Loading…
Loading…
Tender Value
₹30 L
EMD Value
₹30,000
Closing Date
29 Sept 2026, 4:00 pm2d left
Executive Engineer (O&M), DGVCL Bharuch Rural Division
Annual Rate contract for Erection and Maintenance work of HT/LT Line and TC Structure and Laying, Testing & Commissioning of 11/22KV underground XLPE cable with cable end termination & straight though jointing kits Work Under ND and Other Scheme Under Jambusar Town Sub Division Only under Bharuch Rural Division.
347507
BRH-2026-27-102
Open
Electrical and Maintenance Works
Works
Bharuch
1 document required · 1 mandatory
₹2,360
Executive Engineer DGVCL, Bharuch
₹30,000
22 Sept 2026
22 Sept 2026
22 Sept 2026
29 Sept 2026
22 Sept 2026
Labour rates for Annual Rate contract for Erection and Maintenance work of HT/LT Line and TC Structure
and Laying, Testing & Commissioning of 11/22KV underground XLPE cable with cable end termination &
straight though jointing kits Work under various scheme under Jambusar Town Sub Division Only
under Bharuch Rural Division.
::DGVCL Circular of Revised SOR rates for the year 2024-25::
1) Letter No: DGCS/1408/01/2025 Approved Date: 27-01-2025, 2) Letter No: DGCS/1411/01/2025 Approved
Date: 27-01-2025 3) Letter No: DGCS/1408/01/2025 Approved Date: 27-01-2025
The Labour rates are excluding of GST.
(A). CAPITAL WORK LABOUR RATES
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF
CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD,
INSULATORS ETC. COMPLETE AND PAINTING OF FABRICATED
MATERIALS AND NUMBERING COMPLETE WITH COST OF PAINTS
AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING EXCAVATION
OF PIT AND REFILLING OF EARTH, FIXING OFCROSS ARMS, TOP
FITTING CLAMPS ANTI-CLIMBING DEVICES, INSULATORS ETC.
2 9926000002 COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON No.
THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.
ERECTION OF STEEL POLES OF 9 TO 11 METERS INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OFCROSS
ARMS, TOP FITTING CLAMPS ANTI- CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF STEEL
POLE, FABRICATED MATERIALS USED ON THE POLEAND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY CROSSING
ON BG/MG/NG LINE FOR 0.400/11/22KV OVERHEAD LINES I.E
INCLUDING EXCAVATION OF PIT & REFILLING OF EARTH, FIXING
CROSS ARMS, TOP FITTING CLAMPS, ANTI-CLIMBING DEVICES
4 9926000004 DANGER BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF No.
STEEL POLES, FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS 200 KG PSC
POLES INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS, SUPPORTING ANGLES,CLAMPS,
ANTI-CLIMBING DEVICES DANGER BOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO
11 METERS.STEEL POLE INCLUDING EXCAVATION OF PITS &
REFILLING OFEARTH, FIXING OF CHANNELS, SUPPORTING
ANGLES, CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARDS,
INSULATORS ETC.COMPLETE & PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND NUMBERING WITH COST OF
PAINTSAS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB
SWITCH, HG FUSES OF 8 MTRS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF EARTH,FIXING OF
CHANNELS SUPPORTING ANGLES, CLAMPS, ANTI- CLIMBING
7 9926000007 DEVICES, DANGER BOARDS, INSULATORS,DOFUSES ETC. No.
COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDINGOF ERECTION OF GUY
SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB
SWITCH,HG FUSES, 9 TO 11 METERS STEEL POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF EARTH, FIXING
OFCHANNEL, SUPPORTING ANGLES, CLAMPS, ANTI- CLIMBING
8 9926000008 DEVICES , DANGER BOARDS, INSULATORS, ETC. COMPLETE AND No.
PAINTING OF POLES FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OFAB
SWITCH, HG FUSES, TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 8 METER, 200KG PSC POLE METERS POLES
INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH,
CARTING OF TRANSFORMERS FROMSTORES TO SITE, FIXING OF
9 9926000009 CHANNELS, SUPPORTING ANGLES, BRACINGS CROSS ARMS No.
CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR
AND CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USEDON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB
SWITCH,HG FUSES TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS STEEL POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE, FIXINGOF CHANNELS
10 9926000010 SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, No.
ANTICLIMBING DEVICES, DANGER BOARDS,CONDUCTOR AND
CABLE WIRING ETC. COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING
AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTIONS
OF GUY SETS AND EARTHING.
ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTH AS PER STANDARD SPECIFICATION WITH
11 9926000011 STAY CLAMPS, STAY WIRE, ANCHOR ROD, TURN BUCKLE, No.
EYEBOLT, GUY INSULATOR, CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF CEMENT
12 9926000012 SAND METAL (1:2:4) AND WATER ETC. AS PER STANDARD CMT
SPECIFICATION.(cement Should be 53 grade) used for Concreting.
ERECTION OF COIL TYPE EARTHING INCLUDING COST OF
13 9926000013 COAL,SALT ETC. BUT WITHOUT COST OF GI WIRE AS PER No.
STANDARD SPECIFICATION(20kg solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING INCLUDINGCOST
14 9926000014 OF COAL SALT ETC. BUT WITHOUT COST OF PIPE/GIPLATE GI No.
WIRE AS PER STANDARD SPECIFICATION.(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH CLAMPS,
BRASS NIPPLE, BRASS HOLDER TECK WOOD BUSH,REFLECTORS
FUSE, WIRING ETC. AS PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA CONDUCTOR ONE
16 9926000016 for ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR COND
11/22KV & LT LINES INCLUDING FIXING OF INSULATORS, BINDING PER KM
STRINGING OF GI WIRE 8 SWG INCLUDING BINDING JUMPERING
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC
2.5/4MM2 TWIN CORE CABLE FROM TERMINAL POLE TO
18 9926000018 METERING POINT INCLUDING FIXING OF METER WITH METER No.
EARTHING COMPLETE WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION WITH
PVC 4MM2/10MM2 FOUR CORE CABLE FROM TERMINAL POLE TO
19 9926000019 METERING POINT INCLUDING FIXING OF METER WITH METER No.
EARTHING COMPLETE WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA
FOR ERECTION OF POLE/ GUY ETC. AS PER STANDARD
SPECIFICATION OVER & ABOVE NORMAL COST COVERED AGAINST
EXCAVATION OF PIT UNDER NORMAL SOIL FOR ERECTION OF
POLE, GUY, DOUBLE POLE STRUCTURE EARTHING WITH THE
APPROVAL OF SUPDT.ENGINEER.
21 9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL CROSSING. MTR
22 9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL CROSSING. MTR
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD
25 9926000025 CROSSING,HT LINE CROSSING AND TELEPHONE LINE CROSSING No.
ERECTION OF SINGLE POLE STRUCTURES WITH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTOR, DISTRIBUTION BOX. ON
8 METERS 200 KGAND PSC POLE INCLUDING EXCAVATION OF PITS
AND REFILLING OF EARTH, CARTING OF TRANSFORMERS FROM
STORES TO SITE, FIXING OF CHANNELS, SUPPORTING ANGLES,
26 9926000026 BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER No.
BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE POLE AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS AND
ERECTION OF SINGLE POLE STRUCTURES WITH MOUNTING OFAB
SWITCH , HG FUSES,
TRANSFORMERS, LIGHTENINGARRESTOR, DISTRIBUTION
BOX. ON 9 to 11 METERS RSJ POLE INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROM STORES TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES, BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED
ON THE POLE AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OFGUY SETS AND EARTHING.
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING EXCAVATION
OF PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP
FITTING CLAMPS ANTI-CLIMBING DEVICES, INSULATORS ETC.
28 9926000028 COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON No.
THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 10 METERS 270 KG
PSC POLES INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS, SUPPORTING ANGLES,CLAMPS,
ANTI-CLIMBING DEVICES DANGER BOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR FOR ONE
30 9926000030 11/22KV & LT LINES INCLUDING FIXING OFINSULATORS, BINDING COND
JUMPERING ETC. PER KM
STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT LINES
INCLUDING FIXING OF INSULATORS, BINDING JUMPERING ETC.
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OF
AB SWITCH, HG FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF 10 METERS 270 KGAND PSC
POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING ANGLES, BRACINGS CROSS
ARMS CLAMPS, ANTI-CLIMBING DEVICES, DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING
OF FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF
33 9926000033 FABRICATION AT STORE & STACKING OF POLE SAFELY ON ROAD No.
SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF
34 9926000034 FABRICATION AT STORE & STACKING OF POLE SAFELY ON ROAD No.
SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE)
(WITH TRANSFORMER) WITH CREDITING OF FABRICATION &
TRANSFORMER AT STORE & STACKING OF POLE SAFELY ON ROAD
SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE)
(WITHOUT TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE & STACKING OF POLE SAFELY ON ROAD
SIDE OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE INSULATOR
37 9926000037 ETC. FOR FIXING OF MESSENGER WIRE AND TO PROVIDE KM
SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND
TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE.
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
39 9926000039 TENSION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN KM
INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
40 9926000040 TENSION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN KM
INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS
REQUIRED AND DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND
TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING THE
OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC
POLE(WITHOUT TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC
POLE(WITH TRANSFORMER) WITH CREDITING OF FABRICATION
AT STORE AND STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND
45 9926000045 CREDITING FITTING OF ALL ACESSARIES AND FABRICATION KM
TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND
46 9926000046 CREDITING FITTING OF ALL ACESSARIES AND KM
FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND
47 9926000047 CREDITING FITTING OF ALL ACESSARIES TO DEPARTMENTAL KM
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ
48 9926000048 MM AND CREDITING FITTING OF ALL ACESSARIES TO KM
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ
49 9926000049 MM AND CREDITING FITTING OF ALL ACESSARIES TO KM
DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG ONE
50 9926000050 CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING OF COND
INSULATORS, BINDING JUMPERING ETC. PER KM
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES
INCLUDING , BINDING JUMPERING ETC.
LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR METER.
(METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER AND
53 9926000053 OLD METER SHOULD BE CREDITED TO SDN STORE. (METER WILL No.
BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER
CONNECTION. (CT COIL WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR METER
55 9926000055 CONNECTION AND OLD CT SHOULD BE CREDITED TO SDN PER CT
STORE. (CT COIL WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR DTR
METER (MMB WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF DTR METER
BOX. (METER WILL BE PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER
CABLE 3.5 METER (CABLE TO BE PROVIDED BY AGENCY)
LABOUR CHARGE FOR PROVIDING/RECONNECTION OF TERMINAL PER
59 9926000059 CONNECTION WITH PROPER SIZE OF LUGS. (LUGS COST IS BORNE TERMINA
BY AGENCY) TION
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH
DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN COPY BY
SURVEYOR PERSON OF AGENCY IN PRO- FORMA REPORT SHOULD
BE SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PARAMETER OF
VOLTAGE, CURRENT & LOAD AS SHOWN IN PER-FORMA IS FILLED)
AS PER THE INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH
DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN COPY BY
SURVEYOR PERSON OF AGENCY IN PRO- FORMA REPORT SHOULD
BE SUBMITTED TO SDN OFFICE. (DULY FILL PER-FORMA IN FAULT
CONDITION IN WHICH READING PARAMETER IS NOT SHOWN IN
INSTALLATION OF DTR METER INCLUDING METER BOX,
PROVIDING & FIXING OF 1.5SQ MM SINGLE STRAND 10 CORE
62 9926000062 ARMOURED COPPER CABLE (3.5METER), TERMINATION IN METER No.
& COIL ETC.(METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING METER BOX,
TERMINATION IN METER & COIL ETC. (WITHOUT 10CORE COPPER
CABLE) (METER, METER BOX, C.T./P.T. COIL WILL BE PROVIDED BY
Binding of messenger Conductor at with a distance not more than
64 9926000064 0.75 mtr with 6 turns minimum on XLPE Cable with single strand No
binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution Transformers HT
65 9926000086 Terminal protector (UV Resistance) with using 95/120/150 sq.mm PER SET
long barrel aluminium lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV Distribution
Transformer with replacement of bare conductor by HT ABC
66 9926000087 conductor (DO bottom side to transformer) after removal of PER SET
semiconductor by HT ABC (6 inch both side). HT ABC to be supplied
by DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of Maintenance
Free, Ready Capsule, Pipe-In- Cage (Pic) Type, Earth Electrodes for
67 9926000088 HT Feeder Pole Having 2000 mm Electrode Length as per the NO
Tender Specifications and Drawing. (All Materials Will Be Supplied
Supply, Installation, Testing and Commissioning of Maintenance
Free, Ready Capsule, Pipe-In- Cage (Pic) Type, Earth Electrodes for
68 9926000089 HT Feeder Pole Having 3000 mm Electrode Length as per the NO
Tender Specifications And Drawing. (All Materials Will Be Supplied
Supply and Installation of 25 X 3 mm GI Strip having hot dip-
galvanized-zinc coating of 80-100 microns without any joints or
welding. Both the end of the GI strip should be connected with GI nut
bolts and required fabrication work for giving separate earthing
(1) Neutral of the transformer
(2) MS structures of the transformer centre (Approximately
meter GI strip per transformer centre
- as per requirement and instruction of Engineer in-
charge) (All Materials will be supplied by Agency)
Supply and Installation of uPVC standard make Pipe of 1.25"
diameter for covering GI strip with UV protected Cable Ties of 550 X
70 9926000092 7.6 mm size to bind with pole face(Approximately 25 meter uPVC Meter
pipe for GI strip covering per transformer centre -as per
requirement and instruction of Engineer in-charge.
Supply & fixing of up to 33 kV Conductor sleeve for Busbar to Drop
out Fuse and Drop out fuse to Transformer H.T. including Busbar
(12 mm sleeve) as per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Drop
out Fuse and Dropout fuse to Transformer H.T. without Busbar (12
mm sleeve) as per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of up to 33 kV Conductor sleeve for Busbar to Drop
out Fuse and Drop out fuse to Transformer H.T. including Busbar(15
mm sleeve) as per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Drop
out Fuse and Drop out fuse to Transformer H.T. without Busbar(15
mm sleeve) as per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of Disc type Red Colour FRP(Non-flammable)
material with Weather resistant, Non-conductive bird guard
OD=300 MM, ID=33 MM, Width =1.25 MM, one side cut from ID to
OD. (All Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e. Re-useable boot
76 9926000096 (LT Side 1.1 kV) including LT (1.1 kV) insulating taps. All live part at No
LT side shall be covered with fixing of LT insulating taps.
Nylon Net around Transformer Centre
77 9926000097 Nylon Net (12 * 15 ft) Per Net
78 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated material for
fitting nylon net shall be provided by DGVCL)
(B) LINE MAINTENANCE
80 9924000001 Cutting of Tree branches surrounding HT/LT line Per Tree
Replacement of old jumpers & providing new double jumpers with
8" binding [D Type] & capsuling with PVC pipe etc
82 9924000005 Support pole for Stay PSC/STP/RSJ No.
83 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator per pole in coastal
area with cleaning.
85 9924000008 Pin binding of conductor LT shackle insulator No.
86 9924000009 Replacement of one/both disc. insulator at strain pole No.
87 9924000010 Replacement of LT shackle insulator at cut point No.
88 9924000011 Refixing of V cross Arm No.
89 9924000012 Replacement of V cross Arm (With Transportation & Painting) No.
90 9924000013 Refixing of Top fitting in proper position No.
91 9924000014 Replacement of Top fitting No.
92 9924000015 Replacement of LT cross Arm No.
93 9924000016 Providing DO fuse on DP with carting & jumpering (ONE DO FUSE) No.
Numbering of pole with paint by preparing back ground of one
colour and have lettering(height 3" * width 0.5") using stencil
95 9924000018 Fixing of MMB(1PH.) at consumer end No.
96 9924000019 Fixing of MMB(3PH.) at consumer end No.
97 9924000020 Replacement of (1ph.) meter for Urban area No.
98 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with letter size height
40mm* width 8mm)
painting consumer no. on MMB (Rural) (with letter size height
40mm* width 8mm)
101 9924000024 Replacement of deteriorated Single phase Service line No.
Fixing of new dist. Box with complete wiring including clamps, nut
Repairing of guarding involving reshaping of bearer wire cross
lacing binding etc.
Painting of steel fabricated material of RSJ DO DP structure with
Painting of steel fabricated material of RSJ pole mounted
transformer double pole structure with paint
106 9924000029 Painting of steel fabricated material of RSJ single pole with paint No.
painting of steel fabricated material of PSC Single pole (HT line)
painting of steel fabricated material of PSC DO DP double pole with
painting of steel fabricated material of PSC double pole at pole
mounted transformer with paint
110 9924000033 Providing line separator single phase No.
111 9924000034 Providing line separator three phase No.
Replacement / Providing of stay insulator along with adjustment of
tension in stay wire
Replacement of deteriorated /providing LT dist. Box with new up to
100KVA capacity & crediting it to store.
Replacement of deteriorated/providing LT dist. Box with new above
100KVA capacity & crediting it to store.
115 9924000038 Adjustment of tension in stay wire No.
116 9924000039 Refitting of LA No.
Converting pin point to Shackle point including dismantling &
117 9924000040 location
restringing etc.
replacement of 11KV Pin insulator with providing new double pin
replacement of 22KV Pin insulator by new 11kv pin insulator with
spares & providing new double pin binding
120 9924000043 Providing 11kv double disc insulators with binding & restringing No.
Replacement of existing 11kv conductor (all size) with new double Cond/K
122 9924000046 Plumbing of PSC Pole with straightening at pin point No.
123 9924000047 Plumbing of PSC Pole with straightening at tension point No.
Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling of stone
Providing new 11kv AB /GO switch with fabrication and insulated
colour code jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with providing new
insulated jumper, binding, lugs etc
Providing cage type loop guard in vertical LT line with using PVC
127 9924000052 per pole
reel insulators etc
Labour charges for replacement /providing of MMB & service with
all accessories for three phase connection
Labour charges for replacement /providing of MMB & service with
all accessories for single phase connection
Dismantling of existing Dist. X'mer centre(RSJ /STP POLE)
130 9924000055 25/63/100/200 KVA with all fabrication & crediting the old No.
material to store
131 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase ( payment after receipt of R/C
133 9924000058 Disconnection from LT pole 3 phase No.
134 9924000059 Reconnection from LT pole 3 phase ( payment after receipt of R/C No.
Dismantling & removing of service line from pole & crediting to S/dn
Dismantling & removing of service line from pole & crediting to S/dn
137 9924000062 Reconnection of service line complete with PVC cable (1 Ph) No.
138 9924000063 Reconnection of service line complete with PVC cable (3 Ph) No.
Providing spiral type earthing by G.I. NO 8(weight 2kg -5mtr in
length) with salt and coal 10kg each, including pvc rigid pipe 20mm
dia. ( 1.5mtr length) to pass exposed part of G.I. wire at consumer
end with all materials, earth resistance should be less than 2 ohms
Providing and fixing of single core 1.5 sq mm single strand copper
insulated cable with cable nail clip for spiral type earthing at
consumer end. The end of G.I. no 8 is to be connected by connector
140 9924000070 with copper cable of which other end shall be connected to the earth per meter
terminal of meter box. This item shall be used in location where
there is more distance between earth terminal and earthing terminal
of meter. (All materials supplied by contractor)
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM including fitting of
all accessories i.e. special design suspension / tension clamp, fixing
of cross arm, LT shackle insulator etc. for fixing of messenger wire
and inclusive of dismantling charge of existing bare conductor and
crediting in to store & dismantling of service line from LT bare
conductor and to provide service connection on Aerial Bunch Cable
by insulated piercing connectors through service connection box
complete as required & directed by Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM
including fitting of all accessories i.e. special design suspension /
tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing
of messenger wire and inclusive of dismantling charge of existing
142 9924000066 bare conductor and crediting in to store & dismantling of service line KM
from LT bare conductor and to provide service connection on Aerial
Bunch Cable by insulated piercing connectors through service
connection box complete as required & directed by Engineer in
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM including fitting
of all accessories i.e. special design suspension / tension clamp,
fixing of cross arm, binding to pin insulator, preparing shackle point,
jumpers etc. and inclusive of dismantling charge of existing bare
conductor and crediting in to store complete as required & directed
by Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM including
fitting of all accessories i.e. special design suspension / tension
clamp, fixing of cross arm, binding to pin insulator, preparing
shackle point, jumpers etc. and inclusive of dismantling charge of
existing bare conductor and crediting in to store complete as
required & directed by Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM
including fitting of all accessories i.e. special design suspension /
tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing
of messenger wire and inclusive of dismantling charge of existing
145 9924000069 bare conductor and crediting in to store & dismantling of service line KM
from LT bare conductor and to provide service connection on Aerial
Bunch Cable by insulated piercing connectors through service
connection box complete as required & directed by Engineer in
(C) UG CABLE RATES
146 9925000001 Labour charge for excavation of cable trench of 400mm width x Meter
1200mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 600mm width x
1200mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 400mm width x
1500mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to
240 mm2 & preparation of sand layer 100mm thick, in the cable
trench & covering the cable with 150 mm dia (Inner), thickness
mm, 1.0 meter long RCC half round muffs and providing and fixing
of 4inch width yellow colour polyethylene tape with printing
"CAUTION ELECTRIC CABLE BELOW" at 0.75 m depth from ground
surface after laying cable in trench. This will provide indication that
electric cable is passing underground so as to protect cable from
mechanical injuries, refilling the same, as per Instruction of Engineer
in Charge (EIC).
Labour charge for horizontal drilling using Auger machine
without damage to surface road at max 2.0 mtrs depth & putting of
6.11 kg/cm2 , class-4,Green colour, 110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984- 1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of size up to
mm2 in HDPE pipe, as per Site Condition (excluding cost of pipe).
The detail map obtained from HDD machine and excel sheet (hard
and soft copy) indicating the respective depth and distance from
adjacent landmark for each segment for HDD is must require to be
submitted. HDD to be carried out at
depth 1.5 mtrs to 2.0 mtrs as per site conditions and as per
instruction of EIC.
Labour charge for horizontal drilling manually without damage to
surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2, class-
4, Green colour, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision) and BIS certification and
laying of 11KV/22KV XLPE cable of size up to 240 mm2 size, as per
Site Condition (excluding cost of pipe). The detail map and excel
sheet (hard and soft copy) indicating the respective depth and
distance from adjacent landmark for each segment of cable to be
submitted. Drilling to be carried out at depth Minimum 1.2 mtrs to
2.0 mtrs as per site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green colour, 110mm O.D. , 8.5 mm
thickness H.D.P.E. pipe confirms to IS 4984 and BIS certification for
laying of underground 11KV / 22KV XLPE cable up to 240 mm2
Labour work for RCC concreting on disputed location and repairing
of damage portion of road crossing for the work carried out for
roads crossing as well as concreting & muffing of poles including
all materials (1:2:4)
Providing & fixing concrete stone route marker of 300 mm width x
150 mm thick x 650 mm height embedded in earth at least
mm below & 350 mm above ground level respectively at distance
approx. 50 meters along the length of cable. The RCC concreting
(1:2:4)(all necessary materials will be in bidder's scope) of route
marker is to be carried out 300 mm width x 150 mm thick x 300 mm
below ground level as per instruction of EIC. The route marker
should be with name of company with approved yellow colour-
DGVCL. The distance from marker to cable and cable depth with
feeder name etc., marked with arrow sign is to be painted on it. The
route marker is to be fixed at location near to any fixed permanent
location (not necessary to fix exact on top of cable) as per
instruction of EIC.
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole
with cable connection arrangement along with fitting of necessary
155 9925000010 fabrication for 11KV cable including excavation of pit & refilling of No.
earth as per instruction of EIC. (Exclusive of concreting & muffing of
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with
cable connection arrangement along with fitting of necessary
156 9925000011 fabrication for 11KV/22 KV cable including excavation of pit & No.
refilling of earth as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole
with cable connection arrangement along with fitting of necessary
157 9925000012 fabrication for 11KV cable including excavation of pit & refilling of No.
earth as per instruction of EIC. (Exclusive of concreting & muffing of
Erection of Single pole structure using 8.0 Mtr PSC pole with
cable connection arrangement along with fitting of necessary
158 9925000013 fabrication for 11KV/22 KV cable including excavation of pit & No.
refilling of earth as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to
240 mm2 on DP Structure with fixing of 02 Nos polymer cleats
on top and middle part. Polymer cleats, nut bolts etc. fixing
material to be provided by contractor.
Providing & fixing of 6.11kg/cm2, class-4, Green colour, 110mm
O.D., 8.5mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS
certification on the erected DP structure for the mechanical
protection of cable by inserting the cable inside HDPE pipe. The
HDPE pipe shall be erected in such a way that 300mm shall be below
the ground level and the rest 2700mm shall be supported on the DP
Structure with 01 No Polymer cleat. All materials including polymer
cleat and Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B
GI pipe with pit to be filled with salt & coke and construction of
chamber as per DGVCL Drg. No. dg /100 for DP and cable. The
earthing pit should be joined with cable by G.I. strip of size 1” width
& 2 mm thick. All material GI pipe, Coke, Salt etc will be supplied by
Supply & fixing of heat shrink type end terminations (outdoor)
162 9925000017 for up to 11kV 3C x 185 mm2 size XLPE cable as per DGVCL No.
technical specification. (Make 3M or Raychem Only)
Supply & fixing of heat & shrinkable end terminations (outdoor)
163 9925000018 for up to 22 Kv 3C x 185 mm2 size XLPE cable as per DGVCL No.
technical specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrink type end terminations (indoor) for
164 9925000019 up to 11kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat & shrinkable end terminations (indoor) for
165 9925000020 up to 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrinkable straight through joint for up to
166 9925000021 11kV 3C x 185 mm2 size XLPE cables per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrinkable straight through joint type for
167 9925000022 up to 22kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Labour charge for excavation of 2100mm long x 1200mm wide x
1200 mm deep joint pits for installation of 11kV / 22kV Straight
through joints as per instruction of engineer-in-charge & covering
the cable with 150 mm dia (Outer), thickness 25 mm, 1.0 meter
long RCC half round muffs & refilling same as per instruction of
Providing and fixing of insulating bus bar, made from 11KV/22KV
XLPE cable after removal of semi conducting layer and applying of
PVC heat shrinkable anti- tracking core insulating tubing (1.1KV), on
both end terminal using Aluminium long barrel heavy duty up to
169 9925000024 240 sq mm lugs, Aluminium bus connector. Taping with PG- clamp No.
for bus conductor as per drawing and as per instruction of EIC. The
Aluminium lugs and PG clamp shall be covered with 11KV/22KV HT
insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope)
Testing of cable at various points and commissioning the feeder as
170 9925000025 per instruction of engineer-in-charge. Test result shall be submitted No.
by contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout
171 9925000026 drawings with GIS mapping as per actual cable routing showing Set
road crossing, HDPE pipe sleeving, jointing locations, markers etc.
Providing and fixing of Sign Board at junction point Made out of
mm aluminium sheet size 750x300 mm (2.5 x 1ft) rectangle, as per
design, pre-treated with phosphate process and acid etching coated
with one coat of epoxy primer and two coats of best quality paints,
reflectorized with Hi-Intensity retro – reflective sheeting as per the
latest and frame fabricated from suitable size iron angle. The Sign
Board is to be fixed on the base prepared from channel and bracing
angles which is grouted by means of cement concreting of 1:2:4 for
size of 300 mm dia x 800 mm height (500 mm to be grouted in
ground). The details to be displayed on sign board will be given by
In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger Board) on Distribution
Transformer Centres Made out of 2mm aluminium sheet size
300x300mm (1x1ft) as per design, pre-treated with phosphate
process and acid etching coated with one coat of epoxy primer and
173 9925000028 two coats of best quality paints, reflectorized with Hi-Intensity No.
retro- reflective sheeting as per the latest and frame fabricated from
suitable size iron angle. The Sign Board (Danger Board is to be fixed
at the location as per instruction of In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W)
from 3 mm aluminium sheet along with 1.0 mm dia aluminium
binding wire for fixing of aluminium tag near end termination joint
174 9925000029 at DP structure for identifying the cable. The details of feeder i.e. 11 No.
/ 22 KV with feeder name should be punched on the tag by letter
punch of size 16 mm as per instruction of In-charge Engineer.
Supply & fixing of heat shrink type end terminations (outdoor) for
175 9925000030 11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat & shrinkable end terminations (outdoor)
176 9925000031 for 22 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrink type end terminations (indoor) for
177 9925000032 11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat & shrinkable end terminations (indoor) for
178 9925000033 22 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrinkable straight through joint for 11kV
179 9925000034 3C x 240 mm2 size XLPE cable as per DGVCL technical specification. No.
(Make 3M or Raychem Only)
Supply & fixing of heat shrinkable straight through joint type for
180 9925000035 22kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Installation, Testing and commissioning of 11 KV,630 A SCADA
Compatible, RRL type- 3 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 11 KV,630 A SCADA
Compatible, RRLL type- 4 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA
Compatible, RRL type-3 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA
Compatible, RRLL type-4 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Construction of plinth for 11KV, RRL type- 3 Way (i.e. Two
numbers of Isolator & One number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no: Drg.
11kv-01. All required material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type- 4 Way (i.e Two
numbers of Isolator & Two number of Breaker)Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:Drg.
11kv-02.All required material will be supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e Two
numbers of Isolator & One number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no: Drg.
22kv-01. All required material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type- 4 Way (i.e. Two
numbers of Isolator & Two number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:Drg.
22kv-02.All required material will be supplied by contractor.
Modifications e.g. Providing and fixing of Terminal protectors i.e. Re-
use able boot (HT Side 11/22KV, LT Side 1.1KV) including 11/22 KV
insulating taps and L.T.(1.1 KV) insulating taps ,Busbar, Tapping
from Bus Bar (11/22 KV XLPE cable) through P.G. Clamp for H.T.
Jumper to D.O. Fuse to bushings of Transformer Centre, providing &
Fixing of jumper and providing & fixing of Heat Shrinkable Anti
Tracking Core Insulating Tubing (Insulation Level 11/22 KV) in H.T.
jumper , Clamping arrangement of cable support frame on both side
of existing Over Head type Distribution Transformer to utilize in
Under Ground cable network as per drawing & as per instruction of
Engineer in charge. All live parts i.e. PG-Clamp, connections of D.O.
fuses, HT bushings etc. shall be covered with fixing of 11/22 KV HT
insulating tapes. (11/22 KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope).
Laying of any size of 11/ 22 KV XLPE /PILC Cable in readymade Per Cable
trench or in open space Per Mtr
191 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC
half round pipe
Laying, Testing & commissioning of Specially designed 11 KV
193 9601000866 55mm2 AAAC Medium Voltage Covered conductor as per the CKM
technical specifications (with accessories)
ESTIMATE COST Thirty Lakh Rupees Only. Rs. 30,00,000/-
1. DGVCL will provide key material like M.S. materials, ABC/Bare conductors, PSC/RSJ Poles, Insulators,
Fabricated materials etc. to the contractor.
2. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding rods confirming to the
relevant ISI specification and as directed by Engineer in charge.
3. Necessary electricity connection for fabrication items shall be provided by DGVCL on payment of required
charge for connection & electricity bill of the same shall be paid by the agency.
4. All the rates are inclusive of PF & Exclusive of GST applicable time to time.
5. All steel material are to be painted as below:
a. Scrubbing of rusted surface properly before applying the paints on to the RSJ poles & steel fabricated
materials of RSJ/PSC poles is must require.
b. Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ poles & steel
fabricated materials of RSJ/PSC poles.
c. Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint) is to
be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
6. Cable End Termination and Straight Joint should be of Make 3M or Raychem Only.
Deputy Engineer (O&M),
Jambusar T sub Division,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ARC SCHEDULE-B.pdf
TENDER CONDITION JAMB T 102.pdf
Tender Notice Jamb T 102.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .