Loading…
Loading…
Tender Value
₹17.9 L
EMD Value
₹35,900
Closing Date
10 Jul 2025, 3:00 pmClosed
Vadodara Division :- Telecom work in connection with the work "Improvement of Service Buildings with various activity like Leakage proofing, flooring, watering and drainage line improvement, etc. at Godhra Station".
SandT_BRC_25-26_08_TEL
SandT_BRC_25-26_08_TEL
Open
Works - General
4 Months
Vadodara, Gujarat
₹0
₹35,900
18 Jun 2025
18 Jun 2025
Supply of STP (Shielded Twisted Pair) CAT-6 cable compliant with latest EIA/TIA-568-B. 2-1 standard of make D-Link/ DAX/ Lucent/ Crone/Amp.
Supply of Shielded RJ-45 CAT6 / CAT 6A RJ-45 Connectors (10 pcs per pack) - Pass 2 Through Connector Gold Plated 3 Prong 8P8C Modular Plugs for FTP/STP Stranded Ethernet Cables and Solid Wire 23AWG. Make: D-Link/Digisole/Spectra/DAX/Megbyte. NOTE: THE UNIT MAY BE READ AS 'PACK'.
Supply of Manageable layer-2 switch (POE) 24 ports with 4 SFP ports; populated with 1Gbps SFP Modules as per RDSO/SPN/TC/83/2014, Rev.1.0, Amd. 1.0 or latest of make Cisco, D Link or Juniper.
Supply of Single Fiber SFP module 1Gbps up to 20 Km. distance.
Supply of 06 Core Optical Fiber Cable Armoured Single Mode.Make : D-Link or similar of reputed make.
Supply of 2x24 fiber optic fiber splice straight joint enclosure (SJC) complete with all accessories as per RDSO/SPN/TC/68/2014, Rev.3 or latest specs for 24 fiber OFC cable with latest amendment.
Supply of power cable 3 core, 2.5 sq mm, multi-strand [36/0.3mm dia.] cable as per IS 694:1990 reaffirmed 1995 or latest suitable for Railway electrification area, shall be of reputed make LIKE Vedanta, Havells, Delton, LAPP, Finolex, or superior.
Supply of Rigid uPVC conduit of having outer dia. 25mm and inner dia.21.4 mm with ISI mark (IS:9537 Part-3).
Supply of 25mm inner dia PVC Networking Flexible Pipe of reputed make. Pipe Colour - as per site requirements.
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc.
Supply of Remote Craft Terminal as per specification.
Supply of 12 ft Aluminium folding ladder self supported, light in weight , fire proof, 12 ft in height having non slip flat steps with Aluminium frame rigid and platform on top enabling one person to handle. The separator between two legs of ladder should be of metal.
Supply of 20 pair 0.5mm annealed copper conductor PVC insulated switch board Telephone indoor cable as per specification.
Supply of 10 pair twisted conductor PVC indoor cable (0.5mm) dia annealed copper conforming to as per TEC spec No GR-WIR -06/03 March 02 or latest.
Supply of 5 pair twisted conductor PVC Indoor cable (0.5 mm dia) annealed copper confirming to as per TEC spec no GR WIR 06/03 March 02 or latest.
Supply of 10/12 pair CT box for termination cables as per the details approved by the engineer.
Supply of Optical Fiber Cable Termination Box for 6 fibers as per specification and splicing of fiber with low loss of pigtail cables. Splice losses in no case should be more than 0.1dB. Necessary 0dB connectors should be provided in OFC Termination Boxes.
Supply of OFC patch chord with SC connector at one end LC/SC connector at another 18 end as per site requirement (suitable for media convertor/ SFP supplied) & length of patch cords may be varying from1.5 to 10 Mtrs in length or as per site requirement as per RDSO/SPN/TC/69/2007 Rev.1.0 or latest.
Supply of Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008.
Supply of 35 Sq.MM multi-strand Single Core Copper Wire as per specification. Wire Colour - As per Site Requirements.
Supply of 16 Sq.MM multi-strand Single Core Copper Wire as per specification. Wire Colour - As per Site Requirements.
Supply of 10 Sq.MM multi-strand Single Core Copper Wire as per specification. Wire Colour - As per Site Requirements.
Supply of 802.11AC WAVE 2 DUAL RADIO CEILING MOUNT POE ACCESS POINT WITH 23 2X2 MIMO EMBEDDED ANTENNA, 866 MBPS WIRELESS SPEED ON 5 GHz FREQUENCY BAND AND CLOUD MANAGEMENT FACILITY. MAKE :ZYXEL / NETGEAR /CISCO (Warranty Period: Upto 30 months fromthe date of supply)
Supply of Exothermic Welding Kit for earthing as per specification.
Supply of 10 port Manageable switch including 2 SFP ports; populated with 1Gbps SFP modules and its standard installation as per specification. Make: Juniper or CISCO or Extreme.
Laying of OFC/Power cable/CAT-6 cable/PA Cable/Data cable and all the other types of telecom cable through HDPE pipe/casing capping/fall ceiling with laying/fixing of HDPE pipe/casing 2 capping/PVC pipe for connecting/ interfacing various components and system integration. All materials for jointing and termination of power cable/CAT-6cable as per site requirement areto be supplied by contractor. This item also includes supply of RJ-45 connector with cap for terminating CAT-6 cable and supply and installation of power board with 4 points (3 nos. 5Amp sockets and 1 no. 15Amps socket) as per site requirement.
Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge along side the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route 3 from bushes etc, covering of cable laid in trench by loose soil. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1mis not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
Horizontal direction drilling [HDD]/Trenchless digging/machine drilling without damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank 4 height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor has to provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe islaid in the bore.
Transportation and Laying of HDPE duct as per the approved cable route plan in the excavated trenches/other protected works/RCC channel etc. including all accessories like end caps, 5 collars, bends, couplers etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively ,issued vide Chapter-XIII of the Telecomm Manual.
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/Trunking. This also includes laying of cables in track crossings & road crossings. Item 6 includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P. (Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
Fixing of all types of Cable Termination box and termination of cable. This include armour earthing also.
Splicing of fibers OFC Cable and making Splice joint with contractor's own splicing machine and tools and consumables.
Blowing of OFC through HDPE duct & protective work already provided. Where it is not 9 feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason , OFC shall be drawn / laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. NOTE: The unit may be read as "RM'.
Placing of DWC/RCC/GI pipes along with collars in trenches at places of track and road crossings, platform cuttings etc.
Supply and Fixing on wall with the help of farse nut of 12U Networking Rack 19 inch with Front Glass Door, 06 Socket Power DB, 02 Fan-Fan Tray, Cable Manager, Hardware Packet, Earthing etc. Make: APW-President or similar of reputed make.
Installation, testing & commissioning of Maintenance Free earth electrode as per RDSO Specification No. RDSO/SPN/197 Ver.1or latest so that the earth reading should not be more than 1 Ohm. Construction of earth pit should be as per Drawing No. DSO/RDSO/E&B/001. Earth enhance material shall be carbon based with min 95% of fixed carbon content premixed with corrosion resistant cement to have set properties. Cement shall not mix separately & shall not have Bentonite. shall have high conductivity, improves earth's absorbing power and humidity retention capability. shall be non-corrosive in nature having low water solubility but highly hygroscopic, shall have resistivity of less than 0.2 ohms -meter. shall not depend on the continuous presence of water to maintain its conductivity shall be permanent.
Concealed wiring of Telecom cable in PVC conduit - The price shall cover for concealed wiring of Telecom cable 5 Pair, 10 Pair, 20 Pair, PA Cable/Data Cable PVC insulated, unsheathed, PIJF 13 Cable in concealed manner as per site requirement in PVC conduit (All jointing accessories like junction boxes, 25mm PVC L-bend, T-bend, etc. are to be provide by the contractor). Concrete/Platform surface and its refilling/plastering to its original position after laying of Telecom Cable.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .