Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAdmitted-Finance 589 BC BAZAR AMBALA CANTT AMBALA | L1 | Admitted-Finance | |
| 2 | L2₹11.1 L+₹3.7 L (50.2%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹11.7 L+₹4.3 L (57.7%)Admitted-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VARDHMAN SALES CORPORATION L1 | Shree Karni Construction L3 | vinayandsons L2 |
|---|---|---|---|---|---|---|
| 1.00Note - Rate quoted above all items inclusive provision as under :Making arrangement for establishment of centralized complaint centre in the existing building as under :- (a) Contractor shall be given user id and password for accessing the online complaint portal and contractor shall at his own expense by himself or his representative feed the data in r/o complaints so generated. (b) Manually registered complaints shall be obtained everyday from MES complaint cell and rectification or otherwise shall be intimated to JE in charge of the cell for updation of manual registers. (c ) Provision and maintenance of all tools, plants, equipment and safely gear required for tradesmen under this contract (d) Provision of communication and conveyance (as required) facilities to supervisor and tradesmen. (e) Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (f) Updating status of lodged complaints on a daily basis. (g) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone (j) On lodging the complaint, the Complaint No will be assigned for reference . Also system should indicate an approximate time for repairs. Accordingly a corresponding complaint slip shall be generated by the system with all relevant info. Complaint slip should be printed in triplicate and to be handed over immediately to Supervisor who shall detail appropriate tradesmen for repair with required materials/store. One copy of complaint shall be retained in complaint centre and two copies with tradesmen. | ||||||
| 2.00(k) On both copies of complaint slip, status of the complaint attended shall be endorsed by the complaint/user. One copy to be retained by the complainant and second copy to be with tradesmen for handing over in the complaint centre. Reasons for non attending of complaint etc shall be recorded alongwith estimate of expected time to attend and rectifying the complaint. (l) At the end of each day, summary of complaints shall be prepared and generated indicating No of complaints lodged, attended in time, Reasons for not attending , probable time required for attending the pending complaints etc (m) JE in charge of MES will review the complaints recorded in the system daily and will carry out personal inspection of complaints attended and its status and will take remedial measures in this regard. (n) AGE will visit the complaint cell at least twice a week to check the efficacy of the system and record their remarks accordingly. Space for complaint cell/Office & Store will be Provided by the Department. (o) The tradesmen engaged in the contracts shall be ITI qualified from a govt recognised institute and the contractor is required to get the same approved from Accepting Officer (before applying for their security passes) immediately on acceptance of contract. (p) All tradesmen shall be dressed in a common uniform and quoted rates should be inclusive of that. Tradesmen not wearing uniform shall not be allowed in the gate and any loss on that account shall be attributable solely to the contractor. (Q) If contractor fails in attend/rectify complaint or depute trademens to attend complaint for any day, penal recovery of @ Rate Rs 500 per Complaint Slip will be deducted/recovered at the time of payment/RAR. | ||||||
| 3.00 | Supply & fixing in repairs/replacement switch piano, flush type single pole one way 5Amp, 240 volts ISI marked complete all as specified and directed . | 260 | Each | 81 ₹21,060 | 65 ₹16,900 | 30 ₹7,800 Lowest |
| 4.00 | Supply & fixing in repairs/replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed . | 60 | Each | 101 ₹6,060 | 65 ₹3,900 | 60 ₹3,600 Lowest |
| 5.00 | Supply & fixing in repairs/replacement Switch socket outlet combined 2 in 1, 6 amp flush type , 240 volts ISI marked complete all as specified and directed. | 60 | Each | 50 ₹3,000 Lowest | 65 ₹3,900 | 150 ₹9,000 |
| 6.00 | Supply & fixing in repairs Switch socket outlet combined 2 in 1 , 3 pin 6 amp and 16 amp flush type , 240 volts ISI marked complete all as specified and directed. | 50 | Each | 39 ₹1,950 Lowest | 50 ₹2,500 | 260 ₹13,000 |
| 7.00 | Supply & fixing in repairs Socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed. | 30 | Each | 33 ₹990 Lowest | 35 ₹1,050 | 160 ₹4,800 |
| 8.00 | Supply & fixing in repairs switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed . | 40 | Each | 58 ₹2,320 | 45 ₹1,800 Lowest | 140 ₹5,600 |
| 9.00 | Supply & fixing in repairs switch piano, flush type single pole 2 way 5 Amps, 240 volts ISI marked complete all as specified and directed . | 45 | Each | 81 ₹3,645 | 42 ₹1,890 Lowest | 48 ₹2,160 |
| 10.00 | S&F in repairs Modular switch 1 way 6A,1 module , 240 volts ISI marked complete all as specified and directed | 60 | Each | 94 ₹5,640 | 50 ₹3,000 Lowest | 50 ₹3,000 Lowest |
Tender Value
₹9.8 L
EMD Value
₹19,500
Closing Date
12 Jun 2026, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LABORATORY JODHPUR
REPAIR /REPLACEMENT OF INTERNAL FITTING, FIXTURE AND DAY TO DAY E/M WORKS IN DEFENCE LABORATORY JODHPUR
2026_MES_766681_1
8740/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹19,500
Yes
22 Jun 2026
20 May 2026
15 Jun 2026
20 May 2026
12 Jun 2026
29 May 2026
21 May 2026 - 28 May 2026
Note - Rate quoted above all items inclusive provision as under :Making arrangement for establishment of centralized complaint centre in the existing building as under :- (a) Contractor shall be given user id and password for accessing the online complaint portal and contractor shall at his own expense by himself or his representative feed the data in r/o complaints so generated. (b) Manually registered complaints shall be obtained everyday from MES complaint cell and rectification or otherwise shall be intimated to JE in charge of the cell for updation of manual registers. (c ) Provision and maintenance of all tools, plants, equipment and safely gear required for tradesmen under this contract (d) Provision of communication and conveyance (as required) facilities to supervisor and tradesmen. (e) Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (f) Updating status of lodged complaints on a daily basis. (g) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone (j) On lodging the complaint, the Complaint No will be assigned for reference . Also system should indicate an approximate time for repairs. Accordingly a corresponding complaint slip shall be generated by the system with all relevant info. Complaint slip should be printed in triplicate and to be handed over immediately to Supervisor who shall detail appropriate tradesmen for repair with required materials/store. One copy of complaint shall be retained in complaint centre and two copies with tradesmen.
(k) On both copies of complaint slip, status of the complaint attended shall be endorsed by the complaint/user. One copy to be retained by the complainant and second copy to be with tradesmen for handing over in the complaint centre. Reasons for non attending of complaint etc shall be recorded alongwith estimate of expected time to attend and rectifying the complaint. (l) At the end of each day, summary of complaints shall be prepared and generated indicating No of complaints lodged, attended in time, Reasons for not attending , probable time required for attending the pending complaints etc (m) JE in charge of MES will review the complaints recorded in the system daily and will carry out personal inspection of complaints attended and its status and will take remedial measures in this regard. (n) AGE will visit the complaint cell at least twice a week to check the efficacy of the system and record their remarks accordingly. Space for complaint cell/Office & Store will be Provided by the Department. (o) The tradesmen engaged in the contracts shall be ITI qualified from a govt recognised institute and the contractor is required to get the same approved from Accepting Officer (before applying for their security passes) immediately on acceptance of contract. (p) All tradesmen shall be dressed in a common uniform and quoted rates should be inclusive of that. Tradesmen not wearing uniform shall not be allowed in the gate and any loss on that account shall be attributable solely to the contractor. (Q) If contractor fails in attend/rectify complaint or depute trademens to attend complaint for any day, penal recovery of @ Rate Rs 500 per Complaint Slip will be deducted/recovered at the time of payment/RAR.
Supply & fixing in repairs/replacement switch piano, flush type single pole one way 5Amp, 240 volts ISI marked complete all as specified and directed .
Supply & fixing in repairs/replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed .
Supply & fixing in repairs/replacement Switch socket outlet combined 2 in 1, 6 amp flush type , 240 volts ISI marked complete all as specified and directed.
Supply & fixing in repairs Switch socket outlet combined 2 in 1 , 3 pin 6 amp and 16 amp flush type , 240 volts ISI marked complete all as specified and directed.
Supply & fixing in repairs Socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
Supply & fixing in repairs switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed .
Supply & fixing in repairs switch piano, flush type single pole 2 way 5 Amps, 240 volts ISI marked complete all as specified and directed .
S&F in repairs Modular switch 1 way 6A,1 module , 240 volts ISI marked complete all as specified and directed
S&F in repairs Modular switch 1 way 16A, 1 module , 240 volts ISI marked complete all as specified and directed
S&F in repairs Modular Socket, 6A - 2/3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed
S&F in repairs Modular Socket 6A/16A - 2/3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed
S&F in repairs Modular Fan step regulator, 120W 1 module , 240 volts ISI marked complete all as specified and directed
S&F in repairs modular white cover plate with frame 3 module complete all as specified , 240 volts ISI marked complete all as specified and directed
S&F in repairs modular white cover plate with frame 4 module complete all as specified , 240 volts ISI marked complete all as specified and directed
S&F in repairs modular white cover plate with frame 6 module complete all as specified , 240 volts ISI marked complete all as specified and directed
S&F in repairs modular white cover plate with frame 8 module complete all as specified , 240 volts ISI marked complete all as specified and directed
S&F in repairs modular white cover plate with frame 12 module complete all as specified , 240 volts ISI marked complete all as specified and directed
Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 8 way with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified & as directed by Engr-in-charge. Make : Havells /LEGRAND /L&T/ C&S/ SCHIENDER/ABB/ANCHOR. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface.
Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 12 way with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified & as directed by Engr-in-charge. Make : Havells /LEGRAND /L&T/ C&S/ SCHIENDER/ABB/ANCHOR. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface.
S&F in repairs 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
S&F in repairs 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing in repairs SPN 32 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing in repairs SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply & fix in repairs calling bell ding dong/buzzer ,AC 230Volts single pole complete all as specified and directed.
Supply & fix in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
S & F in repairs for bell push , flush type single pole , 5Amp, 240 volts all as specified .
S&F in repairs Ceiling Rose 3 terminal surface type Complete all as directed.
M& L in repairs for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
M& L in replacement Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K Complete all as directed.
S & F in replacement Surface and wall mounted high efficiency 1x20 watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver CRI >80, Beam Angle 120° complete with all accessories internally pre wired and including connection up with twin core flexible copper conductior cable all as specified and directed.
S&F in repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fix in replacement of LED Decorative wall light fixture made up of Polycarbonate, suitable for LED Bulb 09/12W(B-22 base) complete all sepcified and directed. Make : Havells/BAJAJ/WIPRO/CROMPTON /HPL/PHILLIPS
S&F in replacement of LED 18 watt Environmental friendly, ultra modern, energy saving, surface (round / square type) or ceiling, recessed mounted, decorative LED luminaire comprising of high brightness LEDs, IP54 protection complete all sepcified and directed.
S&F in repairs bulk head luminaries IP65 with opal diffuser 10 watt, 230 Volts LED type complete with 10 watt LED Bulb all as directed Engr-in-Charge.
Supply and fixing in repairs plug top 15 Amps complete all as specified and directed.
Labour for repair/servicing of ceiling fan of any capacity complete with strip opening of ceilling fan for repair/cleaning/varnishing and removing of old lubricating substances from bearing/ bush by using Kerosine oil, carrying out fresh lubrication , greasing and to make the ceiling Fan noise free and smooth functioning, including replacement of worn out/unserviceable minor spare parts split pin,fan body bolts,spring washer,fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan and testing to the entire satisfication of engineer in charge and refifixing in its orginal position all as specified and directed. (Replacement of Spares flexible wire etc/rewinding of ceiling fan/shall be measured and paid seperately under respective item for material and labour cost .)
All as per Srl item No. 32 above but for exhaust Fan of any type and any sweep
Rewinding of ceiling fan, of any make/type and size (1200 /1400 mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection & testing complete.
All as per Srl item No. 34 above but for exhaust fan of any make/type but of size 250/300/380 mm sweep.
Labour for remetalling of worn out shaft of fan, cutting,bracing,machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in repair of bushing system in ceiling fan and assembling the same and testing to the engineer satifaction of engineer in charge to ensure smooth and noise free operation (bearing shall be measured and paid seperately )
Supply and fixing in replacement ball bearing of any size and type, suitable for ceiling Fan .
All asper item No. 37 above but for exhaust fan of any type/make and size
Supply & fixing in repair of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and Rated capacity 2.5 MFD for ceilling fan & exhaust fan.
All as per item No. 39 above but of rated capacity 4.0 MFD for Exhaust Fan.
Supply and connection of PVC insulated, unsheathed multi stranded,three core twisted copper flexible cable of size 1.5 Sqmm as required. .
Supply and fixing in replacement bush of suitable size for ceiling fan/exhaust fan of any type/size as per existing type.
Supply and fixing in replacement of PVC clamps with fixing screws for holding capacitor of any type and size.
Supply and fixing in replacement of GI/ MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole
S&F in repair MS clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts,split pin and washers suitable for housing ceiling fan.
S&F in repair of ceilling fan down rod 12 mm dia and 30/45 cm long complete with MS Clamp Rubber reel,split pin nut bolts etc.
S&F in replacement Printed circuit board (PCBs) suitable for BLDC ceiling fans of 1200 mm. Make - As per sample .
Supply and fixing in repair of louver shutter made out of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made o MS flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall at ground/First/Second floor etc complete with using fastener bolt,driling for exhust fan up to 400 mm sweep incl taking down old one.
Cleaning of ceiling fan assembly of any type/size and carrying out two coat of spray painting with first quality synthetic enamelled paint of approved colour all as directed and specified.
S&F in repair PVC Canopy set of two pieces for ceiling fans of any size
S&F in repair Ceiling Fan blade set of three pieces suitable for 1200/1400 mm sweep of White/Brown/Ivory colors all as specified and directed. Make - As per Sample
Taking down and strip opening to geyser of any make and capacity 25 / 35 / 50 ltrs including disconnection of all water pipe connection and taking out water inlet / outlet assembly, removing glass wool, the inner tank, descaling the assembly and tank, detecting the leakage, welding / brazing the defective parts, repacking the glass wool and refixing the same after making it functional including replacement of worn out nuts, bolts, washers etc complete all as specified and as directed.
Material and labour in repair of water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25 / 35 ltrs capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc complete all as specified and as directed.
Material and labour in repair thermostat, switch for electric water heater storage type of capacity 25 / 50 ltr, 230 Volts of existing make of geyser complete all as specified and as directed.
Material and labour in repair heating element with triangular base / round base, single phase, 230 Volt, capacity 2 KW of existing make complete all as specified and as directed.
Material and labour in repair pressure release valve conforming to relevant IS 15mm bore suitable for fixing with GI pipe / tubing 15mm bore complete all as specified and as directed.
Material and labour in repair of heavy duty PVC connection (For Hot water) nylon threaded 450mm large (18") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
Material and labour in repair of heavy duty PVC connection (For Cold water) nylon threaded 450mm large (18") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
Material and labour in repair of indicator lamps round / rectangular type 230 Volt AC suitable for geyser of any capacity including providing electric connections complete all as specified and as directed.
Material and labour in repair water storage inner tank of stainless steel heavy duty confirming to ISI suitable for 25 ltrs capacity geyser, with provision for fixing 15mm dia galvanized air release valve complete all as specified and as directed.
Material and labour in repair Non return Valve 15mm dia,made up of brass complete all as specified and as directed.
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches,sockets, ceiling roses,bell push,bell electric,lamp holder,bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron,round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Material and labour for point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC FRLSH insulated unsheathed 1100 Volt grade cable in and incl PVC FRLS casing capping PIPE (ISI Marked) with all accessories including new pressed steel terminal boxes (sunk in wall ) with 3.00 mm thick plastic laminated sheet top cover or PVC FRLS board including PVC FRLS top cover with 1.50 sq mm insulated unsheathed PVC FRLSH multistranded covered copper conductor for common earth and connecting to earth dolly and making good disturbed surface of wall incl matching the colour of wall/ceiling with extisting wall/ceiling colour all as specified and directed for
(i) One light/ceiling fan/ex fan/ bell point controlled by one switch one way
(ii) One socket out let 5 Amps 5 Pin on same board with other switch
(iii) One socket out let 5 Amps 5 pin on independent board
All as per item No 53 here in before but with single core multistranded cable of size 2.5 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 2.5 Sq mm all as specified and directed
Supply & fixing switch piano, flush type single pole one way 5Amp, 240 volts ISI marked complete all as specified and directed .
S & F in replacement only Socket out let 2 in 1, 3 pin, 5 Amps flush type 230 volts
Supply & fixing Switch socket outlet combined 2 in 1 , 3 pin 5 amp and 15 amp flush type , 240 volts ISI marked complete all as specified and directed.
Supply & fix calling bell ding dong/buzzer ,AC 230Volts single pole complete all as specified and directed.
Supply & fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
S & F for bell push , Modular flush type single pole , 5Amp, 240 volts all as specified .
S&F Ceiling Rose 3 terminal surface type Complete all as directed.
S&F for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
S&F Self ballast LED retrofit Lamp with PVC body and PC Diffuser 12 watt 230 Volt 6500K Complete all as directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid/ 1.8mm wall thickness ISI marked including Modular Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :- Note: suitable Modular white cover sheets with frame as specified to be provided in replacement to MS/Galvanised sunken boxes and measured & paid separately as per relevant item. Note : (a) wiring shall be done by using proper colour coding including making disturb surface good (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
All as per item No 83 here in above but 5 Amp socket outlet on same board
All as per item No 83 here in above but socket outlet 5 Amps independent board complete all as directed by Engr-in-Charge.
All as per Item No 83 here in above but for one 6 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size.
S&F Modular switch 1 way 6A,1 module , 240 volts ISI marked complete all as specified and directed
S&F Modular switch 1 way 16A, 1 module , 240 volts ISI marked complete all as specified and directed
S&F Modular Socket, 6A - 2/3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed
S&F Modular Fan step regulator, 120W 1 module , 240 volts ISI marked complete all as specified and directed
S&F Modular bell push 6A 1 module.
S&F bulk head luminaries IP65 with opal diffuser 10 watt, 230 Volts LED type complete with 10 watt LED Bulb all as directed Engr-in-Charge.
S&F in replacement of LED 36/40 watt (2X2 feet) Environmental friendly, ultra modern, energy saving, surface or ceiling, recessed mounted decorative bulk head LED luminaire comprising of high brightness LEDs, IP54 protection complete all sepcified and directed.
S & F in replacement Surface and wall mounted high efficiency 1x20 watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver CRI >80, Beam Angle 120° complete with all accessories internally pre wired and including connection up with twin core flexible copper conductior cable all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply & Fixing in replacement industrial type sheet metal enclosures with a two pin and earth plug and socket, 250 volts with including 20 Amp SP MCB complete all as specified and directed.
Taking down old submain wiring and S&F in replacement of sub main wiring using two single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size 4 Sq.mm of 1100 Volts voltage rating drawn through and including PVC casing caping/PVC Conduit as per site reqmt of size not less than 25mm with standard accessories, along-with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sq.mm as earth continunity conductor complete all as specified and directed. Note : Two run of single core FRLSH PVC cable with one run of earth conductor and conduit shall be measured as one unit.
ditto as per item no 47 but for 2x6.0 sq. mm + 1x6.0 sq. mm earth wire
ditto as per item no 47 but for 2x10.0 sq. mm + 1x10.0 sq. mm earth wire
ditto as per item no 47 but for 2x1.5 sq. mm + 1x1.5 sq. mm earth wire
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
PS.pdf
Tender Documents • 0.50 MB
BOQ_858636.xls
BOQ • 4.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .