Supply installation testing and commissioning of different type air conditioner at SMS Hospital Jaipur
2026_SMSMC_604194_1
25_15.10.2026
Open Tender
Electrical Goods/Equipments
Item Wise
SMS Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Member Secretary, RMRS SMS Hospital
Exempted
17 Oct 2026
17 Oct 2026
29 Oct 2026
17 Oct 2026
28 Oct 2026
17 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply , Installation, Testing and Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year Original Equipment Manufacturer (OEM) warranty of both compressor and Printed Circuit Board (PCB). | |||||
| 1.1 | Cooling capacity 5000-5300 Watt, ISEER not less then 3.8 | 20 | Nos | - | - |
| 1.2 | Cooling capacity 6200-6350 Watt, ISEER not less then 3.8 | 10 | Nos | 65 | ₹650 |
| 2Supply , Installation, Testing and Comissioning of Window type Air conditioners as per BEE star rating complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 230 V +/- 10% with low & high voltage cutoff and 50 Hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation R-32/R-410 Green Refrigerant with Scroll / rotary compressor complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. | |||||
| 2.1 | Cooling capacity 4900 Watt, ISEER not less then 3.1 | 10 | Nos | 75 | ₹750 |
| 2.2 | Cooling capacity 7000 Watt, ISEER not less then 3.1 | 10 | Nos | 75 | ₹750 |
| 3Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. | |||||
| 3.1 | 4 KVA | 3 | Nos | 75 | ₹225 |
| 3.2 | 5 kVA | 3 | Nos | 75 | ₹225 |
| 4Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
NIT25DateDocument.pdf
Tender Documents • 9.04 MB
BOQ_1071652.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .