Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC NEAR KONAM GUEST HOUSE CO OPERATIVE COLONY CHODAVARAM VISAKHAPATNAM 531036 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 531036 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.0 L+₹7.5 L (23.8%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹39.3 L+₹7.8 L (24.7%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹41.0 L+₹9.5 L (30.0%)Rejected-Finance | L4 | Rejected-Finance Being Not L1 |
Tender Value
₹38.3 L
EMD Value
₹76,500
Closing Date
18 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
AS AND AS TO HULL REPAIR DEPT IN BLDG NO. 17A, 18, 18/1, 19 AND X3 COMPLEX AT NAVAL DOCKYARD VISAKHAPATNAM UDER GE(I) DM VISAKHAPATNAM
2023_MES_597440_1
8860/E8
Open Tender
Civil Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) DM Visakhapatnam
₹76,500
Yes
4 Aug 2023
22 May 2023
25 Jul 2023
22 May 2023
18 Jul 2023
6 Jul 2023
Amount
[SCHEDULE 'A' PART-I [B/R WORKS]
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish outside ND(V) premises complete all as specified and as directed.
M&L Non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed or bedding layer for laying tiles in CM 1:6 all as specified and directed.
Material & Labour for Non skid ceramic tiles 7 to 8mm thick (square/rectangular) in dado set and jointed in neat cement slurry and pointed in coloured cement to match fixed over incl rendering in CM 1:4, 10 mm thick complete all as specified and as directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqmn.but nexc 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n.exc 1.50 Sqm each complete all as specified and directed.
S&F anodised aluminium grill, having mess size 100mmx100mm made out 6mm wide & 3mm thick aluminium section complete all as specified and directed.
S&F Anodised Aluminium Frame Work (snap grid) for false ceiling Work made from Anodised Aluminium main /cross tee of size not less than 38 mm x 24 mm x 1.5 mm thick and 28 mm x 24 mm x 1.5 mm thick respectively for false ceiling of grid size 600 mm x 600 mm with & incliding providing pre painted fiber cement board 6 mm thick including necessary hanging arrangement comprising of 6 mm dia MS rod, 'J' bolts with necessary bolts, nuts and washer all as per manufacturer's instruction. The snap grid (main & cross section) shall be supported at ends all along the wall with Anodised Aluminium angle of size 40mmx25mmx2mm, weighing 0.36 Kg / RM. The main and cross tees shall be jointed at junction / crossings with anodized aluminium angle bracket of size 15mmxl5mmx1.5mm, weighing 0.12 Kg per running metre, fixed with suitable size mild steel, bolts nuts and washers complete as per manufacturer's instruction and as specified and directed including taking out old one..
M&L cutting holes in brick walls built in cement mortar for inserting holdfast / pipe etc and making good the dismantled portion in cement 1:3 or cement concrete 1:2:4 type B-1 all as specified and as directed depth of embeded portion of holdfasts / pipe or lugs measured from the face of the Jamb / wall face into wall exc. half brick but not exc. one brick.
S&F steel work in tubular pole including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 all as specified and directed.
&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
[SCHEDULE 'A' PART-II [E/M WORKS]
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, with fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials from the site and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed.
Taking down old UNSV DBs and main switches along with MCBs and MCCBs complete all as specified and directed.
M&L surface /concealed ( as ordered at site) point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including PVC rigid conduit medium grade with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point including supply & fixing of galvanised pressed mild steel Modular Terminal Boxes of suitable size as requires for fixing modular switch / sockets/ regulator etc. complete for one light / Fan / bazzer point controlled by one one way switches complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed.. (Note: if concealed type wiring is ordered at site, cutting chases shall be measured and paid seperately under respective items in this Schedule)
M&L surface /concealed type (as ordered at site) point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including PVC rigid conduit medium grade with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point including supply & fixing of galvanised pressed mild steel Modular Terminal Boxes of suitable size as requires for fixing modular switch / sockets complete for one 3/5 pin 5/6 Amp socket outlet on independent board complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed..(Note: if concealed type wiring is ordered at site, cutting chases shall be measured and paid seperately under respective items in this Schedule)
M&L surface /concealed type (as ordered at site) point wiring with 2.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with and including PVC rigid conduit medium grade with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls etc. with and including 2.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core copper cable as earth continuity wire connecting to common earth point including supply & fixing of galvanised pressed mild steel Modular Terminal Boxes of suitable size as requires for fixing modular switch / sockets complete for one 5/6 pin 15/16 Amp socket outlet on independent board complete all as specified and directed including necessary chase cutting for conduits and sinking boxes and making good to walls, floors etc.complete all as specified and directed..(Note: if concealed type wiring is ordered at site, cutting chases shall be measured and paid seperately under respective items in this Schedule)
M&L cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps cills, sunshades, shelves, lintels etc. in brick walls and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc. 10 cm girth complete all as specified & directed.
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed.
S & F Switch socket combination 5 Pin, 6 Amps, 240 Volts, flush type multi-purpose, conforming to IS complete all as specified and as directed.
S & F Switch socket combination 6 Pin, 16/6 Amps, flush type, multipurpose, conforming to IS complete all as specified and as directed.
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type 120 W complete all as specified and directed.
Taking down sub main wiring with aluminium / copper conductor cable of any size drawn through rigid conduit / casing capping etc. (surface/concealed) including accessories etc. complete all as specified & directed
M&L Sub main wiring with two runs of 6.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit / PVC casing caping complete fixed to wall / ceiling etc incl one run of 6.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. (Note :-(i) PVC rigid conduit / PVC casing caping with all fittings/accessories shall be measured and paid separately. (ii) Two runs of 6.0 sqmm single core cable, one run of 6.0 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured and paid separately under relevant items in this schedule.).
M&L Sub main wiring with four runs of 10.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit / PVC casing caping complete fixed to wall / ceiling etc incl two run of 10.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. (Note :-(i) PVC rigid conduit / PVC casing caping with all fittings/accessories shall be measured and paid separately. (ii) Four runs of 10.0 sqmm single core cable, two run of 10.0 sqmm earth continuity wire to be measured as one length (iii) chase cutting if required shall be measured and paid separately under relevant items in this schedule.).
Supply only 20 mm x 12 mm medium grade PVC casing and caping with all fittings and accessories of PVC casing and caping (like Tee, bend etc.) including taking down old one complete all as specified and directed.
Supply only 25 mm dia medium grade PVC rigid conduit with all fittings and accessories of PVC RIGID CONDUIT (like Tee, bend etc.) complete all as specified and directed.
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve including taking down unserviceable one complete all as specified and as directed.
S&F MCB, three Pole, 40 to 63 amps, 415 Volts including taking down unserviceable one complete all as specified and as directed.
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way complete all as specified and as directed.
S&F Metal plug and socket board with MCB SP 20 amp, 16 KA including taking down unserviceable one complete all as specified and as directed.
S&F ceiling fan of sweep 1400 mm,5 star rated BLDE including all accessories, clamps wire etc. to hang the fan in position including provision of cable from ceiling rose to fan complete all as directed
S&F white blanking plate one module complete all as specified and directed.
Supply and fix square shaped recess mounted LED slim panel down lighter, 36 watt (2`x2`), to POP/grid celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable complete all as specified and as directed including taking down unserviceable one
SATYAMEGHA ENGINEERS
prasad constructions
CIVILEC ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .