Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance ALI NAGAR KABRI PATTI BHULI ROAD DHANBAD JHARKHAND | DHANBAD | DHANBAD | JHARKHAND | 826001 | +18.45% | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.6 Cr+₹1.6 L (0.97%)Admitted-Finance | +19.60% | ₹1.6 Cr+₹1.6 L (0.97%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical NABAGRAM DURGAPUR DISTRICT BURDWAN WEST BENGAL 713363 | DURGAPUR | BURDWAN | WEST BENGAL | 713363 | - | - | - | Rejected-Technical Reject |
| 4 | Rejected-Technical KUSAI COLONY DORANDA RANCHI 834002 | RANCHI | RANCHI | JHARKHAND | 834002 | - | - | - | Rejected-Technical Reject |
Tender Value
₹1.6 Cr
EMD Value
₹2.0 L
Closing Date
15 Aug 2026, 6:00 pmClosed
AREA MANAGER (ENM) KATRAS AREA
OFFICE OF THE GENERAL MANAGER BCCL KATRAS AREA IV ENM DEPT. Post-SIJUA PIN-828121 JHARKHAND
DISMANTLING OF FOUR EXISTING HT FEEDER AND RE ERECTION OF 4 HT FEEDERS NAMELY FEEDER - 2 (3.3KV), FEEDER - 5 (6.6KV), FEEDER - 7 (6.6 KV) AND FEEDER 8 (3.3KV) FROM KANTAPAHARI SUBSTATION TO KANATAPAHARI PATCH PROPOSED PUMPING STATION
2026_BCCL_362911_1
BCCL/KA-IV/AM (ENM)/e-TENDER/2026-27/38 DATE 1.8.2026
Open Tender
Electrical and Maintenance Works
Percentage
75 days
KATRAS AREA IV
Please refer Tender documents.
9 documents required · 9 mandatory
₹2.0 L
4 Sept 2026
1 Aug 2026
17 Aug 2026
1 Aug 2026
15 Aug 2026
1 Aug 2026
1 Aug 2026 - 8 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ITEM DESCRIPTION / HEADLING | |||||
| 1.01 | (A) FEEDER 2 Supply of MS Tubular pole -12 mtr | 88 | Nos | 12,300 | ₹10,82,400 |
| 1.02 | Erection of Metallic Pole upto 12 meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal) Foundation including excavation and refillingetc as required | 88 | Nos | 3,185.86 | ₹2,80,355.68 |
| 1.03 | Supply and erection of 11KV pin insulator complete with large steel head GI Pin, nut washer etc as required | 132 | Nos | 337.62 | ₹44,565.84 |
| 1.04 | Supply and erection of 11KV disc insulator for 11kv overhead line with galvanised insulator fitting, ball and socket type and complete with galvanised strain clamps, bolt, nut, washer etcas required | 132 | Nos | 1,071.41 | ₹1,41,426.12 |
| 1.05 | Supply and erection of GI Wire 8 SWG | 400 | KG | 73.74 | ₹29,496 |
| 1.06 | Erection of GI wire 8 No SWG including Binding | 400 | KG | 11.89 | ₹4,756 |
| 1.07 | Supply of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. | 1 | Nos | 42,627.96 | ₹42,627.96 |
| 1.08 | Erection of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. | 1 | Nos | 3,500 | ₹3,500 |
| 1.09 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) V Shape cross arm for two 11KV overhead line conductor complete with 50mm x 6mm M.S. Flat iron clamps, bolts, nuts, and washers etc (as per drawing) and painting with primer and finish paint as required. | 44 | Set | 958.87 | ₹42,190.28 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.61 MB
Tendernotice_2.pdf
PDF • 1.76 MB
Tendernotice_3.pdf
PDF • 0.72 MB
BOQ_375855.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .