Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | L1 | Accepted-AOC Lowest reasonable tenderer | |
| 2 | L2₹21.1 L+₹2.1 L (11.0%)Rejected-Finance | L2 | Rejected-Finance Not Lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
6 Jul 2021, 6:00 pmClosed
GE Ranikhet
GE Ranikhet
REPAIR/ REPLACEMENT OF STREET LIGHT FITTINGS MCCB LT PANELS AND LT OVER HEAD / UNDER GROUND LINE ETC AT HALDWANI INCLUDING KATHODAM RANIBAGH AND KAMOLA UNDER GE RANIKHET
2021_MES_449993_1
GE/RKT/ 09 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Haldwani under GE Ranikhet
Class E cat b ( i)
7 documents required · 7 mandatory
₹500
Yes
GE Ranikhet
₹40,000
Yes
16 Jul 2021
9 Jun 2021
8 Jul 2021
9 Jun 2021
6 Jul 2021
24 Jun 2021
Amount
BOQ ( Sch A ) Electric works Excavation in trenches not exceeding 1.50M wide and not exceeding 1.5M depth in hard/dense soil and getting out for laying pipes, cables etc and fitting including forming bottom surface to required level and slope complete all as specified and directed.
Returning, filling in, trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and directed..
Supply, laying, jointing , testing and commissioning under ground LT cable XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade cross sectional area 240sqmm 3½ core laid in trenches, floor through pipes,in duct, on pole and roads etc including making good as per existing complete all as specified and directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for the same. 2. Excavation, earth work, sand cushioning and cement protection cover will be measured and paid separately under respective items
All as per Srl item No 4 here-in-before but sectional area 150sqmm 3½ core
All as per Srl item No 4 here-in-before but sectional area 70 sqmm 3½ core
All as per Srl item No 4 here-in-before but sectional area 50 sqmm 3½ core
All as per Srl item No 4 here-in-before but sectional area 25 sqmm 3½ core
All as per Srl item No 4 here-in-before but sectional area 16 sqmm 2 core
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement)
Supplying and laying unreinforced precast concrete cabl;e cover , class LV, type 1, flat, size 250mmx150mmx40mm complete all as specified and directed.
Supply, fabricating and fixing cross arms (any type) supports, bracing, stiffener etc made out of MS channel, angle iron , flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint including dismantling of unserviceable cross arm complete all as directed by Engr-in-charge.
Material and labour for stringing, stretching and strengthening of overhead conductor (ACSR) on existing LT steel tubular pole, RS Joist , LT electric polr including binding and jointing the conductor with and including 14 SWG binding wire and following sizes ACSR conductors: - (a) 6/1 X 2.59 mm aluminium and 1 X 2.59 mm steel (Weasel) (b) 6/1 X 2.11 mm aluminium and 1 X 3.15 mm steel (Ferret) Note:-Any break or damage to insulator shall be changed by the contractor without any extra cost. Rate quoted by the contractor shall be deemed to be included this.
Supply and fixing in repair pin type, porelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 volts grade complete all as specified and directed.
Supply and fixing in repair shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75 mm height and 90 mm dia for working pressure of 1100 volts, LT complete with galvanised mild steel strap of size 31 X 3 mm / flat iron 50 X 6 mm ‘D’ clamp or ‘U’ clamp of suitable size and holding clamp, washers, insulator bolts of 12 mm dia, washers and nuts complete all as specified and directed.
Material and labour in repair loop type insulator small size, with overall dimensions 65x90mm, clearance of hole 16mm porcleain vitreous, white, brown or green complete all as specified and directed.
Material and labour for for MCCB 4 pole 415V adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed.
Material and labour for for MCCB 4 pole 415V adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed.
Material and labour for for MCCB 4 pole 415V adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and directed.
Material and labour for for MCCB 4 pole 415V adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed.
Material and labour for for MCCB 4 pole 415V adjustable type 630 Amps with breaking capacity 50KA complete all as specified and directed.
Supply and fixing / laying of galvanized iron pipe of 80 mm nominal bore light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc with clamps nuts, bolts and washers complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be included in the item rate.
Material and labour for supply, transporting, erecting truly in vertical position and fixing of steel tubular pole swaged, over all length 9 metres, type 410 – SP – 31 complete with mild steel base plate, pole cap, finial taper plug, MS bolts, nuts & washers, necessary excavation & earthwork in hard / dense soil, PCC sub base block as mass concrete of size 600 X 600 X 150 mm in cement concrete 1:4:8 Type D-2 in base of foundation, PCC foundation block of size 600 X 600 X 1500 mm in cement concrete 1:3:6 Type C-2, pole plinth of size 600 X 600 X 300 mm in cement concrete 1:2:4 Type B-1 including necessary form work as required at site and painting of pole with two coats of anti corrosive black bituminous paint through out internally and externally upto planting depth (embedded in concrete) and remaining portion of the pole painted two coats of aluminium paint over a coat of red oxide primer on complete exposed surface including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) including dismantling existing damaged steel pole/ struts etc complete all as specified and directed.
Supply and fixing stay assembly comprising of GI stay bow 14mm dia, 40cm long, galvanised stay rod 16mm dia, 180cm long with threaded ends, GI nuts, bolts, washers, GI stay plate 23x23cmx6mm thick, 02 Nos of thimbles, thimbles loop insulator size 90x140mm clearance hole 16mm MS clamps made out of 50x6mm flat iron, bolts, nuts, washers and stay wire 7/3.15 SWG, stay clamp, complete including necessary excavation, earth work in any type of soil, PCC 1:3:6 type C-2 in foundation all as shown in electrical plate No. 01 of SSR-2009 part1 , disposal of surplus soil to a distance of 50m including two coats of aluminium paint over a coat of red oxide primer on exposed mild steel work including dismantling existing stay assembly etc complete all as specified and directed.
Supply and fixing guard cradles, make to shape, hexagonal / rectangular or any other shape as required and directed, on LT electric lines fabricated out of 4 mm dia GI wire including 14 SWG binding wire complete all as specified and directed.
Material and labour in replacement of anti climbing device spikes type fabricated out of MS bar (round, square and flat) including nuts bolts, washers and welding in two halves made to shape to suit the cross section of the pole etc complete all as specified and directed.
Material and labour in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 20x15 cm size etc complete all as specified and directed.
Supply and fixing or passing through pipe, stranded conductor 6 Sqmm, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers no more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular etc all as specified and directed.
All as per Srl item No 28 here-in-before but size of conductor 10 sqmm
All as per Srl item No 28 here-in-before but size of conductor 16 sqmm
Material and labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 25 X 4 mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. Note: - On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Material and labour for cable jointing kit for 1100 V (Earthed) grade cable for straight through joint complete with jointing materials ( Epoxy bases) and acecessores suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 240 sqmm.
All as per Srl item No 32here-in-before but cable of size 120sqmm to 150 sqmm
All as per Srl item No 32 here-in-before but cable of size 70sqmm to 90 sqmm
All as per Srl item No 32 here-in-before but cable of size 25sqmm to 50 sqmm
Supplying, commissioning & testing of Time light distribution board/street light timer switch with anolog time switch with battery backup, 3P module, 24 hours program, programmabel 15 min, backup of 100 hrs, current capacity 16A, with 1 changeover (1 CO) 40 Amp 3 pole/230V Analog time switch with enclosure system in mounting arrangement and tripping mechanism alongwith suitable capacity of control MCBs as per INDOASIAN Cat Part No. TL040ABO or its equivalent approved make of L&T, C&S & Havells complete all as specified and directed. Note : Contractor shall submit 2 year warranty of distribution board from manufacturer alongwith purchase voucher.
Supply and fixing LED street light fittings 60 watt, 230 V AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp braket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection average life of street light 50000 hours, inluding clamps, nut, bots, bracket made of GI pipe light grade dia 32mm, length not less than 1.5m, bent to shape for LED fitting for fixing of LED light on electric LT pole including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre , testing to satisfaction of Engineer in charge complete all as specified and directed. Make :- Havells cat pat no ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent cat part in make specified in 'A' of particular specification Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Material and labour for preparation of old painted steel and iron surfaces and painting to steel tubular LT poles of any height , ant type (double swan / single swan) with two coats of synthetic enamel paint upto 1.5 m height above form ground level (in yellow, red and black strips of 30 cm wide each) and applying two coats of aluminium paint above 1.5 m height of poles including painting on cross arms, bracing, clamps etc and writing pole Nos. with thick black synthetic enamel paint complete all as specified and directed.
Material and labour for stringing stretching and stengthening of over head conductor (ACSR) Weasel (6/1x2.59 aluminium and 1x2.59 steel) on existing LT steel tubular pole or RS joist LT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc all as specified and directed. Note ;- Cutting/trimming of tree branches all around the LT over head conductor of any span upto 1.5m away including removing the same may included the rate quated.
Material and labour for stringing stretching and stengthening of over head conductor (ACSR) Squirel (6/1x2.11 aluminium and 1x2.11 steel) on existing LT steel tubular pole or RS joist LT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc all as specified and directed. Note ;- Cutting/trimming of tree branches all around the LT over head conductor of any span upto 1.5m away including removing the same may included the rate quated.
Supplying, installation, testing & commissioning of sub distribution board 4 way vertical TPN DB's suitable upto 100 Amp FP MCCB and single / three phase outgoing MCBs IP-54 protection double metal door factory fabricated from minimum 1.6 mm thick CRCA sheet wall mounting type in surface / recess powder coated 415V/250 Amps copper bus bar, earth and neutral bar with outgoing feeder complete in all respect DB's shall be original factory fabricated of approval make complete all as specified and directed. The rates shall be including all incommer and outgoing circuit breaker as under : - Incommer : - MCCB of capacity 100 Amps FP 415 Volts 50 Hz having rapturing cap 35 KA. Outgoing : MCB DP-10-40 Amp -06 Nos Bus bar - Copper busbar of capacity 200 Amps. Make : L&T cat pat No DBVTL00454 and its equivalent cat part in make : Havells, INDOASIAN, C&S.
Supplying, installation, testing & commissioning AMF panel/Atomatic transfer switch 160 Amp, suitable for 3 phase, 415 V AC as well as 1 phase sources, adjustable time delay (0.1 to 3 hours) ease of Generator control (On-OFF, cooling cycle self test) etc high mechanical and electrical life, double than requirement of IS/IEC standard of approval make complete all as specified and directed. Make : L&T cat pat No CK90162BSOO and its equivalent cat part in make Havells, INDOASIAN, C&S. Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supplying and installing commissioning of cubical LT Panel made out of angle iron 65mmx65mmx6mm on all side welded to 3mm thick CRC steel sheet with openable shutters on both sides (Front and rear) having locking arrangement totally enclosed weather proof, Indoor type, Powder coated suitable for 440 volts, 3 phase, 4 wire, 50 cycles, Aluminum bus bar of capacity 300 Amps, AC supply, electrically connected as per norms,CPRI approved and fitted with following :- (a) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA - 01 No (01 No for Incoming) (b) 3 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 01 Nos (Outgoing). (c) MCCB, 4 pole, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA -02 Nos. (Outgoing) (d) 3 ph multifunction metrer. (e) LED indicator lamp –01 No (set of three) Note : (i) The height of panel should be 0.60 mtr from ground level with PCC foundation. (ii) Each MCCB's having seperate enclosures.
Supply and Fixing LED flood light 70 watt , 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and average life of flood light not less than 50000 hours, including clamps, nut , bolts , bracket made of GI pipe light grade dia 32mm, length not less than 1.5m, bent to shape for LED light fitting for fixing of LED light on electric LT pole including 2 sqmm PVC twin core aluminium cable from conductor to treet light not less 2.0 metre , testing to satisfaction of Engineer in charge complete all as specified and directed.
Supply and Fixing pole mounting box / junction box made out of 1.66mm thick MS CRCA sheet / fibar sheet of size 230 x170 x 105 mm complete suitable for three phase connection with clamps of flat iron/GI off size 25 x 4 mm including suitable size nut, bolts, washer etc to fix on pole and provide with hinged door and locking system all painted with two coats of synthetic enamel paints over one coated red oxide paint and comprising of the following :- (i) AI busbar 150mm long size 20 x 50 mm fixed on four Nos porcelain insulator each busbar provided with four Nos of Nuts, bolts, washer for incoming and out going cable. (ii) MCB SP 230V 5 to 32A, 10 KA – 1 Nos.
Material and labour in repair for LT under ground cable Fault Detector for detect the fault in under ground cable including provision of jointing material which is required on site except cable joint kit, excavation in trenches upto depth of cable, returning filling and removing the extera material on site after completion of work complete all as specified and direcation by Engr-in-Charge.
Cutting/ trimming of tree branches of any width/ girth up to 3.0 mtr distance on both sides of LT over load lines including collection and depositing the retrieved timber at a place as directed by Engr-in-charge. Note :- (i). Tree branches will be left as it is the wood belong to cantt board/DO. They will be responsible for the wood. (ii) Contractor will be employ sufficient labour to complete the full one job with in above 15 days (iii). Contractor will be responsible for any type of accident while trimming the trees. (iv) Contractor superviser will take proper sit down for MES installation before starting the work and clear it before resuming power supply, however full assistant will be provided by MES staff.
kumar automobiles
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .