Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.1 LAccepted-AOC HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹78.0 L+₹7.9 L (11.3%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance Other then lowest bidder | |
| 3 | L3₹85.9 L+₹15.9 L (22.7%)Rejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA 390 002 | VADODARA | VADODARA | GUJARAT | 390002 | L3 | Rejected-Finance Other then lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Your firm is two class below and do not satisfy elgibility criteria as per NIT. Hence, rejected. |
Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
7 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Manish Dhaka
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
PROVN OF ADDL ROOM FOR BULK STORAGE AT AF STN HARNI BARODA
2023_MES_627435_2
82162/BRD/E8
Open Tender
Construction Works
Lump-sum
333 days
Baorda
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE (AF) Baroda
₹1.2 L
2 Apr 2024
8 Feb 2024
14 Mar 2024
8 Feb 2024
7 Mar 2024
22 Feb 2024
9 Feb 2024 - 12 Feb 2024
Amount
NOTE: Schedule ‘A’ Part I to XI under Ser No. 1 to 10 here in after are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for BUILDING/ STRUCTURES as listed in Sch 'A’ Part I.
Lump sum price worked out for EXCAVATION & EARTH WORK as listed in Sch 'A’ Part II.
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A’ Part III.
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A’ Part IV.
Lump sum price worked out for ROAD/PATH as listed in Sch 'A’ Part V.
Lump sum price worked out for FENCING as listed in Sch 'A’ Part VI.
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A’ Part VII.
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part VIII.
Lump sum price worked out for LIGHTNING ARRESTER as listed in Sch 'A’ Part IX
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A’ Part X
SCHEDULE `A' PART-XI (MISCELLANEOUS ITEMS) (Note for following items- The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
INTERNAL ELECTRIFICATION
S&F Flame proof Tube light fitting 2 x 20 Watt flame proof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size 4 feet complete all as specified and directed.
S&F Flame proof weather proof sheet metal enclosure single door SPN DB 4 way in cast aluminium alloy LM6 construction comprising of following: - (a) MCB SPN 40 Amps 10KA, 240V-1 No (b) MCB SP 10 Amp 6 KA, 240 V- 2 Nos
S&F Flame proof exhaust fan 300 mm sweep with louvers ,0.25 HP single phase 230 volts 1440 RPM, CFM 1120 ISI marked all as specified and directed.
S&F Flame proof ceiling fan 1200 mm sweep single phase 230 volts 1440 RPM ISI marked. all as specified and directed.
FENCING
S&F Concertina coil with electro galvanised steel strip 0.5mm ± 0.02mm thick, width 19mm (before wrapping on central core wire) conforming to IS-1573, zinc coating-120gm / sqm and bituminous dipped, width of barbs 11.5mm, pitch of barbs 25.4mm ±0.20mm of 2 mm thick, and central core wire – made from high tensile spring steel core wire conforming to IS-4454 duly hot dipped galvanised( conforming to IS-2629) with dia 2.59mm ± 0.05mm, UTS 145-160Kg/sqmm, Zinc coating 250-300 gm/Sqm with 600 mm dia coil fixed with AISI 304-15mm thick C&U clips ’C’ special type of coil and RBT wire ”U” clips special type for joining one coil to another coil and RBT wire to RBT wire joining all as specified
LIGHTNING ARRESTER
S&F Insulating clamp on the wall/ roof for fixing of copper strip complete all as specified and directed.
REROUTING OF AFNET CABLE
Supply and laying in trenches 48 core single mode 9/125 micron,48 fibre, armoured cable, mode field diameter 1550 nm(+10%), Cladding diameter -125micro meter (+2 micrometer), mode field connectivity Error-1550 nm region below0.35dB/KM, G0655 for 1550 nm wavelength OFC with specification as per ITU-T recommendation OFC armoured cable as approved by GE
Supply and laying in trenches 24 core single mode 9/125 micron,48 fibre, armoured cable, mode field diameter 1550 nm(+10%), Cladding diameter -125micro meter (+2 micrometer), mode field connectivity Error-1550 nm (not exceeding 1micrometer) alteration coefficient-1550 nm region below0.35dB/KM, G0655 for 1550 nm wavelength OFC with specification as per ITU-T recommendation OFC armoured cable as approved by GE
Notes for serial item No 15.01 & 15.02 (a). Cable will be laid in HDPE pipe through Horizontal direction drilling upto the depth 10 feet ( 03 m). HDD will be measured and paid separately (b). Wherever HDD is not possible (i) Cable will be laid in a trench of 1.65 m to 03 m deep as per BSNL standard and specifications inside HDPE pipe. Whenever required for turns, bridges, culverts etc HDPE/rigid PVC pipes/GI pipes will be used for protection. Note :- Earth work and returning and filling will be measured and paid separately. (ii)The depth of trenching must ensure rodent protection. The responsibility for ensuring this shall be that of contractor. (iii) Width at top should be minimum 450mm but can be more as per soil condition and actual depth from road surface as to meet the working condition. (iv) Minimum 8 bricks will be laid per meter length of HDPE. Brick size will be minimum 200mm each
(v) In case it is not possible to dig upto 1.65m (rocky area, near culverts/bridges), GI Pipes should be used. If the thickness of the cushion on top of OFC is less (after filling trench), appx 75mm thick RCC (1.24) on sides and top can be used. (vi) Proper jointing Kit shall be used by the contractor to join the OFC wherever necessary. (vii) Road Crossing: The road crossing in the route while laying the cable to be laid inside GI pipe Note:- The same will be measured and paid separately under respective item
Supply and lay HDPE pipe pre lubricated with rope 40 mm dia, wall thickness-3.5 mm, co-efficient of friction less than 0.1, blowing pressure upto 10 bar, environmental stress crack-as per ATSMD1693, crush resistance test- as per TEC specification No G/CDS-01/01Dec 1994 and amendment no 1,internal pressure creep test-48 hrs at 80 degree celsius, impact resistance test-no crack or split as per IS-12295 (part9)-1986, reversion test-less than 3% as per IS 4984-1995 as approved by GE
M&L Fibre jointing kit with enclosure complete as approved by GE
S&F 50 pair x 0.5 mm dia jelly field unarmoured telephone cable as per ITD specification - solid polythene insulated jelly field polythene sheathed underground telecom cable (JFC unarmoured cable), conductor dia 0.5 mm, conductor resistance (Ohm/KM) 86+/- 6, Individual 2.5, Average-1, Conductor Elongation (minimum %)-15, Max Attenuation at 150 Khz(db/km)-8.25 db, insulation-solid (HDPE/MDPE), resistance to compression-200 N, 12 V DC, insulation resistance at 500 V 5000 mega ohm-KM, Moister Barrier - poly aluminium, core wrap- polyester tape, far End crosstalk (db) at 150 Khz- better than 67.8 RMS (individual value), near End crosstalk (db) at 150 Khz- better than 55 RMS (individual value) as approved by GE
Note: - Laying of JFC: (a). Cable will be laid in HDPE pipe through Horizontal direction drilling upto the depth 10 feet (03 m). HDD will be measured and paid separately (b). Wherever HDD is not possible : (i) Cable will be laid in a trench of one-foot-wide and 3.5 feet deep after filling six-inch sand in the trench, 6-inch sand will be put above the cable also. Then, as per requirement a layer brick width wise (8 standard bricks per mtr) will be placed on top of the sand on the cable before closing the trench. The minimum length of any of the above cable protection covering (RCC pipe/brick/ grade one brick) will be 500 mtrs. In case more than one cable is passed through same trench then the one cable is passed through same trench then the bricks will be laid breadth wise ( 08 standard bricks per mtr ) Road Crossing: (ii) The road crossing in the route while laying the cable to be laid inside GI pipe.
S&F JFC termination kit complete as approved by GE
M&L Route marker standard stone RCC mile stone shape painted orange engraved with letter AF NET OFC and painted using black enamel paint as approved by GE Note : Cable route markers are to be provided at a distance of every 100 mtr. The cable route marker shall be five feet long with six inches dia metal disc at one end and fixed on a concrete block to prevent any unintentional shifting. The marker will be 1.5 feet above ground. The disc will have following marking engraved (a) AFNET OFC (b) Route (c) Date of Installation
M & L Construction of brick masonry chamber of inner dimensions 1m x 1m x 1.8 m suitable with precast RCC manhole cover 100 mm thick, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering in CM 1:4 15 mm thick mixed with water proofing compound, coping in PCC 1:2:4 type B1, including necessary earth work, form work complete all as specified and directed by Engineer-in-charge.
M&L Horizontal directional drilling with trenchless technology including pilot drilling, reaming and pipe pull back in any type of soil/rock strata at depth of 10 feet (03 m) for installing of 40mm dia HDPE pipe and pull back of communication cable complete all as directed by Engineer-In-Charge and as per standard practice of BSNL. Note: - HDPE pipe and communication cable shall be measured and paid seperately under respective item
Supply and lay sub class B Grade bricks directed by Engineer-In-Charge
Supply and lay pipe galvanized,medium grade including fittings 40 mm bore all as directed by Engineer-In-Charge
VIJAY CONSTRUCTION CO
City Light
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .