General Manager RSRDC Ltd. Jaipur
Office of the Project Director RSRDC Ltd. Unit-Electrical, Jodhpur. High Court Campus, Near Shatabdi Circle, Jodhpur
Electrification work for HT Connection and LT Side Connection at all Blocks at Sport Complex, Physical College, Airforce Area, Jodhpur
2026_RSRDC_590483_1
RSRDC NIT 328/2026-27 (Sl-5)
Open Tender
Electrical Works
Percentage
90 days
Jodhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Through RTGS/NEFT/IMPS
₹43,000
19 Aug 2026
19 Aug 2026
27 Aug 2026
19 Aug 2026
25 Aug 2026
20 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR | 0 | Each | 0 | ₹0 |
| 2 | Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch | 1 | Each | 4,65,880 | ₹4,65,880 |
| 3 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | 0 | Each | 0 | ₹0 |
| 4 | Triple pole MCB (With B/C curve trippingCharacteristics) | 0 | Each | 0 | ₹0 |
| 5 | 50/63 A rating | 25 | Each | 1,384 | ₹34,600 |
| 6 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | 0 | Each | 0 | ₹0 |
| 7 | Metal door (single phase) IK-09 and IP-43 with Metal end box | 0 | Each | 0 | ₹0 |
| 8 | 12 Way (12+2) | 1 | Each | 2,590 | ₹2,590 |
| 9 | Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box | 0 | Each | 0 | ₹0 |
| 10 | 6Way(Incomer 8,Sub Incomer2+2+2) | 12 | Each | 7,618 | ₹91,416 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
AgrrementRTPPandetc.pdf
Tender Documents • 2.75 MB
BankDetail00.pdf
Tender Documents • 0.17 MB
BOQ_1048608.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].