Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC Contract Awarded being lowest bidder. | |
| 2 | L2₹24.0 L+₹25,739.72 (1.09%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L2 | Rejected-AOC Rejected due to higher amount quoted. | |
| 3 | L3₹24.8 L+₹1.1 L (4.74%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L3 | Rejected-AOC Rejected due to higher amount quoted. | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Admitted due to firm is not having appropriate category i.e. b (ii). |
| Sl No | Description | Qty | Unit | BK CONSTRUCTION L3 | Electricals India L2 | ALBA AC AND REF SERVICES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in soft/loose soil and getting out complete all as specified and directed. | 19.24 | Cum | 250 ₹4,810 Lowest | 275 ₹5,291 | 250 ₹4,810 Lowest |
| 2.00 | Excavation in trenches not exceeding 1.5 m wide and exceeding from 1.5 m to 3 m in depth for including getting out Soft/Loose soil complete all as specified. | 8 | Cum | 280 ₹2,240 Lowest | 360 ₹2,880 | 360 ₹2,880 |
| 3.00 | Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed. | 14.24 | Cum | 105 ₹1,495.2 | 100 ₹1,424 | 72 ₹1,025.28 Lowest |
| 4.00 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. | 5 | Cum | 140 ₹700 | 126 ₹630 | 90 ₹450 Lowest |
| 5.00 | Mateial and Labour for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. | 4.66 | Cum | 1,450 ₹6,757 | 900 ₹4,194 Lowest | 900 ₹4,194 Lowest |
| 6.00 | Supplying and laying reinforced precast concrete cable cover, class HV, type 1 flat, size 300mm x 180mm x 40mm for HT cable and laid dry in trenches over underground cables all as specified and directed. | 250 | Each | 35 ₹8,750 Lowest | 54 ₹13,500 | 45 ₹11,250 |
| 7.00 | Supply and fix cable jointing kit for 11 KV grade cable for indoor termination Cold Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified and directed. | 6 | Each | 12,500 ₹75,000 | 9,540 ₹57,240 | 6,750 ₹40,500 Lowest |
| 8.00 | Supply and fix cable jointing kit for 11 KV grade cable for straight through Cold Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified and directed. | 2 | Each | 18,500 ₹37,000 | 19,300 ₹38,600 | 9,000 ₹18,000 Lowest |
| 9.00 | Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sqmm complete all as specified and directed. | 50 | RM | 1,090 ₹54,500 | 990 ₹49,500 Lowest | 1,000 ₹50,000 |
| 10.00 | Supply, installation, testing & commssioning incl transportation at site HT 12 kV,3Ph,21 kA-3 sec, 50Hz, 2 way non extendable outdoor type totally enclosed metal clad SF6, ring main unit having rupturing capacity upto 630A, with 02 way non extensible, with one direct cable module and one VCB configuration DV, active load-630 A, closed loop-630 A, off load cable charging 135 A, Earth fault-200 A, Earth fault cable charging-115 A, short circuit making capacity 52 A, equipped with external bushings which comply with DIN47636T1 & T2/EDF HN 525-61 for termination of cables, all bushings are situated in the same height from the floor and are protected by the cable cover, installing current transformers. The sheilding is laid back throgh the centre hole and earthed, voltage presence indication, system (VPIS) incl all accessories and mountings provided by the manufacturer with mounting base frame/platformcomplete in all respect, technical approval is required with all technical data and control drawings from accepting officer before incorporation of work. Make: ABB, Siemens, Schneider | 3 | Each | 4,30,000 ₹12,90,000 | 4,23,000 ₹12,69,000 Lowest | 4,28,000 ₹12,84,000 |
Tender Value
₹22.3 L
EMD Value
₹45,000
Closing Date
11 Jun 2025, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
SPECIAL REPAIR TO BER IMPROVEMENT OF HT SWITCHING SYSTEM BY REPLACEMENT AIR BREAK GOD SWITCH WITH AIR BREAK/SF6 BASED LOAD BREAK SWITCH UNIT AT MIL STN GANDHINAGAR
2025_MES_708125_1
87373/E8
Open Tender
Civil Works
Item Rate
120 days
ARMY AREA GANDHINAGAR
PLEASE REFER TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GE(A) GANDHINAGAR
₹45,000
Yes
13 Aug 2025
14 May 2025
19 Jun 2025
14 May 2025
11 Jun 2025
29 May 2025
14 May 2025 - 28 May 2025
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in soft/loose soil and getting out complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding from 1.5 m to 3 m in depth for including getting out Soft/Loose soil complete all as specified.
Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Mateial and Labour for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed.
Supplying and laying reinforced precast concrete cable cover, class HV, type 1 flat, size 300mm x 180mm x 40mm for HT cable and laid dry in trenches over underground cables all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination Cold Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for straight through Cold Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified and directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sqmm complete all as specified and directed.
Supply, installation, testing & commssioning incl transportation at site HT 12 kV,3Ph,21 kA-3 sec, 50Hz, 2 way non extendable outdoor type totally enclosed metal clad SF6, ring main unit having rupturing capacity upto 630A, with 02 way non extensible, with one direct cable module and one VCB configuration DV, active load-630 A, closed loop-630 A, off load cable charging 135 A, Earth fault-200 A, Earth fault cable charging-115 A, short circuit making capacity 52 A, equipped with external bushings which comply with DIN47636T1 & T2/EDF HN 525-61 for termination of cables, all bushings are situated in the same height from the floor and are protected by the cable cover, installing current transformers. The sheilding is laid back throgh the centre hole and earthed, voltage presence indication, system (VPIS) incl all accessories and mountings provided by the manufacturer with mounting base frame/platformcomplete in all respect, technical approval is required with all technical data and control drawings from accepting officer before incorporation of work. Make: ABB, Siemens, Schneider
Supply, installation, testing & commssioning incl transportation at site HT 12 kV,3Ph,21 kA-3 sec, 50Hz, 3 way non extendable outdoor type totally enclosed metal clad SF6, ring main unit having rupturing capacity upto 630A, with 02 way non extensible, with one direct cable module and two LBS( Load break switch) configuration DCC, active load-630 A, closed loop-630 A, off load cable charging 135 A, Earth fault-200 A, Earth fault cable charging-115 A, short circuit making capacity 52 A, equipped with external bushings which comply with DIN47636T1 & T2/EDF HN 525-61 for termination of cables, all bushings are situated in the same height from the floor and are protected by the cable cover, installing current transformers. The sheilding is laid back throgh the centre hole and earthed, voltage presence indication, system (VPIS) incl all accessories and mountings provided by the manufacturer with mounting base frame/platformcomplete in all respect, technical approval is required with all technical data and control drawings from accepting officer before incorporation of work. Make: ABB, Siemens, Schneider
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed .
S and F HT Junction Box, 11 KV , 1200(H) X 900(W) X 500(D) in mm in Size and overall size, CRCA MS Powder Coated, RAL 7035, 2 mm thick, IP 66, Front Door with DC Lock, Base (Ground) Mounted with 2 Nos of 100 x 100 Section Height minimum 900 mm with grouting plate of 10 mm thick of size 250 x 250, 11 KV , 3 Phase Without Neutral, Intra phase partition - FRP sheet of min 3 mm provided between phased Cladding on Door -FRP sheet of min 3 mm provided inside the door, Canopy- CRCA MS powder coated of size 1100 x 700 ( W x D in mm) Complete all as speciified and directed by Engr-in-charge. Note:- (i) HV Testing To be checked at 25 KV by calibrated HV tester (ii) Earthing 2 Nos External and 2 Nos of Internal – M12 Studs welded to body (iii) Blankers for Entries All entries provided by blanker plugs or plates OUTGOING ENTRIES SUITABLE FOR :3 x 95 sq.mm, MINIMUM BUSBAR SECTION OFALUMINIUM:50 x 10 and rating 400 A
Taking out old UNSV 2 pole structure11 KV by excavation and using special T &P hydra, JCB etc incl all GoD, lightening arrestor, channels etc complete all as specified and directed.
Taking out old UNSV 4 pole structure11 KV by excavation and using special T &P hydra, JCB etc incl all GoD, lightening arrestor, channels etc complete all as specified and directed.
Electricals India (BID ID -3312971)
BK CONSTRUCTION (BID ID -3307930)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .