Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹43.2 LAccepted-AOC KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | 1st | Accepted-AOC Being L1 | |
| 2 | 2nd₹43.6 L+₹42,931.30 (0.99%)Rejected-Finance BYPASS ROAD BESIDE YUG BAJAJ SHOWROOM GARIBICHOK PORBANDAR 360577 | PORBANDAR | GUJARAT | 360577 | 2nd | Rejected-Finance Being L2 | |
| 3 | 3rd₹45.5 L+₹2.3 L (5.26%)Rejected-Finance SHOP NO 06 FIRST FLOOR OPP CHAMUNDA HOTEL AT BOKHIRA DIST PORBANDAR GUJARAT 360 579 | PORBANDAR | GUJARAT | 360579 | 3rd | Rejected-Finance Being L3 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
4 Sept 2024, 6:00 pmClosed
LT COL UTKARSH SHARMA
OPP BIRLA FACTORY GE (I) CG PORBANDAR
PROVN OF UNIT RUN CANTEEN SHOPS AT INAZ VILLAGE ICGS VERAVAL UNDER GE (I) CG PORBANDAR
2024_MES_662221_1
8928/E8
Open Tender
Civil Works
Item Rate
180 days
VERAVAL
AS PER NIT
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹84,000
Yes
5 Nov 2024
26 Jun 2024
6 Sept 2024
26 Jun 2024
4 Sept 2024
11 Jul 2024
Amount
SCHEDULE 'A' B/R ITEMS
Surface dressing not exceeding 15 cm deep and getting out In soft/ loose Soil, complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and depth exc., 1.5 Metre and not exceeding, and getting out in soft/ loose soil, complete all as specified and directed by Engineer-in-Charge.
All as per item No 2 above, but depth exceeding 1.50 Metre but not exceeding 3.00 Metre, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for PCC 1:4:8, type D-2 (using 40mm graded aggregate) in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC M-30 (Design Mix), using 20mm graded stone aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to the sides of concrete footing, base of columns, plinth beams and similar work for vertical or to batter rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC M-30 (Design Mix), using 20mm graded stone aggregate, as in Columns, pillars, piers, posts and struts, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to the sides of columns for rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC M-30 (Design Mix), using 20mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.5 Metre span, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to sides and soffits of beams, bands and the like for rough finished surface of concrete, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC M-30 (Design Mix), using 20mm graded stone aggregate, as in chajja & canopy, complete all as specified and directed by Engineer-in-Charge.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide, complete all as specified and directed by Engineer-in-Charge.
Form work to chullah hoods, chajjas, trough and similar items including edges rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Material & Labour for RCC M-30 (Design Mix), using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC M-30 (Design Mix), using 20 mm graded stone aggregate, as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, balustrade, and the like, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to fins, louvers, fascia, parapet etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
All as per item No. 18 here-in-before, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering, complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance exceeding 500 Metre but not exceeding 1000 Metre and depositing where directed at level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Pre-cast cement concrete block masonary B-1 (1:3:6) 20mm graded aggregate with soild blocks, exceeding 10cm in width and setting in Cement Mortar (1:6), complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick, cement plaster, in cement mortar (1:4) in two layer one layer of 10mm thick and another 5mm thick layer mixed with integral water proofing compound as per manufactures instruction, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. Note:- Water proofing compound shall be measured and paid separately)
Supply only liquid water proofing compound as per manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 10mm thick on fair face of brick work or concrete surfaces in Cement Mortar 1:6 finished even and smooth wiithout using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 5mm thick cement plaster in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on ceiling in any height, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of surfaces and applying three coats of white wash on new plastered surfaces over a coat of putty on ceiling, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm all as per the manufacturers instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of newly plastered surfaces of wall and applying two coats of OBD over a coat of wall putty, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Glass reinforced Gypsum (GRG) Ceiling tiles of size 595mm x 595mmm x 8mm thick of approved design fixed with powder coated aluminium grid Sihouette of size main T (web 25 Flange 35 thickness 0.7mm), Cross- T (Web 25 Flange 35 thickness 0.7mm) and wall angle (Web+Flange 25 Flange 0.7mm), adjustable level clip with wire 4mm dia @ 1200mm c/c to hold the main T and soffit cleat (web 25 Flange 37 & 25 thickness 1.8mm) suitable for mounting tiles of size 595mm x 595mm including fabrication complete as per manufactures instructions, complete all as specified and directed by Engineer-in-Charge. Make :- Armstrong and equivalent.
Material & Labour for Cement concrete tiles 30cm x 30cm x 20mm thick machine pressed, set, jointed and pointed in neat cement slurry on roofs and cut and polished joint shall filled with grey cement and no pigments, including 15mm thick screed bed/ rendering in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for PCC 1:2:4 type B-1 (20mm graded aggregate ) as in fillets at junctions between roof and parapet walls, copings rounded or chamfered angles, bed plates, plinth courses, benching for manholes, filling in pressed steel frame and the like finished fair and even including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Cement concrete 1:3:6 type C-1 as in roof padding mass concrete using 20mm graded stone aggregate, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) including tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per Sqm including cleaning concrete surface by forced application, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing powder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing powder coated Anodised aluminium door shutters, aluminium section weighing not less than 0.55kg/m including 5.5 mm thick tinted glass necessary joining cleats, glazing clips, rubber neoprene packing, fancy handles 2 Nos, Mortice lock 4 lever in each door, snap beading, screws, double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass other parts made of heavy duty and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing powder coated aluminium anodised three track sliding window shutter and frame including jointing cleat for fixing frame/chowkhat of window as per JINDAL section code (frame 20831), shutter (20846) including glazing with 4mm thick tinted glass (02 shutters) & SS wire mesh (01 Shutter) necessary fittings, rubber packing, suitable handles, rollers for shutters and locking arrangement etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing anodised aluminium Powder coating ventilator shutters, fixed type without sash bars aluminium section weighing 0.55Kg/m including glazing with 4mm thick tinted glass necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminium snap beading screws, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Anodized aluminium grills of type Doco grill DG 104 or equivelent with Aluminium section of size 7.5mm x 6 mm with necessary channels and clips all as specified & directed by Engr-in-Charge.
Supply & Fixing solid PVC door frame (Single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure wood grain printed having smooth outer skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK screws, complete all as specified and directed by Engineer-in-Charge. NOTE:- Door frame shall be water proof, termite proof, elegant and should have excellent screw holding strength to fix hinges and hold doors properly for a long life.
Supply & Fixing factory made solid panel PVC door shutter 30mm thick (style) wood grain printed PVC sheet consisting of frame made out of M.S. tube for top & bottom rail. MS frame shall be covered with heat moulded PVC ”C” channel having a PVC steel strip of 20mm width stuck inside with solvent cement for style and for top rail lock rail & bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain coloured PVC sheet to be fitted in MS frame welded / sealed to style & rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frames at site as per specification & drawing, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 200mm long 10 mm dia Aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 150mm extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 100mm long stainless steel Butt hinges, best quality, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engineer-in-Charge.
Material & Labour For Hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 75mm thick PCC (1:3:6) type C-2 using 40 mm graded aggregate as in sub bases of flooring, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 75mm thick plain cement concrete B-2, 1:2:4 (using 40mm graded crushed stone aggregate) as in plinth protection finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-Charge. Note:- The plinth protection shall be laid in pannels and length of the each panel shall not be more than 2.00 mtr all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item.
Material & Labour for 15mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of 15 mm thick with cement mortar 1:6 etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Glazed coloured ceramic tiles in vertical surface 350x250x7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, with screed bed or rendering of 10 mm thick with cement mortar 1:4 etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Vitrified Ceramic tiles 10mm thick dark Shade Double charged (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. by using spacers to maintain a consistant spacing between tiles and the joints filled with epoxy grout of any approved colour having gout lines of uniform width set and jointed in neat cement slurry over and including 15 mm thick screed bed in Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Vitrified Ceramic tiles 10mm thick dark Shade Double charged (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick screed bed or rendering in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in Cement Mortar 1:6 for laying floor finishes etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing vitreous china padastal pattern, "EWC" coloured of size 570mm x 460mm x 380mm with 'P' trap and including Flushing cistern, CP jet spray and plastic sheet cover, connection to trap, and to flushing pipe anti-syphonage pipe, etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Stop/Angle valves, chromium plated, cast copper alloy, screwed down, high pressure, fancy type, screwed both ends for iron pipe or for unions and fixed for 20 mm bore pipes, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC connections 15mm size with brass chromium plated nuts of length 600mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 15mm Fancy Type long body C.P. Bib taps, cast copper alloy, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing vitreous china urinal, half stall type, of size 590mm x 390mm x 375mm, white but including waste pipe, coupling, CP jet separater, complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of CPVC pipes of size 25 mm outer dia SDR-11 & Plain CPVC SDR 11 fittings fixed complete to walls, ceilings or in floors, complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of CPVC pipes of size 20 mm outer dia SDR-11 & Plain CPVC SDR 11 fittings fixed complete to walls, ceilings or in floors, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing vitreous china wash hand basin, white Oval shape counter top of size 490mm x 360mm including brass chromium plated waste coupling 32mm dia, with fly nuts, pvc waste pipe and MS brackets incl cutting for and pining in ends of brackets, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 15 mm fancy type heavy duty, Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight 190gms), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing rotational moulded polythylene three layer white colour water storage tanks of capacity 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 25 mm bore, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 110mm PVC(SWR) pipes double socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 110mm PVC(SWR) pipes double socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 75mm PVC(SWR) pipes double socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 75mm PVC(SWR) pipes double socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC(SWR) vent cowl 75mm, complete all as specified and directed by Engineer-in-Charge.
Material & Labour PVC(SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC(SWR) bends any radius 110mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC(SWR) branch piece 110mm single (single Y) equal or unequal, with access door, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC(SWR) bends any radius 75mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 110mm dia PVC(SWR) bends with oval accesse door with rubber ring joints fixed as required, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC(SWR) reducers 110mm x 75mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC(SWR) floor trap with grating including jointing to waste pipe with dia of outlet 75mm, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 150mm bore RCC pipes class NP-2 laid and jointed complete with collars, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Cement concrete bed to drain pipes of 150mm dia (1:3:6) type C-2 using 40mm graded aggregate including packing under and haunching against sides of pipes after they are laid and tested, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for precast cement concrete (1:2:4) type B-1 (using 20mm graded aggregate) as in cover slabs for manholes etc. including necessary formwork and set in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Hardcore of gauge exceeding 63mm but not exceeding 100mm deposited spread and leveled in layers not exceeding 15cm thick watered and reamed to a true surface with broken stone or boulders, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for factory made rubber moulded, rubberized laboroda tiles, (Pre-Polished/ glossy finish) of PCC type A-1, of approved colour of size 400mm x 400mm x 30mm thick, including jointed with neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles, including 15mm thick screed bed in Cement Mortar 1:4, for laying of floor finishes, complete all as specified and directed by Engineer-in-Charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material exceeding 250 Metre but not exceeding 500 Metre and depositing where directed, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cement concrete type B-1, 1:2:4 (using 20mm graded stone agg) in surface channels and drain, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Reinforced concrete pipes 450mm dia, class NP 2 with one collar per length of pipe for Cement concrete bed to drain pipes of (1:3:6) type C2 using 40mm graded aggregate including packing under and haunching against sides of pipes after they are laid and tested, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge.
Internal Electrification
Material & Labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc. fixed concealed/ recessed in wall or ceiling etc. including 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire suitable for modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
One light /fan point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board .
Material & Labour for Point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, suitable for modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing modular switch 1 way, 6 Amps, 1 modular (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make :- Legrand / Anchor (Roma)/ L&T
Supply & fixing modular switch 1 way, 16 Amps, 1 modular (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make :- Legrand / Anchor (Roma)/ L&T
Supply & fixing modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked) . complete all as specified and as directed by Engr-in-Charge. Make :- Legrand / Anchor (Roma)/ L&T
Supply & fixing modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make :- Legrand / Anchor (Roma)/ L&T
Supply & fixing modular fan regulator, 120 watt, 2 moduler (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make :- Legrand / Anchor (Roma)/ L&T
Supply & fixing ceiling rose, surface bakelite, 65mm x 17mm three terminals (ISI Marked), complete all as specified and directed by Engineer-in-Charge. Make :- Legrand / Anchor (Roma)/ L&T
Supply & Fixing for motor strater 2 module, Modular MCB 16 Amps 1 module including suitable for PVC Box 3 Module with Cover plate, complete all as specified and directed by Engineer-in-Charge. Make :- Legrand, Cat no. 6730 30/ 6730 64/ or equivalent.
Supply & Fixing for Modular Socket 6A/16A - 2/3 pin 3 Module type, 240 volts, including suitable for PVC Box 3 Module with Cover plate, complete all as specified and directed by Engineer-in-Charge. Make :- Legrand, Cat no. 673095 or equivalent.
Supply & Fixing of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Wipro - CAT PT No- LL20-281-XXX-65AL1** or equivalent to Bajaj / Havells
Supply & Fixing of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Wipro - CAT PT No- LL20-111-XXX-65NE3* or equivalent to Bajaj / Havells
Supply & Fixing 1 x 18 Watts LED False ceiling downlight with pressure die-cast aluminium housing made of metallic CRCA powder coated housing with high trasluent HET diffuser and integrated electronic 6500 K, including electrical connection with 3 core flexible conductor cable of appropriate size, complete all as specified and directed by Engineer-in-Charge. Make:- Wipro Cat No LD90-231-XXX-65-XX*** Equivalent from Havells /Philips Note- cost of replacing in cut out of false ceiling deemed to be included in unit rate
Supply & Fixing BEE five star rated BLDC energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan, complete all as specified and directed by Engineer-in-charge. Make: Crompton /Orient Cat No Tome/ Havells Cat- or equivalent make mentioned in make of list.
Supply and fixing Exhaust fan 300mm sweep 240V AC metal body fixed as per maufacturers instruction, connecting with and including 2 core x 0.5 Sqmm copper coduct PVC insulated and PVC sheathed three core cable complete or equivalent, complete all as specified and directed by Engineer-in-Charge. Make:- Orient, CG, Havells, Usha
Supply and fixing AC Single phase Two wire tamper proof static meter of Class 1.0, 240 V 50Hz basis current 10A. Max continuous current 600% of basis conforming to IS-13779 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in Cyantech or equivalent Mesh network with default and no demand display, billing data generation facility anti tamper fearures microprocessor and LED/LCD based circuitry, complete all as specified and directed by Engineer-in-Charge. Make:- L&T, Havells, Bentec, HPL or equivalent
Supply & Fixing distribution Board cum Meter box wall mounting type of size 980mm X 950mm X 335mm (minimum) fabricated from polycarbonate sheet, IP 54 cimpartmentalised design, Cable gland of suitiable size prewired and comprising of following :- (a) MCCB cap 63 Amps, 4 Pole, 16 KA - 01 No. (b) MCB SPN 40 Amp, 10 KA - 05 Nos & MCB SP 6 Amps -04 Nos (c) Terminal for distribution (d) 05 Nos of cubicals for housing single phase meter Make:- HENSEL / HAGER / HPL / L&T
Material & Labour for sub main wiring with two single core 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 2.5 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, complete all as specified and directed by Engineer-in-Charge. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
Supply & Fixing of MCB DB 8 way SPN, double door, vertical type, IP- 53 with 200 Amps rated bus bar, Concealed and connecting up, complete all as specified and directed by Engineer-in-Charge. Make : Legrand / ABB/ Hager
Supply and fixing of MCB SPN, 240 volt, 32 Amps complete all as specified and directed by Engineer-in-Charge. Make : Legrand / ABB/ Hager
Supply and fixing of MCB SP, 240 volt, 6 to 32 Amps, complete all as specified and directed by Engineer-in-Charge. Make : Legrand / ABB/ Hager
Supply, laying and jointing GI tubes 25mm bore medium grade in any lengths with screwed and socket joints, together with all galvanised steel fitting such as sockets, elbows, bends, tees, reducers, unions, cap plugs, nipple, short pieces etc. fixed complete by means of and including clips, wall hook etc. or laid in trenches, complete all as specified and directed by Engineer-in-Charge. Make - Tata / Jindal / Surya Prakash
Supply & Fixing Gun metal gate valve of size 25mm dia with iron wheel head screwed both ends for iron pipes, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cutting of existing DI/CI Pipe in position for inserting CI Tee complete with 50mm dia union, nipple, etc. all as directed for taking 25mm GI branch line, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Construction of new valve chamber of size 600mm X 600mm X 600mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in Cement Mortar 1:6 with 10mm thick plaster internally and 15mm thick externally in Cement Mortar 1:4, 6mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40mm X 40mm X 6mm MS angles complete with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works & two coats of white wash on all plastered surfaces of valve chambers, complete all as specified and directed by Engineer-in-Charge.
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 35 Sqmm 4 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc. all connections complete as required at site, complete all as specified and directed by Engineer-in-Charge. Make : Polycab / Havells/ RR Kabel
Supply & Fixing of GI steel tubing light grade 32mm dia for laying in ground and road crossing along the pole in coping etc. for cable protection including necessary fittings, clamps for supports, etc., including making good the disturbed surfaces of walls/floor etc., complete all as specified and directed by Engineer-in-Charge. Make - Tata / Jindal / Surya Prakash
Supply and laying 50 /38 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor, complete all as specified and directed by Engineer-in-Charge. Make : Rex / Poly/ Gemini
Material & Labour for cutting existing road/hard standing not exceeding 45cm x 45cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for bore Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge.
M/S Unicon Engineering co (BID ID -3063889)
VIVEK JITENDRABHAI KATAR (BID ID -3079988)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .