drawing cladded on the walll with 12mm thick marine grade ply conforming to IS 710 & 4mm MDF confirming to IS -710 on framework made in 50 x 25/ 50.8 x 25.4mm, 16swg (1.626mm thick and consider the tolerance range of 1.60 ~1.65mm) aluminium tube section framework, placed at 600mm c/c in both the directions at different levels and to shapes as per the detail drawings. The aluminium sections shall be placed at 600mm c/c both ways and rigidly connected together using 3mm thick aluminium L- cleats fixed/ fastened to aluminium section with double screws as per the detail drawings The framework shall be cladded with 12mm thick Marine grade plywood with 4mm MDF and CNC cut as per the detailed given by the architect to shape and size with grooves as per Architectural drawings etc.,The rate inclusive of base framework with aluminium,CNC cutting Finishing the joints , Material, Labour, providing & removing necessary Scaffolding, making cut out for electrical, cove lights & switches etc., complete at all levels as per the standards ,specificcations ,detailed drawings & Engineer In charge.
EXTERNAL ELEVATION WORKS Providing and fixing of curtain wall glazing, consisting of Pure polyester powder coated (coating thickness not less than 50-60 micron) extruded aluminium main frame of size 154.3x57x2mm as mullion and transom. The main frame is designed to withstand the wind pressure of up to 180 kg/sqmt for an unsupported span of 3.6mt. Mainframe to be assembled with 5mm thick aluminium L cleats, bolts, nuts and fixing it to the RCC beam surface with hot dipped GI brackets,bolts, nuts and anchor fasteners. The glasses to be fixed on the main frame using the pressure plate section of size 10x53mm and the cover plate section of size 18.3 x57mm. EPDM gasket to be provided between mainframe, pressure plate and glass panels and complete with necessary screws and hardware– all complete as per size with following specification. Aluminium main frame: Mullion & Transom: 154.3x57x2mm Coating: Pure polyester powder coated (coating thickness not less than 50-60 micron) Design:Design for wind pressure of 180 kg/sqm. The system shall be capable of withstanding movement in building due to expansion / contraction and earthquakes. Glass: 26mm DGU (8mm thick heat strengthened reflective glass + 12mm Air Gap + 6mm thick clear toughened glass) Panel size: As Approved. The glasses shall be heat soaked. The rate shall include the aluminium frameworks, all fittings and accessories including all lead,lift ,scaffolding at all levels and as directed by the Engineer in charge. (This shall be carried out by speciliazed agency having sufficient experince in the above work and only skilled and experienced persons shall be employed for this work and the contractor shall submit 10 years warranty)
EXTERNAL ELEVATION WORKS Providing and fixing of curtain wall glazing, consisting of Pure polyester powder coated (coating thickness not less than 50-60 micron) extruded aluminium main frame of size 154.3x57x2mm as mullion and transom. The main frame is designed to withstand the wind pressure of up to 180 kg/sqmt for an unsupported span of 3.6mt. Mainframe to be assembled with 5mm thick aluminium L cleats, bolts, nuts and fixing it to the RCC beam surface with hot dipped GI brackets,bolts, nuts and anchor fasteners. The glasses to be fixed on the main frame using the pressure plate section of size 10x53mm and the cover plate section of size 18.3 x57mm. EPDM gasket to be provided between mainframe, pressure plate and glass panels and complete with necessary screws and hardware– all complete as per size with following specification. Aluminium main frame: Mullion & Transom: 154.3x57x2mm Coating: Pure polyester powder coated (coating thickness not less than 50-60 micron) Design:Design for wind pressure of 180 kg/sqm. The system shall be capable of withstanding movement in building due to expansion / contraction and earthquakes. Glass: 15mm SGU Panel size: as approved. The contractor should submit shop drawings for the same and get it approved before execution. The glass shall be heat soaked and toughened. he rate shall include the aluminium frameworks, all fittings and accessories including all lead,lift ,scaffolding at all levels and as directed by the Engineer in charge. (This shall be carried out by speciliazed agency having sufficient experince in the above work and only skilled and experienced persons shall be employed for this work and the contractor shall submit 10 years warranty)
Providing and fixing of aluminum wooden finished powder coated (40 to 60 micron) extruded section of size 38x38x2mm square box section, fabricated and assembling as per the design requirement for the iconic mast given by the Architect using necessary cleats and screws, and to be installed on the MS main structure using necessary brackets and hardware's - all complete and as directed by the Engineer in charge Fin Elevation Face: 38mm Clear Gap: 50mm Refer drawing AR/TD/107, AR/TD/108
Providing and fixing of aluminum wooden finished powder coated (40 to 60 micron) extruded section of size 38x38x2mm square box section, fabricated and assembling as per the design requirement given by the Architect using necessary cleats and screws, and to be installed on the MS main structure using necessary brackets and hardware's - all complete Fin Elevation Face: 38mm Clear Gap: 100mm (This shall be carried out by speciliazed agency having sufficient experince in the above work and only skilled and experienced persons shall be employed for this work)
Supply, fabricate and install of MS Structure, the structure shall be either a welded or bolted system and materials used shall be ISMC/ISMB/box sections/Plates/Angles etc The steel grade shall conform to E-300. The rates are inclusive of loading, unloading, hoisting, etc. The structure shall be painted with one coat of primer and two coats of enamel paint all complete and as directed by the Engineer in charge. (This shall be carried out by speciliazed agency having sufficient experince in the above work and only skilled and experienced persons shall be employed for this work) Refer drawing AR/TD/107, AR/TD/108
Supply and fixing of “SELF SUPPORTED” SECRET FIX STANDING ROOFING SYSTEM IN 0.9mm THICK AA 3004 ALUMINIUM ALLOY. The general roof- construction shall comprise from bottom to top: (1) First Layer – Supply & Fixing of bare galvalume sheets in 0.50mm thick galvalume steel of 1000mm effective cover width and 35 mm height ribs in the pan at 200mm centre-to- centre.(2) Second Layer - Vapour Control Layer shall be a single layer of double-sided aluminium foil having thickness of 200 microns. (3) Third Layer- Top Hat bracket, 2mm thick.(4) Fourth Layer – Top Hat Batten, 1.6mm thick. (5) Fifth Layer – Aluminium Halters with thermal barrier.pads to be fixed to the sub purlins with SS 304 screws only.(6) Sixth Layer - One layer of Rockwool insulation of 150mm thickness, 60 kg/m3 density. (7) Seventh Layer - Top layer – Aluminium Tapered Curve Roof profile sheeting manufactured from aluminium self-supported standing seam roof system from aluminium alloy AA 3004 H44 (AlMn1Mg1) as specified in BS EN 1396: 2007 material thickness of 0.9mm with PVDF2 finish (standard colours) on the exposed surface. The profiled roof panel should have 3Nos of Mini ribs, Accessories, Fasteners. The material properties shall be as follows: Ultimate tensile strength: minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, Modulus of elasticity: 70,000 N/mm2. Sheets are to be laid to meet the requirements of the building geometry and fixed on Aluminium Halters. Halters to be fixed to the purlins with SS 304 screws. Appropriate accessories for Verge, Eave, Ridge shall be used to ensure the weather & water tightness at this point. (This shall be carried out by speciliazed agency having sufficient experince in the above work and only skilled and experienced persons shall be employed for this work and should ensure a warranty for 10 years)
Providing and fixing of 2 mm thick Aluminium gutter with double side vulcanized rubber Expansion joints at every 12m length. Necessary down take spout with diameter up to 150 mm at required intervals & other accessories like Cover plate, end caps and welding at joints. The Girth of gutter would be up to 3000mm. The rate shall include the vulcanised rubber expansion joints and all lead, lifts at all levels and scaffolding. (This shall be carried out by speciliazed agency having sufficient experince in the above work and only skilled and experienced persons shall be employed for this work and should ensure a warranty of 10 years)
Providing and fixing of Flashings manufactured from aluminium alloy AA 3004(AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and PVDF finish on the exposed surface. The flashing shall be of same colour as of roof. (This shall be carried out by speciliazed agency having sufficient experince in the above work and only skilled and experienced persons shall be employed for this work)
Painting Works Providing and Wall painting with premium acrylic emulsion paint of interior grade (2 or more coats),having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, required to achieve even shade and colour. The rate shall include all lead, lifts and scaffolding for the work and as per standards, specification and directed by the Engineer-in-charge
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.The rate shall include all lead, lifts and scaffolding for the work and as per standards, specification and directed by the Engineer-in-charge
Providing & applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. (for internal wall). The rate shall include all lead, lifts and scaffolding for the work and as per standards, specification and directed by the Engineer-in-charge
Providing & applying White washing with lime to give an even shade (for Ducts) New work (three or more coats) The rate shall include all lead, lifts and scaffolding for the work and as per standards, specification and directed by the Engineer-in-charge
Providing & Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying 2 or more coats required, to achieve even shade and colour.The rate shall include all lead, lifts and scaffolding for the work and as per standards, specification and directed by the Engineer-in-charge
Providing & Finishing with Deluxe Multi surface paint system for exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm (for External Walls) The rate shall include priming coat, all lead, lifts and scaffolding for the work and as per standards, specification and directed by the Engineer-in-charge
Providing and Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including water thinnable priming coat with cement primer.The rate shall include priming coat, all lead, lifts and scaffolding for the work and as per standards, specification and directed by the Engineer-in-charge
Providing & Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Providing and applying Exterior texture paint using Texture putty for 3-4mm thick and pattern and apply two coats of smooth finished weather coat with Exterior Grade Acrylic Emulsion Paint of approved shade, over a coat of primer with necessary scaffolding, curing etc. complete. Paint should be of anti flaking, anti fading and anti fungus qualities.The rate shall include for finishing the painting to obtain an even and uniform shade including all lead,lift and scaffolding complete and as per standards, specifications and as directed by Engineer in Charge. Purchase Price of textured paint : Rs.80/Sft, The purchase price ( excluding GST ) and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supply and application of Duco paint of approved color and make on MR grade Plywood/ exterior grade MDF partition wall and complete as per the detailed drawing or the instructions of the Architects/ Engineer-in-Charge including applying of primer (3-5 DFT), putty work, with preparation of surface ready for applying DUCO paint. The cost shall be inclusive of preparing the surface, applying primer, putty, necessary staging/ scaffolding ,lead,lift at all levels etc and complete as directed by the Engineer in charge
Providing and applying 3 coats (each of 5 micron thickness) of Epoxy paint of approved make and colour as per manufacturers specifications in the areas specified as per approved pattern, with all lead and lift and as directed by the Engineer in charge and as per approved design and specification etc. complete.
MISCELLANEOUS WORKS Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. as directed by the Engineer in charge and as per approved design and specification etc. complete
Providing Weep Holes of 63mm dia with PVC pipe of required length in reinforced concrete retaining wall with filler sock formed by wrapping 20mm crushed stone in non woven geotextile membrane including cost and conveyance of all materials labour, with all leads and lifts and as directed by the Engineer, as per approved drawings as per detailed tender specifications etc, complete
Making Grooves of size 6mm x 25mm deep during the grade slab concrete is green and suppling and applying polysulphide joint sealent of approved make in grooves including Backer Rod as shown in drawings.as directed by the Engineer in charge and as per approved design and specification etc. complete
Providing and applying of swellable type water stop tape, 19mm x25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.As directed by the Engineer in charge and as per approved design and specification etc. complete
Providing and fixing in position heavy duty PVC rungs of size 300X150X75mm including placing while doing formwork, aligning during concreting, grouting the junction if required, cleaning etc., as directed. The rate to include making openings in formwork and sealing after fixing the rungs including all lift leads and scaffoldings.As directed by the Engineer in charge and as per approved design and specification etc. complete
Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the (Grading 1 Material) with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in layers of 75mm thick in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Technical specifications. Rate shall include supply, loading and unloading, transportation, laying, roughening of surface, compacting, all materials, labour charges, machinery charges, etc required for the process complete. As directed by the Engineer in charge and as per approved design and specification as per MORTH clause 406.2
Construction of Granular Sub-Base by providing Coarse graded material (Grading I Material ), speading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per specifications and as directed by the Engineer. Rate inclusive of labour, materials, testing, machineries, all lead and lift etc. complete. As directed by the Engineer in charge and as per approved design and specification as per MORTH clause 401.2
MISCELLANEOUS WORKS - Above Plinth level Supplying & Installing Styrofill blocks (EPS 15), fill on clean, fairly even and dry surface. Before Placement of blocks, the surface should be cleaned to remove all debris and dust etc. Works inclusive of laying 75mm thick M20 Grade screed, Covering with Welded or Woven Mesh, which is fixed with the help of binding wire / “U” nails, Applying Hot Bituminous based compound Adhesive as per the manufacturer's specification in spot form on all sides of the block, except the top, so as to keep it in position while work is being carried out, all as per Manufacturer’s instructions upto all levels. The rate shall includes all material,labour, lead,lift and scaffoldings including the rate of screed and the application of hot bituminous based compound adhesive.
Providing and fixing of Rubber Column Guard to protect parking area columns made out of rubber of size 100 mm x 100 mm size, with curved corner at the center, with reflective stickers size length 1m (1000mm) and thickness 20mm including fixing in position with suitable nails / screws etc., complete and as per manufacturer specification complete all as directed by the Engineer in charge.
Providing and laying light weight cement concrete (Density 12KN/m3) of approved design mix, properly mixed and consolidated with hand rammers, adding admixtures in recommended proportion including cost and conveyance of all materials, labour, curing, lead lift , etc. complete for sunken floor filling as directed by Engineer-in-Charge at all levels.
LANDSCAPE WORKS Providing and plastering with clay mortar (mud plastering) 15mm thick with admixtures including necessary scaffolding, cost of all materials, all lead and lift and as directed by the Engineer in charge and as per approved design and specification etc. complete.
Supplying and fixing of 8mm thick drainage cells made of pressure-resistant dimpled sheet and laminated, filter-stable geotextile serves as a drainage layer and effectively protects pressure-resistant substrates from mechanical influences. The strips to have an integrated self-adhesive edges, Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust using temporary agronet, watering & maintenance at stacking area until planted as directed by EIC.
Supplying and stacking of good earth at site including royalty charges etc complete as directed by the Engineer in charge (earth measured in stacks as directed by the Engineer in charge and will be reduced by 20% for payment). - Red garden soil.
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete . (Manure shall be well composted, dried, well screened good quality in powdered form. Manure, shall be free from soil clods, fresh mung grass, and dry. Sample will be approved by Engineer in charge. ) (Cattle manure measured in stacks as directed by the Engineer in charge and will reduced by 8% for Payment).
Supplying and stacking at site Vermi compost from approved source for planting.grown. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust using temporary agronet, watering & maintenance at stacking area until planted as directed by EIC.
Supply and planting of Ground covers / creepers - well developed, min. 0.15m high, in polybag , disease free. All groundcover species shall be evenly balanced to allow equal growth in all directions. Plants shall have fully developed roots and leaves. Rooted cuttings will not be accepted. All plants to be container grown. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust using temporary agronet, watering & maintenance at stacking area until planted as directed by EIC. The period of maintainence is 6 months from the date of completion of the project and full payment shall be released after the completion of the free maintainence period.
Supply and planting of Shrubs - well developed, well branched - 3-4 branches each having 4-5 leaves, preferably in bloom, in polybag of 30x20cm size, disease free and development (height 0.75-0.9m) Shrubs are woody perennials of generally multi stemmed and bushy habit ranging from 3 - 4.5m down to 500mm height. Shrubs shall have no less than three main stems and shall be well balanced and bushy, with strongly developed fibrous root systems, and shall be pruned in advance as required to achieve the specified height tolerances. Branches shall break from the base of the plant just above the root collar, and shall be well furnished with leaves right down to ground level. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust using temporary agronet, watering & maintenance at stacking area until planted as directed by EIC.The period of maintainence is 6 months from the date of completion of the project and full payment shall be released after the completion of the free maintainence period.
Supply and planting of trees, palms and large shrubs using quadrapod staking made of 25 mm dia 2.5 metre long, fixed 0.3m in the soil and joined at 2/3 height of plant stem using jute rope, fixed to plant using rubber sheath; plant stem to be covered with gunny / jute cloth at fixing point to prevent damage, complete including supply of all material, labour and equipment, upto any lead and lift as directed by EIC.The period of maintainence is 6 months from the date of completion of the project and full payment shall be released after the completion of the free maintainence period.
Mixing of excavated earth with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately),complete including supply of all material, labour and equipment, upto any lead and lift as directed by EIC
Spreading of the manure or sludge made with the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) in a equal proportion towrds the plantation area ,flooding with water, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately),complete including supply of all material, labour and equipment, upto any lead and lift as directed by EIC
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m,complete including supply of all material, labour and equipment, upto any lead and lift as directed by EIC
Supply and fixing of 36" round tree grate (CT8-1011) over 50mm thick sand cushion bed to the required levels and slopes. spreading and brushing the fine sand into the joints into its final level. The work includes cost of sand, labour and equipment's such as cutting machines, lead, lift, loading & unloading to site, and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc..,complete including supply of all material, labour and equipment, upto any lead and lift as directed by EIC. The period of maintainence is 6 months from the date of completion of the project and full payment shall be released after the completion of the free maintainence period.
Supplying and fixing of antique sculpture as per the design and the specifications at site including lead and lifts etc. all complete as per approved shop drawings and As per directed by the Engineer-in-charge. Fabrication, erection of Coir sculpture of (size 2.0m x 1.0m x 1.0m) made of coir as per the design including chemical treatment for the exposed surface as per the specifications The work includes cost of all raw materials labour and equipment's such as cutting machines, lead, lift, loading & unloading to site, and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc..,complete. The purchase price is Rs 5,00,000/-. The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying and fixing of antique sculpture as per the design and the specifications at site including lead and lifts etc. all complete as per approved shop drawings and As per directed by the Engineer-in-charge. Fabrication, erection of Kalari sculpture of (size 2.0m x 0.9m) made as per the design including chemical treatment for the exposed surface as per the specifications The work includes cost of all raw materials labour and equipment's such as cutting machines, lead, lift, loading & unloading to site, and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc..,complete. The purchase price is Rs 3,50,000/-. The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying and fixing of antique sculpture as per the design and the specifications at site including lead and lifts etc. all complete as per approved shop drawings and As per directed by the Engineer-in-charge. Fabrication, erection of Hornbill sculpture of made of wood peices as per the design including chemical treatment for the exposed surface as per the specifications The work includes cost of all raw materials labour and equipment's such as cutting machines, lead, lift, loading & unloading to site,and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc,complete. The purchase price is Rs 3,75,000/-. The purchase price is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying and fixing of antique sculpture as per the design and the specifications at site including lead and lifts etc. all complete as per approved shop drawings and As per directed by the Engineer-in-charge. Human sculpture at Entry-2: Making and erection of Human sculpture as per the design including chemical treatment for the exposed surface as per the specifications The work includes cost of all raw materials labour and equipment's such as cutting machines, lead, lift, loading & unloading to site, and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc..,complete. Purchase Price ;Rs. 5,65,000/Each, The purchase price ( excluding GST ) is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying and fixing of antique sculpture as per the design and the specifications at site including lead and lifts etc. all complete as per approved shop drawings and As per directed by the Engineer-in-charge. Heritage Island Sculpture: Making and erection of sculptures as per the design including chemical treatment for the exposed surface as per the specifications The work includes cost of all raw materials labour and equipment's such as cutting machines, lead, lift, loading & unloading to site, and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc..,complete. Base Price ;Rs. 6,25,000/Each, The purchase price ( excluding GST ) is mentioned in basic price and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supply and installation of Living wall plant container system with all accessories as Living wall R4 module with a single cavity of 150 Cu Inches, cavities detachable to fit the size of the installation, with geofabric bag filled with Ecogrow substrate , planted with plants suitable for climatic & microclimatic conditions of Site including shade path, GI support member with related hardware, GI drain tray, basic irrigation system within Green wall ( emitter lines, supply lines & fittings), excluding pump controllers & solenoid valves.The work shall include all materials, labours, scaffolding, tools & tackles, any cut-out for services, leads and lifts etc. all complete as per approved shop drawings and as directed by the Engineer.The period of maintainence is 6 months from the date of completion of the project and full payment shall be released after the completion of the free maintainence period.
Providing and fixing GI vertical members made out of of Frame work to be 75X75X5.0mm thick with mentioned equal distance both ways(Horizontal/Vertical) or as directed. The vertical GI member shall be placed at equal center to center and horizontal members to be placed at c/c or as directed by the Engineer as per site conditions with necessary grooves and cuts etc. The work includes cost of equipment's such as cutting machines, lead, lift, loading & unloading to site, and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc..,complete.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and laying of of River (Stone) Pebbles size of 50mm and down size in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of EIC
Supply and installation of vertical green wall Living ceiling container system with all accessories as vertical garden Living ceiling planter carrier made up of FRP or GRC or Aluminium according to the site conditions with a single cavity of 180 Cu Inches, basic irrigation system within Green wall (emitter lines, supply lines & fittings), excluding pump controllers & solenoid valves.The work includes cost of equipment's , lead, lift, loading & unloading to site, and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc..,complete.The period of maintainence is 6 months from the date of completion of the project and full payment shall be released after the completion of the free maintainence period.
Supply and installation of green wall planted sandwitches filled with hydrophilic foam substrate, planted with plants suitable for climatic & microclimatic conditions of site including shade pat for living ceiling container system as directed by the Engineer as per site conditions . The work includes cost of equipment's ,lead, lift, loading & unloading to site and all other incidental charges required for the successful completion of the works as per the design, drawings and details etc..,complete.The period of maintainence is 6 months from the date of completion of the project and full payment shall be released after the completion of the free maintainence period.
Softscaping works can include flowers, plants, shrubs, trees, flower beds, and duties like weed/nuisance management, grading, planting, mowing, trimming, aerating, spraying, and digging etc., for everything from plants and shrubs to flower beds- as per detailed specifications and drawing As per standards, specification and directed by the Engineer-in-charge.
Description of Work / Item(s)
Amount
Supplying, installing, testing and commissioning approved make PN-25 Forged Brass body ball valves standard type confirming IS 1703-1977 with screwed ends, necessary unions etc., complete and as directed by the engineer incharge.. a) 25mm dia ( For ARV and inside the pump room in Manifold )
Supplying, installing, testing and commissioning approved make Forged Brass 25mmdia AUTOMATIC AIR RELEASE VALVE, IS 210 with necessary Unions etc., complete and as directed by the engineer incharge.. a) 25mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves PN16 standard lever type confirming to IS 13039 with necessary flanges, nuts & bolts, Neo prene gaskets etc., complete and as directed by the engineer incharge.. - 250mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves PN16 standard lever type confirming to IS 13039 with necessary flanges, nuts & bolts, Neo prene gaskets etc., complete and as directed by the engineer incharge.. - 200mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves PN16 standard lever type confirming to IS 13039 with necessary flanges, nuts & bolts, Neo prene gaskets etc., complete and as directed by the engineer incharge.. - 150mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves PN16 standard lever type confirming to IS 13039 with necessary flanges, nuts & bolts, Neo prene gaskets etc., complete and as directed by the engineer incharge.. - 100mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves PN16 standard lever type confirming to IS 13039 with necessary flanges, nuts & bolts, Neo prene gaskets etc., complete and as directed by the engineer incharge.. - 80mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves PN16 standard lever type confirming to IS 13039 with necessary flanges, nuts & bolts, Neo prene gaskets etc., complete and as directed by the engineer incharge.. - 65mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves PN16 standard lever type confirming to IS 13039 with necessary flanges, nuts & bolts, Neo prene gaskets etc., complete and as directed by the engineer incharge.. - 50mm dia
Supplying, installing, testing and commissioning approved make CI Gate valves Wheel operated type PN 16 confirming to IS 778 with necessary flanges nuts & bolts, Neoprene rubber gaskets etc., complete and as directed by the engineer incharge.. - 300mm dia
Supplying, installing, testing and commissioning approved make CI Gate valves Wheel operated type PN 16 confirming to IS 778 with necessary flanges nuts & bolts, Neoprene rubber gaskets etc., complete and as directed by the engineer incharge.. - 250mm dia
Supplying, installing, testing and commissioning approved make CI Gate valves Wheel operated type PN 16 confirming to IS 778 with necessary flanges nuts & bolts, Neoprene rubber gaskets etc., complete and as directed by the engineer incharge.. - 200mm dia
Supplying, erecting and commissioning fire hose cabinet comprising of:- i) 63 mm dia Stainless steel instantaneous 'pattern single headed hydrant 'valve to 'be provided at each floor lvl. ii 2 length of 15M. 63mm dia 'R.R.L hose with Stainless steel coupling, IS : 636 Type-A iii 1 no. SS branch pipe with nozzle IS:903 iv) 1no. 19mm reinforced rubber hose reel 40m long with M.S. drum. v) Necessary Orifice plates to be provided near the Hydrant Valves at each floor level. vi) The frame & cover shall comprise of 1000mm wide x1200mm highX200mm depth frame & door made of 16 gauge MS sheet to house the above accessories. The frame & cover shall be firmly fixed to the wall with expansion bolts. The frame & cover shall be powder coated both internally and externally with fire red colour. The door shall be made of angle iron frame and fixed with 4mm thick glass. The door shall be provided with suitable locking arrangement, including gi nipples/hydrolic adopter.
Supplying, installing and commissioning first aid fire fighting appliances confirming to IS standards.( with pressure gauge & stand) - Multi Purpose ABC Type( Electrical room) - 'Capacity : 6 Kg.
Supplying, installing and commissioning first aid fire fighting appliances confirming to IS standards.( with pressure gauge & stand) - Multi Purpose ABC Type CO2( Inside the lift & kitchen) - 'Capacity : 2.0 Kg.
Supplying, installing and commissioning first aid fire fighting appliances confirming to IS standards.( with pressure gauge & stand) - Mechanical Foam type fire exstinguishers - ( Near staircase, dg & transformer yard) - Capacity - 9 Liters
Supplying, installing and commissioning first aid fire fighting appliances confirming to IS standards.( with pressure gauge & stand) - Mechanical Foam type fire exstinguishers - ( Near staircase) - Capacity - 4 Liters
Supplying, fixing and testing approved make C.I dual plate check valve slim seal PN16, IS 5312(Part-1)-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 250mm dia
Supplying, fixing and testing approved make C.I dual plate check valve slim seal PN16, IS 5312(Part-1)-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 200mm dia
Supplying, fixing and testing approved make C.I dual plate check valve slim seal PN16, IS 5312(Part-1)-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. -150mm dia
Supplying, fixing and testing approved make C.I dual plate check valve slim seal PN16, IS 5312(Part-1)-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 100mm dia
Supplying, fixing and testing approved make C.I dual plate check valve slim seal PN16, IS 5312(Part-1)-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 80mm dia
Supplying, installing, testing and commissioningapproved make ANSI Class 125/150 Cast Iron body brass PN-16 'Y' strainer with necessary flanges, nuts & bolts Noeprene Rubber Gaskets etc., complete and as directed by the engineer incharge. for terrace lines. - 300mm dia
Supplying, installing, testing and commissioningapproved make ANSI Class 125/150 Cast Iron body brass PN-16 'Y' strainer with necessary flanges, nuts & bolts Noeprene Rubber Gaskets etc., complete and as directed by the engineer incharge. for terrace lines. -250mm dia
Supplying, installing, testing and commissioningapproved make ANSI Class 125/150 Cast Iron body brass PN-16 'Y' strainer with necessary flanges, nuts & bolts Noeprene Rubber Gaskets etc., complete and as directed by the engineer incharge. for terrace lines. - 200mm dia
Supplying, installing, testing and commissioningapproved make ANSI Class 125/150 Cast Iron body brass PN-16 'Y' strainer with necessary flanges, nuts & bolts Noeprene Rubber Gaskets etc., complete and as directed by the engineer incharge. for terrace lines. - 150mm dia
Supplying, installing, testing and commissioning approved make 15mm brass sprinkler bulbs concealed type K-80,RTI>50 designed to operate at 68deg.C with rosset plate of 0.8 mm thick, necessary etc., complete and as directed by the engineer incharge..UL/FM Approved.
Supplying of approved make 15mm brass sprinkler bulbs pendent type K-80,RTI>50 designed to operate at 68deg.C with rosset plate of 2mm thick, necessary etc., complete and as directed by the engineer incharge..( below false ceiling in common area )UL/FM Approved.
Fixing, testing and commissioning approved make 15mm brass spare sprinkler bulbs pendent K-80,RTI>50 designed to operate at 68deg.C etc., complete and as directed by the engineer incharge..UL/FM Approved.
Supplying of approved make 15mm brass sprinkler bulbs upright type K-80,RTI<=50 designed to operate at 68deg.C with necessary etc., complete and as directed by the engineer incharge.. (For Above False ceiling Area in base building scope ) UL/FM Approved.
Fixing, testing and commissioning approved make 15mm brass spare sprinkler bulbs upright type K-80,RTI<=50 designed to operate at 68deg.C etc., complete and as directed by the engineer incharge..UL/FM Approved.
Supplying of approved make 15mm brass sprinkler bulbs Side Wall Mounted type K-80,RTI<=50 suit to working pressure designed to operate at 68 deg.C etc., complete and as directed by the engineer incharge. with rosset plate of 2mm thick.UL/FM Approved.
Fixing, testing and commissioning approved make 15mm brass spare sprinkler bulbs Side Wall Mounted K-80,RTI<=50 suit to working pressure designed to operate at 68 deg.C etc., complete and as directed by the engineer incharge. with rosset plate of 2mm thick.UL/FM Approved.
Supplying, installing, testing and commissioning approved make Flow Switch with necessary Flanges, Bolts nuts, etc., complete and as directed by the engineer incharge.. a) 50mm dia
Supplying, installing,testing and commissioning approved make flexible control wires 1.5sqmm made of PVC insulated copper conductor, PVC sheathed,confirming to IS 1554 etc., complete and as directed by the engineer incharge. as per detailed specification.( from flow switch to monitor module & FAMCP)
Supplying and providing PCC 1:3:6 Support Pedestals below Fire Hydrant Header lines with M.S brackets clamps, etc complete and as directed by the engineer incharge. (terrace level)
Supplying, installing and commissioning of fire brigade inlet connection comprising of 4 nos. 63 mm dia ss hydrant valves with Built in G.M non-return valve of instantaneous spring loaded coupling type, arranged on 150mm dia pipe manifold and connected to the wetriser mains with CI butterfly valve & M.S.Cabinet of suitable size with mounting supports etc.,
Supplying, installing SS yard hydrant comprising of 80 mm dia pipe fitted with single headed 63 mm dia landing valve as per design and providing 30.0 m long 63 mm dia R.R.L hose in MS cabinet with glass door and supporting frame etc., complete and as directed by the engineer incharge..
Providing, coating and Wrapping of Buried G.I.pipes with 2 mm thick pypkote Pipe Qty. include in item no. 1 - 150mm dia
Providing, coating and Wrapping of Buried G.I.pipes with 2 mm thick pypkote Pipe Qty. include in item no. 1 - 100mm dia
Providing, coating and Wrapping of Buried G.I.pipes with 2 mm thick pypkote Pipe Qty. include in item no. 1 - 80mm dia
Supplying, installing, testing and commissioning approved make sprinkler alarm valve complete and as directed by the engineer incharge. with approved water gong, test/drain valve assembly etc., a) 150mm dia
Pump room works : a) Supplying,fabricating and installing M.S.Fabricating supports comprising of M.S Angle/Box sections of suitable cross section.( inside the pump room)
b) Supply,installing pre-fabricated slotted hot dip G.I Cable trays for cable works inside the pump room 300 mm wide with necessary supports.
c) Supply,installing pre-fabricated slottedhot dip G.I Cable trays for cable works inside the pump room 150 mm wide with necessary supports.
Supplying,installing and commisioning PN16 metallic Expansion Bellows for Suction and discharge Lines including all necessary supports, flanges, neoprine rubber gaskets, nuts,bolts etc., complete and as directed by the engineer incharge.. - 250mm dia
Supplying,installing and commisioning PN16 metallic Expansion Bellows for Suction and discharge Lines including all necessary supports, flanges, neoprine rubber gaskets, nuts,bolts etc., complete and as directed by the engineer incharge.. - 200mm dia
Supplying,installing and commisioning PN16 metallic Expansion Bellows for Suction and discharge Lines including all necessary supports, flanges, neoprine rubber gaskets, nuts,bolts etc., complete and as directed by the engineer incharge.. - 150mm dia
Supplying,installing and commisioning PN16 metallic Expansion Bellows for Suction and discharge Lines including all necessary supports, flanges, neoprine rubber gaskets, nuts,bolts etc., complete and as directed by the engineer incharge.. - 100mm dia
Supplying,installing and commisioning PN16 metallic Expansion Bellows for Suction and discharge Lines including all necessary supports, flanges, neoprine rubber gaskets, nuts,bolts etc., complete and as directed by the engineer incharge.. - 80mm dia
Supplying, fabricating, installing, testing and commissioning M.S. AIR CUSHION vessel made of 4mm thick sheet metal etc., complete and as directed by the engineer incharge. with Heavy duty Bladder with 32mm dia ARV. Size :- 250mm diax1000mm long.
Supplying., Installing, testing & commissioning approved make Centrifugal Pump Single stage end suction type coupled to 2 Pole TEFC Electric motor with IP-55 Protection,Claas `F' insulation of suitable HP,fitted on a common base frame and rated for Fire duty.The quoted price shall also include 2 nos. Pressure gauges fitted on suction & delivery sides of the pump. The pumps shall run on 400/440V, 3ph,50Hz electric supply. Main Electrical Hydrant Pump Duty of pump : 2280 Lpm @ 75.0 m Head
Supplying., Installing, testing & commissioning approved make Centrifugal Pump Single stage end suction type coupled to 2 Pole TEFC Electric motor with IP-55 Protection,Claas `F' insulation of suitable HP,fitted on a common base frame and rated for Fire duty.The quoted price shall also include 2 nos. Pressure gauges fitted on suction & delivery sides of the pump. The pumps shall run on 400/440V, 3ph,50Hz electric supply. Main Electrical sprinkler Pump Duty of pump : 2280 Lpm @ 75.0 m Head
Supplying, Installing, testing and commissioning electrically driven Jockey Pump Single stage Vertical type coupled to 2 Pole TEFC Electric motor with IP-55 Protection,Claas `F' insulation & S.S. Impeller of suitable capacity 180.0 Lpm @ 75m. head with all the necessary accessories viz.Pressure gauges 2 nos. etc., operating on 3Ph 50Hz,400/440V AC supply including foundation, bolts etc., complete and as directed by the engineer incharge..
Supplying, Installing, testing and commissioning of fire hydrant Single stage pump capable of delivering 2280 Lpm @ 75.0 m Head coupled to water cooled Diesel Engine of adequate HP and couplete set shall be mounted on the common base frame, battery of 12v X 2nos, battery charger and battery leeds the qouted price shall includes water cooling piping. It shall be fitted with a heat exchanger on a common base frame with complete and as directed by the engineer incharge. ancillary units such as cooling system, fuel tank of 6hrs operation with standard and gauge glass and fuel piping with valves,Pressure guage,pressure switch etc., complete and as directed by the engineer incharge..(Common standby Pump for Hydrant and Sprinkler System).
Supplying., Installing, testing & commissioning approved make Centrifugal Pump Single stage end suction type coupled to 2 Pole TEFC Electric motor with IP-55 Protection,Claas `F' insulation of suitable HP,fitted on a common base frame and rated for Fire duty.The quoted price shall also include 2 nos. Pressure gauges fitted on suction & delivery sides of the pump. The pumps shall run on 400/440V, 3ph,50Hz electric supply. Water Curtain pump Duty of pump : 1620 Lpm @ 60.0 m Head
Supply, Installation, Testing & commissioning of approved make 25 mm dia SS flexible sprinkler drop pipes upto 1000 - 1200mm long suitable to operate @15b with suitable grid supports.(in Common Area)
Supplying, fabricating, fixing of approved make pipe support system for Fire fighting water lines inside the shafts/ceiling comprising of the following MS angles iron brackets with GI clamps, GI nuts & bolts, hitech supports etc complete and as directed by the engineer incharge.s as per drawing( refer shaft sectional dwg) The above shall be suitably painted with one coat of Zinc Oxide two coats of enamel paint over a coat of anticorrosive primer.This support system to be provided at 3.0m from c/c for verticle lines in shaft and 3.0m from c/c for horizontal lines laid in the ceiling
Supplying, installing, testing and commissioning approved make Nickel Chrome/ Brass finished 20mm dia water curtain nozzles K-Factor = 23, rated working pressure 12.5kg/sq.cm etc., complete and as directed by the engineer incharge. for Basement every 3000 sq.m area.
Supplying, installing, testing and commissioning approved make 100mm dia electrically operated deluge valve with rated working pressure 12.5kg/sq.cm etc.for water curtain system.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete and as directed by the engineer incharge. as required.
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete and as directed by the engineer incharge. with emitter and receiver including connections with remote test features etc complete and as directed by the engineer incharge. as required.UL/FM Approved.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete and as directed by the engineer incharge. with mounting base complete and as directed by the engineer incharge. as required.UL/FM Approved.UL/FM Approved.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete and as directed by the engineer incharge. with base as required. pantry & DG area )UL/FM Approved.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete and as directed by the engineer incharge. as required.UL/FM Approved.
Supplying, installation, testing & commissioning of fault isolator complete and as directed by the engineer incharge. with base as required.UL/FM Approved.
Supplying, installation, testing & commissioning of addressable fire control module complete and as directed by the engineer incharge. as required.UL/FM Approved.
Supply,Installation,Testing & Commissioning of Analogue Addressable Monitor module having Rotary, decimal addressing system for monitoring the field devices & shall be capable of providing DPDTcontact rated at 24v DC, 2A for auto level control at OHT, UGR, Flowswitch etc.,( mcp)UL/FM Approved.
Supply,Installation,Testing & Commissioning of Analogue Addressable Monitor module having Rotary, decimal addressing system for monitoring the field devices & shall be capable of providing DPDTcontact rated at 24v DC, 2A for sprinkler line flow switches to FAMCP panel & flow switch.UL/FM Approved.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete and as directed by the engineer incharge. with all connections etc as required.UL/FM Approved.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete and as directed by the engineer incharge. as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete and as directed by the engineer incharge. as required.For Repeated Panel
Supplying, installation, testing & commissioning of addressable manual call point complete and as directed by the engineer incharge. as required.UL/FM Approved.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete and as directed by the engineer incharge. as required.UL/FM Approved.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete and as directed by the engineer incharge. as required.for ICV.UL/FM Approved.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete and as directed by the engineer incharge. as required.for ICV/FAMCP connectivity
Supplying, installing, testing and commissioning approved make Solid state amplifier with amplifier rack.Ampliflier shall be of 200 WRMS output, 1No. amplifiers, with complete and as directed by the engineer incharge. wiring and controls, accessible from the front.
Supplying, installing, testing and commissioning approved make multi-strand twin core1.5 sq.mm cross-section Flexible FRLS control cables made of PVC insulated copper conductor, PVC sheathed, confirming to IS 694 etc., complete and as directed by the engineer incharge. as per detailed specification.
Supply of wall mount type speakeres 6 W with metal box enclosure, Talk Back faciltiy and Unit shall be complete in all respect comatable with PA system supplied
SITC of 6W Ceiling /Wall mounted Speakers
Supplying, installing, testing and commissioning approved make 25mm dia 2 mm thick.PVC Conduits with junction box, collars bends etc.
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut,PVC non-reflective self adhesive vinyl painted foam board, complete and as directed by the engineer incharge. with mirror fasteners. Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" OF 1.25 cm height letters in red with white back ground. The size of the board shall be 25cm x 30cm and shall be fixed at the height of 2 mts. From finished floor near Manual call points.
Floor identification signage(ie., GROUND FLOOR…..etc) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm x 60cm.
Providing and fixing in position the signages "Fire Order" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyl painted foam board of 3' x 4'
Type - 1' comprising of the following matter: Alert the security at security room by actuating manual call points located at strategic locations. Evacuate the occupants by using fire exits and emergency exits only and assemble at various assembly points. If possible, try to extinguish the fire by using nearest/suitable portable extinguisher or water from nearest wet riser. Be calm and do not give any room from panic, walk, do not run If you encounter serious difficulty in evacuation, flat and try to attract attention of rescue team.
Type - 2' comprising of the following matter: Action by security/Reception upon receipt of information through Fire Alarm or fire detectors or by using Public address system. Alert the occupants by using public address System. Inform Fire control through any one of the following Phone numbers:101/ 22251780/ 22251781 / 22251782 Refer evacuation plan for evacuating people Guide the Fire Force, on their arrival to the seat of fire. In case of the casualties, call Ambulance by Dialing number… Fire Fighting Agency………………….. Phone:…………………………. Fax:…………………………
Description of Work / Item(s)
Amount
ELECTRICAL WORKS RMU PANEL Supply of 12kV metal enclosed, manually operated SF6 Ring Main unit (indoor type) as per the technical specifications with 2 nos. 630A Load Break Switches as incomer & 2 nos. Vacuum Circuit Breaker 1250A rated and with a short circuit rating of 25kA for 3 sec in SF6 insulated stainless steel enclosure as outgoing complete with all accessories, RYB indications, ON/OFF indication etc,as per the SLD and detailed technical specifications.. The outgoings should be with Electrically operated draw out type VCB, with indication lamps, analogue and digital ( V,I,KVA,KWH etc) meters with communication port, numerical protection relays with communication port, required number of Current Transformer resin cast type of 150/5- Dual Core ( Core 1 -15 VA Class 0.5 for Metering, Core 2 – 15 VA 5 P 10 for Protection) .The outgoings should also have microprocessor based three phase over current and earth fault relays and transformer protection relays with Battery and battery charger. All indications, protection relays and necessary accessories shall be provided as per the SLD 11kV,1250A,350MVA,25kA 3 ph, 50 Hz Al Bus bar with BUS PT The RMU should be provided with Manometer for indicating SF6 gas pressure with green zone marked on the scale.
Installation, testing & commissioning of 12kV RMU as mentioned in item 1.1 including minor civil works as required. The ITC should be carried out as per the technical specifition.
TRANSFORMER :DRY TYPE for Indoor application 1600KVA 11KV/0.433KV Resin Cast Transformer -T1 Design, fabrication and supply of indoor type 1600 kVA, 11kV/433V 3 Ph, 50 Hz, dry type, vector group DYN -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer with IP23 enclosure as per IS 11171 : 1985. The transformer shall connected Delta on HV side and Star on LV side with OFF Load Tap Changer in steps of + 5% to -5% in steps of 2.5%. The transformer shall also have thermal relay(49W). The transformer shall have neutral CT 500/5A 10VA 5P10 with suitable enclosure on earthed star point with connector for connection to low set earth fault relay, winding temperature alarm and trip, HV cable box suitable for termination of HT XL PE cable and LV chamber suitable for termination of 2500A busduct , necessary power and control cabling for alarm, tripping & indication, and complete with all standard fittings and accessories etc including necessary louvers with provision for cooling fan/duct as required complete and as per specifications attached in all respects as required and necessary control cabling for alarm, tripping, supply of emergency trip push button & indication as required.The transformer losses shall be as per latest ECBC standards. Voltage Ratio: 11/0.433 kV Type of Winding: Copper, Fittings: Standard fittings as per IS:2026/77 & IS 111 71.
TRANSFORMER Installation, testing and commissioning of DRY type indoor 1600 kVA,11kV/433V 3 Ph, 50Hz, dry type, vector Dyn -11 Transformer including hoisting to the respective location, bolting the units, checking all the control and power cabling,Calibration of all measuring instruments, precommissioning checks,all the tests at site as per standards etc complete and as detailed in technical specification.
Supplying of 500kVA Diesel Generating Set on existing CC platform comprising of Diesel Engine @ 1500RPM confirming to BS 5514.The engine should be turbocharged,radioter cooled with 10% over load for 1hour in every 12 hours of operation coupled to suitable capacity alternatorrated at 415V ,0.8pf (lag) 50Hz,3phase ,4 wire system,confirming to BS 5000/IS 4722 as per the technical specifications.The alternator shall be of brushless type screen protected,revolving field .mounted on suitable channel Iron. 990Ltrs Fuel Tank along with pipe line, required nos.of Batteries of 12/24V as per requirement with battery charger having provision for boost and float charging,indications, DC ammeter and DC voltmeter, Acoustic enclosure as per CPCB -4 approved Norms. Engine Control unit shall be provided with the DG for the protection of Engine and Alternator.
Erection,testing and commissioning of 500kVA Diesel Generating Set on existing CC platform comprising of Diesel Engine @ 1500RPM confirming to BS 5514.The engine should be turbocharged,Air/water cooled with 10% over load for 1hour in every 12 hours of operation coupled to suitable capacity alternatorrated at 415V ,08pf (lag) 50Hz,3phase ,4 wire system,confirming to BS 5000/IS 4722 as per the technical specifications.The alternator shall be of brushless type screen protected,revolving field .mounted on suitable channel Iron Base Frame,complete with suitable capacity Fuel Tank, required nos.of Batteries of 12/24V as per requirement, Acoustic enclosure as per CPCB -4approved Norms.
EXHAUST PIPING The system shall comply with the norms of CPCB/ other statutory bodies. 6 mm thick MS pipes as per IS 3589 shall be supplied. The exhaust system including the Residential silencer must be sized to ensure that back pressure on system does not exceed the back pressure recommended by engine manufacturer.Design calculation in support shall be submitted for approval on award of contract. Pipe shall be painted with heat resistant paint after fabrication and erection. Flexible expansion joint of multiple corrugated stainless steel shall be provided between engine exhaust manifold and exhaust piping. Silencers and Horizontal runs shall be supported on spring supports. Vertical runs to have expansion bellows where length exceeds 25 M. The rate shall include cost of suitable steel supporting structure and painting. Exhaust Pipe MS pipe of 8" dia
Supply and fabrication of Steel support for exhaust pipe with DG Stack
Thermal insulation 8" dia DG Exhaust pipes including silencer inside the DG Room shall be thermally insulated using 200mm thick rock wool fibre/white glass wool fibre with aluminium sheet cladding over it for the length of the exhaust pipe inside the DGRoom. Nett resultant outer surface temperature shall not exceed 60 deg. C when the engine is running at full load.
Supply of 2500A ,415V, 50 kA, 50Hz AC TPN Sandwich Aluminium Bus Duct with 100% neutral Bus made out of 14 SWG powder coated and painted extruded Aluminium IP54 enclosure, flexible end termination, fittings & accessories like elbows, offset sections, tees, reducers, adaptor boxes, flanges , flexible connections , expansion joints, ground strips , suitable supporting arrangement with metal suspenders/ brackets provision for fixing 2 runs of 25x6mm Cu earth strip throughout the length of busduct etc. as required complete. (The rate shall be quoted for running meter and the elbows, bends, adaptor boxes are also measured under running meter and the rate shall be inclusive all associated accessories. Refer drawing &Technical specification for more details,(From Transformer to EB/Dg Panel and DG Sync panel to EB/DG Panel)
Installation of 2500A ,415V, 50 kA, 50Hz AC TPN Sandwich Aluminium Bus Duct with 100% neutral Bus made out of 14 SWG powder coated and painted extruded Aluminium IP54 enclosure, flexible end termination, fittings & accessories like elbows, offset sections, tees, reducers, adaptor boxes, flanges , flexible connections , expansion joints, ground strips , suitable supporting arrangement with metal suspenders/ brackets provision for fixing 2 runs of 25x6mm Cu earth strip throughout the length of busduct etc. as required complete. The rate shall be quoted for running meter and the elbows, bends, adaptor boxes are also measured under running meter and the rate shall be inclusive all associated accessories. Refer drawing &Technical specification for more details This should include all accessories required for fixing the support arrangement for busduct like threaded rod, MS items like angles, channels,plates and flats with Anchoring hardware, duly painted/powder coated etc.,(From Transformer to EB/Dg Panel and DG Sync panel to EB/DG Panel)
Installation, Testing and Commissioning of "DG SYNC" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "Main EB/DG" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "Main BLOCK PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "CHILLER PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "CHILLER PUMP PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "SUBSTATION LIGHTING AND POWER PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "GROUND FLOOR PANEL " including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "FIRST FLOOR PANEL " including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "SECOND FLOOR PANEL" including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Installation, Testing and Commissioning of "PHE PANEL, VENTILATION PANEL, MAIN LIFT PANEL, UTILITY PANEL, APFCR PANEL,common area PANEL " including hoisting to the respective location, assembling of panels, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, precommissioning checks, all the tests at site as per standards etc complete and as detailed in technical specification.
Supply of 3C X 300 sq.mm. (11kV unearthed) XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11/11 KV grade conforming to IS 7098 and other relevant standards amended upto date.(Refer Technical specifications)
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 400Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 240Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 185Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 150Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 120Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 95Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 70Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 50Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 35Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 3.5C 25Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 4C 25Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 4C 16Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 4C 10Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 4C 6Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed,armoured 4C 4Sq.mm Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured 3C 10Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured 4C 6Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured 4C 4Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured 3C 6Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade PVC sheathed, armoured 3C 4Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade PVC sheathed, armoured 3C 2.5Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade PVC sheathed, armoured 24C 2.5Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade PVC sheathed, armoured 12C 2.5Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 1.1 KV grade PVC sheathed, armoured 2C 2.5Sq.mm Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of PVC sheathed, multistranded 1C 16Sq.mm Copper conductor cable conforming to IS specifications
Laying of 1 number 3C X 300 sq.mm. (11kV unearthed) XLPE insulated PVC sheathed power cable of 11kv grade direct in ground including excavation to a depth of 1.2m, quarry sand cushioning (7.5cm + 10 cm) protected with solid concrete block of size 200x300x500 made of 1:2:4 concrete laid breadth wise and refilling as required
Laying of 1 number 3C X 300 sq.mm. (11kV unearthed) XLPE insulated PVC sheathed power cable of 11kv grade direct in ground additionally in same trench in one tier horizontal formation including excavation to a depth of 1.2m, quarry sand cushioning (7.5cm + 10 cm) protected with solid concrete block of size 200x300x500 made of 1:2:4 concrete laid breadth wise and refilling as required
Laying of one no. XLPE insulated and PVC sheathed power cable of grade 11kV of 3 Core 300sqmm in existing RCC trench / open duct / hume pipe / metal pipe / cable tray as required.
Laying of one number of 120sq. mm to 400 Sq.mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground at a depth of 1m including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number of 35 sq. mm to 95 Sq.mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground at a depth of 1 m including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number upto 35 sq. mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground at a depth of 1 m including excavation, sand cushioning, in 63 mm DWC HDPE pipe and refilling the trench etc as required. The supply of DWC pipe and other accessories is under the scope of the contractor.
Laying of one number from 120sq. mm to 400 Sq.mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground additionally in the same trench in one tier horizontal formation at a depth of 1 m including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number above 35 sq. mm to 95 Sq.mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground additionally in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number Upto 35 sq. mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground additionally in the same trench in one tier horizontal formation including excavation, sand cushioning, in 63 mm DWC HDPE pipe and refilling the trench etc as required. The supply of DWC pipe and other accessories is under the scope of the contractor.
Laying of one number 120 sq. mm to upto 400 sq. mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade in the existing masonry open trench/duct/hume pipe/cable tray/surface including MS flat clamp 40x3mm, saddle and etc..
Laying of one number PVC insulated and Above 35 sq. mm to upto 95 sq. mm PVC sheathed / XLPE power cable of 1.1 KV grade in the existing masonry open trench/duct/hume pipe/cable tray/surface including calmp, saddle and etc..
Laying of one number PVC insulated and Upto 35 sq. mm PVC sheathed / XLPE power cable of 1.1 KV grade in the existing masonry open trench/duct/hume pipe/cable tray/surface including calmp, saddle and etc.
Supply and Making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3C X 300 sq.mm. (11kV earthed) / (11kV unearthed) XLPE aluminium conductor cable of both 11/11 KV and 11/6.6KV grade as required :
Supply of straight through cable joint using outdoor heat shrinkable cable jointing kit complete with all accessories & including ferrules suitable for 3C x 300sqmm 11kV XLPE aluminium conductor cable as required.
Making straight through cable joint using outdoor heat shrinkable cable jointing kit supplied with all accessories suitable for 3C x 300sqmm 11kV XLPE aluminium conductor cable as required.
Supplying and providing the 24 Core x 2.5 Sqmm Cable (PVC) end terminationa\s with copper lugs for all the above cables with Double compression brass cable glands, taping, crimping, gland and amour earthing, etc. complete as required.
Supplying and providing the 12 Core x 2.5 Sqmm Cable (PVC) end terminationa\s with copper lugs for all the above cables with Double compression brass cable glands, taping, crimping, gland and amour earthing, etc. complete as required.
Supplying and providing the 2 Core x 2.5 Sqmm Cable (PVC) end terminationa\s with copper lugs for all the above cables with Double compression brass cable glands, taping, crimping, gland and amour earthing, etc. complete as required.
Supplying and making3.5X25 sqmm(28mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X35 sqmm(32mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X50 sqmm(35mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X70 sqmm(38mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X95 sqmm(45mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X120 sqmm(45mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X150 sqmm(50mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X185 sqmm(57mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X240 sqmm(62mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 3.5X400 sqmm(82mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 4X10 sqmm(25mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 4X16 sqmm(28mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 4X25 sqmm(28mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 4X35 sqmm(32mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Supplying and making 4X50 sqmm(35mm) end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV cable as required.
Fabrication and Supply of 150 mm width X 50 mm depth X 1.6 mm thickness perforated Hot Dipped Galvanised Iron cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Installaing of 150 mm width X 50 mm depth X 1.6 mm thickness THICK perforated Hot Dipped Galvanised Iron cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Fabrication and Supply of 300 mm width X 50 mm depth X 1.6 mm thicknessperforated Hot Dipped Galvanised Iron cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Installaing of 300 mm width X 50 mm depth X 1.6 mm thickness perforated Hot Dipped Galvanised Iron cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Fabrication and Supply of 150 mm width X 50 mm depth X 1.6 mm thickness THICK Perforated Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Installaing of 150 mm width X 50 mm depth X 1.6 mm thickness THICK perforated Hot Dipped Galvanised Iron cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Fabrication and Supply of 300mm x 50mm Ladder type - Hot Dip Galvanised Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Installaing of 300mm x 50mm Ladder type - Hot Dip Galvanised Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Fabrication and Supply of 600mm x 75mm Ladder type - Hot Dip Galvanised Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Installaing of 600mm x 75mm Ladder type - Hot Dip Galvanised Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Fabrication and Supply of 1000mm x 75mm Ladder type - Hot Dip Galvanised Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Installaing of 1000mm x 75mm Ladder type - Hot Dip Galvanised Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required.
Supply and Fabrication and installation of MS items such as Tees/ angles/ channels/chequered plates etc on floor/ ceiling/ wall including necessary civil work such a s grouting, finishing etc. and painting with two coats of primer and two coats of enamel paint as required.
Supply of 20mm dia medium duty ISI marked PVC conduit including all accessories like bends, junction boxes, couplers, saddles screws etc ,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit as required complete as detailed in technical specification.
Laying of 20mm dia medium duty ISI marked PVC conduit including all accessories like bends, junction boxes, couplers, saddles screws etc ,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit as required complete as detailed in technical specification.
Supply of 25mm dia medium duty ISI marked PVC conduit including all accessories like bends, junction boxes, couplers, saddles screws etc ,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit as required complete as detailed in technical specification. as detailed in technical specification.
Laying of 25mm dia medium duty ISI marked PVC conduit including all accessories like bends, junction boxes, couplers, saddles screws etc ,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit as required complete as detailed in technical specification. as detailed in technical specification.
Supply of 32mm dia medium duty ISI marked PVC conduit including all accessories like bends, junction boxes, couplers, saddles screws etc ,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit as required complete as detailed in technical specification. as detailed in technical specification.
Laying of 32mm dia medium duty ISI marked PVC conduit including all accessories like bends, junction boxes, couplers, saddles screws etc ,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit as required complete as detailed in technical specification. as detailed in technical specification.
Supply of 20mm dia corrugated good quality flexible PVC conduit along with adaptors and all other accessories as required complete.
Laying of 20mm dia corrugated good quality flexible PVC conduit along with adaptors and all other accessories as required complete.
Supply of 22mm ISI marked casing and capping including all accessories like elbows, tees, junction boxes screws etc in surface as required complete.
Laying of 22mm ISI marked casing and capping including all accessories like elbows, tees, junction boxes screws etc in surface as required complete.
Supply of 25mm ISI marked casing and capping including all accessories like elbows, tees, junction boxes screws etc in surface as required complete.
Laying of 25mm ISI marked casing and capping including all accessories like elbows, tees, junction boxes screws etc in surface as required complete.
Supply of 1.5sqmm FRLSH single core PVC insulated multistranded copper wire in existing conduit as detailed in technical specification.
Drawing of 1.5sqmm FRLSH single core PVC insulated multistranded copper wire in existing conduit as detailed in technical specification.
Supply of of 2.5sqmm FRLSH single core PVC insulated multistranded copper wire in existing conduit as detailed in technical specification.
Drawing of 2.5sqmm FRLSH single core PVC insulated multistranded copper wire in existing conduit as detailed in technical specification.
Supply of 4 sqmm FRLSH single core PVC insulated multistranded copper wire in existing conduit as detailed in technical specification.
Drawing of 4 sqmm FRLSH single core PVC insulated multistranded copper wire in existing conduit as detailed in technical specification.
Supply of 6 sqmm FRLSH single core PVC insulated multistranded copper wire in existing conduit as detailed in technical specification.
Drawing of of 6 sqmm FRLSH single core PVC insulated multistranded copper wire in existing conduit as detailed in technical specification.
Supply of 3C 1.5 sq. mm. FRLSH PVC insulated copper conductor stranded cable in existing conduit
Drawing of 3C 1.5 sq. mm. FRLSH PVC insulated copper conductor stranded cable in existing conduit
Supply of 6A modular type one way switch with suitable front plate & metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Fixing 6A modular type one way switch with suitable front plate & metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Supply of 6A modular type two way switch with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Fixing of 6A modular type two way switch with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Supply of 6A modular type, 5pin plug socket with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Fixing of 6A modular type, 5pin plug socket with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Supply of 16A modular type one way switch with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Fixing of 16A modular type one way switch with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Supply of 16A modular type ,5pin plug socket with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Fixing of 16A modular type ,5pin plug socket with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required, making good the surface etc. as required complete.
Supply of multistandard socket with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required , making good the surface etc. as required complete.
Fixing of multistandard socket with suitable front plate &metal box on surface or in recess including inter connections cutting the wall if required , making good the surface etc. as required complete.
Supply of surface or recess mounted type 15A SP weatherproof one way switch with IP66 enclosure including inter connections cutting the wall if required, making good the surface etc. as required complete.
Fixing of surface or recess mounted type 15A SP weatherproof one way switch with IP66 enclosure including inter connections cutting the wall if required, making good the surface etc. as required complete.
Supply of blanking plate in existing switch box as required complete.
Fixing of blanking plate in existing switch box as required complete.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Weather Proof Junction Boxes Supply, Installation, Testing and Commissioning IP 65 EnyCase DK Thermoplastic Cable Junction Boxes(88mm x 88mm x 53mm) with terminal Blocks suitable for the termination of 3Cx2.5 Sqmm Ar./Un.Ar. Cable, Sealing device & all necessary fixing Accesorries, mounting on 150mm Ht. with 25mmx25mmx3mm angle above the Ground level. Cost should include for supproting from ground level with supply and fixing of 20X3mm angle with 2 coats of anti rusting primer & epoxy enamel paint.
Providing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TP MCCB
Installation, testing and commissioning of 100 A, 16 KA,TP MCCB in existing panel
Supplying following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Installation, testing and commissioning of og single pole and neutral, sheet steel, MCB distribution board -12way double door
Supplying following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way , Double door
Installation, testing and commissioning of og single pole and neutral, sheet steel, MCB distribution board-16way double door
Supplying following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Installation, testing and commissioning of TPN 4 way (4 + 12), Double door DBs complete with interconnections etc. as required.
Supplying following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Installation, testing and commissioning of TPN 6 way (4 + 18), Double door complete with interconnections etc. as required.
Supplying following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Installation, testing and commissioning of TPN 8 way (4 + 24), Double door complete with interconnections etc. as required.
Supplying of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Installation, testing and commissioning of VTPN 4way (4 + 12), Double door DBs complete with interconnections etc. as required.
Supplying of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Installation, testing and commissioning of VTPN 8 way (4 + 24)DB with interconnections etc. as required.
Supplying of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
Installation, testing and commissioning of VTPN 12 way (4 + 24), DB with interconnections etc. as required.
Supplying 5 A to 32 A rating, Single pole, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 5 A to 32 A rating, Double pole, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 5 A to 32 A rating, Triple pole, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 5 A to 32 A rating, Triple pole and Neutral, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Installation, testing and commissioning of 5 A to 32 A rating SP/DP/TP/TPN complete with interconnections etc. as required.
Supplying single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying 40A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 63A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 40A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 63A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 25A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 40A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 25A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 40A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying 63A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Installation, testing and commissioning of 40-63A DP/4P MCB/RCCB complete with interconnections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
ITC of 20amps, 240 volts industrial type, socket outlet, interlocked switched sockets and surface mounting box IP 44 socket outlet, alongwith 20 amps #C” curve, TP, MCB, on surface or in recess, interconnections, steel fasteners etc complete with all other accessories including MS supports or cutting the wall if required ,finishing ,making good the same etc complete.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Installation, testing and commissioning of 20/30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, with enclosure box
Providing & Fixing MV Danger notice Plate of 200x150mm made of mild steel, at least 2mm thick & vitreous enameled white on borh sides, and with inscription in single Red color on front side as required.
Supplying of Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
Supplying of Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 10 way, Double door SPN MCBDB
Supplying of Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCBDB
Supplying of Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 4 way, Double door TPN MCBDB
Supplying of Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB
Supplying of Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
Installation, testing and commissioning of of cable end box
Supply, installation, testing and commissioning of Earthing with G.I. earth pipe 4.5 metre long,50 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supply, installation, testing and commissioning of Earthing with cast Iron earth plate 1200 mm X 1200 mm X 10 mm thick including all accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2 metre long etc. with charcoal/ coke and salt as required.
Supply, installation, testing and commissioning of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and laying following sizes of 25mmx3mm Copper Earth strips with PVC Sleeves including supply of fixing clamps and accessories when laid inside the building and inclusive of excavation & refilling of earth when laid outside the building and interconnections with earth pit and equipment, terminations/ interconnections in an approved manner as per IS:3043 (with latest amendments) inclusive of supply of all hardwares complete as required.GI conductor joints shall be bolted and joints shall be protected with bitumen paint.Copper conductor joint shall be brazed or rivetted .The equipment connection shall be bolted using galvanized hardware or bolted by using passivated hardware.
Supply and laying following sizes of 75mmx10mm GI strips including supply of fixing clamps and accessories when laid inside the building and inclusive of excavation & refilling of earth when laid outside the building and interconnections with earth pit and equipment, terminations/ interconnections in an approved manner as per IS:3043 (with latest amendments) inclusive of supply of all hardwares complete as required.GI conductor joints shall be bolted and joints shall be protected with bitumen paint.Copper conductor joint shall be brazed or rivetted .The equipment connection shall be bolted using galvanized hardware or bolted by using passivated hardware.
Supply and laying following sizes of 50mmx6mm GI strips including supply of fixing clamps and accessories when laid inside the building and inclusive of excavation & refilling of earth when laid outside the building and interconnections with earth pit and equipment, terminations/ interconnections in an approved manner as per IS:3043 (with latest amendments) inclusive of supply of all hardwares complete as required.GI conductor joints shall be bolted and joints shall be protected with bitumen paint.Copper conductor joint shall be brazed or rivetted .The equipment connection shall be bolted using galvanized hardware or bolted by using passivated hardware.
Supply and laying following sizes of 40 mmx6mm GI strips including supply of fixing clamps and accessories when laid inside the building and inclusive of excavation & refilling of earth when laid outside the building and interconnections with earth pit and equipment, terminations/ interconnections in an approved manner as per IS:3043 (with latest amendments) inclusive of supply of all hardwares complete as required.GI conductor joints shall be bolted and joints shall be protected with bitumen paint.Copper conductor joint shall be brazed or rivetted .The equipment connection shall be bolted using galvanized hardware or bolted by using passivated hardware.
Supply and laying following sizes of 25mmx6mm GI strips including supply of fixing clamps and accessories when laid inside the building and inclusive of excavation & refilling of earth when laid outside the building and interconnections with earth pit and equipment, terminations/ interconnections in an approved manner as per IS:3043 (with latest amendments) inclusive of supply of all hardwares complete as required.GI conductor joints shall be bolted and joints shall be protected with bitumen paint.Copper conductor joint shall be brazed or rivetted .The equipment connection shall be bolted using galvanized hardware or bolted by using passivated hardware.
Supply and laying following sizes of 25mmx3mm GI strips including supply of fixing clamps and accessories when laid inside the building and inclusive of excavation & refilling of earth when laid outside the building and interconnections with earth pit and equipment, terminations/ interconnections in an approved manner as per IS:3043 (with latest amendments) inclusive of supply of all hardwares complete as required.GI conductor joints shall be bolted and joints shall be protected with bitumen paint.Copper conductor joint shall be brazed or rivetted .The equipment connection shall be bolted using galvanized hardware or bolted by using passivated hardware.
Supply and installation 50 x 6 mm copper Earth busbar - 0.5 mtr long with necessary insulator supports with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply and installation 50 x 6 mm GI Earth busbar - 0.5 mtr long with necessary insulator supports with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply, laying & Terminating of following 1.1kV grade, copper conductor, PVC insulated, unarmoured, power cables. The cables shall be laid on tray / hume pipe /in ready made trenches, with nylon cable ties at every 0.5-0.75 mtr etc., as required. Rate quoted shall exclude cost of tray / hume pipe 1 Core x 6Sq. mm including Terminations
Supply and laying following sizes of GI/Copper Wire/strips including supply of fixing clamps and accessories when laid inside the building and inclusive of excavation & refilling of earth when laid outside the building and interconnections with earth pit and equipment, terminations/ interconnections in an approved manner as per IS:3043 (with latest amendments) inclusive of supply of all hardwares complete as required.GI conductor joints shall be bolted and joints shall be protected with bitumen paint.Copper conductor joint shall be brazed or rivetted .The equipment connection shall be bolted using galvanized hardware or bolted by using passivated hardware. 8 SWG GI Wire
UPS SYSTEM & CONNECTED WORKS Supply, fixing, Testing and commissioning of the following UPS System and connected works with all necessary accessories complete as required at site and as per standards. 1no. Micro Processor Based IGBT Controlled 2 x 25 KVA (or above)UPS input supply of 415 Volts + 15%, 3 Phase, 50 Hz ± 10% and an out put of 415 Volts ±1%, 3 Phase 50 ± 0.1 Hz, Input Power Factor <=0.99, Input Total Harmonic Distortion (THDi) <3%, Unity Output Power Factor @ 45deg C consisting of Rectifier, Inverter, Battery DC Circuit Breaker with necessary MS closed enclosure, Inbuilt Static BY PASS Panel (Input & output switches and Auto Static & Manual Bypass Switches), Inbuilt Copper Wounded K13 Dyn 11 Isolation Transformer @ Output side, provision for parallel integration necessary cable alley shall be provided if cable entry/exit for UPS unit is from bottom/sides and necessary hardware & software for BMS Intergration with communication port RS 485 ( Status Monitoring ), complete as required) with necessary adequate size of copper lugs etc., with necessary base channels/supports complete as required and all other necessary accessories required as per detailed specification. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply, Installation, Testing and Commissioning of 12V Sealed Maintenance Free Battery banks to support 25KVA UPS for 15 Minutes complete back up with intercell connectors & copper cables for I/P & O/P of UPS & Isolation Transformer, Battery Interlinks, DC Cabling from Battery to UPS, all interconnecting Copper cables (Battery bank to Battery DC Circuit breaker, Battery DC Circuit breaker to UPS, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
UPS SYSTEM & CONNECTED WORKS Supply, fixing, Testing and commissioning of the following UPS System and connected works with all necessary accessories complete as required at site and as per standards. 1no. Micro Processor Based IGBT Controlled 1 x 10 KVA UPS input supply of 415 Volts + 15%, 3 Phase, 50 Hz ± 10% and an out put of 415 Volts ±1%, 3 Phase 50 ± 0.1 Hz, Input Power Factor <=0.99, Input Total Harmonic Distortion (THDi) <3%, Unity Output Power Factor @ 45deg C consisting of Rectifier, Inverter, Battery DC Circuit Breaker with necessary MS closed enclosure, Inbuilt Static BY PASS Panel (Input & output switches and Auto Static & Manual Bypass Switches), Inbuilt Copper Wounded K13 Dyn 11 Isolation Transformer @ Output side, provision for parallel integration necessary cable alley shall be provided if cable entry/exit for UPS unit is from bottom/sides and necessary hardware & software for BMS Intergration with communication port RS 485 ( Status Monitoring ), complete as required) with necessary adequate size of copper lugs etc., with necessary base channels/supports complete as required and all other necessary accessories required as per detailed specification. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply, Installation, Testing and Commissioning of 12V Sealed Maintenance Free Battery banks to support 10KVA UPS for 15 Minutes complete back up with intercell connectors & copper cables for I/P & O/P of UPS & Isolation Transformer, Battery Interlinks, DC Cabling from Battery to UPS, all interconnecting Copper cables (Battery bank to Battery DC Circuit breaker, Battery DC Circuit breaker to UPS, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for roofing sheet with the required mounting clamps,cross connectors, expansion piece and other accessories required as per IEC 62305-3and as required complete.
Supply and Fixing of 8 mm Aluminum Round Conductor as vertical down conductor with the required mounting clamps , cross connectors, T connectors, expansion piece and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on surface as needed and as required complete.
Providing and Fixing of Test Joint, suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6kg low resistivity graphite compound) and providing masonry enclosure with heavy duty CI cover plate of 300X300 mm having locking arrangement with 5000kg load bearing capacity to ensure the safety of earthing system.
Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 11 kV. Test certificate to be provided with supply. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply and fixing of GI fire buckets with round bottom, EA comprising 4 EA.fire buckets of 9Kg capacity including supply of M.S pedestal stand with hooks suitable for holding of 4EAof fire buckets, painted with Post Office Red oil paint and letter FIRE on each bucket and filling with sand complete as required. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply of Rubber hand gloves suitable for 1.1KV. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply and providing St. John make first aid box 18SWG MS sheet duly painted as approved by Indian red cross society complete with all first aid medicines. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Providing and fixing Danger Plate Danger Plates shall be provided on HV and MV equipments. MV danger notice plate shall be 200 mm x 150 mm made of mild steel at least 2 mm thick vitreous enameled white on both sides and with the descriptions in signal red colour on front side as required. Notice plates of other suitable materials such as stainless steel, brass or such other permanent nature material shall also be accepted with the description engraved in signal red colour. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply and fixing of LAMINATED Single line diagram chart duly framed with 5mm thick glasssuitable to mount on wall. with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply & Fixing of MS sheet board of size 500mm x 300mm of 16 SWG with Entry Restricted To Authorised Persons Only near the Main entrance of the Substation. The lettering shall be Black painted on Yellow Back ground with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
2 hour fire rated fire retardant material sealing all electrical cutouts/ducts and openings made in the slab / wall / partition to take conduits / cable trays / raceways etc as required complete with all lead and Lifts and as directed by the Engineer-In-Charge of the work.
Supply and Installation of HT cable route markers including PCC bed complete with all necessary fixing accessories etc.,.
Supply and fixing of 11kV grade hand gloves IS approved.
Supply and fixing of anodised aluminum glass framed shock treatment chart.
Supply and fixing of single line diagram, schematic diagrams etc. of A0 size on sui table Aluminium sheet including lamination etc. as required complete on wall.
Supply and fixing of single line diagram, schematic diagrams etc. of A1 size on sui table Aluminium sheet including lamination etc. as required complete on wall.
Supply and fixing of fire retardant/extinguishing electrical insulated synthetic ma t of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: D OC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto dat e amendment), suitable for 11kV voltage and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive / com pound .
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supply and fabricating of MS items with two coats of primer and two coats of enamel paint such as Tees/ angles/channels etc for fixing in concrete trenches/ on floor/ ceiling/ wall and as required.
Supplying,installation,testing an d commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1output per phase) and suitable for three phase supply
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Installation, testing and commissioning of pre-wired, LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLSH PVC insulated, copper conductor, single core cable and earthing etc. a s required.
Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required comp lete including interconnections using 3 runs of 1.5 sqmm FRLSH PVC insulated stranded copper conductor as required.
Supply of 6.5-9 Meters Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector founda tion bolt4 nos fixed in RCC foundation and junction box etc. complete . The pole shall be with bracket and built in GI control box of same material with service door coated with three stage painting processThe pole shall have provisio n of connecting the earth wire including all necessary accessories as required complete. Supply of lights will be under the scope of CIAL
Installation, testing and commissioning of surface mounting octogonal street light poles 6.-9 Mtrs long with 0.5 Mtrs overhang single a rm Bracket suitable for mounting 1 No. street light fixture. along with instllation of LED street light supplied from CIAL including all necessary accessories and civil works for foundation as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly
Supply of 4.5-6Meters Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector founda tion bolt4 nos fixed in RCC foundation and junction box etc. complete . The pole shall be with bracket and built in GI control box of same material with service door coated with three stage painting processThe pole shall have provisio n of connecting the earth wire including all necessary accessories as required complete. Supply of lights will be under the scope of CIAL.
Installation, testing and commissioning of surface mounting octogonal street light poles 4.5-6 Mtrs long with 0.5 Mtrs overhang single a rm Bracket suitable for mounting 1 No. street light fixture, along with instllation of LED street light supplied from CIAL, including all necessary accessories and civil works for foundation as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly
Installation, testing and commissioning of LED Street Lighting luminaire of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage less than 45 W. The Light fitting shall be with all required accessories suitable for m ounting in (48-60)mm OD pole arm.
Conducting Horizontal Directional drilling and reaming it to adequate diameter required for housing 160mm PLB HDPE pipes / ducts at road crossing and laying of the ducts in the opening thus made. The rate should include the welding charges of HDPE ducts and also the cost for back filling the pit made at the starting and ending points.
Supply of 160MM PN8 PE 80 DN 160 grade suitable for laying as road crossing ducts by Horizontal directional Drilling method in complete as required.
Conducting Horizontal Directional drilling and reaming it to adequate diameter required for housing 350mm PLB HDPE pipes / ducts at road crossing and laying of the ducts in the opening thus made. The rate should include the welding charges of HDPE ducts and also the cost for back filling the pit made at the starting and ending points.
Supply of 350MM PN8 PE 80 DN 350 grade suitable for laying as road crossing ducts by Horizontal directional Drilling method in complete as required.
ELV WORKS CCTV IP DOME CAMERAS Up to 2 megapixel (1920 × 1080) resolution Standard video compression with high compression ratio Progressive scan CMOS, capture motion video without incised margin Support dual stream, and the sub-stream for mobile surveillance High-performance and long service life Infrared LED, Approx. 20 to 30 meters IR range IR cut filter with auto switch PoE (Power over Ethernet) Ingress Protection level: IP66 Electronic shutter for different surveillance environments Other functions: alarm, reset button, mirror, and including of all mounting acessories,etc.
IP BULLET Up to 2 megapixel (1920 × 1080) resolution Standard video compression with high compression ratio Progressive scan CMOS, capture motion video without incised margin Support dual stream, and the sub-stream for mobile surveillance High-performance and long service life Infrared LED, Approx. 20 to 30 meters IR range IR cut filter with auto switch PoE (Power over Ethernet) Ingress Protection level: IP66 Electronic shutter for different surveillance environments Other functions: alarm, reset button, mirror, and including of all mounting acessories,etc.
Supply, Installation, Testing and commissioning of 32CHANNEL NVR,HDMI,BNC&VGA output, RAID5 configurable, Hot Swap, Digital Zoom, 3USB Ports, 4SATA, Dual Gigabit Network Ports, Redundant Power Supply, Electronic Image Stabilizer, 32Alarm Inputs & 4 Alarm Outputs, ONVIF, HDD to be calculated for FULLHD-25FPS-Continous Recording - 30days, HDD calculation to be shared along with datasheet. The rate shall include Minimum 5 User License and with Web Based Software, Mobile App for Android & Apple. NVR should be Rack Mountable ( 1 x 64TB Combination ).
Supply, installation, testing and commissioning of 24 ports Stackable Edge POE L2 managed Switch for CCTV including accessories & necessary arrangements with redundant power supply.
Supply & Fixing of 12U Rack,550x550 Rack/Welded With necessary accessories (2PDU, 3 Shelves, perforated Cable Manager 2 & 4Fans)
Supply & Fixing of 42U rack with glass door in front side. The rack shall be provided with suitable power sockets/strips, lock and key, cable manager etc
Supply & Installation of 32" LED Professional Display with LAN port / all mounting bracket, connection card wire, remote control etc as per the specification. The braket shall be provided with adjustable type from wall for better servicibility.
Supply & Laying O. F.Cable 06F Outdoor - un-Armoured Unitube SM - HDPE Sheath
Supply & installation of HDMI over IP with POE Transmittor and receiver( cat6 to HDMI Coverter)
High-definition(1000dpi) optical 3button USB wired mouse with 1.5mtr length/unit.
15Pin 256kB/Sec, 1080p resoultion HDMI cable with a 10mtr length/ 1unit.
TELEPHONE/TV SYSTEM Supply and laying of outdoor multiplier 0.51mm dia annealed copper conductor of armoured PVC insulated and jelly filled telephone wires in the exsisting pipe/conduits etc., all complete as required-200 Pair cable
Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination-200 Pair
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper condutor,unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required-2 Pair
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper condutor,unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required-4 Pair
IP – EPABX configured for: Analogue Extensions: 200, expanadle Digital Extensions:8,PRI-4,Operator Console – 24 Keys- 1 No- with -60 DSS Keys.
50 Port Voice Panel 4 Nos
termination of Jack Panel 50 port 8 Nos
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required-Telephone socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required-TV antenna socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required-Telephone socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required-TV antenna socket outlet
Supplying and drawing RG-6 cable,- PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existing surface or recessed conduit/casing capping including making connections as required
Supplying and drawing RG-11 cable, PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existing surface or recessed conduit/casing capping including making connections as required
Supply and Installation of 8-way splitters in die cast Al.casing
Network System Supplying & drawing UTP-CAT 6E LAN cable
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 RJ45/ I.O.outlet Cat-6
Supplying & Fixing of switch mounting rack with power manager&cable manager 6U with 650mm depth
Supplying & Fixing of switch mounting rack with power manager&cable manager 9U with 650mm depth
Supplying & Fixing of switch mounting rack with power manager&cable manager 12U with 650mm depth
Supplying & fixing of Network switches 48Port Gogabyte(manageable)
Supplying & fixing of Network switches 24Port Gogabyte(manageable)
Supplying & fixing of Network switches 10Port Gogabyte(manageable)
Supplying & fixing of I/O socket with back box Single I/O
Supplying & fixing of I/O socket with back box Double I/O
Supplying & fixing of Cat6 Patch cable 1mtr
Supplying & fixing of patch panel for LAN cabling 48 Port 10/100/1000 patch panel
Supplying & fixing of patch panel for LAN cabling 24 Port 10/100/1000 patch panel
Supplying & fixing of patch panel for LAN cabling 16Port 10/100/1000 patch panel
Supply, Installation,Testing and Commissioning of Wireless Access Points as per technical specifications
Description of Work / Item(s)
Amount
PHE SERVICE WORKS Supplying, Fixing, testing & commissioning of approved make white glazed European water closet wall mounted type with concealed cistern. The quoted price shall also include all internal parts of the cistern with white colour plastic solid seat and cover with rubber buffers and flap, heavy duty plastic hinges, CP brass wall plate complete and as directed by the engineer incharge. including 110mm dia WC connector, SS304 extension bolts & silicone sealant, complete and as directed by the engineer incharge. .(For all toilets) basic price of Wall Mounted EWC -Rs. 15000 /- ,Concealed Cistern 8 cm thickness, Flow pressure - 0.1-10 bar, Maximum operating temperature, water - 25 °C, Flush volume - 6 and 3 L. - Rs. 4500 /- , Mat Finish Plastic Flush plate, Actuation force - < 20 N - Rs. 1200 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make physically handicapped toilet set consisting of floor mounted EWC with seat cover, wall hung washbasin, single lever clinical faucet, wall mounted grab bar, hinged hand rail, bottle trap, waste coupling & paper holder. The quoted price shall also include 1no. 15mm CP brass angle cock,CP brass Inlet connection pipe, CP brass wall flange, all internal parts of the cistern black colour plastic solid seat and cover with rubber buffers and flap, heavy duty plastic hinges, complete and as directed by the engineer incharge. including 110mm dia WC connector & silicone sealant.complete and as directed by the engineer incharge. and as directed by the engineer incharge. ( For Physically Challenged Toilet ).basic rate of Differently Abled floor mounted one piece EWC with flush Tank & Soft Seat Cover suitable - Rs. 8154 /-, Wall Hung Clinical Wash basin - Rs. 7500 /-, Chrome Plating Clinical single lever faucet with 200 mm lever - Rs. 2500 /-, Wall Mounted SS with anti slip coating Grab Bar - 3 Nos. - Rs. 7050 /-, U Shaped Wall mounted rail (with hinge) 600 x 100mm - 1 No. - Bars made from SS with anti slip coating - Rs. 8000 /-, U ShapedWall mounted rail (without hinge) 600 x 100 mm - 1 No. - Bars made from SS with anti slip coating - Rs.5000 /-, CP Bottle Trap - 1 No. - Rs.1200 /-, Waste Coupling - 1 No. - Rs.450 /-, CP Angle Cock - 2 Nos. - Rs.1050 /-, CP Toilet Roll Holder - 1 No. - Rs.1200 /-, SS304 extension bolts etc. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make white glazed oval wash basin white colour below counter 15mm Long body C.P. pillar wall mounted sensor based Cock, 32mm dia CP waste coupling, 32mm dia C.P.bottle trap with C.P. extension pipe,C.P.spreader unit GI expansion bolts, supporting bracket with necessary steel to support basin 1 No.15mm CP angle valve with 450mm long CP connection pipe, Silicone Sealant and CP wall flanges all of approved make etc.,complete and as directed by the engineer incharge...basic rate of Below Counter Oval Washbasin - Rs. 4500 /-, CP Pillar Cock wall mounted with Sensor based - Rs.12000 /-, CP Bottle Trap - Rs. 900 /-, CP Angle Cock - Rs. 900 /-, CP Waste Coupling - Rs. 600 /-, SS304 Extension Bolts etc. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make white colored large flat back sensor based urinals with 40mm C.P. dome type waste coupling 40mmC.P. bottle trap with C.P. extension pipe, etc., C.P.spreader unit GI expansion bolts etc., complete and as directed by the engineer incharge...( Bottle trap & waste coupling contractor to be check with model while installing.), basic rate of Sensor Based Urinals - Rs. 21000 /-, Bottle Trap - Rs. 900 /-, Waste Coupling - Rs. 900 /-, SS304 Extension Bolts etc. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make 15mm CP health faucet of approved make with necessary CP flexible hose 1000mm long nozzle,CP wall flange, CP angle cock etc., complete and as directed by the engineer incharge. base rate of CP Heavy Duty Health Faucet - Rs.2100 /-, angle valve - Rs.1050 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make 15mm CP long body bib cock with CP flanges including necessary fixing materials etc.,complete and as directed by the engineer incharge.basic rate of CP Long body Bib Cock - Rs.1350 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make 15 mm dia CP angle cocks for water purifier provision in each floor etc complete and as directed by the engineer incharge. .basic rate of CP Angle Cock - Rs. 900 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make Push ABS liquid Soap dispenser of 1000ml of capacity of approved make with necessary fixing materials etc.complete and as directed by the engineer incharge. basic rate of Liquid Soap Dispenser - Rs.3000 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, fixing, testing and commissioning of approved make Recessed Electric Hand Drier twin blower integrated with timer (0-3 minutes) and infrared arrangement complete and as directed by the engineer incharge. .. The drier shall be fully automatic.basic rate of Wall Flushed Electric Hand Drier - Rs.12000 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make SS body Recessed Paper Towel Dispenser with necessary screws, Clamps etc complete and as directed by the engineer incharge. and as directed by the engineer incharge.., .basic rate of Paper Towel Dispenser - Rs. 4500 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make Water cooler comprising with necessary accessories including suitable extension pipe etc complete and as directed by the engineer incharge.… for drinking water point area.Body. - SS 304, Unit Dim (WxDxH) in mm - 550x525x1450, Pre-Filter + Pre Carbon + Post Filteration + UV - Yes, No. of Faucets - 3 (N+C+H)**, Storage Tank Capacity - 80 Lts, Hot Water - 5 Lts, Cold Water - 40 Lts, Normal Water - 35 Lts, basic rate of despenser Rs.65000 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of sink with single bowl and single drain board manufactured from 1.2mm thick stainless steel 304, 18G high grade indestructible chrome nickel steel with top quality polish,1no.40mmdia CP waste coupling, with 1no. 40mm dia CP bottle trap with extension pipe, Sink Cock with wall flange with aerator, SS304 Extension Bolts etc., complete and as directed by the engineer incharge. . Size of sink : 1150mm x 500mm. ( For Kitchen),basic rate of Sink Overall Size 40 x 18.5 / 1020 x 465 (inch/mm) Bowl Size 18 x 15 x 8 / 460 x 380 x 200 (inch/mm) Finish Type Available Glossy | Matt Thickness 1 mm - Rs.7000 /-, Sink Cock - Rs.2200 /-, Waste Coupling - Rs. 450 /-, Bottle Trap - Rs. 900 /-, Angle Cock - Rs. 900 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, installing, testing and commissioning of approved make CI hose pipe connection nipple/connector, Stainless Steel Hose Pipe Clamp,GM PN12 25mm dia ball valve with necessary accessories etc complete and as directed by the engineer incharge.for irrigationwater system. basic rate of ball valve - Rs. 450 /-, hose pipe - Rs. 100 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of CP twin coat hook fixed with SS screws on to the toilet door complete and as directed by the engineer incharge. and as directed by the engineer incharge.basic rate of twin coat - Rs.1200 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of CP paper holder fixed with SS screws on to the toilet door complete and as directed by the engineer incharge..basic rate of - papr holder - Rs. 1200 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supply, Installation, Testing and Commissioning of mineral filled 3 layered (PP/PP mineral filled/PP) Polypropylene low noise pipes and fittings of min. density 1.9 gm/cm3, pipes of 40 mm – 200 mm including all fittings & accessories such as coupler, elbow, tee, Y, reducer, access door, end cap, cowls, etc. for soil, waste and vent purpose in floors, ceiling suspended, or on walls, with leak proof joints etc. Joining pipes & fittings with rubber sealing rings as per approved manufacturer recommendation. Wall chasing, holes, supporting, clamping, covering back with chicken mesh & plaster and making the wall good as per approved shop drawing. Sound level of less than 20 dB(A) at flow rate of 4 L/s according to DIN 4109. complete and as directed by the engineer incharge. - Should have D-s2, d0 fire classification as per EN 13501 or B2 as per DIN 4102, short term hot water resistance upto 95°c and long term upto 90°c, chemical resistance of pH 2 to pH12 - Should have IAPMO and Green certification - 75 mm Outer dia ( inside the toilet till shaft ) (6kg/cm2)
Supply, Installation, Testing and Commissioning of mineral filled 3 layered (PP/PP mineral filled/PP) Polypropylene low noise pipes and fittings of min. density 1.9 gm/cm3, pipes of 40 mm – 200 mm including all fittings & accessories such as coupler, elbow, tee, Y, reducer, access door, end cap, cowls, etc. for soil, waste and vent purpose in floors, ceiling suspended, or on walls, with leak proof joints etc. Joining pipes & fittings with rubber sealing rings as per approved manufacturer recommendation. Wall chasing, holes, supporting, clamping, covering back with chicken mesh & plaster and making the wall good as per approved shop drawing. Sound level of less than 20 dB(A) at flow rate of 4 L/s according to DIN 4109. complete and as directed by the engineer incharge. - Should have D-s2, d0 fire classification as per EN 13501 or B2 as per DIN 4102, short term hot water resistance upto 95°c and long term upto 90°c, chemical resistance of pH 2 to pH12 - Should have IAPMO and Green certification - 110 mm Outer dia ( inside the toilet till shaft ) (6kg/cm2)
Supplying and fixing of approved make parapet drain for balcony area complete and as directed by the engineer incharge. as shown in the drawing. Type: wall Drain, material of body PE.size as per the list of approved make.
Supplying, Fixing, testing & commissioning of approved make roof drain for Terrace area complete and as directed by the engineer incharge. as shown in the drawing.100mm outlet, aluminium grating with CI drain body. Sizes of the drain as per manufactures.
Supplying, Fixing, testing & commissioning of approved make 110mmx110mm dia low noice 3 layer 'P' trap with bose pipe arrangements & and slotted type floor grating bronze chrome plated ring and grate with two SS screw with necessary pipe support fixed below or above slab with GI suspenders complete and as directed by the engineer incharge. ( For EWC & Washbasin Area, basic price of Cockroach Trap - Rs. 1300 /-, Grating : 125x125mm with slotted type. NOTE: THE PVC EXTENTION PIPE FOR TOILET FLOOR TRAPS EXTENSION PIPE LENGTH SHOULD BE 150MM ABOVE THE SUNKEN SLAB & 500MM FROM BOTTOM OF THE SLAB
Supplying, Fixing, testing & commissioning of approved make 110mmx110mm dia low noice 3 layer PE 'P' trap with bose pipe arrangements & and slotted type floor grating bronze chrome plated ring and grate with two SS screw with necessary pipe support fixed below or above slab with GI suspenders complete and as directed by the engineer incharge. ( For Urinals area) basic price of Cockroach Trap - Rs. 1300 /-. Grating : 125x125mm with solid cover. NOTE: THE PVC EXTENTION PIPE FOR TOILET FLOOR TRAPS EXTENSION PIPE LENGTH SHOULD BE 150MM ABOVE THE SUNKEN SLAB & 500MM FROM BOTTOM OF THE SLAB
Supplying, Fixing, testing & commissioning of approved make Deep Seal ( 5") UPVC multi-inlet with minimum 50mm water seal floor trap with 75 mm dia outlet with and slotted type floor grating bronze chrome plated ring and grate with two SS screw with necessary pipe support fixed below or above slab with GI suspenders complete and as directed by the engineer incharge. ( For pantry area)basic price of Cockroach Trap - Rs.1300 /- Grating : 125x125mm with slotted type NOTE: THE PVC EXTENTION PIPE FOR KITCHEN FLOOR TRAPS EXTENSION PIPE LENGTH SHOULD BE 150MM ABOVE THE SUNKEN SLAB.
Supplying, Fixing, testing & commissioning of approved make 75mm dia PVC bend with 90mmx90mm CP grating (frame arrangements with screwed removable type) with necessary fixing materials and cement concrete around the trap for collection of EWC areacomplete and as directed by the engineer incharge..Basic price of grating - Rs. 650 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make 75mm dia PVC bend with 101mmx101mm CP grating (frame arrangements with screwed removable type) with necessary fixing materials and cement concrete around the trap for collection of rain water complete and as directed by the engineer incharge..Basic price of grating - Rs. 650 /-. The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing.
Supplying, Fixing, testing & commissioning of approved make floor drain with 100mm dia CI 'P' trap with floor grating of 125x125 SS slotted type grating., bronze chrome plated ring and grate with two SS screw etc., complete and as directed by the engineer incharge..
Supplying, fixing & testing inlet, outlet & pipes & fittings to storm water collection sump with steps & FRP frame and Gylly cover as shown on the drawings etc., complete and as directed by the engineer incharge. with accessories comprising of the following. Approximate detph. - 2.50 M2nos. 100mm dia GI hot dip galvanized vent pipe with mosquito proof mesh complete as directed by the Engineer in charge
Supplying, fixing & testing inlet, outlet & pipes & fittings to storm water collection sump with steps & FRP frame and Gully cover as shown on the drawings etc., complete and as directed by the engineer incharge. with accessories comprising of the following. Approximate detph. - 2.50 M2 -2 Nos 600 x 600 FRP 20T Manhole frame and gully cover for efficient maintenance of the tanks etc.,complete and as directed by the engineer incharge..
Supplying, fixing & testing inlet, outlet & pipes & fittings to storm water collection sump with steps & FRP frame and Gylly cover as shown on the drawings etc., complete and as directed by the engineer incharge. with accessories comprising of the following. Approximate detph. - 2.50 M - 1 No. 63 mm dia GI hot dip galvanized puddle flange outlet pipe for Basement & rain water collection sumps .
Supplying, fixing & testing inlet, outlet & pipes & fittings to storm water collection sump with steps & FRP frame and Gylly cover as shown on the drawings etc., complete and as directed by the engineer incharge. with accessories comprising of the following. Approximate detph. - 2.50 M - 2 Nos.100 mm dia GI hot dip galvanized puddle flange outlet pipe for Basement & rain water collection sumps Vent pipe .
Supplying, laying, jointing, testing and commissioning approved make DWC SN8 HDPE pipes with solvent cement joints confirming to DIN standards for sewerage system & storm water system and shall include necessary fittings like Tees, Bends, Offsets etc., complete and as directed by the engineer incharge.. - 150 mm dia
Supplying, laying, jointing, testing and commissioning approved make DWC SN8 HDPE pipes with solvent cement joints confirming to DIN standards for sewerage system & storm water system and shall include necessary fittings like Tees, Bends, Offsets etc., complete and as directed by the engineer incharge.. - 200mm dia
Supplying, laying, jointing, testing and commissioning approved make DWC SN8 HDPE pipes with solvent cement joints confirming to DIN standards for sewerage system & storm water system and shall include necessary fittings like Tees, Bends, Offsets etc., complete and as directed by the engineer incharge.. - 250 mm dia
Supplying, laying, jointing, testing and commissioning approved make DWC SN8 HDPE pipes with solvent cement joints confirming to DIN standards for sewerage system & storm water system and shall include necessary fittings like Tees, Bends, Offsets etc., complete and as directed by the engineer incharge.. - 300 mm dia
Supplying, laying, jointing, testing and commissioning approved make durra coated surface grating for storm water outlets on road , complete and as directed by the engineer incharge.. As shown in the Drawing.Purchase price of grating - Rs. 1200 /- The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. DURRA COATED SURFACE GRATING ( Cast body with CI grating) SIZE: 100MM OUTLET
Supplying, Fixing, testing & commissioning of approved make 110mm dia PVC bend with 101mmx101mm CP grating (frame arrangements with screwed removable type) with necessary fixing materials and cement concrete around the trap for collection of rain water. Purchase price of grating - Rs. 650 /- The purchase prices is excluding GST and any deviation plus or minus in the purchase price will be adjusted ( paid extra or deducted ) at the time of billing. Grating :
Supplying,Conveying and laying in layers sand, jelly as per drawing and as directed by engineer incharge,including all lead and lifts - 20mm coarse aggregate
Supplying,Conveying and laying in layers sand, jelly as per drawing and as directed by engineer incharge,including all lead and lifts - 40mm coarse aggregate
Supplying,Conveying and laying in layers sand, jelly as per drawing and as directed by engineer incharge,including all lead and lifts - Sand
Supplying, Fixing, testing & commissioning of Grease separator plant as per DIN EN 1825 and DIN 4040‑100; For indoors installation – frost free; With integrated sludge trap; Operating side: right/left; Draining connection, fire hose quick coupling B 2½"; Suction and emptying sump with drain plug socket 1"; Inspection window with wiper; With two seperate pumps for internal cleaning and disposal; Automatic high-pressure internal cleaning head with pump - The pump should have Nominal pressure of 175 bar; Chopping, mixing, rinsing in one process; with only cold water requirement; Motor-driven high-pressure spray head shall have 360 degree rotatory action to achieve higher cleaning efficieny; Standard control with group fault reporting; Disposal pump with Vortex impeller; Delivery performance: 20 m³/h at 1 bar medium delivery head; Stop valve upstream of disposal pump; Odour-proof maintenance opening, diameter: 450 mm; Filling device with Solenoid valve for automatic refilling; The unit shall have Level measurement via pneumatic pressure measurement including bubbler injection; the switching between the cleaning and dispsoal shall be automatic; Connections for inlet and outflow as per DIN EN 877; Electrical connector: 400V/50Hz/16A/8.0kW System should have provision to connect volt free contacts to BMS Nominal size: NS 20
Supplying, Fixing, testing & commissioning of approved Polymer Concrete Drains with Brickslot Grating; the channel shall be made of polymer concrete with V profile; with clear width of 150mm, outer width of 185mm and overall depth of 200mm; the grating shall be made up of Stainless Steel 304 grade with slot opening of 10mm and slot at center; Grating height shall be 70mm; oveall depth of the drain (Channel+Brickslot grating) shall be 270mm; the system to be supplied with accessories like outlet channels, end caps, access units for the brickslot etc
Supplying, Fixing, testing & commissioning of approved Polymer Concrete Channel body DIN EN 1433 with boltless drainlock®, V-profile, zero water absorption, integrated edge protection in galvanised steel, with ACO DRAIN safety groove (SF), tongue and groove joints, with built-in slopes; With integrated lip labyrinth sealing for liquid-tight connection to ground line, with lateral pre-shapes for corner-, T- and cross connections, universal front wall, with edge protection; grating made up of ductile iron material as per DIN EN 1433; internal width-150mm; overall width- 185mm; overall depth - 210-260mm as per design
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 80mm dia - Equal Tee
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 80mm dia - Double socket Tee with Flanged branch
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 80mm dia - 90deg Elbow
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 80mm dia - Double socket 1/4 Bend
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 80mm dia - Double socket 1/8 Bend
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 80mm dia - Double socket Taper 80x65mm
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 100 mm dia - Equal Tee
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 100 mm dia - Double socket Tee with Flanged branch
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 100 mm dia - 90deg Elbow
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 100 mm dia - Double socket 1/4 Bend
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 100 mm dia - Double socket 1/8 Bend
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 100 mm dia - Double socket Taper 100x80mm
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 150 mm dia - Double socket Tee with Flanged branch
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 150 mm dia - Double socket Taper 150x100mm
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 150 mm dia - Double socket Taper 150x100mm Double socket 1/4 Bend
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 150 mm dia - Double socket 1/8 Bend
Supplying, installing, testing and commissioning make DI fittings confirming to BS 4772 class K12 etc., complete and as directed by the engineer incharge. 150 mm dia - 90deg Elbow
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. - 15 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. - 20 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. -25 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. - 32 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. 40 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. - 50 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. - 65 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. ( only hot water supply & return system) - 80 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes & fittings (CPVC) SDR.11, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc, with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846.above 50mm dia CPVC sch-80 pipes & Fittings confirming ASTM F441 & fittings confirming ASTM F 439. ( only hot water supply & return system) - 100 mm dia
Supplying, laying, jointing, testing and commission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint - 15 mm dia ( 9mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, laying, jointing, testing and commission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint - 20 mm dia ( 9mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, laying, jointing, testing and c ommission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint - 25 mm dia ( 9mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, laying, jointing, testing and commission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint - 32 mm dia ( 13mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, laying, jointing, testing and commission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint -40 mm dia ( 13mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, laying, jointing, testing and commission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint - 50 mm dia ( 13mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, laying, jointing, testing and commission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint - 65 mm dia ( 19mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, laying, jointing, testing and commission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint - 80mm dia ( 19mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, laying, jointing, testing and commission-ing approved make rubberized insulation with UV & water proof wrapping for hot water pipes inside the shaft , toilets & kitchen (exposed area) with fire and water resistent & 2 coats of canvas coating paint - 100mm dia ( 19mm thick rubberized insulation ) complete and as directed by the engineer incharge.
Supplying, installing, testing and commissioning approved make Forged Brass PN25 20mmdia automatic AIR RELEASE VALVE with necessary Unions etc.,complete and as directed by the engineer incharge..
Supplying, installing, testing and commissioning approved make PN16 mechanically operated butterfly valve to be fixed in the OHT. Water level controlling by mechanically operted system. complete and as directed by the engineer incharge. a) 50 mm dia
Supplying, installing, testing and commissioning approved make Forged brass ball valves PN16 , IS 1703-1977 with screwed ends, necessary unions etc., complete and as directed by the engineer incharge. - 20 mm dia
Supplying, installing, testing and commissioning approved make Forged brass ball valves PN16 , IS 1703-1977 with screwed ends, necessary unions etc., complete and as directed by the engineer incharge. -25 mm dia
Supplying, installing, testing and commissioning approved make Forged brass ball valves PN16 , IS 1703-1977 with screwed ends, necessary unions etc., complete and as directed by the engineer incharge. - 32 mm dia
Supplying, installing, testing and commissioning approved make Forged brass ball valves PN16 , IS 1703-1977 with screwed ends, necessary unions etc., complete and as directed by the engineer incharge. -40 mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves standard lever type PN12 confirming to IS 13095 with necessary flanges nuts & bolts, Noeprene rubber gaskets etc., complete and as directed by the engineer incharge. - 50 mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves standard lever type PN12 confirming to IS 13095 with necessary flanges nuts & bolts, Noeprene rubber gaskets etc., complete and as directed by the engineer incharge. -65 mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves standard lever type PN12 confirming to IS 13095 with necessary flanges nuts & bolts, Noeprene rubber gaskets etc., complete and as directed by the engineer incharge. - 80 mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves standard lever type PN12 confirming to IS 13095 with necessary flanges nuts & bolts, Noeprene rubber gaskets etc., complete and as directed by the engineer incharge. - 100 mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves standard lever type PN12 confirming to IS 13095 with necessary flanges nuts & bolts, Noeprene rubber gaskets etc., complete and as directed by the engineer incharge. - 150 mm dia
Supplying, installing, testing and commissioning approved make CI butterfly valves standard lever type PN12 confirming to IS 13095 with necessary flanges nuts & bolts, Noeprene rubber gaskets etc., complete and as directed by the engineer incharge. - 200 mm dia
Supplying, installing, testing and commissioning approved make C.I dual plate check valve slim seal PN 16, IS 5312-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 200mm dia
Supplying, installing, testing and commissioning approved make C.I dual plate check valve slim seal PN 16, IS 5312-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 150mm dia
Supplying, installing, testing and commissioning approved make C.I dual plate check valve slim seal PN 16, IS 5312-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 100mm dia
Supplying, installing, testing and commissioning approved make C.I dual plate check valve slim seal PN 16, IS 5312-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 80mm dia
Supplying, installing, testing and commissioning approved make C.I dual plate check valve slim seal PN 16, IS 5312-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 65mm dia
Supplying, installing, testing and commissioning approved make C.I dual plate check valve slim seal PN 16, IS 5312-1969 with necessary flanges, nuts, bolts & Neoprene Rubber gaskets etc., complete and as directed by the engineer incharge. confirming to API/BIS. - 50mm dia
Supplying, installing, testing and commissioning approved make ANSI PN16 Class 125/150 Cast Iron body brass 'Y' strainer ( PN16) with necessary flanges, nuts & bolts Noeprine Rubber Gaskets etc complete and as directed by the engineer incharge..,completion to the suction line - 250mm nominal dia
Supplying, installing, testing and commissioning approved make ANSI PN16 Class 125/150 Cast Iron body brass 'Y' strainer ( PN16) with necessary flanges, nuts & bolts Noeprine Rubber Gaskets etc complete and as directed by the engineer incharge. .,completion to the suction line - 200mm nominal dia
Supplying, installing, testing and commissioning approved make ANSI PN16 Class 125/150 Cast Iron body brass 'Y' strainer ( PN16) with necessary flanges, nuts & bolts Noeprine Rubber Gaskets etc complete and as directed by the engineer incharge. .,completion to the suction line - 150mm nominal dia
Supplying, installing, testing and commissioning approved make ANSI PN16 Class 125/150 Cast Iron body brass 'Y' strainer ( PN16) with necessary flanges, nuts & bolts Noeprine Rubber Gaskets etc complete and as directed by the engineer incharge. .,completion to the suction line - 100mm nominal dia
Supplying, installing, testing and commissioning approved make ANSI PN16 Class 125/150 Cast Iron body brass 'Y' strainer ( PN16) with necessary flanges, nuts & bolts Noeprine Rubber Gaskets etc complete and as directed by the engineer incharge. .,completion to the suction line - 80mm nominal dia
Supplying, installing and commissioning PN12 SS Expansion Bellows with SS braiding & MS flanges for Suction and delivery headers including all necessary supports, neoprine rubber gaskets, nuts, bolts etc., complete and as directed by the engineer incharge. - 200mm dia
Supplying, installing and commissioning PN12 SS Expansion Bellows with SS braiding & MS flanges for Suction and delivery headers including all necessary supports, neoprine rubber gaskets, nuts, bolts etc., complete and as directed by the engineer incharge. -150mm dia
Supplying, installing and commissioning PN12 SS Expansion Bellows with SS braiding & MS flanges for Suction and delivery headers including all necessary supports, neoprine rubber gaskets, nuts, bolts etc., complete and as directed by the engineer incharge. - 100mm dia
Supplying, installing and commissioning PN12 SS Expansion Bellows with SS braiding & MS flanges for Suction and delivery headers including all necessary supports, neoprine rubber gaskets, nuts, bolts etc., complete and as directed by the engineer incharge. - 80mm dia
Supplying, installing and testing of 100mm dia tanker inlet connection system near the entrance gate. This includes PN-12 100 dia 4 nos stand post, non return valve, Butterfly Valve & instantaneous brass coupler, etc.,complete and as directed by the engineer incharge.
Supplying, installing, testing and commissioning of approved make cast brass body water meter with necessary unions for fixing on the inlet main as shown on the drawing, etc., complete and as directed by the engineer incharge. with water meter chamber of 750x750x1500mm with cover and necessary gate valve,NRV, union, float valve, 600x600mm FRP 40T recess covers etc., complete and as directed by the engineer incharge..(of approved makes - digital). a) 65mm nominal dia
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - 300mm dia
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - 250mm dia
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - 200mm dia
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - 150mm dia
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - 100mm dia
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - 80mm dia
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - 65mm dia
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. -Vent pipe with mosquito proof mesh (100mm dia)
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - Vent pipe with mosquito proof mesh (150mm dia)
Supplying, installing, fixing, jointing, testing and commissioning of MS class C hot dip galvanised puddle flange complete and as directed by the engineer incharge.. - Sleeves for level controller - 50mm dia
Supplying, installing, fixing, jointing, testing and commissioning of Heavy duty pvc rungs complete and as directed by the engineer incharge - size: 165x375mm
RO Plant Supply, installation, testing and commissioning of RO plant of 2000 LPH permeate flow including the following items. 5 Micron Cartridge filter - 2 Nos RO Pressure Tube and Membrane, Number of Pressure Tubes = 4 Nos MOC of Pressure Tubes = FRP Number of Membranes = 12 Nos MOC of Membranes = TFC Polyamide Membrane Size = 4" x 40" Pressure Tube Make: Codeline / UKL Membrane Make: Toray/LG. uPVC(PN20) high pressure piping & pressure gauges as required. RO plant shall have flow indicator (rotameter) for Permeate, Reject, and pressure indicators - 1 Lot Unit shall be mounted on SS304 skid Inter connecting pipes (high Pressure uPVC, Low Pressure cPVC) with all accessories for RO pumps with necessary valves, pressure gauges, water flow meters, hydraulic hose, and other hardware items UV Sterilizer of 5000 LPH CIP 300 Ltr HDPE tank with interconnection and micron filter
CONTROL PANEL Supplying, installing, testing and commissioning of approved make Control Panel (PLC controller) to house all the necessary drives; instruments (as listed below). The panel shall include all relays; fuses; annunciation box with hooter facility. All control & power cabling to be included for the RO Plant. which will be used to operate the plant in auto mode. Instruments to be provided include flow meter 1nos, TDS meter 1 nos & pH meter 1 nos, Pressure switches and any other item to make the RO block automatic.
RO PERMEATE WATER STORAGE TANKSupplying, Supplying, installation, testing and commissioning of RO water storage tanks with inlet, outlet, over flow, drain pipe with valve. The tank shall be made of SS316 Grade material with leg supported or stand. mounted on suitable size PCC platform. Capacity - 3,000 litres with SS 316 Dia – as per Manufacturer, Height – as per Manufacturer, Tank Thickness - 2.5 mm shell & 3.0mm dished end
RO BOOSTER SYSTEM Supplying, testing and commissioning of RO water system with below mentioned duty point. The price shall include the control panel with cyclic operation and booster accessories i.e. Pr. Transmiter, Pr. Gauge, 100 L Pressure vessel. The pumps shall be mounted on base frame & Motor shall be built-in VFD & IE5 type. Duty Point: 5.0 cum/hr @ 40 mtr head 1 Set = 1working + 1standby Model: CMBE TWIN 5-62
PLUMBING, INSTALLATION AND COMMISSIONING Cost for Plumbing, installation, labour & commissioning. Plumbing, duly insulated with Nitrile Rubber between Storage tank and heat pumps in CPVC complete and as directed by the engineer incharge. with accessories, fittings, safety devises, etc. Note - 1. The location of the equipment considered on Terrace 2. The battery limit for plumbing works has been clearly indicated in schematic.
Supplying, installing, testing and commissioning approved make Raw Water Pressure sand filter with necessary Accessories complete and as directed by the engineer incharge. with Frontal piping, valves, suitable supports for mounting pressure gauges, orifice plates. The Filter shall be made of M.S with necessary protective coating. The cost of filter shall also include initial charge of under bed & multi-grade filter media to suit the requirement etc., complete and as directed by the engineer incharge. as per standards. Max. working pressure = 3.5kg/sqcm Max flow rate = 10.0 cum/hr,at 12 hrs cycle
Supplying, installing, testing and commissioning approved make Water Softener including brine tank with agitator,HDPE tank, necessary Accessories complete and as directed by the engineer incharge. with Frontal piping, valves, suitable supports for mounting pressure gauges, orifice plates. The Softener shall be made of MS with necessary protective coating. The cost of Softener shall also include initial charge of Resin media to suit the requirement etc., complete and as directed by the engineer incharge. as per standards. bypass arrangements with isolation valves to be considered. Max. working pressure = 3.5kg/sqcm Max flow rate = 10.0 cum/hr,at 12 hrs cycle Note: OBR considered = 80 Cum; Resin = 750 Ltr; Hardness = 600 PPM
Supplying, installing, testing and commissioning approved make Activated Carbon Filter with necessary Accessories complete and as directed by the engineer incharge. with Frontal piping, valves, suitable supports for mounting pressure gauges, orifice plates. The Filter shall be made of M.S with necessary protective coating inside with asphalethene black and outside with enamel coating .The cost of filter shall also include initial charge of under bed & Activated carbon filter media of GS 500 grade to suit the requirement etc., complete and as directed by the engineer incharge. as per standards. Max. working pressure = 3.5kg/sqcm Max flow rate = 10.0 cum/hr,at 12 hrs cycle
Supplying, installing, testing and commissioning inter unit uPVC SH- 80 ASTM 1785D piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc and with one coat of primer and two coats of approved enamel paint with IS recommended color etc., complete and as directed by the engineer incharge..
SEWAGE TREATMENT PALNT Design, supplying, installing, testing & commissioning of elecro-mechanical works Sewage Treatment Plant for the following design parameters: Daily average flow - 110 .0 cum/day Anticipated effluent parameters before treatment : PH - 6.5-7.5 BOD5 - 200 - 250 mg/ltr COD - 400-600 mg/ltr SS - 100-150 mg/ltr Ecoli - NIL Desired Sewage parameters after treatment : PH - 6.5-7.5 BOD5 - Less than 10 Mg/L COD - Less than 50 Mg/L Suspended Solids - Less than 10 Mg/L Ammonical Nitrogen - Less than 5 Mg/L Total Nitrogen - Less than 5 Mg/L Faecal Coliform - Less than 100 MPN/100 ml E Coli after treatment - None. Supplying, installing, testing and commissioning of BAR SCREEN 1250 x 1250 mm Size SS 304 flats of 5 mm thick 10mm space between the bars welded to a "L" angle of size 50 x 50 x5mm Thick anticorrosive treatment with hand rake.capcity ( 30.0 m3/hr ) MS/SS304 Mesh. size to be as per site condition.complete and as directed by the engineer incharge.
Supplying & installing SS fabricated 5mm thick fine screen mesh made of 5mm dia retrievable type complete as per standards.( 30.0 m3/hr ) MS/SS304 Mesh.size to be as per site condition ( 450mm wide & 300mm Height).omplete and as directed by the engineer incharge.
Supply, installation, testing & commissioning of required number of coarse bubble air diffusers 1000mm x 90mm dia in Receiving tank complete with heavy duty PVC pipe central tee, yoke, adapter and end caps.omplete and as directed by the engineer incharge.
Supply, installation, testing & commissioning of Twin lobe, roots type rotary air blowers with VFD complete with TEFC motor of suitable HP suitable for 415 + 10% volts, 3 phase, 50 cycles A/C supply, pulleys, V belt, drive guard, base frame, suction, residential silencer, dampener at discharge, Anti vibrate pads for blowers and all other accessories as required.omplete and as directed by the engineer incharge. Capacity of Each Blower: 180.0m3/hr @ 4500mm WC (1 No. Working + 1 No. stand by)
Supply, installation, testing & commissioning of required number of fine pore diffusers 1000mm x 90mm dia in SBR tank complete with heavy duty PVC pipe and EPDM membrane , central tee, yoke, adapter and end caps.complete and as directed by the engineer incharge.
Supplying, installing, testing & commissioning of online UV with a dosage > 60000 mW suitable for waste water application steriliser made of SS316L with necessary sensors, monitoring system with display panel, necessary timers, internal clocks etc., complete working on 230V single phase power supply with 98% UVT ,operating pressure of the system 3.0bars, connected in parallel.complete and as directed by the engineer incharge. Flow: 10.0 Cum/hr
Supplying, installing, testing and commissioning approved make Pressure sand filter with necessary Accessories complete with Frontal piping, valves, suitable supports for mounting pressure gauges, orifice plates. The Filter shall be made of M.S with necessary protective coating inside with asphalethene and enamel coating outside The cost of filter shall also include initial charge of underbed & multi-grade filter media to suit the requirement etc., complete as per standardscomplete and as directed by the engineer incharge.. Max. working Pressure = 3.0kg/sqcm. Max. working Pressure = 3.5kg/sqcm. Flow Rate : 15.0 cum/hr, at 8.0 Hr cycle
Supplying, installing, testing and commissioning approved make Activated Carbon Filter with necessary Accessories complete with Frontal piping, valves, suitable supports for mounting pressure gauges, orifice plates. The Filter shall be made of M.S with necessary protective coating inside with asphalethene black andoutside with enamel coating .The cost of filter shall also include initial charge of under bed & Activated carbon filter media of GS 500 grade to suit the requirement etc., complete as per standards. complete and as directed by the engineer incharge. Max. working Pressure = 3.5kg/sqcm. Flow Rate : 15.0 cum/hr, at 8.0 Hr cycle
Supplying,installing, testing and commissioning of ultra filtration system for flushing water supply only.complete and as directed by the engineer incharge. Flow Rate :5.0 cum/hr, at 8.0 Hr cycle
Supplying, installing, testing and commissioning of SS-304 bag filter type with necessary collection trays, suitable pump and poli dosing etc complete and as directed by the engineer incharge.
Supplying, installing, testing and commissioning of approved make electro - magnetic flow meter, positive displacement type with necessary electrodes, flow transmitters etc., complete for installation at sewage inlet line. The internal parts shall be made of SS316,flanged material with carbon steel, liner material-PTFE, unit shall work on 220V AC power supply. Flow meter shall be with IP 68 protection class.complete and as directed by the engineer incharge. a) 80mm dia
Providing of wooden table of 4feet length x 3feet leght x 2.5' with one set of HP suitable configuration computer, PH monitoring Kit and accessories etc,.complete and as directed by the engineer incharge.
Supplying, installing, testing and commissioning of Emergency Push Station with necessary Cable From push station to MCC panel etc complete. ( For above tank level electromechanical Equipments )complete and as directed by the engineer incharge.
Supply, installing pre-fabricated slotted Hot dip galvanized G.I Cable trays for cable works inside the pump room 150mm wide with necessary supports.complete and as directed by the engineer incharge.
Supply, installing pre-fabricated slotted Hot dip galvanized G.I Cable trays for cable works inside the pump room 300mm wide with necessary supports complete and as directed by the engineer incharge.
Providing and construction of subsoil water dewatering pit consisiting of 1.18 meter dia heavy duty precast ring and approximately 9 meter depth (depth as per drawing ) with heavy duty pvc rungs , 200mm thick bottom pcc with suction pit, stone pad, 600 x 600mm heavy duty FRP recess cover, inculding top rcc slab as per structure details, valve chamber as per the drawing.The rate shall include all labour and materials including fixing of PVC rungs, concrete works, valve chambers etc including all lead,lifts, dewatering etc complete as directed by the Engineer in charge
Supplying, Installing, Testing & Commissioning of approved make floor cleanout for subsoil drainage system with CP Brass frame & threaded solid cover including all materials labour, lead,lifts, dewatering etc complete as directed by the Engineer in charge
Description of Work / Item(s)
Amount
WATER COOLED CHILLING MACHINES Quoted price shall be inclusive of Supply, sea freight, insurance, packing and forwarding charges etc., as applicable VFD Driven Water Cooled Screw Chiller Package of cooling capacity of 150.0TR actual capacity Water Cooled Screw Chiller Package consisting of multiple nos. hermitically sealed Screw compressors (of equal capacity in independent refrigerant circuits in the case of multiple compressors) suitable with R-134a complete with suction valve, discharge valves, relief valve, crank case heaters, relays, purge & pressure relief valves & DX chiller complete with Antifreeze cooling thermostat, electronic expansion valve, chiller insulation & water coold condenser interconnecting piping, suction line insulation etc., Microprocessor control panel suitable for automatic operation incorporating all safety function as per equipment specifications & other points as listed below:Compressors continuous modulation shall be with slide valve which, depending on the position assumed, permits the compression´s chamber stepless reduction. Each compressor partializes down to 25% of its maximum capacity. In addition to standard no-load switch-on procedure, the motor is fitted with electric devices limiting the absorbed current during start-up. Each compressor is fitted with manual reset motor thermal protection, controls for the delivery gas temperature and the oil level flow and an electric resistance to heat the carter while the compressor is stopped. A check valve on the refrigerant outlet assures the compressor from the risk of reverse rotation after stopping. A compressor discharge valve is used to force the refrigerant into the heat exchangers during the compressors maintenance operation. Shell and Tube DX / Flooded type evaporator with water flowing inside and refrigerant flowing outside the pipes. Steel shell should be insulated with a foamed closed-cell elastomer 10 mm thickness and 0.033 W/make at 0°C thermal conductivity. Internal copper tubes should be mechanically fitted onto the plates and grooved internally to enhance the heat exchange between refrigerant and water. A differential pressure switch should be present as standard to control the water flow while the unit is working preventing the ice formation. The heat exchanger should be comply with ASME- U stamp concerning the operating pressures and stresses. Shell and Tube DX / Flooded type condenser with water flowing inside and refrigerant flowing outside the pipes. The copper tubes should be internally and externally grooved to improve heat exchange. The heat exchanger comply with ASME/GB/PED standards, concerning to operating pressure. The unit mounted starter panel shall be complete with IP-55 protection consisting of power disconnecting switches with fuses, star-delta starters for compressor motors, Starters for the condenser fans, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with acrylic paint. The chiller shall be mouted on the spring isolators. The quoted price should also be inclusive of PVC Mesh / Frame for protecting Condenser Fins from Factory.,Ambient Wet Bulb Temperature : 95°F,Chiller Nominal capacity : 150.0 TR (2w+1s) with soft starter twin compressor and twin circuit. Flow Rate : 360 Gpm, Chilled water leaving temperature : 44 °F, Chilled water entering temperature : 54 °F Evaporator Fouling Factor : 0.0001 FPS, Condensor water leaving temperature : 95 °F, Condensor water entering temperature : 85 °F, Condensor Fouling Factor : 0.00025 FPS,COP Minimum of 6.0 at AHRI Conditions , IKW-0.61, IPLV Minimum 8.4 at AHRI conditon The item shall include, suitable VFD and harmonic Filter for Thdi <5% , Cable end termination, earthing, control wiring, Spring isolators/Rubber Mounts, Grooved Coupling with spool piece both evaporator & condenser, required number of water Flow Switch, 24G Aluminium Cladding for Evaporator, BMS integration, and Client witnessing of Four point Factory Inspection at AHRI Certified Test Bed and complaince to technical specifications
COOLING TOWERS.Supply, installation, testing & commissioning of CTI Certified Single Cell Induced Draft Counter Flow Cooling Tower(With VFD) for air-conditioning system. The Basin and casing shall be supported by heavy gauge MS hot-dip galvanized steel for long life and durability. Standard accessories shall include overflow, drain and brass make-up valve with plastic float. The Casing and Basin shall be made out of FRP pigmented from outside. Fans shall be heavy duty Axial type statically balanced. The fans constructed of hollow FRP/ extruded aluminium alloy blades, installed in a closely fitted cowl with venturi air inlet. Fan screens shall be galvanized steel mesh and frame, bolted to the fan cowl.Suitable capacity totally enclosed fan-cooled (TEFC)/totally enclosed Surface-cooled (TESC) fan motors, will be furnished suitable for outdoor service on 415 volts, 50 hertz, and 3 phase AC supply. The Fan Motor shall be IE-3, 3 pole, and shall be vertically flange mounted. IE-3 Motor shall be VFD compatible, 415±10% volts, 50 cycles and 3 phase power supply The fan shall be directly mounted to the Motor shaft in direct drive system The Cooling Tower Fill shall be of Virgin PVC (Polyvinyl Chloride) of cross-fluted design for optimum heat transfer and efficiency. The cross fluted sheets shall be bonded together and the edges double folded for strength and durability. The PVC fill shall be resistant to rot, decay, or biological attack.The spray header and branches shall be constructed of Heavy duty, polyvinyl chloride pipe for corRosion resistance and shall have a steel connection to attach the external piping. The piping shall be removable for cleaning purposes. The water shall be distributed over the fill by precision moulded ABS spray nozzles with large orifice openings to eliminate clogging.The spray header and branches shall be constructed of Heavy duty, polyvinyl chloride pipe for corRosion resistance and shall have a steel connection to attach the external piping. The piping shall be removable for cleaning purposes. The water shall be distributed over the fill by precision moulded ABS spray nozzles with large orifice openings to eliminate clogging.The eliminators shall be constructed entirely of inert polyvinyl chloride (PVC) in easily handled sections. The eliminator design shall incorporate two changes in air direction to assure complete removal of all entrained moisture from the discharge air stream. Maximum drift rate shall be less than 0.005% of the circulating water rate.The louvers shall be constructed fRom polyvinyl chloride (PVC). The louvers shall be mounted in easily removable frames for access to the Basin for maintenance. The louvers shall be suitable angled and spaced to prevent splash out and block direct sunlight.All Basin and casing materials will be outside finished in standard colour with NPG, u. v. stabilizer gel coat. Water Flow Rate : 450 USGPM. Ambient Wet Bulb Temperature : 82°F (28.0°C) Condenser water leaving temperature : 95 °F (35.0°C) Condenser water entering temperature : 85 °F (29.4°C) Cooling tower Approach : 6 °F (3.3°C) The item shall include, suitable Starter Panel with VFD with C1 Filter as per IEEE, Electrical Cable from Starter panle to CT, end termination, earthing complete in all respects
Pump logic Controller and parallel pumping software for each pump for Variable Primary Flow operation and to communicate with BMS. Quoted price must include necessary Differential pressure sensor / Transmitter including Supply, Installation, Testing, Commissioning of Electrical panel including all accessories, contRols including enclosure necessary A/M switches of the following Capacities. Panel shall be IP 54 type. PID Looping, PLC & motor must be sourced from pump OEM.
EXHAUST AIR UNTIS. Supply, installation, testing & commissioning of Double skin construction draw thru type Horizontal Floor Mounted with 0.6mm plain GI inner skin and 0.6mm pre coated GI outer skin, 23 mm thick Sandwiched PUF insulation of 40kg/m3 density Extruded Hollow Aluminium PRofile as per specification. The exhaust fan shall be outdoor mountable unit with canopy Exhaust Air unit Section - Intake Section + MERV 8 Filter + Plug Fan / DIDW Forward Curved Fan + IE 3 Motor. 1,550 CFM / 15mm TSP . The Equipment shall Include Suitable VFD /YD Starter as per Tech Spec, Starter panel , Cable from the Equipmnet to the starter, end terminations. earthing etc.
EXHAUST AIR UNTIS. Supply, installation, testing & commissioning of Double skin construction draw thru type Horizontal Floor Mounted with 0.6mm plain GI inner skin and 0.6mm pre coated GI outer skin, 23 mm thick Sandwiched PUF insulation of 40kg/m3 density Extruded Hollow Aluminium PRofile as per specification. The exhaust fan shall be outdoor mountable unit with canopy Exhaust Air unit Section - Intake Section + MERV 8 Filter + Plug Fan / DIDW Forward Curved Fan + IE 3 Motor. 2,000 CFM / 15mm TSP The Equipment shall Include Suitable VFD /YD Starter as per Tech Spec, Starter panel , Cable from the Equipmnet to the starter, end terminations. earthing etc.
EXHAUST AIR UNTIS. Supply, installation, testing & commissioning of Double skin construction draw thru type Horizontal Floor Mounted with 0.6mm plain GI inner skin and 0.6mm pre coated GI outer skin, 23 mm thick Sandwiched PUF insulation of 40kg/m3 density Extruded Hollow Aluminium PRofile as per specification. The exhaust fan shall be outdoor mountable unit with canopy Exhaust Air unit Section - Intake Section + MERV 8 Filter + Plug Fan / DIDW Forward Curved Fan + IE 3 Motor. 2,500 CFM / 15mm TSP The Equipment shall Include Suitable VFD /YD Starter as per Tech Spec, Starter panel , Cable from the Equipmnet to the starter, end terminations. earthing etc.
Supply, installation, testing & commissioning of SMOKE SPILL FANS as per specifications. Fan shall be with direct driven tube axial fan. Fan and casing shall be suitable for smoke exhaust application. Motor shall be mounted outside ,so that it is not exposed to smoke stream & thermally rated for 250° C for 2 hours as per [BS-7346 Part-2 : 1090] Class-B. Motors shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply and static pressure shall be as indicated. Fans shall be activated fRom fire signal from fire alarm system. The fan shall be equipped with mounting bracket & outlet core required at discharge. Fan shall be with flexible fire proof flexible connection at inlet and outlet. Fan capacity shall be as follows. 12,000CFM @ 50mm TSP - AUDI 1 & 2 Equipment shall Include Suitable VFD Starter as per Tech Spec, Starter panel , Cable from the Equipmnet to the starter, end terminations. earthing etc.
Supply, installation, testing & commissioning of SMOKE SPILL FANS as per specifications. Fan shall be with direct driven tube axial fan. Fan and casing shall be suitable for smoke exhaust application. Motor shall be mounted outside ,so that it is not exposed to smoke stream & thermally rated for 250° C for 2 hours as per [BS-7346 Part-2 : 1090] Class-B. Motors shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply and static pressure shall be as indicated. Fans shall be activated fRom fire signal from fire alarm system. The fan shall be equipped with mounting bracket & outlet core required at discharge. Fan shall be with flexible fire proof flexible connection at inlet and outlet. Fan capacity shall be as follows. 15,000CFM @ 50mm TSP - AUDI 3 The Equipment shall Include Suitable VFD Starter as per Tech Spec, Starter panel , Cable from the Equipmnet to the starter, end terminations. earthing etc.
Supply, installation, testing & commissioning of Ceiling suspended chilled water Fan Coil Unit (FCU) with Single skin construction complete with pre filters, 4 Row cooling coil, blower with motor arrangement shall be suitable for 220 +10% volts, 50 Hz, 1 Phase AC supply, drain pan to be provided. The Cost of Thermostat to be included and is with BMS compatible. The height of the FCU shall not be more than 350mm height. 1 TR / 400 CFM - 1F Cloak Room The Equipment shall Include Cable from the Equipmnet to the panel, end terminations. earthing etc.
Supply, installation, testing & commissioning of Ceiling suspended chilled water Fan Coil Unit (FCU) with Single skin construction complete with pre filters, 4 Row cooling coil, blower with motor arrangement shall be suitable for 220 +10% volts, 50 Hz, 1 Phase AC supply, drain pan to be provided. The Cost of Thermostat to be included and is with BMS compatible. The height of the FCU shall not be more than 350mm height. 1 TR / 400 CFM - 1F Ticket Counter The Equipment shall Include Cable from the Equipmnet to the panel, end terminations. earthing etc.
Supply, installation, testing & commissioning of Ceiling suspended chilled water Fan Coil Unit (FCU) with Single skin construction complete with pre filters, 4 Row cooling coil, blower with motor arrangement shall be suitable for 220 +10% volts, 50 Hz, 1 Phase AC supply, drain pan to be provided. The Cost of Thermostat to be included and is with BMS compatible. The height of the FCU shall not be more than 350mm height. 1.5 TR / 400 CFM - 2F Electrical Rom v
CHILLED WATER HI-WALL UNITS. Supply, installation, testing & commissioning of water Hi-wall unit with filter, chilled water cooling coil, blower with motor arrangement shall be suitable for 220 +10% volts, 50 Hz, 1 Phase AC supply. 1.0 TR (hi-wall Unit). The Equipment shall Include Cable from the Equipmnet to the panel, end terminations. earthing etc.
CHILLED WATER HI-WALL UNITS. Supply, installation, testing & commissioning of water Hi-wall unit with filter, chilled water cooling coil, blower with motor arrangement shall be suitable for 220 +10% volts, 50 Hz, 1 Phase AC supply. 1.5 TR - 2F Projector Room (Hi-wall unit). The Equipment shall Include Cable from the Equipmnet to the panel, end terminations. earthing etc.
CHILLED WATER HI-WALL UNITS. Supply, installation, testing & commissioning of water Hi-wall unit with filter, chilled water cooling coil, blower with motor arrangement shall be suitable for 220 +10% volts, 50 Hz, 1 Phase AC supply. 2.0 TR (Hi-wall unit). The Equipment shall Include Cable from the Equipmnet to the panel, end terminations. earthing etc.
Supply, installation of Factory fitted Valve Package with insulation consisting of Ball Valve, Ball Valve with strainer & PIBCV Valve, insulated tray, Copper connection with union & necessary accessories. (for Chilled water Fan coil units & Hi-wall ) Dia 32mm, Power supply for PIBCV etc
Supply, installation of Factory fitted Valve Package with insulation consisting of Ball Valve, Ball Valve with strainer & PIBCV Valve, insulated tray, Copper connection with union & necessary accessories. (for Chilled water Fan coil units & Hi-wall ) Dia 25mm Power supply for PIBCV etc
Supply, installation of Factory fitted Valve Package with insulation consisting of Ball Valve, Ball Valve with strainer & PIBCV Valve, insulated tray, Copper connection with union & necessary accessories. (for Chilled water Fan coil units & Hi-wall ) Dia20mm Power supply for PIBCV etc
Supply, Installation, Testing and Commissioning of Valve station consists of MS piping and manifolds with required valve set. All valves shall be of PN-16 pressure rating. Quoted price shall be inclusive of factory laminated thermal insulation. ( For Ceiling suspended units & Treated fresh air units ). Each valve station consist of :- ( Butterfly valve / Ball valve - 4 Nos ) + ( Y strainers - 1 No ) + ( PIBCV - 1 No ) + ( Auto Air vent - 1 No ) + ( Drain valve - 2Nos ) + ( Test Point - 2 Nos ) + Bypass line. 80 mm dia - ( 50mm Nitrile rubber insulation )
Supply, Installation, Testing and Commissioning of Valve station consists of MS piping and manifolds with required valve set. All valves shall be of PN-16 pressure rating. Quoted price shall be inclusive of factory laminated thermal insulation. ( For Ceiling suspended units & Treated fresh air units ). Each valve station consist of :- ( Butterfly valve / Ball valve - 4 Nos ) + ( Y strainers - 1 No ) + ( PIBCV - 1 No ) + ( Auto Air vent - 1 No ) + ( Drain valve - 2Nos ) + ( Test Point - 2 Nos ) + Bypass line. 65 mm dia -( 50mm Nitrile rubber insulation )
Supply, Installation, Testing and Commissioning of Valve station consists of MS piping and manifolds with required valve set. All valves shall be of PN-16 pressure rating. Quoted price shall be inclusive of factory laminated thermal insulation. ( For Ceiling suspended units & Treated fresh air units ). Each valve station consist of :- ( Butterfly valve / Ball valve - 4 Nos ) + ( Y strainers - 1 No ) + ( PIBCV - 1 No ) + ( Auto Air vent - 1 No ) + ( Drain valve - 2Nos ) + ( Test Point - 2 Nos ) + Bypass line. 50 mm dia - ( 50mm Nitrile rubber insulation )
Supply, Installation, Testing and Commissioning of Valve station consists of MS piping and manifolds with required valve set. All valves shall be of PN-16 pressure rating. Quoted price shall be inclusive of factory laminated thermal insulation. ( For Ceiling suspended units & Treated fresh air units ). Each valve station consist of :- ( Butterfly valve / Ball valve - 4 Nos ) + ( Y strainers - 1 No ) + ( PIBCV - 1 No ) + ( Auto Air vent - 1 No ) + ( Drain valve - 2Nos ) + ( Test Point - 2 Nos ) + Bypass line. 40 mm dia - ( 50mm Nitrile rubber insulation )
Supply, Installation, Testing and Commissioning of Valve station consists of MS piping and manifolds with required valve set. All valves shall be of PN-16 pressure rating. Quoted price shall be inclusive of factory laminated thermal insulation. ( For Ceiling suspended units & Treated fresh air units ). Each valve station consist of :- ( Butterfly valve / Ball valve - 4 Nos ) + ( Y strainers - 1 No ) + ( PIBCV - 1 No ) + ( Auto Air vent - 1 No ) + ( Drain valve - 2Nos ) + ( Test Point - 2 Nos ) + Bypass line. 32 mm dia - ( 50mm Nitrile rubber insulation )
Supply & installation of digital thermostat for CSU & FCU return air sensor with BMS compatible
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 250 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 200 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 150 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 125 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 100 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well.80 mm dia - ( 50mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 65 mm dia - ( 50mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 50 mm dia - ( 50mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 40 mm dia - ( 50mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 32 mm dia - ( 50mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is 24G GI. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well. 25 mm dia - ( 50mm )
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 200 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 150 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 125 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 100 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 80 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 65 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 50 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 40 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 32 mm dia
CONDENSER WATER PIPING. Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 250 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 200 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 150 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 125 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 100 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 80 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 65 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 50 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 40 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 32 mm dia
Supply, installation, testing & commissioning of MS class ‘C’ pipes for cut to required lengths and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. 25 mm dia
UNDER GROUND CHILLED WATER PIPING. Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is HDPE. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well.
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is HDPE. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well.250 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is HDPE. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well.200 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is HDPE. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well.150 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is HDPE. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well.125 mm dia - ( 75mm )
Supply, installation, testing & commissioning of Factory Pre Insulated MS class ‘C’ pipes with rigid polyurethane foam with Density of 48 kg/cu mtr and has to be CFC free, the outer casing material is HDPE. The pipe should withstand -50 deg cel to +140 deg cel temperature. The pipes has to comply Class O fire rating in which having Class 1 fire rating. For chilled water cut to required length and installed with all welded joints, providing and fixing in position with the necessary (PUF Saddle supports), fittings like elbows, tees and reducers, sockets for probe meter, Hitech support hangers with vibration isolation arrangement as per specification. This includes PUF insulation and jacket of the fittings as well.100 mm dia - ( 75mm )
BUTTERFLY VALVES. Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton. 350 mm dia
BUTTERFLY VALVES. Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton.300 mm dia
Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton.250 mm dia
Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton. 200 mm dia
Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton.150 mm dia
Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton.125 mm dia
Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton.100 mm dia
Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton. 80 mm dia
Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton. 65 mm dia
Supply, Installation, testing & commissioning of Wafer type Butterfly Valves, Cast IRon Body, SS-410 Disc with Nyloned Coated, SS-431 Stem ,EPDM integrally Moulded Liner with Hand Lever Operated Pressure Rating PN16 as per specificaiton. 50 mm dia
BALL VALVES. Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 40 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 32 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 25 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 20 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 15 mm dia
MANUAL BALANCING VALVE. Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 350 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 300 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 250 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 200 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 150 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 125 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 100 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 80 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges.65 mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve . 25mm to 50mm - Cast Bronze Screwed End Construction Type –II & with Pressure test Cocks and Drain Valve as per specfication. 65mm and above - Cast Iron Flanged with Pressure Test Cocks only in SS-410 Stem, EN-3 Disc and EPDM Sealing Disc The cost to include water balancing charges. 50 mm dia
Supply, installation, testing & commissioning of Pressure independent 2 way modulating flow Control valves (PIBCV) in a single Unit of Valve. Diaphragm type .The valve Shall be PN16 Rating with matching flanges, suitable Actuator. Digital Thermostat cost to be included DN 15 to DN 32 Brass Body Extension Threaded DN 40 & DN 50 Grey Cast Iron Body with Extension Threaded DN 65 to DN 250 Grey Cast Iron body with Flanged Ends Connection as per specification. 100 mm dia
Supply, installation, testing & commissioning of Pressure independent 2 way modulating flow Control valves (PIBCV) in a single Unit of Valve. Diaphragm type .The valve Shall be PN16 Rating with matching flanges, suitable Actuator. Digital Thermostat cost to be included DN 15 to DN 32 Brass Body Extension Threaded DN 40 & DN 50 Grey Cast Iron Body with Extension Threaded DN 65 to DN 250 Grey Cast Iron body with Flanged Ends Connection as per specification. 80 mm dia
Supply, installation, testing & commissioning of Pressure independent 2 way modulating flow Control valves (PIBCV) in a single Unit of Valve. Diaphragm type .The valve Shall be PN16 Rating with matching flanges, suitable Actuator. Digital Thermostat cost to be included DN 15 to DN 32 Brass Body Extension Threaded DN 40 & DN 50 Grey Cast Iron Body with Extension Threaded DN 65 to DN 250 Grey Cast Iron body with Flanged Ends Connection as per specification. 65 mm dia
Supply, installation, testing & commissioning of Pressure independent 2 way modulating flow Control valves (PIBCV) in a single Unit of Valve. Diaphragm type .The valve Shall be PN16 Rating with matching flanges, suitable Actuator. Digital Thermostat cost to be included DN 15 to DN 32 Brass Body Extension Threaded DN 40 & DN 50 Grey Cast Iron Body with Extension Threaded DN 65 to DN 250 Grey Cast Iron body with Flanged Ends Connection as per specification. 50 mm dia
Supply, installation, testing & commissioning of Pressure independent 2 way modulating flow Control valves (PIBCV) in a single Unit of Valve. Diaphragm type .The valve Shall be PN16 Rating with matching flanges, suitable Actuator. Digital Thermostat cost to be included DN 15 to DN 32 Brass Body Extension Threaded DN 40 & DN 50 Grey Cast Iron Body with Extension Threaded DN 65 to DN 250 Grey Cast Iron body with Flanged Ends Connection as per specification. 40 mm dia
Supply, installation, testing & commissioning of Wafer Type Dual Plate Check Valves, Cast Iron to IS 210 Gr. FG 260, ASTM A-217 Gr. CA-15 (SS-410) Plates, SS-410 Hinge/Stop Pin, SS-316 Spring(s), Buna-N Seal to suit flanges BS-10 Table 'E' as per specificaiton. 250 mm dia
Supply, installation, testing & commissioning of Wafer Type Dual Plate Check Valves, Cast Iron to IS 210 Gr. FG 260, ASTM A-217 Gr. CA-15 (SS-410) Plates, SS-410 Hinge/Stop Pin, SS-316 Spring(s), Buna-N Seal to suit flanges BS-10 Table 'E' as per specificaiton. 200 mm dia
Supply, installation, testing & commissioning of Wafer Type Dual Plate Check Valves, Cast Iron to IS 210 Gr. FG 260, ASTM A-217 Gr. CA-15 (SS-410) Plates, SS-410 Hinge/Stop Pin, SS-316 Spring(s), Buna-N Seal to suit flanges BS-10 Table 'E' as per specificaiton. 150 mm dia
Supply, installation, testing & commissioning of Wafer Type Dual Plate Check Valves, Cast Iron to IS 210 Gr. FG 260, ASTM A-217 Gr. CA-15 (SS-410) Plates, SS-410 Hinge/Stop Pin, SS-316 Spring(s), Buna-N Seal to suit flanges BS-10 Table 'E' as per specificaiton. 125 mm dia
Supply, installation, testing & commissioning of Wafer Type Dual Plate Check Valves, Cast Iron to IS 210 Gr. FG 260, ASTM A-217 Gr. CA-15 (SS-410) Plates, SS-410 Hinge/Stop Pin, SS-316 Spring(s), Buna-N Seal to suit flanges BS-10 Table 'E' as per specificaiton. 100 mm dia
Supply, installation, testing & commissioning of Mild Steel Suction Guide Complete With Star Shaped Stainless Steel Filter Screen Of 3mm Perforation With Fine Wire mesh Start up Filter Flanged End Connection Pressure Rating PN 16.250 mm dia
Supply, installation, testing & commissioning of Mild Steel Suction Guide Complete With Star Shaped Stainless Steel Filter Screen Of 3mm Perforation With Fine Wire mesh Start up Filter Flanged End Connection Pressure Rating PN 16.200 mm dia
Supply, installation, testing & commissioning of Mild Steel Suction Guide Complete With Star Shaped Stainless Steel Filter Screen Of 3mm Perforation With Fine Wire mesh Start up Filter Flanged End Connection Pressure Rating PN 16.150 mm dia
Supply, installation, testing & commissioning of Mild Steel Suction Guide Complete With Star Shaped Stainless Steel Filter Screen Of 3mm Perforation With Fine Wire mesh Start up Filter Flanged End Connection Pressure Rating PN 16. 125 mm dia
Supply, installation, testing & commissioning of Mild Steel Suction Guide Complete With Star Shaped Stainless Steel Filter Screen Of 3mm Perforation With Fine Wire mesh Start up Filter Flanged End Connection Pressure Rating PN 16. 100 mm dia
Supply, installation, testing & commissioning of Y Type STRAINERS with bronze Filter Screen of 3mm Perforation X 24G. Flanged End Connection. Flanges as per BS 10 Table D MOC as below with PN 16 rating up to 65mm Cast Iron 80mm and above Mild Steel. 200 mm dia
Supply, installation, testing & commissioning of Y Type STRAINERS with bronze Filter Screen of 3mm Perforation X 24G. Flanged End Connection. Flanges as per BS 10 Table D MOC as below with PN 16 rating up to 65mm Cast Iron 80mm and above Mild Steel. 150 mm dia
Supply, installation, testing & commissioning of Y Type STRAINERS with bronze Filter Screen of 3mm Perforation X 24G. Flanged End Connection. Flanges as per BS 10 Table D MOC as below with PN 16 rating up to 65mm Cast Iron 80mm and above Mild Steel. 125 mm dia
Supply, installation, testing & commissioning of Y Type STRAINERS with bronze Filter Screen of 3mm Perforation X 24G. Flanged End Connection. Flanges as per BS 10 Table D MOC as below with PN 16 rating up to 65mm Cast Iron 80mm and above Mild Steel. 100 mm dia
Supply, installation, testing & commissioning of Y Type STRAINERS with bronze Filter Screen of 3mm Perforation X 24G. Flanged End Connection. Flanges as per BS 10 Table D MOC as below with PN 16 rating up to 65mm Cast Iron 80mm and above Mild Steel. 80 mm dia
Supply, installation, testing & commissioning of Y Type STRAINERS with bronze Filter Screen of 3mm Perforation X 24G. Flanged End Connection. Flanges as per BS 10 Table D MOC as below with PN 16 rating up to 65mm Cast Iron 80mm and above Mild Steel. 65 mm dia
Supply, installation, testing & commissioning of Y Type STRAINERS with bronze Filter Screen of 3mm Perforation X 24G. Flanged End Connection. Flanges as per BS 10 Table D MOC as below with PN 16 rating up to 65mm Cast Iron 80mm and above Mild Steel. 50 mm dia
Supply, installation, testing & commissioning of Y Type STRAINERS with bronze Filter Screen of 3mm Perforation X 24G. Flanged End Connection. Flanges as per BS 10 Table D MOC as below with PN 16 rating up to 65mm Cast Iron 80mm and above Mild Steel. 40 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM.. 250 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM. 200 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM.150 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM.125 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM.100 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM.80 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM.65 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM.50 mm dia
Supply, installation, testing & commissioning of Motorised Butterfly Valve Wafer type PN 16 Cast IRon Body Ductile (SG) IRon Disc with Insulation Ready Neck with Nylon Coated, SS-431 Stem, EPDM integrally Moulded Liner. Non Spring Type on/off Actuator, Close off Pressure 1000 KPA, Power Supply 230VAC with 2 in built SPDT with IP68.. The required NONC contact to be considered for integration Chiller/CPM.40 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E. 250 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E. 200 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E. 150 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E. 125 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E.100 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E.80 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E.65 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E.50 mm dia
Supply, installation, testing & commissioning of Neoprene Rubber Single Arch Expansion Joint (PN-16) with MS Split retainer rings and contRol units drilled to BS 10 table E.40 mm dia
Supply, installation, testing & commissioning of 100mm dia (4") SS Temperature Gauge Range 0-50 Deg C With 4" Stem Length & SS Thermowell o be included.
Supply, installation, testing & commissioning of 100mm dia (4") SS Pressure Gauge with 3/8" BSP Connection, Bottom Entry Range 0-10kg/cm2, SS Syphon Size 3/8", Ball Valve Size 3/8"
Supply, installation testing & commissioning of Auto Air vents with ball valve as per specification. 15 mm dia
Supply, installation testing & commissioning of Auto Air vents with ball valve as per specification.20 mm dia
Supply, installation testing & commissioning of Auto Air vents with ball valve as per specification. 25 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 %
BALL VALVES. Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 40 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 32 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 25 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 20 mm dia
Supply, installation, testing & commissioning of Full Bore Ball Valve with Screwed F-F ends, Nickel plated Brass body, Lever handle in Steel, Temperature -20°C, 150°C, Thread Ball Valve with Led Content below 2.5 % as per specificaiton. 15 mm dia
Supply, installation, testing & commissioning of Test points made of Brass material with 1/4" connection size for taking pressure & temperature measurements
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class. 300 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class.250 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class.200 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class.150 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class.125 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class.100 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class.80 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class.65 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class. 50 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class. 40 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class. 32 mm dia
Supply, installation, testing & commissioning of Ultrasonic BTU meters for measurement of cooling consumption complete with flow measurement part, two temp sensors and a calculator. The device shall be suitable for remote readout and control and shall be mountable on the pipelines in any orientation. The BTU Meter shall to be BMS compatible and all the required arrangements for the same to be included. In built Battery minimum 6 years, Non-volatile memory, Communication with IP/ RS 485 and open protocol & IP65 class. 25 mm dia
Soft Integration for BMS Compatable Equipments
Supplying, installing, testing and commissioning of BTU Meter billing Software to be capable of monitoring BTU meters
Supply and installation of Thermowell for BMS / BTU Meter sensors
Supply, installation, testing & commissioning of CPVC drain pipe insulated with 13mm nitrile rubber insulation fRom each AHU / CSU to nearest drain trap/point. The cost to include necessary fittings & Hitech supports. 65 mm dia
Supply, installation, testing & commissioning of CPVC drain pipe insulated with 13mm nitrile rubber insulation fRom each AHU / CSU to nearest drain trap/point. The cost to include necessary fittings & Hitech supports. 50 mm dia
Supply, installation, testing & commissioning of CPVC drain pipe insulated with 13mm nitrile rubber insulation fRom each AHU / CSU to nearest drain trap/point. The cost to include necessary fittings & Hitech supports. 40 mm dia
Supply, installation, testing & commissioning of CPVC drain pipe insulated with 13mm nitrile rubber insulation fRom each AHU / CSU to nearest drain trap/point. The cost to include necessary fittings & Hitech supports.32 mm dia
Supply, installation, testing & commissioning of CPVC drain pipe insulated with 13mm nitrile rubber insulation fRom each AHU / CSU to nearest drain trap/point. The cost to include necessary fittings & Hitech supports.25 mm dia
Supply, fabrication, installation of MS supports as per site requirement with Channels, Angles, flats with painting for pipes, valves etc. (Excluding Chiller/pump set/Plant Room structural works)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding.350 mm dia (75 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding. 300 mm dia (75 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding.250 mm dia (75 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding.200 mm dia (75 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding.150 mm dia (50 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding.125 mm dia (50 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding.100 mm dia (50 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding. 80 mm dia (50 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding.65 mm dia (50 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding. 50 mm dia (50 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding. 40 mm dia (50 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding. 32 mm dia (50 mm)
Supply and installation of insulation for all Water distribution Valves with appropriate thickness of 36 kg/m3 density PUF Pipe insulation and covered with Polythene sheet and finished with 24G Aluminium sheet cladding. 25 mm dia (50 mm)
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification. 350 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification. 300 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification. 250 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification. 200 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification.150 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification.125 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification.100 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification.80 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification. 65 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification.50 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification.40 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification.32 mm dia
The Condenser pipe to be wrapped with Glass cloth and applied with star bond coating of 30-36 & Architect/client approved colour paint to prevent from rust/corrosion as per specification.25 mm dia
Supply, installation, testing & commissioning of Closed loop expansion tank as per standards & requirements. The tank shall be made of mild steel and shall a synthetic rubber membrane and insulation. Nitrogen gas or compressed air is filled in space between the membrane and the wall of the tank. The tank should be supplied complete with booster pumps (1W+1S), isolating valve, check valve, drain valve & pressure gauge. Before connecting the tank to water system, the gas pressure should be checked through the charging valve and adjusted according to the requirements, the control panel should also be included. Cabling and end terminations from starters/panels to HVAC equipment to be done by the HVAC contractor. Following capacity to be provided. 1000 Litres - Closed loop expansion tank - PN 16
Pressurisation Unit complete with double pump, IP55 control panel, pressure transmitter, flow meter, interconnecting piping & wiring. Pressurisation unit (1W+1S Pumps) with safety valve, Canopy for outdoor installation with PN 16 pressure rating.
Supply, installation, testing & commissioning of Air and Dirt Separator made out of MS Sheet, 19mm Nitrile rubber insulation with 24G aluminium cladding for chilled water application inside plant Room. Cabling and end terminations fRom starters/panels to HVAC equipment to be done by the HVAC contractor. (Refer Schematic diagram) 200 mm dia
Supply & installation of ELECTRONIC CHEMICAL DOZING TANK, 100L capacity with Auto injection, complete with necessary pumps (1W+1S) & display, along with supply of pre cleaning chemicals, running chemicals for the DLP period
AIR-DISTRIBUTION WORKS. Supply, Fabrication, Installation and testing of 120GSM Galvanised Sheet Steel metal ducts FACTORY / SITE FABRICATED DUCTS in accordance with the appRoved shop drawings complete with all accessories like vanes, flanges, suspension Rods, anchor bolts, GI bolts & nuts, canvas connections, duct dampers & splitter dampers etc., and as required by the specifications. All size duct should be with TDF / duct mate joints. The gauges shall to be as per SMACNA standards. 24 gauge galvanised sheet steel
Supply, Fabrication, Installation and testing of 120GSM Galvanised Sheet Steel metal ducts FACTORY / SITE FABRICATED DUCTS in accordance with the appRoved shop drawings complete with all accessories like vanes, flanges, suspension Rods, anchor bolts, GI bolts & nuts, canvas connections, duct dampers & splitter dampers etc., and as required by the specifications. All size duct should be with TDF / duct mate joints. The gauges shall to be as per SMACNA standards.22 gauge galvanised sheet steel
Supply, Fabrication, Installation and testing of 120GSM Galvanised Sheet Steel metal ducts FACTORY / SITE FABRICATED DUCTS in accordance with the appRoved shop drawings complete with all accessories like vanes, flanges, suspension Rods, anchor bolts, GI bolts & nuts, canvas connections, duct dampers & splitter dampers etc., and as required by the specifications. All size duct should be with TDF / duct mate joints. The gauges shall to be as per SMACNA standards.20 gauge galvanised sheet steel
Supply, Fabrication, Installation and testing of 120GSM Galvanised Sheet Steel metal ducts FACTORY / SITE FABRICATED DUCTS in accordance with the appRoved shop drawings complete with all accessories like vanes, flanges, suspension Rods, anchor bolts, GI bolts & nuts, canvas connections, duct dampers & splitter dampers etc., and as required by the specifications. All size duct should be with TDF / duct mate joints. The gauges shall to be as per SMACNA standards.18 gauge galvanised sheet steel.
Supply, installation, testing & commissioning of 25 mm thick Double skin Plenum Sandwiched PUF insulation of 40kg/m3 density made of 0.6mm thick G.I plain inside and 0.6mm thick precoated outside with necessary threaded Rods for supporting & anchor fasten.
Supply and installation of 43mm thick thermal break double skin plenum sandwiched PUF insulation of 40kg/m3 density made of 0.6mm thick G.I plain inside and 0.6mm thick percolated outside with necessary threaded Rods for supporting & anchor fasten.
Supply & installation, testing and balancing of Aluminium Powder coated Linear grills of 5mm thickness with 12mm spacing with necessary flanges for supply & return air of the following sizes. Deflections will be based on requirement
Supply & installation, testing and balancing of Opposed blade Extruded Aluminium Collar Damper
Supply and installation of Duct Mounted Back Draft Damper with outer shell constructed out of 16G galvanized steel frame and the blade / Leaf with 22G galvanized steel and with necessary flanges for connection as per specification)
Supply, installation, testing and balancing of Aluminium Volume Control Duct Dampers with operating handle, 150mm Depth Linkage type with quadrant and TDF Flanges for Supply air duct branches in accordance with the appRoved shop drawings and specifications.
Supply, installation, testing and balancing of GSS Volume Control Duct Dampers 20G Frame & 20G Blade with operating handle, 150mm Depth Linkage type with quadrant and TDF Flanges for Supply air duct branches in accordance with the appRoved shop drawings and specifications.
Supply installation testing and commissioning of Fire damper of 16G GI Sheet construction, 16G GI casing and 16G GI blades 150 mm wide complete with chrome plated spindles, self lubricating bushes, 120 minutes fire rating as per UL-555, Aug 2005 certified by CBRI Roorkee complete with standard accessories as per specifications. (Only Damper price of total Cross-sectional Area)
Supply installation testing and commissioning of Spring return Motorized Actuators with auxiliary switch actuators ON/OFF type 24V/230 V for fire dampers as per specification. Actuator to be integrated with FA panel for ON/OFF command.
Torque 4 Nm suitable for damper area 0.6 Sqm
Torque 10 Nm suitable for damper area up to 1.2 Sqm
Supply installation testing and commissioning of Temperature sensors, control panel for Motorized actuators and all accessories as per specification. The panel shall to be supplied fRom Fire damper manufacturer. Single Panel for Each Actuator
Supply installation testing and commissioning of Motorized damper of 16G GI Sheet construction, 16G GI casing and 16G GI blades 150 mm wide complete with chrome plated spindles, self lubricating bushes, 120 minutes fire rating as per UL-555, Aug 2005 certified by CBRI Roorkee complete with standard accessories as per specifications. (Only Damper price of total Cross-sectional Area)
Supply installation testing and commissioning of Spring return Motorized Dampers with auxiliary switch actuators ON/OFF type 24V/230 V for fire dampers as per specification. Actuator to be integrated with FA panel for ON/OFF command. Torque 4 Nm suitable for damper area 0.6 Sqm
Supply installation testing and commissioning of Spring return Motorized Dampers with auxiliary switch actuators ON/OFF type 24V/230 V for fire dampers as per specification. Actuator to be integrated with FA panel for ON/OFF command. Torque 10 Nm suitable for damper area up to 1.2 Sqm
Supply, installation, testing and balancing of powder coated Extruded Aluminium supply air Swirl Diffusers of removable core , in accordance with the approved shop drawings and specifications to fit in the tile size of 600 x 600. The neck size shall be of following sizes. 450 x 450
Supply, installation, testing and balancing of powder coated Extruded Aluminium supply air Swirl Diffusers of removable core , in accordance with the approved shop drawings and specifications to fit in the tile size of 600 x 600. The neck size shall be of following sizes. 375 x 375
Supply, installation, testing and balancing of powder coated Extruded Aluminium supply air Swirl Diffusers of removable core , in accordance with the approved shop drawings and specifications to fit in the tile size of 600 x 600. The neck size shall be of following sizes. 300 x 300
Supply, installation, testing and balancing of powder coated Extruded Aluminium Return air diffusers removable core, in accordance with the approved shop drawings and specifications to fit in the tile size of 600 x 600. The neck size shall be of following sizes. 450 x 450
Supply, installation, testing and balancing of powder coated Extruded Aluminium Return air diffusers removable core, in accordance with the approved shop drawings and specifications to fit in the tile size of 600 x 600. The neck size shall be of following sizes. 375 x 375
Supply, installation, testing and balancing of powder coated Extruded Aluminium Return air diffusers removable core, in accordance with the approved shop drawings and specifications to fit in the tile size of 600 x 600. The neck size shall be of following sizes. 300 x 300
Supply, installation, testing & commissioning of Spill air / Diffuser boxes made of 24G G.I with Round neck necessary threaded Rods for supporting & anchor fasten the of following sizes. As per specification.400 x 200 x 250 H
Supply, installation, testing & commissioning of Spill air / Diffuser boxes made of 24G G.I with Round neck necessary threaded Rods for supporting & anchor fasten the of following sizes. As per specification.400 x 400 x 300 H
Supply, installation, testing & commissioning of Spill air / Diffuser boxes made of 24G G.I with Round neck necessary threaded Rods for supporting & anchor fasten the of following sizes. As per specification.450 x 450 x 350 H
Supply, installation, testing & commissioning of Spill air / Diffuser boxes made of 24G G.I with Round neck necessary threaded Rods for supporting & anchor fasten the of following sizes. As per specification.600 x 600 x 400 H
Rectangular mixing boxes. Supply, installation, testing & commissioning of Round Spigot Butterfly Dampers with 22G Frame& 24G Blade and quadrant operated with one side flange and one side. Single flap, necessary stopper, flanges for fastening on to the duct surface and with grooves for clamping the flexible ducts securely.as per specification.100 mm dia
Rectangular mixing boxes. Supply, installation, testing & commissioning of Round Spigot Butterfly Dampers with 22G Frame& 24G Blade and quadrant operated with one side flange and one side. Single flap, necessary stopper, flanges for fastening on to the duct surface and with grooves for clamping the flexible ducts securely.as per specification.150 mm dia
Rectangular mixing boxes. Supply, installation, testing & commissioning of Round Spigot Butterfly Dampers with 22G Frame& 24G Blade and quadrant operated with one side flange and one side. Single flap, necessary stopper, flanges for fastening on to the duct surface and with grooves for clamping the flexible ducts securely.as per specification.200 mm dia
Rectangular mixing boxes. Supply, installation, testing & commissioning of Round Spigot Butterfly Dampers with 22G Frame& 24G Blade and quadrant operated with one side flange and one side. Single flap, necessary stopper, flanges for fastening on to the duct surface and with grooves for clamping the flexible ducts securely.as per specification.250 mm dia
Rectangular mixing boxes. Supply, installation, testing & commissioning of Round Spigot Butterfly Dampers with 22G Frame& 24G Blade and quadrant operated with one side flange and one side. Single flap, necessary stopper, flanges for fastening on to the duct surface and with grooves for clamping the flexible ducts securely.as per specification.300 mm dia
Supply & installation of 24G GI Circular duct with one end Circular flange & another end with spigot connection for flexible duct connection as per specification.100 mm dia
Supply & installation of 24G GI Circular duct with one end Circular flange & another end with spigot connection for flexible duct connection as per specification.150 mm dia
Supply & installation of 24G GI Circular duct with one end Circular flange & another end with spigot connection for flexible duct connection as per specification.200 mm dia
Supply & installation of 24G GI Circular duct with one end Circular flange & another end with spigot connection for flexible duct connection as per specification.250 mm dia
Supply & installation of 24G GI Circular duct with one end Circular flange & another end with spigot connection for flexible duct connection as per specification.300 mm dia
Supply, Fabrication, installation and testing of the Insulated flexible duct Inner core should be made of double lamination of polyester film permanently bonded to a coated spring steel wire helix. Blanket of glass insulation of R 4.2 (RSI - 0.76 m2K/W) having density of 24 Kg/m3 and thickness of 25 mm shall be wrapped over the inner core and covered with tear and abuse resistant outer jacket cum vapour barrier made of fibre glass reinforced double layer of metalized polyester film laminate. The cost should be including jubilee clamp. 100 mm dia
Supply, Fabrication, installation and testing of the Insulated flexible duct Inner core should be made of double lamination of polyester film permanently bonded to a coated spring steel wire helix. Blanket of glass insulation of R 4.2 (RSI - 0.76 m2K/W) having density of 24 Kg/m3 and thickness of 25 mm shall be wrapped over the inner core and covered with tear and abuse resistant outer jacket cum vapour barrier made of fibre glass reinforced double layer of metalized polyester film laminate. The cost should be including jubilee clamp. 150 mm dia
Supply, Fabrication, installation and testing of the Insulated flexible duct Inner core should be made of double lamination of polyester film permanently bonded to a coated spring steel wire helix. Blanket of glass insulation of R 4.2 (RSI - 0.76 m2K/W) having density of 24 Kg/m3 and thickness of 25 mm shall be wrapped over the inner core and covered with tear and abuse resistant outer jacket cum vapour barrier made of fibre glass reinforced double layer of metalized polyester film laminate. The cost should be including jubilee clamp. 200 mm dia
Supply, Fabrication, installation and testing of the Insulated flexible duct Inner core should be made of double lamination of polyester film permanently bonded to a coated spring steel wire helix. Blanket of glass insulation of R 4.2 (RSI - 0.76 m2K/W) having density of 24 Kg/m3 and thickness of 25 mm shall be wrapped over the inner core and covered with tear and abuse resistant outer jacket cum vapour barrier made of fibre glass reinforced double layer of metalized polyester film laminate. The cost should be including jubilee clamp. 250 mm dia
Supply, Fabrication, installation and testing of the Insulated flexible duct Inner core should be made of double lamination of polyester film permanently bonded to a coated spring steel wire helix. Blanket of glass insulation of R 4.2 (RSI - 0.76 m2K/W) having density of 24 Kg/m3 and thickness of 25 mm shall be wrapped over the inner core and covered with tear and abuse resistant outer jacket cum vapour barrier made of fibre glass reinforced double layer of metalized polyester film laminate. The cost should be including jubilee clamp. 300 mm dia
Supply, Fabrication, installation and testing of the Uninsulated flexible duct shall be made of double lamination of metalized polyester film permanently bonded to a coated spring steel wire helix. Duct shall be in tear and puncture resistant construction. The cost should be including jubilee clamp. 100 mm dia
Supply, Fabrication, installation and testing of the Uninsulated flexible duct shall be made of double lamination of metalized polyester film permanently bonded to a coated spring steel wire helix. Duct shall be in tear and puncture resistant construction. The cost should be including jubilee clamp. 150 mm dia
Supply, Fabrication, installation and testing of the Uninsulated flexible duct shall be made of double lamination of metalized polyester film permanently bonded to a coated spring steel wire helix. Duct shall be in tear and puncture resistant construction. The cost should be including jubilee clamp. 200 mm dia
Supply and installation of Exhaust Valves constructed from steel spinning's with powder coating finish with subframe for easy installation with round flange on one side and groove on other side for fixing of flexible duct. 100 Dia
Supply and installation of Exhaust Valves constructed from steel spinning's with powder coating finish with subframe for easy installation with round flange on one side and groove on other side for fixing of flexible duct. 150 Dia
Supply and installation of Exhaust Valves constructed from steel spinning's with powder coating finish with subframe for easy installation with round flange on one side and groove on other side for fixing of flexible duct. 200 Dia
Supply, Fabrication, installation and testing of the powder coated alluminium grilles, complete with connecting rods with 15 deg inclined, etc as per standards and specification. . 750x300 (STP )EAG
Supply, Fabrication, installation and testing of the powder coated alluminium grilles, complete with connecting rods with 15 deg inclined, etc as per standards and specification. . 750x300 (STP) SAG
Supply and installation of Supply of High grade Extruded Aluminium powder coated Non-Vision Door louvers with both side flange for toilet doors as per specification & approved shop drawing . (With Matching Rear Frame)
Supply & installation, testing and balancing of High grade aluminium extruded Louvers for Fresh air intake & Exhaust air exit at outer wall. The louver shall be of powder coated finish.
Supply and fixing of Elastomeric Open Cell Nitrile Rubber Acoustic insulation of initial duct with below thickness. The density of the insulation shall be 140 - 180 kg / m3 & using high quality Low VOC adhesive as per OEM recommended and standard. The thermal conductivity should be 0.047 W/m Deg K@ 20deg cel. The temperature range should be + 105 Deg C to -20 Deg C. The insulation shall be of Class '1'. 15mm
Supply and fixing of Elastomeric CLOSED cell Nitrile Rubber Thermal insulation. The density of the insulation shall be 48 kg / m3 & using high quality Low VOC adhesive as per OEM recommended and standard. The thermal conductivity should be 0.035 W/m Deg K@ 20deg cel. The temperature range should be + 85 Deg C to -40 Deg C. insulation shall be of Class 'O'. 13 mm with factory laminated Aluminium foil
Supply and fixing of Elastomeric CLOSED cell Nitrile Rubber Thermal insulation. The density of the insulation shall be 48 kg / m3 & using high quality Low VOC adhesive as per OEM recommended and standard. The thermal conductivity should be 0.035 W/m Deg K@ 20deg cel. The temperature range should be + 85 Deg C to -40 Deg C. insulation shall be of Class 'O'. 19 mm with factory laminated Aluminium foil
Supply and fixing of Elastomeric CLOSED cell Nitrile Rubber Thermal insulation. The density of the insulation shall be 48 kg / m3 & using high quality Low VOC adhesive as per OEM recommended and standard. The thermal conductivity should be 0.035 W/m Deg K@ 20deg cel. The temperature range should be + 85 Deg C to -40 Deg C. insulation shall be of Class 'O'. 19 mm with factory laminated Aluminium foil - Underdeck Insulation
Supply and fixing of Elastomeric CLOSED cell Nitrile Rubber Thermal insulation. The density of the insulation shall be 48 kg / m3 & using high quality Low VOC adhesive as per OEM recommended and standard. The thermal conductivity should be 0.035 W/m Deg K@ 20deg cel. The temperature range should be + 85 Deg C to -40 Deg C. insulation shall be of Class 'O'. 25 mm with factory laminated Aluminium foil - Underdeck Insulation
DX TYPE CASSETTE UNITS. Supply, installation, testing and commissioning of 4-way Casstee unit.The units should be complete with inbuilt drain pump, controls, microprocessor control panel, wiring, etc.The unit shall be charged with R-410A refrigerant. The outdoor unit shall be complete with Rotary compressor, condenser fans and other accessories. The noise level shall not be more than 55 dB(A)at normal operation measured horizontally 1m away and 1.5m above ground.The quoted price shall be inclusive of cord remote control, wiring, electrical cable with plug fRom isolator provided by others near outdoor to indoor unit. The quote should include the copper pipe length should not increase more than 15-20 metre. MS Supporting arrangements for outdoor units including necessary MS frames,stands, anti-corrosive paints, accessories, including hardware for suspension , floor mounting , grouting etc.The capacities of each machine and quantities are as indicated below. 4-way 1.5 TR Cassette unit
ACCOUSTICS & INSULATIONS. Supply, installation, testing and commissioning of 4-way Casstee unit.The units should be complete with inbuilt drain pump, controls, microprocessor control panel, wiring, etc.The unit shall be charged with R-410A refrigerant. The outdoor unit shall be complete with Rotary compressor, condenser fans and other accessories. The noise level shall not be more than 55 dB(A)at normal operation measured horizontally 1m away and 1.5m above ground.The quoted price shall be inclusive of cord remote control, wiring, electrical cable with plug fRom isolator provided by others near outdoor to indoor unit. The quote should include the copper pipe length should not increase more than 15-20 metre. MS Supporting arrangements for outdoor units including necessary MS frames,stands, anti-corrosive paints, accessories, including hardware for suspension , floor mounting , grouting etc.The capacities of each machine and quantities are as indicated below. 4-way 3.0 TR Cassette unit
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)200 mm dia
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)150 mm dia
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)125 mm dia
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)100 mm dia
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)80 mm dia
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)65 mm dia
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)50 mm dia
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)40 mm dia
Supply, installation and testing of TF Quality Class 'O' Nitrile rubber of preformed pipe section ( Thicknes as below ) for all pipes with factory laminated aluminum foil facing,, 'fittings, valves, unions, etc as per specifications. The exposed pipes on terrace shall be with FRP lining and quoted with uv protective paints. Insulation thickness Details (dia 25 mm pipe -19 mm thick. dia 32 mm - 80 mm pipe -25 mm thick. dia 100 mm - 250 mm pipe -32 mm thick. dia 300 mm - 600 mm pipe -40 mm thick.)32 mm dia
Supply, installation and testing of Acoustic lining for supply and return air ducts with 25 mm thick rigid fibre glass of 48Kg/Cum density covered with factory laminated RP Tissue and finished with with 26G Perforated Aluminium sheet as per the specifications and as detailed in the drawings.
Supply and installation of External Thermal insulation on ducts with 9mm Thick Closed Cell Nitrile Rubber Insulation with 60 kg/Cu.Mt. as per specifications and standard drawings. Quoted price shlall be inclusive of adhesive ,tapes, etc
Supply, installation, testing & commissioning of centrifugal STP VENTILATION AIR UNIT suitable for Indoor installation, Each complete with Forward Curved Centrifugal Fan, OA Damper and squirrel cage induction motor, centrifugal fan belt drive and vibration isolators, Limit switches,Emergency Light , Guard for inspection door. Motors shall be capable of operating through VFD and shall be of EFF 1 efficiency rating , Motor shall be suitable for 415±10% volts, 50 cycles/second, 3 phase AC supply. 12000 CFM with 30mm static
Supply, installation, testing & commissioning of centrifugal STP EXHAUST AIR UNIT suitable for In door installation, Each complete with Forward Curved Centrifugal Fan, OA Damper and squirrel cage induction motor, centrifugal fan belt drive and vibration isolators, Limit switches,Emergency Light , Guard for inspection door. Motors shall be capable of operating through VFD and shall be of EFF 1 efficiency rating , Motor shall be suitable for 415±10% volts, 50 cycles/second, 3 phase AC supply. 9600 CFM with 25mm static
BASEMENT VENTILATION UNITS. Supply, installation testing & commissioning of air of dual speed high temperature rated impulse type induction Axial Jet Fans as per EN12103-2015 standard.Fan casing shall be made of powder coated mild steel and bird screen on both sides.sound attenuators at both side should be 2D length Motor,The jet fans should be fitted with IP 55 motors with standard motor efficiency, The motors are suitable for power supply of 415V, 50Hz, 3 Ph, AC rated for 300 deg. C for 2 hrs, Class 'H' insulation. (same motor to be used as tested & certified as per EN-12101-2015 certification) ,Dual speed TEOA (Totally Enclosed Air Over/Airtight) motor with standard efficiency 4 pole for low speed & 2 pole shall be on high speed. Exact quantity of jet fans shall be finalised after CFD analysis.φ355 - Dual speed Jet Fan - Zone 1
Supply, installation testing & commissioning of air of dual speed high temperature rated impulse type induction Axial Jet Fans as per EN12103-2015 standard.Fan casing shall be made of powder coated mild steel and bird screen on both sides.sound attenuators at both side should be 2D length Motor,The jet fans should be fitted with IP 55 motors with standard motor efficiency, The motors are suitable for power supply of 415V, 50Hz, 3 Ph, AC rated for 300 deg. C for 2 hrs, Class 'H' insulation. (same motor to be used as tested & certified as per EN-12101-2015 certification) ,Dual speed TEOA (Totally Enclosed Air Over/Airtight) motor with standard efficiency 4 pole for low speed & 2 pole shall be on high speed. Exact quantity of jet fans shall be finalised after CFD analysis.φ355 - Dual speed Jet Fan - Zone 2
Supply, installation testing & commissioning of air of dual speed high temperature rated impulse type induction Axial Jet Fans as per EN12103-2015 standard.Fan casing shall be made of powder coated mild steel and bird screen on both sides.sound attenuators at both side should be 2D length Motor,The jet fans should be fitted with IP 55 motors with standard motor efficiency, The motors are suitable for power supply of 415V, 50Hz, 3 Ph, AC rated for 300 deg. C for 2 hrs, Class 'H' insulation. (same motor to be used as tested & certified as per EN-12101-2015 certification) ,Dual speed TEOA (Totally Enclosed Air Over/Airtight) motor with standard efficiency 4 pole for low speed & 2 pole shall be on high speed. Exact quantity of jet fans shall be finalised after CFD analysis.φ355 - Dual speed Jet Fan - Zone 3
Supply, installation testing & commissioning of air of dual speed high temperature rated impulse type induction Axial Jet Fans as per EN12103-2015 standard.Fan casing shall be made of powder coated mild steel and bird screen on both sides.sound attenuators at both side should be 2D length Motor,The jet fans should be fitted with IP 55 motors with standard motor efficiency, The motors are suitable for power supply of 415V, 50Hz, 3 Ph, AC rated for 300 deg. C for 2 hrs, Class 'H' insulation. (same motor to be used as tested & certified as per EN-12101-2015 certification) ,Dual speed TEOA (Totally Enclosed Air Over/Airtight) motor with standard efficiency 4 pole for low speed & 2 pole shall be on high speed. Exact quantity of jet fans shall be finalised after CFD analysis.φ355 - Dual speed Jet Fan - Zone 4
Supply, installation testing & commissioning of AMCA certified for both sound & air Long cased Smoke spill Tube direct driven Axial fan(with VFD), vibration isolaters.The Long casing shall comprise of adjustable blade angles to deliver the design air quantity with Mounting brackets and one side bird screen.The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades),The Motor shall be of TEFC/TEOA, IP-55 protection, Class 'F' insulation, IE-3 motor efficiency, suitable for 3 phase, 3 pole, 415volts, 50hz power supply. 40,000 CFM @ 15mm TSP - Zone 1
Supply, installation testing & commissioning of AMCA certified for both sound & air Long cased Smoke spill Tube direct driven Axial fan(with VFD), vibration isolaters.The Long casing shall comprise of adjustable blade angles to deliver the design air quantity with Mounting brackets and one side bird screen.The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades),The Motor shall be of TEFC/TEOA, IP-55 protection, Class 'F' insulation, IE-3 motor efficiency, suitable for 3 phase, 3 pole, 415volts, 50hz power supply. 42,000 CFM @ 15mm TSP - Zone 2
Supply, installation testing & commissioning of AMCA certified for both sound & air Long cased Smoke spill Tube direct driven Axial fan(with VFD), vibration isolaters.The Long casing shall comprise of adjustable blade angles to deliver the design air quantity with Mounting brackets and one side bird screen.The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades),The Motor shall be of TEFC/TEOA, IP-55 protection, Class 'F' insulation, IE-3 motor efficiency, suitable for 3 phase, 3 pole, 415volts, 50hz power supply. 40,000 CFM @ 15mm TSP - Zone 3
Supply, installation testing & commissioning of AMCA certified for both sound & air Long cased Smoke spill Tube direct driven Axial fan(with VFD), vibration isolaters.The Long casing shall comprise of adjustable blade angles to deliver the design air quantity with Mounting brackets and one side bird screen.The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades),The Motor shall be of TEFC/TEOA, IP-55 protection, Class 'F' insulation, IE-3 motor efficiency, suitable for 3 phase, 3 pole, 415volts, 50hz power supply. 40,000 CFM @ 15mm TSP - Zone 4
Supply, installation testing & commissioning of AMCA certified for both sound & air Long cased Smoke spill Tube direct driven Axial fan(with VFD) & EN certification as per EN12103-2015 standard,The Long casing shall comprise of adjustable blade angles to deliver the design air quantity with Mounting brackets and one side bird screen.The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades).The Motor shall be of TEFC/TEOA, IP-55 protection, 250 Deg C for 2 Hours, Class 'H' insulation, IE-3 motor efficiency, suitable for 3 phase, 3 pole, 415volts, 50hz power supply. (same motor to be used as tested & certified as per EN-12101-2015 certification). 40,000 CFM @ 15mm TSP - Zone 1
Supply, installation testing & commissioning of AMCA certified for both sound & air Long cased Smoke spill Tube direct driven Axial fan(with VFD) & EN certification as per EN12103-2015 standard,The Long casing shall comprise of adjustable blade angles to deliver the design air quantity with Mounting brackets and one side bird screen.The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades).The Motor shall be of TEFC/TEOA, IP-55 protection, 250 Deg C for 2 Hours, Class 'H' insulation, IE-3 motor efficiency, suitable for 3 phase, 3 pole, 415volts, 50hz power supply. (same motor to be used as tested & certified as per EN-12101-2015 certification).42,000 CFM @ 15mm TSP - Zone 2
Supply, installation testing & commissioning of AMCA certified for both sound & air Long cased Smoke spill Tube direct driven Axial fan(with VFD) & EN certification as per EN12103-2015 standard,The Long casing shall comprise of adjustable blade angles to deliver the design air quantity with Mounting brackets and one side bird screen.The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades).The Motor shall be of TEFC/TEOA, IP-55 protection, 250 Deg C for 2 Hours, Class 'H' insulation, IE-3 motor efficiency, suitable for 3 phase, 3 pole, 415volts, 50hz power supply. (same motor to be used as tested & certified as per EN-12101-2015 certification).40,000 CFM @ 15mm TSP - Zone 3
Supply, installation testing & commissioning of AMCA certified for both sound & air Long cased Smoke spill Tube direct driven Axial fan(with VFD) & EN certification as per EN12103-2015 standard,The Long casing shall comprise of adjustable blade angles to deliver the design air quantity with Mounting brackets and one side bird screen.The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades).The Motor shall be of TEFC/TEOA, IP-55 protection, 250 Deg C for 2 Hours, Class 'H' insulation, IE-3 motor efficiency, suitable for 3 phase, 3 pole, 415volts, 50hz power supply. (same motor to be used as tested & certified as per EN-12101-2015 certification).40,000 CFM @ 15mm TSP - Zone 4
Supply, Installation, Testing & Commissioning of CO Gas Detector, for the basement proportional type carbon monoxide (CO) detection. With CO detection in place the ventilation system would run on demand during peak periods when there is highest car park activity. The Co sensor without display. Necessary fixing Box/plate to be considered. Zone - 1
Supply, Installation, Testing & Commissioning of CO Gas Detector, for the basement proportional type carbon monoxide (CO) detection. With CO detection in place the ventilation system would run on demand during peak periods when there is highest car park activity. The Co sensor without display. Necessary fixing Box/plate to be considered. Zone - 2
Supply, Installation, Testing & Commissioning of CO Gas Detector, for the basement proportional type carbon monoxide (CO) detection. With CO detection in place the ventilation system would run on demand during peak periods when there is highest car park activity. The Co sensor without display. Necessary fixing Box/plate to be considered. Zone - 3
Supply, Installation, Testing & Commissioning of CO Gas Detector, for the basement proportional type carbon monoxide (CO) detection. With CO detection in place the ventilation system would run on demand during peak periods when there is highest car park activity. The Co sensor without display. Necessary fixing Box/plate to be considered. Zone - 4
Supply, installation, testing & commissioning of Adapter Connector box from Aluminium power cable to copper power cable for chillers.
POWER WIRING - ALUMINIUM ARMOURED Supply & laying of 1.1 KV grade XLPE insulated Aluminium conductor Armoured. The cost shall also include the end termination of cable with SS gland & lugs.3.5C x 120 Sqmm
ONTROL / COMMUNICATION CABLING - COPPER FLEXIBLE Supply & laying of Copper flexible control cabling. The cost shall also include the end termination of cable with SS gland & lugs. 2C x 1.5 Sq.mm
ONTROL / COMMUNICATION CABLING - COPPER FLEXIBLE Supply & laying of Copper flexible control cabling. The cost shall also include the end termination of cable with SS gland & lugs. 3C x 1.5 Sq.mm
PVC Conduit - 25mm
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray and Hot Dipped Galvanised Iron cable tray cover (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 150 mm wide
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray and Hot Dipped Galvanised Iron cable tray cover (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required350 mm wide
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray and Hot Dipped Galvanised Iron cable tray cover (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 100 mm wide
Supply, installation & Laying of Earthing conductor 25 * 6 GI Flat
Supply, installation & Laying of Earthing conductor 25 * 3 GI Flat
Supply, installation & Laying of Earthing conductor 8 SWG GI wire
Supply & installation of DPT Control / Communication cabling - Cu Unarmoured 4Cx1.5 Sqmm with PVC Conduit
Supply & laying of 1.1 KV grade XLPE insulated Copper conductor Armoured. The cost shall also include the end termination of cable with SS gland & lugs. 3C x 10 Sqmm
Supply & laying of 1.1 KV grade XLPE insulated Copper conductor Armoured. The cost shall also include the end termination of cable with SS gland & lugs.3C x 6.0 Sqmm
Supply & laying of 1.1 KV grade XLPE insulated Copper conductor Armoured. The cost shall also include the end termination of cable with SS gland & lugs. 3C x 2.5 Sqmm
Supply & laying of Copper flexible control cabling. The cost shall also include the end termination of cable with SS gland & lugs.2C x 1.5 Sq.mm
Supply & laying of Copper flexible control cabling. The cost shall also include the end termination of cable with SS gland & lugs.3C x 1.5 Sq.mm
Supply & laying of 1.1 KV grade XLPE insulated power & control cabling. The cost shall also include the end termination of cable with SS gland & lugs. 6C x 1.5 Sq.mm Copper Armoured FRLS Cable (From Jet fans to PLC Panel)
Supply & laying of 1.1 KV grade XLPE insulated power & control cabling. The cost shall also include the end termination of cable with SS gland & lugs.3C x 6.0 Sqmm Copper Armoured FRLS Cable (7.5 KW to 11KW From Axial fans to PLC Panel)
Supply & laying of 1.1 KV grade XLPE insulated power & control cabling. The cost shall also include the end termination of cable with SS gland & lugs. 4C X 1.0 Sqmm Copper Armoured FRLS Cable with conduit (From CO Sensors to PLC Panel)
Supply and installation of GI Ladder type cable trays with 1.6mm thick x 50mm Height without cover along with bolts, nuts and other accessories. 600mm
Supply and installation of GI Ladder type cable trays with 1.6mm thick x 50mm Height without cover along with bolts, nuts and other accessories. 500mm
Supply and installation of GI Ladder type cable trays with 1.6mm thick x 50mm Height without cover along with bolts, nuts and other accessories. 450mm
Supply and installation of GI Ladder type cable trays with 1.6mm thick x 50mm Height without cover along with bolts, nuts and other accessories.300mm
Supply and installation of GI Ladder type cable trays with 1.6mm thick x 50mm Height without cover along with bolts, nuts and other accessories. 250mm
Supply and installation of GI Ladder type cable trays with 1.6mm thick x 50mm Height without cover along with bolts, nuts and other accessories. 200mm
BMS-CENTRAL SERVER, WORKSTATION AND NETWORK COMPONENTS.Server: Intel Xeon Quadcore Processor, DDR4 RAM - 32GB (Expandable up to 64 GB), Intel Chipset Mother Board, SATA HDD shall support maximum upto 8bay with 32TB internal storage, the server shall come with RAID 1 / 5 controller with a usable space of up to 2TB [i.e. 2TB X 2Nos. under RAID 1 configuration], shall support the following minimum I/O ports configuration, 4Nos USB 3.0, VGA Card, 2 x 10Gb ethernet adaptor, 1No micro USB, etc. Redundant power supply of 750W / as per the server configuration. The server shall come with tower form factor, Optical Mouse and Multimedia Keyboard, 21” LED monitor.
Server OS : Shall be Microsoft Windows Server 2012 / 2016 / latest.
Server Data base: Microsoft SQL Server 2014 / 2016 / latest.
BMS Client Work Station: Intel Core i7 Processor > 2GHz, DDR RAM - 16GB (Expandable up to 32 GB), Intel Chipset Mother Board, SATA HDD shall support maximum upto 8TB internal storage, with a usable space of 1TB, shall support the following minimum I/O ports configuration, 2Nos USB 3.0, VGA Card, HDMI, 1Nos 1Gb ethernet adaptor, etc. Power supply of 300W / as per the workstation configuration. The workstation shall come with tower form factor, Optical Mouse and Multimedia Keyboard. The workstation shall include 2GB NVIDIA graphic card supporting minimum of 2nos of monitors of HD resolution. Windows10 OS or baove shall be preloaded in the workstation
Antivirus Software and MS Office Business edtion
42" LED Monitor
A3 size colour Inkjet Printer suitable for the application, with driver software.
NETWORK 24 port non POE Managed Network Switch with 2 SFP ports
NETWORK 24 port non POE semi managed Network Switch with 2 SFP ports
NETWORK 24 port loaded patch panel with provision for fiber connectivity
NETWORK 9U Wall mount rack to mount the Network switch
CAT6-OFC-CAT6 Media converter
Fiber termination with required accessories
BMS Software, energy management software and tenant Billing Software: BMS software shall be Web Based Graphical interface software based on MS Server / Windows 10 / Latest. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses or Software. The Communication protocol with the DDC, 3 Party Systems, etc. shall be Industry Standard open platform of BACNET / OPC / API [Vendor to specify if API is applicable]. System shall include Unlimited data points. Software shall work in the WEB environment supporting HTML5 with min 5 concurrent client users license on LAN / WEB. The software shall support system generated alarms with statistics of alarm types, notification via email, SMS, etc. Software shall be certified and complying to BACnet Advanced Operator Workstation standard ISO 16484-5 protocol version 1.13 or latest. BMS software shall include Supervisory Controller for connecting the Software ( PC ) to the DDC Controllers if required for the vendor Energy Management Software shall be part of proposed BMS software – The software shall display both real time and historical values. Displays in various views including Calendar, graphical and tabular, Line, Pie chart and bar chart. Based on the meter values hourly, daily, weekly and monthly consumption values shall be calculated and displayed. The software shall have facility to define alarms for certain consumption values. There shall be a comparative chart for definable periods for Energy analytics. Defined users shall be able to view the details through Desktop, Mobile or Ipad with auto adjust views based on the type of the device. Environmental index for comfort dashboard should be part of this software. Tenant Billing Software for generation of BTU & energy bills as per client requirements. Required licences for running 3 PC including the server shall be considered
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 1 -3 : for AHU as per I/O summary.
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 4 to 58: for CSU's as per I/O summary.
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 59: for Staircase Pressurization Fans as per I/O summary
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 60: for Ventilation Fans (Basement ) as per I/O summary
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 61: for Ventilation Fans (Ground Floor) as per I/O summary
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 62: for Ventilation Fans (Terrace Floor) as per I/O summary
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 63: for PHE as per I/O summary
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 64: for Fire Pumps (Terrace) as per I/O summary
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 65: for Fire Fighting Pumps as per I/O summary
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No. 66: for STP as per I/O summary.
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No 67: for HT/LT Breakers as per I/O summary.
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No 68: for Lifts as per I/O summary.
DDC CONTROLLERS : DDC Controller with I/O module etc., The controllers shall only be NATIVE BACNET/IP based complying to BACnet standard ISO 16484-5 protocol version 1.13 or latest. The controller shall be with microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The DDC's shall store programs and program parameters in non-volatile memory of 16GB. All DDC Controllers with necessary enclosure panels shall be provided with hinged doors with locking facility and back plate. 25% excess ports shall be considered for Each DDC Requirement as per the Lot DDC No 69: for Chiller Plant as per I/O summary.
Required Gateway / Open Protocol Software for integrating the following third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, etc The Integratos shall store programs and program parameters in Flash memory of minimum 16GB - Vendor to considered required No. of Integrators for qty's mentioned in IO summary Chillers Chiller plant VFD's Energy Meters DG Set UPS/Inv Fire Detection and Alarm System PA System Lifts/Elevators STP Integration (Sewage Treatment system) WTP PLC Integartion Basement Ventilation PLC Integration BTU Meter ( Tenant Billing ) Flow Meter (For Water Intake to the Tanks) Transformer
Supplying, installing, testing and commissioning of air flow switch to monitor the fan status as per Technical Specifications
Supplying, installing, testing and commissioning of differential pressure switch to monitor the filter status. As per Technical Specifications'
Supplying, installing, testing and commissioning of duct type temperature sensor with all mounting accessories to measure the supply air temperature. (Measuring Range : 0 - 50 Deg C)
Supplying, installing, testing and commissioning of duct type temperature & RH Sensor with all mounting accessories to measure the supply air temperature & RH. (Measuring Range : 0 - 50 Deg C)
Supplying, installing, testing and commissioning of Immersion type Temperature Sensor to measure Return & Supply CHW Temperature with all mounting accessories
Supplying, installing, testing and commissioning of duct CO2 Sensor with a measuring range of 0-2000ppm. It shall be UL/FM Listed /Approved
Supplying, installing, testing and commissioning of duct Static Pressure Sensor with all mounting accessories
Supplying, installing, testing and commissioning of outside temperature, RH and CO2 sensor with radiation shield suitable to mount in outdoor It shall be UL/FM Listed /Apprved
Supplying, installing, testing and commissioning of float type Level Switch for water tanks - 3 mtr height Note: Installation and supply of accessories for installation shall be done by the Plumbing contractor It shall be UL/FM Listed /Apprved
Supplying, installing, testing and commissioning of float Type Flameproof Level Sensor for diesel tanks - 3 mtr height Note: Installation and supply of accessories for installation shall be done by the DG contractor It shall be UL/FM Listed /Approved
Supplying, installing, testing and commissioning of water DP transmitter with all mounting accessories
Supplying, installing, testing and commissioning of water DP switch with all mounting accessories
Supplying, installing, testing and commissioning of float type flameproof level switch for DG tanks - 3 mtr height, It shall be UL/FM Listed /Approved. Note: Installation and supply of accessories for installation shall be done by the HSD contractor
Supplying, laying, termination, testing and commissioning of 2 core 1.0 mm2 unarmoured, PVC insulated, tinned copper conductor cable- unscreened
Supplying, laying, termination, testing and commissioning of 2 core 1.0 mm2 unarmoured, PVC insulated, tinned copper conductor cable-screened
Supplying, laying, termination, testing and commissioning of 4 Core 1.0 sq. mm, unarmored, PVC insulated, tinned copper conductor cables - screened
Supplying, laying, termination, testing and commissioning of 2C X 1.5 Sq.mm twisted pair shielded cable for bus connection- for Integration
Supplying, laying, termination, testing and commissioning of CAT 6 UTP cable for bus connection - for IP Devices
Supply and providing PVC-FRLS 3/4 " PVC Conduit complete with all fittings and accessories
Supply and providing PVC-FRLS 1 " PVC Conduit complete with all fittings and accessories
Supplying, laying and fixing of GI conduits of 25mm dia complete with all accessories.
Supply and providing of GI Perforated cable tray without cover complete with all fittings and accessories300mmx50mmx 1.6mm
Supply and providing of GI Perforated cable tray without cover complete with all fittings and accessories200mmX50mmX1.6mm
Supply and providing of GI Perforated cable tray without cover complete with all fittings and accessories 100mmX50mmX1.6mm
Cable Tray Angles, Thread rods and supports
KBR Infratech Limited
P & C PROJECTS PRIVATE LIMITED
sri Avantika Contractors (I) limited
MARYMATHA INFRASTRUCTURE PVT LTD
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
P & C PROJECTS PRIVATE LIMITED
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
sri Avantika Contractors (I) limited
MARYMATHA INFRASTRUCTURE PVT LTD
Bridge And Roof Co. (I) Ltd.
sri Avantika Contractors (I) limited
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
Bridge And Roof Co. (I) Ltd.
P & C PROJECTS PRIVATE LIMITED
MARYMATHA INFRASTRUCTURE PVT LTD
sri Avantika Contractors (I) limited
MARYMATHA INFRASTRUCTURE PVT LTD
Bridge And Roof Co. (I) Ltd.
P & C PROJECTS PRIVATE LIMITED
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
sri Avantika Contractors (I) limited
Bridge And Roof Co. (I) Ltd.
P & C PROJECTS PRIVATE LIMITED
MARYMATHA INFRASTRUCTURE PVT LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid