Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.9 L
EMD Value
₹21,780
Closing Date
31 Jul 2025, 11:00 amClosed
EXECUTIVE ENGINEER STD Sopore
AMARGARH STD Sopore
Supply,Installation,Testing and Commissioning of 11 KV Indoor Switchgear to be installed at Receiving Station Tikker For Construction Of Dedicated 11 KV Feeder For District Jail Kupwara
2025_PDD_280216_1
STDS/05 of 2025-26
Open Tender
Electrical Works
Turn-key
45 days
STD Sopore
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,004
Yes
Executive Engineer STD Sopore
₹21,780
Yes
1 Aug 2025
1 Jul 2025
31 Jul 2025
1 Jul 2025
31 Jul 2025
3 Jul 2025
1 Jul 2025 - 3 Jul 2025
Amount
Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 KV Outgoing SCADA Compatible VCB Panel Board (12 kV, 1250A, 25 kA-3 Sec, Indoor) with Numerical O/C, E/F relays confirming to IEC61850, Master Trip Relay, Mimic Diagram, Digital Voltmeter with VSS, Digital Ammeter with ASS, PF Meter, Frequency Meter, Annunciation Windows with annunciation relays(6-Windows), 3-phase Tri-vector meter -5 Amps DLMS Compliant with RS-485 port ,Double Ratio; Three Core(0.5,5P10,PS) Epoxy Casted CT with CTR :100-50/5-5A,TNC Switch, LR switch, Indication Lamps & other equipments as per approved Technical Specifications, of reputed make including Fixing of Earthing & Feeder Name Plate with Name of feeder written on it by using high intensity reflective Tape. (Reputed Make)
Supply, Carriage upto site (including Loading/Unloading), Testing and Erection of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long ) as per approved drawings/standards
Carriage upto site (including Loading/Unloading), Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (100mm2 ACSR Conductor) (Conductor to be provided by the department) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing,Fabrication & Fixing of GI Channel/Angle/Flat of sizes including clamps as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, Horizontal mounting Type, with Earth Switch (Reputed Make, Sample to be approved before installation) as per approved drawings/standards (1 Set- 3 Pieces)
Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type (Reputed Make) as per approved drawings/standards (1 Set-03 No.)
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mms as per approved drawings/standards
Supply,Testing,Loading,Carriage,Unloading and fixing of Galvanised Nuts & Bolts of sizes
Supply,Testing,Loading,Carriage,Unloading and fixing of Danger Plates with Clamps as per approved drawings/standards
Supply,Testing,Loading,Carriage,Unloading and fixing of Anti-Climbing Device with Clamps as per approved drawings/standards
Providing & Painting of Poles with one coat of Red Oxide and two coats of aluminium paint and as per approved drawings/standards
Supply,Carriage upto site (including Loading/Unloading), Laying & Testing of Cement bottoming for ST Poles 9 Mtr in the mixture of 1:2:4 0.48 cum/pole as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS( Polycab, Havells, KIE, Anchor or any other reputed make) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 36 V,200 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply of reputed make) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of Battery Bank 36 V,200 AH , of 18 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant of reputed make) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 11kV Three core 185 mm2 Aluminium wound wire Armoured XLPE FRLS Cable (KIE/Havells/Polycab make)as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing,Fabrication & Fixing of Mild Steel Chequered Plates, Material Grade: Is 3502, 8 mm as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading) & Fixing of Rubber Mat 1mx2m 19mm thickness as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11 kV Heat Shrinkable Outdoor Cable Termination Kit suitable for 185 mm² ( 3 Core) cable (3M/VIKCHEM/Denson make) as per standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11 kV Heat Shrinkable Indoor Cable Termination Kit suitable for 185 mm² ( 3 Core) cable (3M/VIKCHEM/Denson make) as per standards
CONTENGENCIES /T&P/Spares
Supply, Carriage upto site (including Loading/Unloading),Testing of 12 KV Double Ratio; Three Core(0.5,5P10,PS) Epoxy Casted CT with CTR :400-200/5-5A as per standards
Supply, Carriage upto site (including Loading/Unloading),Installation, Testing of Complete Charging/ Gear Mechanism suitable for 11KV VCB
Supply of A4 Papers 75 GSM of standard Quality
Supply of Printer Cartridge suitable for HP laser Printer (110 A)( HP OEM Make)
Supply, Carriage upto site (including Loading/Unloading),Testing of 30-36 VDC Tripping coils suitable for 11KV VCB
Supply, Carriage upto site (including Loading/Unloading),Testing of Telescopic Aluminium Ladder 18 ' long
UMAR ELECTRICALS (BID ID -2413804)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .