Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.8 LAccepted-AOC | L-1 | Accepted-AOC awarded to lowest | |
| 2 | L-2₹7.2 L+₹37,915.57 (5.58%)Rejected-Finance | L-2 | Rejected-Finance Highest bidder | |
| 3 | Rejected-Technical E 172 CHAURA MAIDAN 103 TUNNEL SHIMLA HIMACHAL PRADESH 171001 | SHIMLA | HIMACHAL PRADESH | 171001 | - | Rejected-Technical Not Qualified | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Qualified |
Tender Value
₹6.9 L
EMD Value
₹13,800
Closing Date
24 Jan 2026, 11:00 amClosed
EXECUTIVE ENGINEER
Electrical Division HPPWD Palampur
Construction of community health center building at Garli, Tehsil Pragpur, District Kangra (HP) (SH Retrofitting work in unit 2 and unit 3) (SH Providing rewiring therein)
2026_PWD_126028_1
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Percentage
Pragpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹350
₹13,800
25 Sept 2026
17 Jan 2026
24 Jan 2026
17 Jan 2026
24 Jan 2026
17 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit having wall thickness minimum 2 mm, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group C. Makes: Legrand(Myrius),Schiender(Livia),Anchor Roma(Plus),L&T(Entice).
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C. Makes: Legrand(Myrius),Schiender(Livia),Anchor Roma(Plus),L&T(Entice).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required
2X1.5Sq.mm+1X1.5Sq.mm Earth wire
2X2.5Sq.mm+1X2.5Sq.mm Earth wire
2X4Sq.mm+1X4Sq.mm Earth wire
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Makes: Plaza/Finolex/Anchor.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Makes: Plaza/Finolex/Anchor.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3X1.5 Sq.mm
3X2.5Sq.mm
3X4Sq.mm
Makes: Plaza/Finolex/Anchor.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Makes: Legrand(Myrius),Schiender(Livia),Anchor Roma(Plus),L&T(Entice).
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc as required.
Makes: Legrand(Myrius),Schiender(Livia),Anchor Roma(Plus),L&T(Entice).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3Nos 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.(For light plugs to be used in NR Buildings).
12 Module (200mmX150mm)
Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus),L&T(Entice).
Supplying and fixing extra down rod of 60cm length G.I. pipe 15mm dia heavy gauge including painting etc. as required.(Note:-More than 5cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored.) Makes:-Jindal Hissar.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular socket outlet and 25 amps modular SP MCB "C" curve including connection,painting etc. as required.
Makes:- Legrand(Myrius),Schiender(Livia),Anchor Roma(Plus),L&T(Entice).
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required.
Single pole. Cat-A.
Makes: L&T, Legrand,Anchor Uno.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps. Cat-A.
40 Amps. Cat-A.
Makes: L&T, Legrand,Anchor Uno.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps. Cat-A.
40 Amps. Cat-A.
Makes: L&T, Legrand,Anchor Uno.
Supplying and fixing Ding dong bell suitable for single phase, 230 volts, complete as required.
Makes: Anchor/Goldmedal.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.
Armoured cable 35 sq. mm (3.5 core)
Armoured cable 25 sq. mm (3.5 core)
Makes:-Polycab,Palza,Finolex,Havells
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Armoured cable 35 sq. mm (3.5 core)
Armoured cable 25 sq. mm (3.5 core)
Makes:-Polycab,Palza,Finolex,Havells
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required.(But without MCB/RCCB/Isolator).
Makes: Legrand,Schiender,L&T.
Double door-16 way
Providing and installation exhaust fan of following sizes in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: (With 5 Years Warranty).
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Makes:-Exhaust Fan, Light duty, (Domestic) 300 mm sweep (Make: Usha, Model: Aeroclean LD)/Bajaj/Anchor.
Supplying and fixing of LED Batton/LED Mirror Light 5 WAtts, 6500K ,(Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc as required of Approved Makes.(Including 5Years Warranty).
LED Mirror Light 5 Watts
Makes:Wipro,Bajaj,Panasonic,Philips.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required: of Approved Make
Ceiling Fan 1200 mm sweep BLDC, Category-A
Ceiling Fan 1400 mm sweep BLDC, Category-A
Make:- Usha,Bajaj,Crompton.
Providing and Fixing of IP20 LED Surface mounted CRCA Powder Coated Box Type Channel with Pro LED Lamp Suitable for mounting 1 X 18 W LED Tube T8 type having minimum system efficacy of 100 lm/W, P.F.>0.95 with THD<10% ,CCT 6500 K,CRI 80,Surge Protection 2 Kv.The LED with Useful life of 50000 Hrs at L70 . The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.
LEDTube Light 18 Watts
Makes:Wipro,Bajaj,Panasonic,Philips.
Providing and fixing surface/Recess mounted Round/Square downlighter with die cast Al housing in white powder coated finish, anti glare diffuser and and energy efficient electronic driver ,suitable for surface application with the use of the latest technology 18watt (1800 Lumen) 6000K and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required. (With 5 Years Warranty).
Round/Square LED Surface/Recess Panel Light 18/20 Watts
Makes:-Wipro,Bajaj,Panasonic,Philips.
Providing and fixing of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of greater than 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 .The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K only with CRI of minimum 80.The Input voltage range shall be 140V to 280V, 50/60 HZ complete with all accessories, including connections, testing & commissioning etc.as required complete in all respects.
LED 10 Watt Bulk Head
Makes:Wipro,Bajaj,Panasonic,Philips.
Providing, Installation, testing and commissioning of wall fan of following size by means of suitable rag-bolt/ nuts, connections, testing and commissioning etc. as required complete in all respects to the best satisfaction of Engineer-in-charge .
Wall fan 400mm Sweep
Make:Usha, Bajaj & Cromptons.
Supplying and fixing of LED Street light Luminaire comprises of Al Die cast Housing with frame , High Purity PC lens Diffuser,cradle mounting, minimum system lumens of 5000. The luminaire shall have CCT of 5700K and CRI of minimum 80, PF>0.95 and THD>10%. The luminaire shall have IP66 and IK08 protection. The LED shall be compliant with Useful L70 life of 50000 Hrs. Driver efficiency should be 85% to operate in input voltage range of 100V to 270V (nominal rated voltage – 240V) with 4 KV internal surge protection and 10KV external surge protection. (With 5 Years Warranty). (With 5 Years Warranty).
LED Street Light Luminaire 36 Watts.
Makes- Wipro/Havells/Bajaj/Panasonic.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:-
25 Liter capacity water heater (Cat-A)
Makes:-Bajaj,Usha,Racold.
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14G/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 100A 4 Strip Copper Busbar ( Vertical/Horizontal) & Earth strip throughout the length of Panel (current density of Copper Busbar shall be 1mmx1mm=1.0 Amp.) Copper shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Approximate Size of Panel H- 700mmX W-500mmX D-200mm. The Assembly Charges of 100 Amps 4P Copper solid/ Copper flexible wire interconnection Busbar to MCCB & MCCB/MCB to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc and the panel should be approved/tested from the CPRI lab and should be Comfirm I.S.64139(EVAPower system & control ,DSPL,KSB Electric Company,Hark Power control.)
MATERIAL:
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc,
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14G/16G CRCA sheet, base frame40X40X5MM angle duly painted with Siemens Grey Powder Coated paint as per specification Approx size (H)600mm,(W)1050mmX(D)300mmX(L)150mm, Assembly Charges of 125A 4 Strip Copper Busbar ( Vertical/Horizontal) & Earth strip throughout the length of Panel (current density of Copper Busbar shall be 1mmx1mm=1.0 Amp.) Copper shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black, assembly Charges of Copper solid/ Copper flexible wire interconnection Busbar to MCCB & MCCB/MCB to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc and the panel should be approved/tested from the CPRI lab and should be Comfirm I.S.64139(EVAPower system & control ,DSPL,KSB Electric Company,Hark Power control.)
MATERIAL:
MAIN INCOMER: MCCB-125A 4P 25 kA TMR with O/L & S/C Protecrtion-1 No., Spreader Link 125 A 4P-1Nos., Phase indicating Lamp-3 Nos, Control SP MCB -3Nos.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Providing Installation,Testing and Commissioning of Triple Pole & Neutral 100 Amps as required complete in all respects.
Providing Installation,Testing and Commissioning of Copper Bus Bar 100 Amps with enclosure as required complete in all respects.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
pragpurr.pdf
Tender Documents • 3.69 MB
Declaration.pdf
Additional Documents • 0.01 MB
BOQ_185722.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .